Peristaltic Pump
Filter
Showing 31–53 of 53 results
| Brand | Kamoer |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | KMC57 |
| Instrument Type | Peristaltic Pump |
| Flow Rate Range | 0.01–29 mL/min per channel |
| Motor Type | 57-step Hybrid Stepper Motor |
| Channel Configuration | Configurable for 3- or 4-channel pump heads |
| Rotor Design | 12-roller low-pulsation rotor |
| Mounting | Front-panel flush-mount compatible |
| Tubing Compatibility | PVC, PU, and other chemically resistant elastomeric tubing (including microbore capillary tubing) |
| Application Domain | ICP-OES/ICP-MS sample introduction, analytical instrument fluid handling, microfluidic dispensing, clinical analyzer reagent delivery |
| Brand | KEWLAB |
|---|---|
| Model | CPS-L350 |
| Pump Type | Peristaltic Pump |
| Flow Rate Range | 0.007–1330 mL/min |
| Speed Range | 0.1–350 rpm (0.01 rpm resolution) |
| Display | 3.2-inch industrial-grade true-color LCD |
| Pressure Output | 0.1 MPa (for tubing wall thickness 0.86–1.0 mm) / 0.1–0.27 MPa (for tubing wall thickness 1.6–2.4 mm) |
| External Control Input | 0–5 V (standard), optional 0–10 V or 4–20 mA |
| Communication Interface | RS232 / RS485 |
| Power Supply | AC 220 V ±10% or AC 110 V ±10%, 50/60 Hz |
| Dimensions (L×W×H) | 261.4 × 157.3 × 236.9 mm |
| Power Consumption | <50 W |
| Operating Environment | 0–40 °C, <80% RH |
| Ingress Protection Rating | IP31 |
| Timer Range | 0.1 s – 9999 h |
| Memory Function | Power-loss retention of operating parameters |
| Brand | KEWLAB |
|---|---|
| Model | CPS-T150 |
| Pump Type | Peristaltic Pump |
| Flow Rate Range | 0.007–570 mL/min |
| Speed Range | 0.1–150 rpm (0.01 rpm resolution) |
| Display | 4.3-inch industrial-grade TFT color LCD |
| Pressure Rating | 0.1 MPa (for tubing wall thickness 0.86–1.0 mm) / 0.1–0.27 MPa (for tubing wall thickness 1.6–2.4 mm) |
| External Control Input | 0–5 V (standard), optional 0–10 V or 4–20 mA |
| Communication Interface | RS232 / RS485 |
| Power Supply | AC 220 V ±10% / 50–60 Hz or AC 110 V ±10% / 50–60 Hz |
| Dimensions (L×W×H) | 261.4 × 157.3 × 236.9 mm |
| Power Consumption | <50 W |
| Operating Environment | 0–40 °C, <80% RH |
| Ingress Protection | IP31 |
| Enclosure Material | UV-resistant ABS engineering plastic |
| PCB Protection | Triple-conformal coating (dust-, moisture-, static-, and corrosion-resistant) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LABA-2000 |
| Instrument Type | Syringe Pump / Dual-Channel High-Pressure Solvent Delivery Pump |
| Flow Rate Range | 0–1000 mL/min |
| Maximum Speed | 6000 rpm |
| Construction Options | Full Stainless Steel or Full PEEK Fluid Path |
| Interface | RS-232 |
| Safety Features | Real-time Pressure Monitoring with High/Low Pressure Cut-off |
| Control | Local Keypad + LED Display + Remote Command Support |
| Brand | LeadFluid |
|---|---|
| Origin | Hebei, China |
| Model | BQ80S |
| Flow Rate Range | 0.0035–34 mL/min |
| Speed Range | 0.1–80 rpm |
| Speed Resolution | 0.1 rpm |
| Speed Accuracy | < ±0.2% |
| Operating Time Range | 0.1 s to 999 days |
| Interval Time Range | 0.1 s to 999 days |
| Dispense Count | 1–999 cycles (0 = continuous) |
| External Control Inputs | Dry-contact or 5–24 V level for start/stop & direction |
| Communication Interface | RS485, Modbus RTU protocol |
| Power Supply | AC 100–240 V, 50/60 Hz (with adapter) |
| Power Consumption | <10 W |
| Noise Level | ≤60 dB(A) |
| Operating Environment | 0–40 °C, RH <80% |
| Enclosure Dimensions (DW10-1) | 152 × 112 × 107 mm |
| Enclosure Dimensions (DW10-3) | 164 × 112 × 107 mm |
| Ingress Protection | IP31 |
| Compatible Pump Heads | DW10-1 (single-channel), DW10-3 (triple-channel) |
| Tubing Compatibility | Wall thickness 0.8–1.0 mm, ID ≤3.17 mm |
| Brand | LeadFluid |
|---|---|
| Origin | Hebei, China |
| Model | BT100S |
| Flow Rate Range | 0.00011–750 mL/min |
| Speed Range | 0.1–150 rpm |
| Speed Resolution | 0.1 rpm (≤100 rpm), 1 rpm (>100 rpm) |
| Speed Accuracy | < ±0.2% |
| Operating Time Setting | 0.1 s to 999 days (adjustable unit) |
| Interval Time Setting | 0.1 s to 999 days (adjustable unit) |
| Cycle Count | 1–999 cycles (0 = continuous) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Power Consumption | < 40 W |
| Ambient Temperature | 0–40 °C |
| Relative Humidity | < 80% |
| Dimensions (L×W×H) | 261 × 150 × 237 mm |
| Enclosure Material | Stainless Steel 304 |
| Protection Rating | IP31 |
| Weight | 3.5 kg |
| Communication Interface | RS485, Modbus RTU protocol |
| External Control Inputs | Opto-isolated digital signals (5–24 V), analog inputs (0–5 V / 0–10 V / 4–20 mA) |
| External Status Outputs | Start/Stop, Forward/Reverse logic-level signals |
| Software Compatibility | LF-LCD-OS firmware with bilingual (EN/CN) UI, LeadFluid Mobile App (optional) |
| Brand | LeadFluid |
|---|---|
| Origin | Hebei, China |
| Model | BT101L |
| Pump Type | Peristaltic Pump |
| Flow Rate Range | 0.00011–750 mL/min |
| Speed Range | 0.1–150 rpm |
| Speed Resolution | 0.1 rpm |
| Speed Accuracy | < ±0.2% |
| Communication Interface | RS485 (Modbus RTU compatible) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Power Consumption | < 30 W |
| Operating Temperature | 0–40 °C |
| Relative Humidity | < 80% RH |
| Dimensions (L×W×H) | 258 × 180 × 197 mm |
| Weight | 3.6 kg |
| Ingress Protection | IP31 |
| External Control | TTL-level digital input (5 V / 12 V standard, 24 V optional), analog speed control (0–5 V standard, 0–10 V / 4–20 mA optional) |
| Enclosure Material | ABS engineering plastic |
| Isolation Design | Dual-layer circuit isolation with conformal coating |
| Brand | LeadFluid |
|---|---|
| Origin | Hebei, China |
| Model | BT103S |
| Flow Rate Range | 0.00011–500 mL/min |
| Speed Range | 0.1–100.0 rpm |
| Speed Resolution | 0.1 rpm |
| Speed Accuracy | < ±0.2% |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Power Consumption | < 30 W |
| Operating Temperature | 0–40 °C |
| Relative Humidity | < 80% RH |
| Dimensions (L×W×H) | 235 × 140 × 145 mm |
| Weight | 2.8 kg |
| Protection Rating | IP31 |
| Communication Interface | RS485, Modbus RTU protocol compliant |
| External Control | Digital I/O (5–24 V), Analog Input (0–5 V / 0–10 V / 4–20 mA configurable) |
| Optional Features | Occlusion alarm, leak detection, thermal printer interface, mobile app remote control (via LeadFluid APP) |
| Brand | LeadFluid |
|---|---|
| Origin | Hebei, China |
| Model | BT300L |
| Flow Rate Range | 0.005–1750 mL/min |
| Speed Range | 0.1–350 rpm |
| Speed Resolution | 0.1 rpm |
| Speed Accuracy | < ±0.2% |
| Operating Temperature | 0–40 °C |
| Relative Humidity | < 80% |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Power Consumption | < 50 W |
| Dimensions (L×W×H) | 292 × 160 × 183 mm |
| Weight | 4.5 kg |
| Protection Rating | IP31 |
| Communication | RS485 (Modbus RTU), DB15 external I/O interface, WiFi (via LeadFluid APP) |
| Control Inputs | Digital (5–24 V), Analog (0–5 V / 0–10 V / 4–20 mA) |
| External Signal Isolation | Galvanically isolated |
| Brand | LeadFluid |
|---|---|
| Origin | Hebei, China |
| Model | BT300S |
| Flow Rate Range | 0.005–1750 mL/min |
| Speed Range | 0.1–350 rpm |
| Speed Resolution | 0.1 rpm (≤100 rpm), 1 rpm (>100 rpm) |
| Speed Accuracy | < ±0.2% |
| Operating Time & Interval | 0.1–999 s/min/h/d (selectable unit) |
| Cycles | 1–999 (0 = continuous) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Power Consumption | <50 W |
| Dimensions (L×W×H) | 261 × 150 × 237 mm |
| Weight | 4.3 kg |
| Enclosure Material | Stainless Steel 304 |
| Ingress Protection | IP31 |
| Communication Interface | RS485 (Modbus RTU compatible) |
| External Control | Opto-isolated digital I/O, analog input (0–5 V / 0–10 V / 4–20 mA configurable) |
| Output Signals | Start/Stop, Direction status |
| Certifications | CE-marked per EN 61326-1 (EMC), EN 61010-1 (Safety) |
| Brand | LeadFluid |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BT600L |
| Instrument Type | Peristaltic Pump |
| Flow Rate Range | 0.005–3000 mL/min |
| Speed Range | 0.1–600 rpm |
| Speed Resolution | 0.1 rpm |
| Speed Accuracy | < ±0.2% |
| Operating Time Range | 0.10–99.99 s/min/h (selectable unit) |
| Interval Time Range | 0.1–999.9 s/min/h (selectable unit) |
| Cycle Count | 1–999 (0 = continuous) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Power Consumption | < 60 W |
| Ambient Operating Conditions | 0–40 °C, RH < 80% |
| Dimensions (L×W×H) | 292 × 160 × 183 mm |
| Enclosure Rating | IP31 |
| Weight | 4.5 kg |
| Delayed Start & Timed Stop | 1 s – 999 h 59 min 59 s |
| Analog Output | 0–5 V (speed status) |
| Digital Interface | RS485, Modbus RTU compliant |
| External Control Input | Start/Stop, Direction (5–24 V logic), Analog 0–5 V / 0–10 V / 4–20 mA configurable |
| Isolated I/O | Yes |
| PCB Protection | Conformal coating (3-layer spray) |
| Thermal Management | Adaptive fan control |
| Housing Material | Stainless steel (304) |
| Brand | LeadFluid |
|---|---|
| Origin | Hebei, China |
| Model | BT600S |
| Pump Type | Peristaltic Pump |
| Flow Rate Range | 0.005–3000 mL/min |
| Speed Range | 0.1–600 rpm |
| Speed Resolution | 0.1 rpm (≤100 rpm), 1 rpm (>100 rpm) |
| Speed Accuracy | < ±0.2% |
| Operating Time & Interval Range | 0.1–999 s/min/h/d (unit-selectable) |
| Cycle Count | 1–999 (0 = continuous) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Power Consumption | <60 W |
| Dimensions (L×W×H) | 261 × 150 × 237 mm |
| Weight | 4.3 kg |
| Enclosure Material | Stainless Steel 304 |
| Protection Rating | IP31 |
| Communication Interface | RS485 (Modbus RTU compatible) |
| External Control | Digital I/O (opto-isolated), Analog Input (0–5 V / 0–10 V / 4–20 mA configurable) |
| Output Signals | Run/Stop, Direction status |
| Operating Environment | 0–40 °C, RH <80% |
| Brand | Masterflex |
|---|---|
| Origin | USA |
| Model | Masterflex Easy-Load II Peristaltic Pump (L/S® MasterSense Drive) |
| Max Speed | 600 rpm |
| Max Flow Rate | 3400 mL/min |
| Motor Type | Brushless DC, Maintenance-Free |
| Speed Accuracy | ±0.1% |
| Gear Reduction Ratio | 6000:1 |
| Connectivity | EtherNet/IP, Profibus, Wi-Fi, Analog Remote I/O |
| Display | Touchscreen with Glove-Compatible Interface |
| Tube Compatibility | All L/S®-series pump heads |
| Calibration Aid | Graphical LED alignment indicator |
| Safety Features | Drip-proof design, pump-head open sensor, power-status LED |
| Firmware | Over-the-air (OTA) updates via MasterflexLive™ |
| Brand | Masterflex |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MasterSense™ Process Pump (L/S® Platform) |
| Instrument Type | Peristaltic Pump |
| Enclosure Rating | IP66 / NEMA 4X |
| Display | 5-inch capacitive TFT/RGB touchscreen (12.7 cm), wide viewing angle |
| Control Modes | Continuous Run, Volume Dispense, Time-Based Dispense |
| User Access Levels | Three-tiered authentication (Operator, Supervisor, Administrator) |
| Connectivity | MasterflexLive™ cloud platform, EtherNet/IP™, PROFIBUS, 0–10 V / 4–20 mA analog I/O |
| Pressure Monitoring | Integrated real-time pressure sensing with configurable alarms |
| Fluid Handling | Drip-free dispensing, programmable acceleration/deceleration ramps |
| Construction | 316 stainless steel housing |
| Firmware | Over-the-air (OTA) wireless updates |
| Compliance | Designed for GLP/GMP environments |
| Brand | Masterflex |
|---|---|
| Origin | USA |
| Motor Type | 1/3-hp Brushless DC Motor |
| Enclosure Rating | IP55 |
| Construction | Epoxy-Coated Steel Housing |
| Flow Range | 0.2–26 L/min (0.06–6.9 GPM) |
| Speed Control | 3-Position Potentiometer (5–100% of max RPM) |
| Display | Digital LED Speed Indicator |
| Pump Head Compatibility | Dual I/P Easy-Load® Pump Heads |
| Weight | Lightweight, Single-Hand Portable |
| Regulatory Compliance | CE-marked, RoHS-compliant, Designed for GLP/GMP Environments |
| Brand | Masterflex |
|---|---|
| Origin | USA |
| Model | Reglo Digital Miniflex |
| Pump Type | Peristaltic Pump |
| Display | 5" Capacitive TFT/RGB Touchscreen (12.7 cm) |
| Operating Modes | Continuous, Volume Mode, Timed Dispensing |
| Programmable Features | User-Saved Protocols, Drip Prevention, Speed Adjustment in Volume Mode |
| Pump Head | Miniflex 2-Channel 12-Roller Head with Continuous Tubing Path |
| User Access Levels | Three-Tier Permission System |
| Compliance | Designed for GLP/GMP environments with audit-ready operation logging capability |
| Brand | Masterflex |
|---|---|
| Origin | USA |
| Model | Reglo Digital Miniflex |
| Pump Type | Peristaltic Pump |
| Channel Count | 4 |
| Roller Count per Head | 6 |
| Display | 5" Capacitive TFT/RGB Touchscreen (12.7 cm) |
| Operating Modes | Continuous, Volume Dispensing, Timed Dispensing |
| Pump Head Compatibility | Miniflex Standard Tubing Cartridge System |
| User Access Levels | Three-Tier Authentication |
| Brand | Masterflex |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Masterflex L/S® Digital Drive System |
| Instrument Type | Peristaltic Pump |
| Enclosure Rating | NEMA 4X / IP66 |
| Flow Range (with L/S tubing) | 0.006–3400 mL/min (max 54 GPH) |
| Motor | Brushless, Maintenance-Free |
| Speed Accuracy | ±0.1% |
| Turndown Ratio | 6000:1 |
| Display | Graphical LCD |
| Operation Modes | Continuous, Timed Dispense, Repeat Dispense, Volume Dispense |
| Volume Units | mL (0.001–99999), L, gal |
| Repeat Count | 1–9999 |
| Time Interval per Cycle | 1 s–99 h 59 min 59 s |
| Drip Prevention | Yes |
| Interface Languages | 7 selectable |
| Analog I/O | 0–20 mA / 4–20 mA / 0–10 V (speed control & tachometer), Open-collector or dry-contact (direction, start/stop/clean) |
| Brand | Masterflex |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Masterflex L/S® PTFE Diaphragm Pump |
| Instrument Type | Peristaltic Pump |
| Flow Rate | 80–800 mL/min |
| Maximum Pressure | 50 psi (3.4 bar) |
| Wetted Materials | PTFE |
| Check Valve Function | Maintains prime for up to 2 hours after shutdown |
| Fluid Path Geometry | Optimized to minimize turbulence and dead volume |
| Brand | Signal |
|---|---|
| Origin | Hebei, China |
| Model | iPump2L / iPump4L / iPump6L |
| Flow Rate Range | 0.0006–2416 mL/min |
| Speed Range | 0.01–600 RPM |
| Accuracy | ±0.5% |
| Display | 128×32 Graphic LCD |
| Control Interface | Rotary Encoder + Membrane Keypad |
| External Control Options | 0–5 V, 0–10 V, 4–20 mA, 0–10 kHz (optical isolation) |
| Communication | RS485 with Modbus RTU protocol (optional) |
| Protection Rating | IP31 |
| Power Supply | AC 90–260 V, 50/60 Hz |
| Operating Environment | 0–40 °C, <80% RH non-condensing |
| Dimensions (L×W×H) | 291 × 208 × 180 mm (driver only) |
| Weight | 3.8 kg (iPump2L), 50 W max |
| Brand | Signal |
|---|---|
| Origin | Hebei, China |
| Model | iPump2S-D |
| Flow Rate Range | 0.006–1970 mL/min |
| Speed Range | 0.1–200 rpm |
| Speed Resolution | 0.1 rpm (<100 rpm), 1 rpm (≥100 rpm) |
| Display | 3-digit LED for speed and timer |
| Direction Control | Bidirectional |
| Timing Function | 0.1 s–99 h |
| External Control Options | 0–5 V, 0–10 V, 4–20 mA, 0–10 kHz (optical isolation) |
| Communication | RS485 with Modbus RTU protocol (optional) |
| Protection Rating | IP31 |
| Power Supply | AC 90–260 V, 50/60 Hz |
| Power Consumption | <50 W |
| Operating Environment | 0–40 °C, ≤80% RH non-condensing |
| Dimensions (L×W×H) | 224 × 147 × 227 mm (excl. pump head) |
| Weight | 3.8 kg |
| Enclosure Material | 304 stainless steel |
| PCB | Conformal coated (triple protection against moisture, corrosion, and dust) |
| Brand | Signal |
|---|---|
| Origin | Hebei, China |
| Model | iPump4S / iPump6S |
| Flow Rate Range | 0.008–2416 mL/min |
| Speed Range | 0.1–200 RPM (iPump4S), 0.1–600 RPM (iPump6S) |
| Speed Resolution | 0.1 RPM (<100 RPM), 1 RPM (≥100 RPM) |
| Power Consumption | 50 W (iPump4S), 75 W (iPump6S) |
| Input Voltage | AC 90–260 V, 50/60 Hz |
| Operating Environment | 0–40 °C, <80% RH non-condensing |
| Dimensions (L×W×H) | 291 × 208 × 180 mm (excl. pump head) |
| Weight | 3.6 kg |
| IP Rating | IP31 |
| External Control Options | 0–5 V, 0–10 V, 4–20 mA, 0–10 kHz (optical isolation) |
| Communication | RS485 with Modbus RTU protocol (optional module) |
| Footswitch Support | Yes (optional) |
| Display | 3-digit LED, showing speed and timer |
| Direction Control | Bidirectional |
| Timer Range | 0.1 s – 99 h |
| Memory Function | Power-loss retention of operational state |
| Brand | Signal |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | iPump6S-G + YZ35B |
| Pump Type | Peristaltic Pump |
| Flow Rate Range | 0.46–12 L/min |
| Speed Range | 40–600 RPM |
| Resolution | 1 RPM |
| Power Consumption | <300 W |
| Input Voltage | AC 180–260 V, 50 Hz |
| Operating Environment | 0–40 °C, RH <80% non-condensing |
| Enclosure Rating | IP31 |
| Dimensions (L×W×H) | 370 × 235 × 240 mm (excluding pump head) |
| Weight | 11.5 kg |
| Housing Material | 304 Stainless Steel |
| PCB Protection | Triple-Conformal Coated |
| Control Modes | Speed, Flow, Timer |
| Direction | Reversible |
| Timer Range | 1 s – 99 h |
| External Control Options | 0–5 V, 0–10 V, 4–20 mA, 0–10 kHz (optical isolation) |
| Communication | RS485 Modbus RTU (optional module) |
| Footswitch Support | Optional |
| Full-Speed Fill/Empty Function | Yes |
| Power-Fail Memory | Yes |
| Display | 4-digit LED (speed or flow, toggleable) |