Ozone Aging Test Chamber
Filter
Showing 1–30 of 40 results
| Brand | Anseros |
|---|---|
| Origin | Germany |
| Model | SIM 6010T |
| Temperature Range | 26–60 °C (standard), 15–70 °C (extended) |
| Humidity Range | 30–80 % RH |
| Ozone Concentration Control Range | 20–200 pphm |
| Ozone Measurement Principle | Non-dispersive UV absorption |
| Ozone Measurement Range | 0–100 / 1,000 / 10,000 pphm |
| Detection Limit | 1 pphm |
| Response Time | 5 s |
| Accuracy | ±0.2 % of reading (ozone sensor) |
| Airflow Velocity in Chamber | 600 mm/s |
| Air Exchange Rate | 400 L/h |
| Recovery Time to 95 % Set Ozone Level | ≤10 min |
| Recovery Rate | 0.4 K/min |
| Temperature Compensation | Automatic, 0–60 °C ±1 °C |
| Pressure Compensation | Automatic, 600–1500 mbar ±2 mbar |
| Zero Drift | Auto-zeroing cycle every 2 s |
| Span Drift | None (single-beam optical design) |
| Power Supply | 230 V / 50 Hz |
| External Dimensions | 950 × 870 × 610 mm |
| Usable Internal Volume | 680 × 650 × 400 mm |
| Generator/Controller/Detector Cabinet | 1600 × 550 × 600 mm |
| Brand | Anseros |
|---|---|
| Origin | Germany |
| Model | SIM 6050-T |
| Temperature Range | 15–70 °C (RT = 23 °C) |
| Humidity Range | 30–80 % RH |
| Ozone Concentration Control Range | 20–200 pphm |
| Ozone Measurement Principle | Non-dispersive UV absorption |
| Ozone Detection Limit | 1 pphm |
| Response Time | 5 s |
| Temperature Accuracy | ±5 K |
| Humidity Accuracy | −1 to +4 % RH |
| Airflow Velocity in Test Chamber | 600 mm/s |
| Air Exchange Rate | 400 L/h |
| Chamber Internal Dimensions | 425 × 460 × 270 mm |
| External Dimensions | 670 × 620 × 510 mm |
| Power Supply | 230 V / 50 Hz |
| Brand | Anseros |
|---|---|
| Origin | Germany |
| Model | SIM 6300 |
| Ozone Measurement Principle | Non-dispersive UV absorption |
| Ozone Range | 0–100 / 1,000 / 10,000 pphm |
| Response Time | 5 s |
| Detection Limit | 1 pphm |
| Accuracy | ±0.2% of reading |
| Repeatability | ±0.2% of full scale |
| Temperature Control Range | 15–70 °C (RT = 23 °C) |
| Temp. Accuracy | ±5 K |
| Temp. Ramp Rate | 0.4 K/min |
| Humidity Range | 30–80% RH |
| Humidity Accuracy | –1 to +4% RH |
| Humidity Stabilization Time to 95% | ≤20 min |
| Ozone Control Range | 20–200 pphm |
| Ozone Control Accuracy | ±1 pphm |
| Ozone Stabilization Time to 95% | 10 min |
| Airflow Velocity in Chamber | 600 mm/s |
| Air Exchange Rate | 400 L/h |
| Chamber Internal Dimensions | 680 × 650 × 400 mm |
| External Dimensions | 950 × 870 × 610 mm |
| Power Supply | 230 V / 50 Hz |
| Brand | Anseros |
|---|---|
| Origin | Germany |
| Model | SIM 7500 |
| Temperature Range | 26–60 °C (RT = 23 °C) |
| Humidity Range | 30–80 % RH |
| Ozone Concentration Control Range | 20–200 pphm |
| Ozone Measurement Principle | Non-dispersive ultraviolet (NDUV) absorption |
| Ozone Detection Limit | 1 pphm |
| Response Time | 5 s |
| Temperature Accuracy | ±5 K |
| Humidity Accuracy | −1 to +4 % RH |
| Airflow Velocity | 600 mm/s |
| Air Exchange Rate | 400 L/h |
| Chamber Internal Dimensions | 425 × 460 × 270 mm (standard) |
| Power Supply | 230 V / 50 Hz |
| Brand | ANSEROS |
|---|---|
| Origin | Germany |
| Model | SIM 8000 |
| Chamber Volume | 8000 L |
| Temperature Range | 15–70 °C (RT = 23 °C) |
| Humidity Range | 30–80 % RH |
| Ozone Concentration Control | 20–200 pphm |
| Ozone Measurement Principle | Non-dispersive UV Absorption |
| Ozone Detection Limit | 1 pphm |
| Response Time | 5 s |
| Accuracy | ±1 pphm (ozone), ±5 K (temperature), −1 to +4 % RH (humidity) |
| Airflow Velocity in Test Zone | 600 mm/s |
| Air Exchange Rate | 400 L/h |
| Power Supply | 230 V / 50 Hz |
| Brand | ANSEROS |
|---|---|
| Origin | Germany |
| Model | SIM-6300 |
| Internal Dimensions | 680 × 680 × 500 mm |
| External Dimensions | 1610 × 1500 × 1000 mm |
| Gas Flow Velocity | 8–700 mm/s |
| Air Exchange Rate | 50–500 L/min |
| Air Replacement Rate | 1–2000 dm³/h (33 L/min) |
| Temperature Range | RT to 70 °C ±0.5 °C |
| Humidity Range | 30–90 %RH (±1/+4 %RH) |
| Ozone Measurement Principle | Single-beam NDUV Photometry |
| Ozone Concentration Range | 0–1999 mg O₃/Nm³ or 0–1000 ppmv |
| Sensitivity | 0.001 ppmv |
| Accuracy | <1 % SCE |
| Linearity | 98 % SCE |
| Ozone Generation Method | Corona Discharge (COM-ADM) |
| Ozone Output Capacity | 10–2000 mg/h |
| Ozone Flow Rate | 100–2000 NL/h |
| Power Consumption | 3000 W |
| Voltage | 230 V, 10 A |
| Weight | 250 kg |
| Compliant Standards | ASTM D1149, ASTM D2802, ASTM D4246-02, ASTM D4575, ASTM D470, ASTM D518, BS 903 A43, DIN 53509-2-1, FORD FLTM BP101-01, GB/T 11206-2009, GB/T 13642-1992, GB/T 2951.1–2951.10-1997, GB/T 2951.21-2008, GB/T 7762-2003, HG/T 2716-2008, HG/T 2869-1997, ISO 1431-1 & -3, MIL-STD-1344A, NGF 37112, SAE J1401, SIS 16 12 10 |
| Brand | Anseros |
|---|---|
| Origin | Germany |
| Model | SIM6200-T-CL |
| Chamber Volume | 230 L |
| Internal Dimensions (H×W×L) | 50 × 68 × 68 cm |
| Total Dimensions (H×W×L) | 181 (+43) × 99 × 120 (+10) cm |
| Weight | 400 kg |
| Power Supply | 230/120 VAC, 50/60 Hz |
| Ozone Concentration Range | 0–1000 pphmv |
| Airflow Velocity (in chamber) | 8–16 mm/s (longitudinal, laminar flow) |
| Reynolds Number (Re) | 300–1000 |
| Loading Factor | G = 12 s/m (per ISO 1431-1) |
| Certified Ozone Analyzer | MP60602 |
| Ozone Generator | Maintenance-Free Type |
| Control System | Siemens SIMATIC S7-300 PLC with 15″ Touchscreen HMI |
| Data Interface | RS232, USB |
| Safety Features | Catalytic ozone destruct, activated carbon filter, turbofan recirculation, interlocked safety door, audible/visual alarms |
| Compliance | ASTM D1149, ISO 1431-1, DIN ISO 1431-1 |
| Brand | ANSEROS |
|---|---|
| Origin | Germany |
| Model | SIM6300-T-CL |
| Compliance | ASTM D1149, ISO 1431-1, DIN ISO 1431-1 |
| Ozone Generation | Maintenance-free corona discharge generator |
| Ozone Monitoring | Certified ozone analyzer (MP series) with closed-loop feedback control |
| Control System | Programmable logic controller (PLC) with interrupt-resume functionality for long-term durability testing |
| Air Circulation | Recirculating turbojet system integrated with catalytic ozone destruct unit and activated carbon filter |
| Sample Mounting | Dual-mode fixture—static test racks and dynamic rotating sample disc (4-position V-groove clamping) |
| Data Interface | RS232 serial port for real-time logging to ANSEROS on-board monitoring software |
| Chamber Configuration | Climate-controlled enclosure with temperature stabilization (ambient to +70 °C, ±0.5 °C uniformity) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Ozone Concentration Range | 50–1500 ppm (pphm) |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65% RH |
| Temperature Uniformity | ±0.5 °C |
| Sample Rotation Speed | 1 rpm (360° continuous rotation) |
| Gas Flow Velocity | 8–16 mm/s |
| Compliance Standards | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Control System | Siemens PLC + Weintek Color Touchscreen HMI |
| Ozone Generation | Silent Discharge Tube |
| Ozone Detection | Non-Dispersive UV Absorption Analyzer (≥5 yr service life) |
| Safety Features | Leakage protection, short-circuit cutoff, overtemperature shutdown, motor thermal overload protection |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | HD-E801 |
| Ozone Concentration Range | 50–1000 pphm |
| Ozone Control Accuracy | ±10 pphm (50–100 pphm), ±10% (100–1000 pphm) |
| Temperature Range | 20–60 °C |
| Temperature Uniformity | ±2 °C (empty chamber) |
| Temperature Stability | ±0.5 °C |
| Humidity Range | 30–98 %RH |
| Airflow Rate | 100 L/min |
| Internal Dimensions | 400 × 500 × 500 mm (D×W×H) |
| External Dimensions | 950 × 980 × 1650 mm (D×W×H) |
| Net Volume | 800 L |
| Dynamic Sample Rotation Speed | 2–10 rpm (adjustable) |
| Vertical Extension Frequency | 2–15 cycles/min |
| Extension Stroke | 20–100 mm (adjustable) |
| Refrigerant | R404a |
| Compressor | Hermetic French Tecumseh unit |
| Heating System | SUS304 U-shaped finned tubular heater (1500 W) |
| Humidification System | SUS304 U-shaped humidifier |
| Ozone Generator | Silent high-voltage corona discharge type |
| Ozone Sensor | Electrochemical sensor |
| Controller | TEMP880 high-precision color touchscreen PID controller with USB/RS232/RS485 interfaces |
| Compliance Standards | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 2951.5–1997 |
| Brand | JianHu |
|---|---|
| Origin | Shanghai, China |
| Model | JH-Ozone Aging Test Chamber |
| Temperature Range | Ambient to 70 °C |
| Ozone Concentration Range | 0–1000 pphm (adjustable with UV ozone generator) |
| Humidity Control | Optional RH 20–98% (±3% RH) |
| Chamber Volume | 100–1000 L (customizable) |
| Compliance | ISO 1431-1, ASTM D1149, GB/T 7762, IEC 60811-501 |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JH-OZ-XE Series |
| Price Range | USD 500 – 48,000 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | OK-CY-100 |
| Temperature Range | 25–80 °C |
| Humidity Range | 30–65 %RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temperature Uniformity | ±0.5 °C |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | 7-inch color touchscreen + Siemens PLC |
| Ozone Generation | Silent discharge tube |
| Ozone Detection | Non-dispersive UV absorption sensor (≥5 yr lifespan) |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-CY-100 |
| Price | USD 4,950 (FOB Guangdong) |
| Ozone Concentration Range | 0.01–100 ppm |
| Control Accuracy | ±5% of setpoint (closed-loop PID) |
| Temperature Range | 20–60 °C (±1 °C stability) |
| Humidity Range | 30–80% RH (±3% RH stability) |
| Static Stretch Range | 5–40% |
| Dynamic Stretch Frequency | 0–0.5 Hz |
| Chamber Volume | 100 L |
| Exhaust Treatment | Activated Carbon + UV Photolysis |
| Compliance | GB/T 7762-2014, ISO 1431-1:2004, ASTM D1149-19, SAE J1201-2018 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | OK-QY-100 |
| Ozone Concentration Range | 50–1500 ppm (pphm) |
| Temperature Range | 25–40 °C |
| Temperature Uniformity | ±0.5 °C |
| Humidity Range | 30–65 % RH |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Siemens PLC + Weintek color touchscreen HMI |
| Ozone Detection | Non-dispersive UV absorption analyzer (≥5 yr service life) |
| Compliance Standards | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | OK-QY-100 |
| Price | USD 6,300 (FOB) |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temperature Uniformity | ±0.5 °C |
| Sample Rack Rotation | 1 rpm (360° continuous) |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Siemens PLC + Weintek Color Touchscreen HMI |
| Ozone Generation | Silent Discharge Tube |
| Ozone Detection | Non-Dispersive UV Absorption Analyzer (≥5 yr lifespan) |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Key Features | Stainless steel sealed test chamber |
|---|---|
| Ozone concentration range | 50–1500 ppm (pphm) |
| Temperature range | 25–40 °C |
| Humidity range | 30–65 %RH |
| Temp. uniformity | ±0.5 °C |
| Sample rotation | 360°, 1 rpm |
| Gas flow velocity | 8–16 mm/s |
| Compliance with GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1 | 2004 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Ozone Concentration Range | 50–1500 ppm (pphm) |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Temp. Uniformity | ±0.5 °C |
| Sample Rack | 360° Rotational (1 rpm), Static or Dynamic Mode Optional |
| Ozone Generation | Silent Discharge Tube |
| Ozone Detection | Nondispersive UV Absorption Analyzer (≥5 yr lifespan) |
| Control System | Weilun Color Touchscreen + Siemens PLC |
| Output/Interface | 4–20 mA analog output, RS232 communication port |
| Safety Protection | Leakage current, short-circuit, overtemperature, motor overheat, and overcurrent protection |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz |
| Key Specifications | Brand: OEM / Industrial Grade |
|---|---|
| Origin | Imported |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 %RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temp. Uniformity | ±0.5 °C |
| Sample Rotation Speed | 1 rpm (360° continuous) |
| Gas Flow Velocity | 8–16 mm/s |
| Ozone Generation | Silent Discharge Tube |
| Ozone Detection | Nondispersive UV Absorption Analyzer (≥5 yr service life) |
| Control System | Weilun Color Touchscreen + Siemens PLC |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Safety | Fully Enclosed Ozone Loop, Leakage Protection, Over-Temp/Over-Current/Motor Thermal Cut-off |
| Interface | 4–20 mA analog output, RS232 communication port |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz |
| Key Features | Stainless steel test chamber |
|---|---|
| ASTM D1149 / ISO 1431-1 | 2004 / GB/T 7762–2003 compliant design |
| Gas flow velocity | 8–16 mm/s |
| Key | Brand: OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 6,300 (FOB ex-works |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C ±0.5 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm (parts per hundred million) |
| Ozone Generation Method | Silent Discharge Tube |
| Ozone Monitoring | Non-Dispersive UV Absorption Analyzer (≥5 yr service life) |
| Control System | Weilun Color Touchscreen + Siemens PLC |
| Sample Motion | Static or Dynamic (360° rotation at 1 rpm, cycloidal trajectory compliant) |
| Gas Flow Velocity | 8–16 mm/s |
| Compliance Standards | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Safety Features | Leak-proof closed-loop ozone circulation, over-temperature, over-current, motor thermal, and short-circuit protection |
| Interface | RS232 communication port, 4–20 mA analog output, metrology calibration port |
| Key Features | Stainless steel test chamber |
|---|---|
| Humidity control | 30–65% RH |
| Rotating sample rack | 1 rpm, 360° continuous rotation |
| Gas flow velocity | 8–16 mm/s |
| Compliant with GB/T 7762-2003, GB/T 2951.21-2008, GB/T 11206-2009, ISO 1431-1 | 2004 |
| Electrical supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Key Features | Stainless steel test chamber |
|---|---|
| Ozone concentration range | 50–1500 ppm (pphm) |
| Temperature range | 25–40 °C, ±0.5 °C stability |
| Humidity range | 30–65 % RH |
| Sample rack rotation | 360°, 1 rpm |
| Gas flow velocity | 8–16 mm/s |
| Compliance with GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1 | 2004 |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temperature Uniformity | ±0.5 °C |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Siemens PLC + Weintek color touchscreen HMI |
| Ozone Generation | Silent discharge tube |
| Ozone Detection | Non-dispersive UV absorption analyzer (≥5-year service life) |
| Compliance Standards | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Ozone Concentration Range | 50–1500 ppm (pphm) |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Temp. Uniformity | ±0.5 °C |
| Sample Rotation Speed | 1 rpm (360° continuous rotation) |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Siemens PLC + Weintek Color Touchscreen HMI |
| Ozone Generation | Silent Discharge Tube |
| Ozone Detection | Non-Dispersive UV Absorption Analyzer (≥5 yr service life) |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Safety Features | Leakage/short-circuit/overheat/motor-overcurrent protection |
| Interface | 4–20 mA analog output, RS232 communication port |
| Calibration Port | Integrated metrology interface |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 6,300 (FOB) |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 %RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temp. Uniformity | ±0.5 °C |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Weilun color touchscreen + Siemens S7-1200 PLC |
| Ozone Sensor | Non-dispersive UV absorption type, ≥5-year service life |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 6,200 (FOB Shanghai, ex-works reference only) |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C |
| Temp. Uniformity | ±0.5 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Ozone Generation Method | Silent Discharge Tube |
| Ozone Monitoring | Non-Dispersive UV Absorption Analyzer (Lifespan ≥5 years) |
| Sample Rotation | 360° motorized turntable, 1 rpm (static/dynamic test modes optional) |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Weilun color touchscreen + Siemens S7-1200 PLC |
| Communication Interface | RS232, 4–20 mA analog output |
| Safety Protections | Leakage current, short-circuit, overtemperature, motor overheat, overcurrent |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 6,300 (approx.) |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 %RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temp. Uniformity | ±0.5 °C |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Weilun color touchscreen + Siemens PLC |
| Ozone Generation | Silent discharge tube |
| Ozone Detection | Nondispersive UV absorption sensor (≥5 yr lifespan) |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 6,300 (FOB) |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Ozone Control Accuracy | ±10 pphm |
| Temperature Uniformity | ±0.5 °C |
| Sample Rotation | 360° continuous, 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Ozone Generation | Silent Discharge Tube |
| Ozone Detection | Non-Dispersive UV Absorption Analyzer (Lifespan ≥5 years) |
| Control System | Weilun Color Touchscreen + Siemens PLC |
| Compliance Standards | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |