| Brand | PerkinElmer |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | LAMBDA 750 |
| Instrument Architecture | Double-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Scanning | Motorized Automatic |
| Wavelength Range | 175 nm to 3300 nm |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer | PerkinElmer, Inc. |
| Instrument Type | Imported |
| Model | LAMBDA 465 |
| Optical Design | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.2 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | <0.03% T at 340 nm |
| Automation | Motorized Wavelength Scanning |
| Light Sources | Deuterium Lamp + Tungsten-Halogen Lamp |
| Regulatory Compliance | FDA 21 CFR Part 11–enabled Software |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Imported |
| Model | Lambda 950 |
| Optical Design | Double-Beam, Dual-Monochromator |
| Detector | R6872 Photomultiplier Tube (PMT) |
| Wavelength Range | 175–3300 nm (185 nm minimum under nitrogen purge) |
| Spectral Bandwidth | Variable (0.01–8 nm), software-selectable |
| Wavelength Accuracy | ±0.08 nm (UV/Vis), ±0.2 nm (NIR) |
| Stray Light | <0.00008% T at 220 nm (NaI), <0.0001% T at 340 nm (NaNO₂) |
| Photometric Linearity | Up to 8.0 A (absorbance) |
| Baseline Flatness | ±0.0004 A (190–3300 nm, 1 nm SBW) |
| Automation | Fully motorized optics, auto-lamp switching (D₂ & W/Tungsten), auto-correcting chopper, PC-controlled |
| Brand | PerkinElmer |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | LAMBDA 1050+ |
| Optical Design | Double-beam |
| Detector Type | Photomultiplier Tube (PMT) for UV-Vis |
| Wavelength Range | 175–3300 nm |
| Wavelength Accuracy | ±0.025 nm (UV-Vis), ±0.02 nm (NIR) |
| Automation | Motorized wavelength scanning and accessory control |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | LAMBDA 365 |
| Instrument Configuration | Dual-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Automatic |
| Spectral Bandwidth | Selectable (0.5, 1, 2, 5, or 20 nm) |
| Wavelength Accuracy | ±0.1 nm |
| Stray Light | <0.02% T at 340 nm |
| Brand | PerkinElmer |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Configuration | Double-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Spectral Bandwidth | 0.5 nm to 20 nm |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ±0.02 nm |
| Stray Light | <0.00004% T at 220 nm and 340 nm |
| Absorbance Range | Up to 4.0 A |
| Automation Level | Fully Automated Wavelength Scanning & Parameter Control |
| Compliance | ASTM E275, ISO 9001, USP <857>, FDA 21 CFR Part 11 Ready |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | LAMBDA 265 |
| Instrument Architecture | Single-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±1 nm |
| Stray Light | <0.03% T at 340 nm |
| Brand | PerkinElmer |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | LAMBDA 850+ |
| Instrument Architecture | Double-Beam |
| Detector Type | R6872 Photomultiplier Tube (PMT) |
| Automation Level | Motorized Wavelength Scanning |
| Wavelength Range | 175–900 nm |
| Wavelength Accuracy | ±0.025 nm |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Lambda 650 / Lambda 850 / Lambda 950 |
| Optical Design | Double-Beam, Dual-Monochromator |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Scanning | Motorized & Auto-Calibrated |
| Wavelength Range | 175 nm to 3300 nm (model-dependent: Lambda 650: 190–900 nm |
| Lambda 850 | 175–900 nm |
| Lambda 950 | 175–3300 nm) |
| Linear Dynamic Range | Up to 8 A (Lambda 850/950), 6 A (Lambda 650) |
| Wavelength Accuracy | ±0.08 nm (UV-Vis region) |
| Stray Light | < 0.00008% T at 220 nm (typical) |
| Beam Geometry | Ratio-recording, chopper-synchronized dual-beam |