| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Avio 500 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Argon Consumption | <10 L/min (typical operational mode) |
| Plasma Orientation | Dual-View (Axial & Radial) |
| Plasma Technology | Flat Plasma™ |
| Background Correction | Real-Time Synchronous Background Correction |
| Detection Capability | Multi-element, simultaneous quantitative analysis of metals and some non-metals in liquid samples |
| Software Platform | Syngistix™ for ICP-OES |
| Brand | PerkinElmer |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | PinAAcle™ 950D |
| Pricing | Available upon request |
| Brand | PerkinElmer |
|---|---|
| Manufacturer Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Imported |
| Model | TG-hiden MS |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | LAMBDA 750 |
| Instrument Architecture | Double-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Scanning | Motorized Automatic |
| Wavelength Range | 175 nm to 3300 nm |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Avio 200 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Gas Consumption | <8 L/min Ar (typical operational mode) |
| Startup Time | <5 minutes from cold start to analysis-ready |
| Dual-View Capability | Axial and Radial Simultaneous Observation without Sensitivity Loss |
| Linear Dynamic Range | Up to 9 orders of magnitude |
| Detector | Back-Illuminated CCD with On-Chip Background Correction |
| Plasma Technology | Flat Plate™ RF Generator and PlasmaShear™ Air-Based Tail Flame Elimination |
| Torch Orientation | Vertical, Tool-Free Adjustable Base with Interchangeable Injector Tubes |
| Software Platform | Syngistix for ICP-OES (21 CFR Part 11 Compliant) |
| Brand | PerkinElmer |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | NexION 100G |
| Pricing | Available upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Spotlight 400/400N |
| Instrument Type | Laboratory FT-IR Imaging System |
| Detector Architecture | Patented Linear Array MCT Detector |
| Spectral Range | Up to 720 cm⁻¹ (Mid-IR) and Extended NIR Capability |
| Spatial Resolution | 1.56 µm (ATR mode), 6.25 µm / 25 µm / 50 µm (Transmission/Reflection modes) |
| Imaging Speed | Up to 170 spectra/sec |
| Scan Modes | Single-region, Multi-region, Unattended Overnight Acquisition |
| Sample Stage | Motorized, High-Precision, Repeatability ±0.001% |
| Optional Accessories | Imaging ATR, Large-Area Sample Stage |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer | PerkinElmer, Inc. |
| Instrument Type | Imported |
| Model | LAMBDA 465 |
| Optical Design | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.2 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | <0.03% T at 340 nm |
| Automation | Motorized Wavelength Scanning |
| Light Sources | Deuterium Lamp + Tungsten-Halogen Lamp |
| Regulatory Compliance | FDA 21 CFR Part 11–enabled Software |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | QSight |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Application Domain | General-Purpose Quantitative Analysis |
| Ionization Sources | Dual ESI/APCI Configurable |
| Polarity Switching Speed | Microsecond-Level |
| Detection Principle | Electrospray Ionization (ESI) / Atmospheric Pressure Chemical Ionization (APCI) Coupled with Triple Quadrupole Mass Filtering and Collision-Induced Dissociation (CID) |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer | PerkinElmer |
| Import Status | Imported |
| Model | NexION 1000G |
| Instrument Type | Quadrupole ICP-MS |
| Interface Configuration | Triple-cone interface with UltraConic™ design |
| RF Generator | Self-excited solid-state generator with LumiCoil™ technology |
| Ion Optics Architecture | Three-quadrupole tandem mass spectrometry platform (quadrupole ion deflector, quadrupole universal cell, quadrupole mass analyzer) |
| Application Scope | Environmental, geological, food & pharmaceutical, industrial QA/QC, speciation analysis |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | LC 300 |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) / High-Performance Liquid Chromatograph (HPLC) |
| Pressure Rating Options | 10,000 psi (HPLC mode) or 18,000 psi (UHPLC mode) |
| Detector Options | PDA, Multi-Channel UV/Vis, Single-Channel UV/Vis, Fluorescence, Refractive Index |
| Software Platform | Simplicity™ Chrom CDS |
| Gradient Accuracy | <0.2% RSD |
| System Dispersion Volume | <12 µL (typical, full system configuration) |
| Autosampler Features | Integrated color touchscreen display, programmable sample cooling (4–40 °C), low carryover (<0.005%) |
| Column Oven Temperature Range | 5–90 °C |
| Compliance | Designed for GLP/GMP environments |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | NexION 5000 |
| Instrument Type | Quadrupole-based ICP-MS |
| Application Environment | Laboratory |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | STA 8000 |
| Pricing | Upon Request |
| Temperature Range | −150 °C to 1600 °C |
| Heating Rate | 0.01–100 °C/min |
| Temperature Stability | ±0.01 °C (at isothermal hold) |
| Maximum Sample Mass | 2 g (standard), up to 5 g (optional crucible) |
| Atmosphere Control | Dual-gas MFC with programmable switching (N₂, O₂, Ar, He, air, forming gas) |
| Balance Resolution | 0.1 µg |
| DSC Sensitivity | < 0.1 µW |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer | PerkinElmer |
| Import Status | Imported |
| Model | LPC 500 |
| Pricing | Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Clarus 680 GC |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | TG-MS |
| Pricing | Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | MPS 320™ |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Imported |
| Model | Lambda 950 |
| Optical Design | Double-Beam, Dual-Monochromator |
| Detector | R6872 Photomultiplier Tube (PMT) |
| Wavelength Range | 175–3300 nm (185 nm minimum under nitrogen purge) |
| Spectral Bandwidth | Variable (0.01–8 nm), software-selectable |
| Wavelength Accuracy | ±0.08 nm (UV/Vis), ±0.2 nm (NIR) |
| Stray Light | <0.00008% T at 220 nm (NaI), <0.0001% T at 340 nm (NaNO₂) |
| Photometric Linearity | Up to 8.0 A (absorbance) |
| Baseline Flatness | ±0.0004 A (190–3300 nm, 1 nm SBW) |
| Automation | Fully motorized optics, auto-lamp switching (D₂ & W/Tungsten), auto-correcting chopper, PC-controlled |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | STA6000 |
| Pricing | Upon Request |
| Heating Rate (°C/min) | Up to 100 |
| Temperature Range (°C) | −150 to 1500 |
| Temperature Stability | ±0.01 °C |
| Maximum Sample Weight (g) | 2000 |
| Atmosphere Control | Dual-gas MFC with Auto-Switching (Inert, Oxidizing, Reducing) |
| Brand | PerkinElmer |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | LAMBDA 1050+ |
| Optical Design | Double-beam |
| Detector Type | Photomultiplier Tube (PMT) for UV-Vis |
| Wavelength Range | 175–3300 nm |
| Wavelength Accuracy | ±0.025 nm (UV-Vis), ±0.02 nm (NIR) |
| Automation | Motorized wavelength scanning and accessory control |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | DSC 4000 / DSC 6000 |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –100 °C to 600 °C (with optional cryogenic and high-temp accessories) |
| Temperature Accuracy | ±0.1 °C (traceable to NIST standards) |
| Heating/Cooling Rate | 0.1–100 K/min (programmable in 0.1 K/min increments) |
| Brand | PerkinElmer |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | FL 6500 |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth (Slit Width) | 1, 2.5, 5, 10, 20 nm |
| Resolution | 1.0, 2.5, 5, 10, 20 nm |
| Sensitivity | >750:1 (RMS) |
| Dispersion Element | Grating |
| Light Source | Pulsed Xenon Lamp |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | PinAAcle D900 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp Correction |
| Safety Interlocks | 7 Integrated Sensors |
| Automation | Dual-Mode Autosampler Compatible with Both Flame and GF Modes |
| Software Interface | Touchscreen-Controlled Method Wizard with Real-Time Camera Integration |
| Reporting | Customizable PDF Reports Including Calibration Curves and Sample Data |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Instrument |
| Model | LPC500 + Avio500 |
| Application | Elemental Analysis & Particle Counting in Lubricants |
| Sample Volume | <1 mL per dual analysis |
| Cycle Time | ≤45 seconds per sample |