| Key Features | Stainless steel sealed test chamber |
|---|---|
| Ozone concentration range | 50–1500 ppm (pphm) |
| Temperature range | 25–40 °C |
| Humidity range | 30–65 %RH |
| Temp. uniformity | ±0.5 °C |
| Sample rotation | 360°, 1 rpm |
| Gas flow velocity | 8–16 mm/s |
| Compliance with GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1 | 2004 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Ozone Concentration Range | 50–1500 ppm (pphm) |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Temp. Uniformity | ±0.5 °C |
| Sample Rack | 360° Rotational (1 rpm), Static or Dynamic Mode Optional |
| Ozone Generation | Silent Discharge Tube |
| Ozone Detection | Nondispersive UV Absorption Analyzer (≥5 yr lifespan) |
| Control System | Weilun Color Touchscreen + Siemens PLC |
| Output/Interface | 4–20 mA analog output, RS232 communication port |
| Safety Protection | Leakage current, short-circuit, overtemperature, motor overheat, and overcurrent protection |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz |
| Key Specifications | Brand: OEM / Industrial Grade |
|---|---|
| Origin | Imported |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 %RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temp. Uniformity | ±0.5 °C |
| Sample Rotation Speed | 1 rpm (360° continuous) |
| Gas Flow Velocity | 8–16 mm/s |
| Ozone Generation | Silent Discharge Tube |
| Ozone Detection | Nondispersive UV Absorption Analyzer (≥5 yr service life) |
| Control System | Weilun Color Touchscreen + Siemens PLC |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Safety | Fully Enclosed Ozone Loop, Leakage Protection, Over-Temp/Over-Current/Motor Thermal Cut-off |
| Interface | 4–20 mA analog output, RS232 communication port |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz |
| Key Features | Stainless steel test chamber |
|---|---|
| ASTM D1149 / ISO 1431-1 | 2004 / GB/T 7762–2003 compliant design |
| Gas flow velocity | 8–16 mm/s |
| Key | Brand: OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 6,300 (FOB ex-works |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C ±0.5 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm (parts per hundred million) |
| Ozone Generation Method | Silent Discharge Tube |
| Ozone Monitoring | Non-Dispersive UV Absorption Analyzer (≥5 yr service life) |
| Control System | Weilun Color Touchscreen + Siemens PLC |
| Sample Motion | Static or Dynamic (360° rotation at 1 rpm, cycloidal trajectory compliant) |
| Gas Flow Velocity | 8–16 mm/s |
| Compliance Standards | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Safety Features | Leak-proof closed-loop ozone circulation, over-temperature, over-current, motor thermal, and short-circuit protection |
| Interface | RS232 communication port, 4–20 mA analog output, metrology calibration port |
| Key Features | Stainless steel test chamber |
|---|---|
| Humidity control | 30–65% RH |
| Rotating sample rack | 1 rpm, 360° continuous rotation |
| Gas flow velocity | 8–16 mm/s |
| Compliant with GB/T 7762-2003, GB/T 2951.21-2008, GB/T 11206-2009, ISO 1431-1 | 2004 |
| Electrical supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Key Features | Stainless steel test chamber |
|---|---|
| Ozone concentration range | 50–1500 ppm (pphm) |
| Temperature range | 25–40 °C, ±0.5 °C stability |
| Humidity range | 30–65 % RH |
| Sample rack rotation | 360°, 1 rpm |
| Gas flow velocity | 8–16 mm/s |
| Compliance with GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1 | 2004 |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temperature Uniformity | ±0.5 °C |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Siemens PLC + Weintek color touchscreen HMI |
| Ozone Generation | Silent discharge tube |
| Ozone Detection | Non-dispersive UV absorption analyzer (≥5-year service life) |
| Compliance Standards | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Ozone Concentration Range | 50–1500 ppm (pphm) |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Temp. Uniformity | ±0.5 °C |
| Sample Rotation Speed | 1 rpm (360° continuous rotation) |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Siemens PLC + Weintek Color Touchscreen HMI |
| Ozone Generation | Silent Discharge Tube |
| Ozone Detection | Non-Dispersive UV Absorption Analyzer (≥5 yr service life) |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Safety Features | Leakage/short-circuit/overheat/motor-overcurrent protection |
| Interface | 4–20 mA analog output, RS232 communication port |
| Calibration Port | Integrated metrology interface |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 6,300 (FOB) |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 %RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temp. Uniformity | ±0.5 °C |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Weilun color touchscreen + Siemens S7-1200 PLC |
| Ozone Sensor | Non-dispersive UV absorption type, ≥5-year service life |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 6,200 (FOB Shanghai, ex-works reference only) |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C |
| Temp. Uniformity | ±0.5 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Ozone Generation Method | Silent Discharge Tube |
| Ozone Monitoring | Non-Dispersive UV Absorption Analyzer (Lifespan ≥5 years) |
| Sample Rotation | 360° motorized turntable, 1 rpm (static/dynamic test modes optional) |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Weilun color touchscreen + Siemens S7-1200 PLC |
| Communication Interface | RS232, 4–20 mA analog output |
| Safety Protections | Leakage current, short-circuit, overtemperature, motor overheat, overcurrent |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 6,300 (approx.) |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 %RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temp. Uniformity | ±0.5 °C |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Weilun color touchscreen + Siemens PLC |
| Ozone Generation | Silent discharge tube |
| Ozone Detection | Nondispersive UV absorption sensor (≥5 yr lifespan) |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 6,300 (FOB) |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Ozone Control Accuracy | ±10 pphm |
| Temperature Uniformity | ±0.5 °C |
| Sample Rotation | 360° continuous, 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Ozone Generation | Silent Discharge Tube |
| Ozone Detection | Non-Dispersive UV Absorption Analyzer (Lifespan ≥5 years) |
| Control System | Weilun Color Touchscreen + Siemens PLC |
| Compliance Standards | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 6,300 (approx.) |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 %RH |
| Ozone Concentration | 50–1500 pphm |
| Temp. Uniformity | ±0.5 °C |
| Sample Rack | 360° rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Weilun color touchscreen + Siemens PLC |
| Ozone Sensor | Nondispersive UV absorption type, ≥5-year service life |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 6,300 (FOB) |
| Standards Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 %RH |
| Ozone Concentration Range | 50–1500 ppm (pphm) |
| Temp. Uniformity | ±0.5 °C |
| Sample Rotation | 360° continuous, 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Ozone Generation | Silent Discharge Tube |
| Detection Method | Non-Dispersive UV Absorption |
| Sensor Lifetime | ≥5 years |
| Control System | Weilun Color Touchscreen + Siemens S7-1200 PLC |
| Output Interface | 4–20 mA analog, RS232 serial |
| Safety Protections | Leakage current, short-circuit, overtemperature, motor overheat, overcurrent |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 6,300 (approx.) |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temp. Uniformity | ±0.5 °C |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Ozone Generation | Silent Discharge Tube |
| Ozone Detection | Non-Dispersive UV Absorption Analyzer (≥5 yr lifespan) |
| Control System | Weilun Color Touchscreen + Siemens PLC |
| Compliance Standards | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 6,200 (approx.) |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Ozone Generation Method | Silent Discharge Tube |
| Ozone Monitoring | Non-Dispersive UV Sensor (≥5 yr lifespan) |
| Control System | Siemens PLC + Weintek Color Touchscreen |
| Temperature Stability | ±0.5 °C |
| Sample Rotation | 360° motorized rack, 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Compliance Standards | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Key | Brand: OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 6,300 (FOB) |
| Chamber Volume | 80 L / 225 L / 500 L / 1000 L |
| Internal Dimensions (W×H×D, cm) | 40×50×40 |
| External Dimensions (W×H×D, cm) | 100×170×90 |
| Temperature Range | 25–40 °C |
| Temp. Uniformity | ±0.5 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Ozone Generation Method | Silent Discharge Tube |
| Ozone Monitoring | Imported UV Absorption Analyzer with 4–20 mA Output & RS232 Interface |
| Sample Rack | Motor-Driven, 360° Continuous Rotation (1 rpm), Cycloidal Trajectory Compliance |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Weintek Color Touchscreen + Siemens S7-1200 PLC |
| Safety Protections | Leakage Current, Short-Circuit, Over-Temperature, Motor Overheat, Over-Current |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Ozone Concentration Range | 50–1500 ppm (pphm) |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Temp. Uniformity | ±0.5 °C |
| Sample Mounting | Dynamic (360° rotation at 1 rpm) & Static options |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Siemens PLC + Weintek Color Touchscreen |
| Ozone Detection | Non-dispersive UV Sensor (≥5 yr lifespan) |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Ozone Concentration Range | 50–1500 ppmv (pphm) |
| Temperature Range | 25–40 °C |
| Temperature Uniformity | ±0.5 °C |
| Humidity Range | 30–65 % RH |
| Sample Rack Rotation | 360° continuous, 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Ozone Generation Method | Silent Discharge Tube |
| Ozone Detection | Non-Dispersive UV Absorption Analyzer (≥5 yr service life) |
| Control System | Weilun Color Touchscreen + Siemens PLC |
| Compliance Standards | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 6,300 (FOB) |
| Standards Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 %RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temp. Uniformity | ±0.5 °C |
| Ozone Generation | Silent Discharge Tube |
| Ozone Detection | Non-Dispersive UV Absorption Analyzer (Lifespan ≥5 yr) |
| Sample Rotation | 360° motorized rack, 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Weilun color touchscreen + Siemens S7-1200 PLC |
| Safety Protections | Leakage, short-circuit, over-temperature, motor overheat, over-current |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QJCYX-54 |
| Price Range | USD 4,900 – 7,000 |
| Temperature Range | 0°C to 60°C |
| Humidity Range | 40–98% RH (at 30–60°C) |
| Temperature Uniformity | ≤ ±2°C |
| Temperature Stability | ≤ ±0.5°C |
| Humidity Stability | +2 / −3% RH |
| Heating Rate | 0.7–1.0°C/min |
| Cooling Rate | ≤20 min (from ambient to 10°C, non-restricted) |
| Ozone Concentration Range | 10–1,000 pphm |
| Gas Flow Velocity | 12–16 mm/s |
| Sample Mounting | Static Rack |
| Compliance | GB/T 7762–2003, GB/T 3642–1992 |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJCYX-542 |
| Temperature Range | 0–60 °C |
| Humidity Range | 40–98% RH (at 30–60 °C) |
| Temperature Uniformity | ≤±2 °C |
| Temperature Stability | ≤±0.5 °C |
| Humidity Stability | +2 / −3% RH |
| Heating Rate | 0.7–1.0 °C/min |
| Cooling Rate | ≤20 min (from ambient to 10 °C, non-restricted) |
| Ozone Concentration Range | 10–1000 pphm |
| Gas Flow Velocity | 12–16 mm/s |
| Compliance | GB/T 7762–2003, GB/T 3642–1992 |
| [Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Ozone Concentration Range | 50–1500 ppmv (pphm) |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65% RH |
| Temp. Uniformity | ±0.5 °C |
| Chamber Volumes | 80 L / 225 L / 500 L / 1000 L |
| Sample Rotation | Static or Optional 360° Rotating Rack (1 rpm) |
| Ozone Generation | Silent Discharge Tube |
| Ozone Detection | Nondispersive UV Absorption Analyzer (≥5 yr service life) |
| Control System | Siemens PLC + Weintek HMI Touchscreen |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004] |
| Brand | Tuofeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | TF-312C |
| Price Range | USD 7,000 – 14,000 |
| Internal Dimensions (W×D×H, mm) | 450×450×500 / 500×600×750 / 700×800×900 / 800×1000×1000 |
| External Dimensions (W×D×H, mm) | 1200×1000×1800 / 1300×1150×2050 / 1450×1400×2250 / 1520×1540×2300 |
| Power Consumption | 4.0 kW / 4.5 kW / 7.0 kW / 11.5 kW |
| Temperature Range | 0°C to 70°C |
| Humidity Range | 30–65% RH |
| Ozone Concentration Range | 50–500 pphm (parts per hundred million) |
| Temperature Uniformity | ±0.5°C |
| Sample Rack | 360° continuous rotation at 1 rpm (static mode optional) |
| Gas Flow Velocity | 12–16 mm/s |
| Temperature Controller | Imported LED digital P.I.D. + S.S.R. microcomputer-integrated controller |
| Timer | High-precision programmable timer (hour/minute/second) |
| Ozone Monitoring | Imported ozone concentration analyzer with 4–20 mA analog output and RS232 communication interface |
| Ozone Generator Type | Silent corona discharge tube or UV absorption type (optional) |
| Safety Protections | Leakage current protection, short-circuit protection, overtemperature cutoff, motor overheat protection, overcurrent protection |
| Brand | Tuofeng |
|---|---|
| Model | TF-312 |
| Chamber Internal Dimensions (W×D×H, mm) | 450×450×500 / 500×600×750 / 700×800×900 / 800×1000×1000 |
| External Dimensions (W×D×H, mm) | 1200×1000×1800 / 1300×1150×2050 / 1450×1400×2250 / 1520×1540×2300 |
| Temperature Range | 0°C to 70°C |
| Temperature Uniformity | ±0.5°C |
| Relative Humidity Range | 30–65% RH |
| Ozone Concentration Range | 50–500 pphm |
| Sample Rack Rotation | 360° continuous, 1 rpm |
| Gas Flow Velocity | 12–16 mm/s |
| Control System | Imported LED digital P.I.D. + S.S.R. microcomputer controller |
| Timer Resolution | 0.1 s (hour/minute/second) |
| Ozone Monitoring | Imported ozone concentration analyzer with 4–20 mA analog output and RS232 interface |
| Ozone Generator Type | Silent discharge tube or UV absorption (optional) |
| Safety Protections | Leakage protection, short-circuit protection, overtemperature cutoff, motor overheat protection, overcurrent protection |
| Power Consumption | 4.0 kW / 4.5 kW / 7.0 kW / 11.5 kW (model-dependent) |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008 |
| Brand | Yuelian / PW |
|---|---|
| Origin | Guangdong, China |
| Model | PW-CYO-150 |
| Internal Dimensions (D×W×H) | 500×500×600 mm |
| Temperature Range | 0–70°C |
| Humidity Range | 40–98% RH |
| Temperature Uniformity | ≤±2°C |
| Temperature Stability | ≤±0.5°C |
| Temperature Deviation | ≤±1.5°C |
| Humidity Fluctuation | +2 / −3% RH |
| Heating Rate | 0.7–1.0°C/min |
| Cooling Rate | ≤20 min (from ambient to 10°C, non-restricted) |
| Ozone Concentration Range | 10–500 pphm or 500–1000 pphm (selectable) |
| Gas Flow Velocity | 12–16 mm/s |
| Sample Rack | Static or dynamic tensile rack (customer-specified at order) |
| Rack Rotation Speed | 1 rpm (360° continuous rotation) |
| Timer Range | 0–9999 hours |
| Power Supply | AC 380 V ±10%, 50 Hz, 3-phase 5-wire |
| Ozone Sensor | Imported UK CT electrochemical sensor |
| Ozone Measurement Accuracy | ≤±5% F.S. |
| Ozone Control Signal Output | 4–20 mA |
| Ozone Generator Type | Silent discharge tube (air-fed, wind-cooled) |
| Compliance Standards | GB/T 7762–2003 (static), GB/T 13642–1992 (dynamic) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ZLHS-150-CY |
| Price | USD 5,400 (FOB Shanghai) |
| Internal Chamber Dimensions (W×H×D) | 500 × 600 × 500 mm |
| External Dimensions | 700 × 1720 × 1480 mm |
| Power Consumption | 4.0 kW |
| Temperature Range | 0–70 °C |
| Temperature Uniformity | ±0.5 °C |
| Humidity Range | 30–65 %RH |
| Ozone Concentration Range | 50–500 pphm (parts per hundred million) |
| Gas Flow Velocity | 12–16 mm/s |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Ozone Generation | Silent discharge tube type (standard), UV absorption type optional |
| Ozone Monitoring | QUA non-dispersive UV ozone analyzer (trace-level accuracy per ISO 1431-1) |
| Measurement Principle | Beer-Lambert law-based optical absorption |
| Air Purification System | Activated carbon adsorption + silica gel drying tower + thermal constant-temperature bath |
| Gas Path Design | Parallel ozone flow relative to specimen surface |
| Control System | AI digital PID controller with SSR output |
| Timer Resolution | 0.1 s (programmable up to 9999 h 59 min 59 s) |
| Data Interface | RS232 serial port, 4–20 mA analog output |
| Optional | PC-based real-time monitoring & data logging software with print/export capability |
| Electrical Supply | 220 VAC ±10%, 50/60 Hz |
| Safety Protections | Leakage current protection, over-temperature cutoff, motor overheat detection, over-current circuit breaker |