| Brand | AMAE |
|---|---|
| Model | MI-101 |
| Origin | Guangdong, China |
| Instrument Type | Tamping Rod for Flow Moisture Point (FMP) and Transportable Moisture Limit (TML) Testing |
| Compliance | IMSBC Code Annex 1, Section 4.2 (Proctor–Fagerberg Method) |
| Application | Solid Bulk Cargo Stability Assessment |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 108 |
| Instrument Type | Digital Food Thermometer |
| IP Rating | IP67 (with Softcase) |
| Thermocouple Compatibility | Type K and Type T |
| Measurement Range | –50 to +300 °C (both types) |
| Accuracy | ±0.5 °C (–30 to +70 °C) |
| Resolution | 0.1 °C |
| Response Time (t₉₀) | ≤10 s in moving liquid |
| Display | Single-line LCD, large-digit |
| Operating Temperature | –20 to +60 °C |
| Storage Temperature | –30 to +70 °C |
| Weight | 154 g (instrument + battery), 210 g (incl. Softcase) |
| Dimensions | 140 × 60 × 24 mm |
| Housing Material | ABS / ABS-PC with 10% glass fiber |
| Power Supply | 3 × AAA rechargeable batteries |
| Battery Life | up to 2500 h at 23 °C |
| Compliance | EN 13485, HACCP principles, EU EMC Directive 2004/108/EC |
| Brand | testo |
|---|---|
| Model | 0572 6560 |
| Sensor Type | Integrated NTC temperature sensor + capacitive humidity sensor |
| Measurement Range | -20 to +70 °C, 0–100 %RH |
| Accuracy | ±0.5 °C (-20 to +70 °C) ±1 digit |
| Resolution | 0.1 °C, 0.1 %RH |
| Data Storage Capacity | 16,000 readings |
| Logging Interval | 1 min to 24 h (user-selectable) |
| Operating Temperature | -20 to +70 °C |
| Storage Temperature | -40 to +70 °C |
| Protection Class | IP20 |
| Power Supply | Included battery (CR2450) |
| Interface | USB |
| Software Compatibility | Windows XP, Vista, Windows 7 |
| Compliance | CE, RoHS |
| Data Retention | Non-volatile memory — data preserved even after battery depletion |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 6082 |
| Instrument Type | Thermo-Hygrometer |
| Category | Physical Property Testing Instruments – Other |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 6352 |
| Instrument Type | Thermo-Hygrometer |
| Key Measurement Capabilities | Relative Humidity, Air Temperature, Surface Temperature, Center Temperature, Absolute Pressure, Pressure Dew Point, Calculated Dew Point, Dew Point Difference, Moisture Content (via probe), U-value (via optional calculation module) |
| Display | Backlit LCD with Max/Min/Avg Logging |
| Data Storage | Up to 10,000 readings |
| Interface | USB (PC connectivity), Optional IR Printer Support |
| Enclosure | ABS/TPE/Metal |
| Weight | 428 g |
| Dimensions | 220 × 74 × 46 mm |
| Operating Temperature | −20 °C to +50 °C |
| Battery | Alkaline, ~200 h lifetime |
| Storage Temperature | −30 °C to +70 °C |
| Brand | TQC Sheen |
|---|---|
| Country of Origin | Netherlands |
| Model | CurveX 4 |
| Dimensions | 110 × 85 × 35 mm |
| Weight | 190 g (6.7 oz) |
| Housing Material | Anodized Aluminum |
| Operating Temperature | 0–60 °C |
| Measurement Range | −200 to 1300 °C |
| Accuracy | ±1 °C (±1.8 °F) |
| Battery Life | Up to 35 h (rechargeable Li-ion via USB-C) |
| Data Storage | 20 batches, 50,000 readings total |
| Sampling Interval | 1 s to 60 min (user-programmable) |
| Channels | 8 thermocouple inputs (Type K standard) |
| Display | Triple-color LED status indicators |
| Interface | USB-C (data export & charging) |
| Compliance | Qualicoat, GSB, ISO 9001, QIB, and ASTM D3003-22 (for thermal profiling in coating cure validation) |
| Brand | TQC Sheen |
|---|---|
| Origin | Netherlands |
| Model | Pendulum Hardness Tester |
| Compliance | ISO 1522:2005, NBN T22-105, BS 3900-E5 |
| Dimensions (closed) | 740 × 430 × 430 mm |
| Dimensions (open) | 960 × 430 × 650 mm |
| Weight | 26 kg |
| Housing | Powder-coated steel |
| Front panel & small components | Stainless steel |
| Left side panel | Anodized aluminum |
| Lid | Perspex acrylic (6 mm thick) |
| Power supply | 110 VAC, 50/60 Hz |
| Pendulum types supported | Persoz (SP0510), König (SP0505) |
| Pivot ball material | Tungsten carbide |
| Pivot ball diameters | 8 mm (Persoz), 5 mm (König) |
| Pivot spacing | 50 mm (Persoz), 30 mm (König) |
| Oscillation period | 1.0 s (Persoz), 1.4 s (König) |
| Initial deflection angle | 12° → 4° (Persoz), 6° → 3° (König) |
| Damping time on glass reference | 430 ± 15 s (Persoz), 250 ± 10 s (König) |
| Max sample size | 105 × 200 × 11 mm (Persoz), 105 × 200 × 8.3 mm (König) |
| Counting method | Time-based oscillation decay (vibration = time) |
| Total oscillations at endpoint | 179 ± 7 |
| Adjustable pendulum mass | 500 g / 200 g |
| Brand | TQC Sheen |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Dry/Wet Scrub Resistance Tester |
| Price | Upon Request |
| Brand | TQC Sheen |
|---|---|
| Origin | Netherlands |
| Model | SH0586-4500N, SH0590-4700N |
| Spray Nozzles | 12 |
| Adjustable Nozzle-to-Panel Distance | Yes |
| Spray Stroke Length | 400 mm (SH0586-4500N), 250/500 mm (SH0590-4700N) |
| Spray Pressure Range | 0.5–5 bar |
| Max Spray Area per Nozzle | 350 × 500 mm (SH0586-4500N), 500 × 500 mm (SH0590-4700N) |
| Traverse Speed | 20–800 mm/sec |
| Standard Panel Lift Between Coats | 40/50 mm |
| Flash-Off Timer Range | 0–10 min |
| Coat Counter Range | 1–9999 |
| Pass Counter Range | 1–9999 |
| Manual Spray Toggle & Traverse Control | Yes |
| Magnetic Panel Holder | Yes |
| Sample Capacity (100 × 150 mm) | 48 panels |
| Air Supply Requirement | 10 bar (150 psi), pneumatic |
| Dimensions (W × D × H, no options) | 70 × 72 × 160 cm (SH0586-4500N), 90 × 72 × 160 cm (SH0590-4700N) |
| Weight | 70 kg (SH0586-4500N), 90 kg (SH0590-4700N) |
| Compliance | ASTM D823/A |
| Brand | TQC Sheen |
|---|---|
| Origin | Netherlands |
| Model | SP1820 (Metric) / SP1822 (Imperial) |
| Dimensions (Unit) | 140 × 170 × 340 mm |
| Weight (Unit) | 4150 g |
| Max Panel Size | 150 × 100 mm |
| Max Panel Thickness | 1 mm |
| Mandrel Set Count | 14 (SP1820) / 7 (SP1822) |
| Mandrel Diameters | 2–32 mm (SP1820) / 1/8–1 in (SP1822) |
| Base Frame Dimensions | 100 × 130 × 160 mm |
| Load Arm Mass (with mandrel) | 2900 g (SP1820) / 1740 g (SP1822) |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SP4300 / SP4305 |
| Quotation | Upon Request |
| Punching Speed Range | 0.01–0.70 mm/s |
| Maximum Stroke | 0–12 mm |
| Test Panel Width | 100 mm |
| Steel Panel Thickness | 0.8 mm |
| Aluminum Panel Thickness | 1.2 mm |
| Dimensions (D×W×H) | 450 × 350 × 600 mm |
| Net Weight | ~31 kg |
| Power Consumption | 80 W |
| Display Resolution | 193 × 64 pixels |
| Backlight | Blue LED |
| Stroke Accuracy | ±0.01 mm |
| Speed Accuracy | ±1% of set value |
| Safety Features | Emergency Stop Button, Audible Alarm |
| Control Interface | Rotary Push-button Navigation, Multilingual On-screen Menu |
| Integrated LED Illumination System | Adjustable Angle, Intensity, and Color Temperature for Optimized Contrast |
| Brand | AiYao Instruments |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TRT |
| Pricing | Available Upon Request |
| Brand | VIALUX |
|---|---|
| Origin | Germany |
| Model | comsmart |
| Camera Resolution | 5.7 MP (standard), upgradable to 20 MP optics |
| Measurement Area (single capture) | 390 × 340 mm² |
| Node Processing Speed | 15,000 nodes/min |
| Calibration Time | ~3 min (fully automated) |
| Test Duration | 3–5 min |
| Strain Range | ≥100% (major/minor principal strain) |
| Output Formats | BMP, TIFF, PNG, JPG, VRML, PS, EPS (images) |
| Compliance | Designed for ISO/IEC 17025-aligned QA workflows, supports GLP/GMP traceability via audit-ready log export |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | YT-JNY |
| Price | USD 3,650 (approx.) |
| Measurement Range | 20–88 (arbitrary hardness units, calibrated per USP <1049> and Ph. Eur. 2.9.40 compliant soft capsule indentation scale) |
| Load Capacity Options | 50 N, 100 N, 500 N, or 1000 N |
| Resolution | 0.1 N |
| Accuracy | ±0.5% FS |
| Test Speed | 1–300 mm/min |
| Probe | Cylindrical, Ø10 mm or 10 mm² contact area |
| Upper Platen Parallelism | <0.025 mm |
| Lower Platen Diameter | 120 mm |
| Dimensions (W×D×H) | ~450 × 450 × 650 mm |
| Weight | 45 kg |
| Power Supply | 220 V, 50 Hz |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ZSH2090 |
| Price | Upon Request |
| Body Material | Stainless Steel |
| Dimensions (L×W×H) | 102 × 92 × 55 mm |
| Weight | 2.2 kg |
| Standards Compliance | ASTM D3363, ECCA T4, MIL-C-27227, NEN 5350, SIS 184187, SNV 37113 |
| Warranty | 24 months |
| Standard Kit | 1× tester unit, 1 set of 17 graded pencils (6B to 9H), 1× 400-grit abrasive paper, 1× carrying case |
| Optional Accessories | Pencil sharpener, replacement sandpaper, additional pencil sets |
| Manufacturer | Zehntner AG, Switzerland |
| Brand | Zehntner |
|---|---|
| Origin | Switzerland |
| Model | ZVL2190 |
| Compliance | DIN EN ISO 17872 |
| Cutting Tip Material | Tungsten Carbide |
| Overall Length | 150.50 mm |
| Diameter | Φ13.65 mm |
| Weight | 131 g |
| Warranty | 12 months |
| Brand | ZEPTOOLS |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Origin Category | Domestic (China) |
| Model | SEM Cryogenic Vacuum Transfer System |
| Pricing | Upon Request |
| Cooling Stage Temperature Range | −170 °C to +100 °C |
| Cooling Stage Temperature Stability | ≤ ±0.1 °C |
| Cooling Stage Rotation | 0–360° continuous |
| Cooling Stage Tilt Angle | ≥55° |
| Cold Trap Temperature | ≤ −190 °C |
| Cold Trap Temperature Stability | ≤ ±0.5 °C |
| Cooling Stage Cool-down Time to −170 °C | ≤35 min |
| Cold Trap Cool-down Time to −190 °C | ≤20 min |
| Bake-out Capability | ≥100 °C |
| Liquid Nitrogen Capacity | 35 L |
| Continuous Operation Duration | >8 h |
| LN₂ Refill Port | Hot-swap compatible (no system shutdown required) |
| Vacuum Transfer Chamber | Enables glovebox ↔ FIB ↔ SEM cryo-transfer |
| Vacuum Load Lock | Integrated for rapid, contamination-controlled SEM insertion |
| Control System | Integrated PLC-based HMI with real-time temperature/vacuum monitoring and logging |
| Brand | Zhonghang Dingli |
|---|---|
| Origin | Beijing, China |
| Model | LJD Series Direct-Reading |
| Measurement Principle | Resonant Frequency Shift Method (Q-Meter Based) |
| Frequency Range | 10 kHz – 10 MHz (typical for LJD-B/C variants) |
| Capacitance Measurement Range | 0.1 pF – 2.5 µF (LJD-B), 0.1 pF – 25 nF (LJD-C) |
| Resolution | 0.1 pF |
| Dielectric Loss Tangent (tan δ) Accuracy | ±0.0001 (at optimal Q > 100) |
| Compliance | Designed per GB/T 1409–2006 (Chinese national standard equivalent to IEC 60250), supports ASTM D150 and ISO 257-1/2 test methodologies |
| Brand | Zhonghang Dingli |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | LJD-C |
| Price | USD 3,950 (FOB Beijing) |
| Brand | Zhonghang Dingli |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | LJD-C High-Frequency Dielectric Constant Analyzer |
| Price | USD 3,500 (FOB Beijing) |
| Brand | ZKWN |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZKWP-A |
| Price | USD 2,150 (FOB Beijing) |
| Heating Method | Electric Resistance Heating |
| Cooling Method | Liquid Nitrogen Cryogenic Cooling |
| Temperature Control Accuracy | ±0.5 °C |
| Temperature Range | −30 °C to +200 °C |
| Electrode Material | Brass |
| Electrode Diameter | 25 mm |
| Test Frequency Range | 20 Hz to 2 MHz |
| Compliance | GB/T 1409–2006, GB/T 1693–2007, ASTM D150, IEC 60250 |
| Brand | Aerospace Vertical |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZJD-C Dielectric Constant and Dissipation Factor Tester |
| Price Range | USD 4,200 – 8,400 (FOB) |
| Frequency Range | 10 kHz – 70 MHz / 100 kHz – 160 MHz |
| Core Components | Q-meter main unit, precision parallel-plate or coaxial fixture, calibrated inductors |
| Standards Compliance | GB/T 1409–2006, GB/T 5594.4–2015, GB/T 1693–2007 |
| Primary Applications | Dielectric constant (ε′), loss factor (ε″), dissipation factor (tan δ), and complex permittivity characterization of solid and liquid insulating materials |