| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Internal Dimensions (W×D×H) | 1000 × 1000 × 1000 mm |
| External Dimensions (W×D×H) | 1850 × 1350 × 1550 mm |
| UV-A Spectral Range | 320–380 nm |
| Irradiance Control Range | 0.7 W/m² @ 340 nm (adjustable) |
| Humidity Range (Irradiation Mode) | 45–80% RH |
| Condensation Humidity | ≥95% RH |
| Condensation Temperature Range | 40–60°C (±3°C tolerance) |
| Light Exposure Temperature Range | 50–60°C (±3°C tolerance) |
| Black Panel Temperature Range | 30–60°C (±1°C tolerance) |
| Temperature Resolution | 0.1°C |
| Water Tray Depth | ≤30 mm with Auto-Water Supply Control |
| Irradiance Measurement | Fixed-position UV radiometer with high-accuracy digital display |
| Cycle Programming | Independent and combined irradiation/condensation cycles, programmable up to 999 hours per segment |
| Electrical Components | Schneider (France) control modules |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Radiation Intensity | ≤50 W/m² (per GB/T 19394–2003, Clause 5) |
| Temperature Range | 40–70 °C |
| Temperature Uniformity | ±2 °C |
| Temperature Fluctuation | ±0.5 °C |
| Chamber Dimensions (W×D×H) | 1000 × 1000 × 1000 mm |
| Xenon Lamp Quantity | 4 pcs |
| Lamp Power | 40 W each |
| Black Panel Thermometer | Aluminum substrate |
| Sample Mounting Options | Rotating turntable or stainless steel shelf (user-selectable) |
| UV Spectral Options | UV-A (295–360 nm) or UV-B (280–315 nm) |
| Control System | TEMI-880 16-bit true-color touchscreen, 100 programmable profiles × 100 segments/profile, PID temperature regulation with overshoot suppression |
| Communication Interface | RS-485 for remote PC-based monitoring and control |
| Spray Nozzle | 1 unit |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | −70 °C to +100 °C |
| Humidity Range | 10–98% RH |
| Humidity Uniformity | ±3% RH |
| Temperature Uniformity | ±2 °C |
| Rainfall Duration | 0–9999 min (continuous) |
| Rainfall Cycle | 0–240 min (intermittent) |
| Xenon Lamp Power | 6 kW ±5% |
| Spectral Range | 290–400 nm |
| Irradiance Control | 0.35–0.65 W/m²/nm @ 340 nm |
| Sample Rack Rotation | 1 rpm, 360° |
| Lamp-to-Sample Distance | 300–375 mm |
| Refrigerant | R404A |
| Cooling System | Air-cooled, hermetic French Tecumseh compressor |
| Humidity Control | Direct steam injection + dew-point contact dehumidification |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, SAE J2412, GB/T 16422.2, GB/T 1865, IEC 60068-2-5 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Chamber Dimensions (W×H×D) | 500 × 700 × 600 mm |
| External Dimensions | Custom-Fit Enclosure |
| Total Power Consumption | 9 kW |
| Lamp Configuration | Single Air-Cooled 1.8 kW Xenon Arc Lamp |
| Spectral Range | 290–800 nm |
| Irradiance (290–800 nm) | 550 W/m² |
| Black Panel Temperature Range | 63 °C / 100 °C (selectable) |
| Temperature Range | RT to +80 °C |
| Temp. Uniformity | ±2.0 °C |
| Temp. Stability | ±0.5 °C |
| Humidity Range | 45–90 %RH |
| Humidity Control Accuracy | ≤ ±2 %RH |
| Water Spray Nozzle Diameter | Ø0.8 mm |
| Spray Duration | 0–9999 min (continuous) |
| Spray Cycle Interval | 0–240 min (intermittent) |
| Sample Rack Distance from Lamp | 230–280 mm |
| Heating Power | 3 kW |
| Humidification Power | 1.5 kW |
| Filter | Single Borosilicate Glass Daylight Filter |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,300 (Reference Only) |
| Chamber Models | OK-XD-100 / OK-XD-225 / OK-XD-500 / OK-XD-1000 |
| Internal Dimensions (W×D×H, cm) | 50×50×40 / 50×75×60 / 80×80×80 / 100×100×100 |
| Temperature Range | 0–150°C (Chamber), 40–85°C (Black Panel) |
| Humidity Range | 20–75% RH (Light Cycle), 20–98% RH (Dark Cycle) |
| Control Accuracy | ±0.5°C / ±2.0% RH |
| Uniformity | ±2.0°C / ±3.0% RH |
| Spectral Range | 300–800 nm (550 W/m² ±10%), 300–1200 nm (1000 W/m² ±10%) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ~1500 h |
| Spray Duration | 1–999 min (Intermittent or Continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Holder | Dual-layer mesh tray or 500 mm diameter rotating turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 5,300 (approx.) |
| Brand | Xepics |
|---|---|
| Origin | Italy |
| Model | HVB |
| Voltage Range | Up to 30 kV |
| Liquid Conductivity Detection Limit | ≥1 µS/cm |
| Sample Throughput | 120 containers/min |
| Compatible Containers | Vials, Ampoules, Prefilled Syringes, IV Bags, Blow-Fill-Seal (BFS) & Form-Fill-Seal (FFS) containers |
| Dimensions (W×D×H) | 190 × 85 × 127 cm |
| Power Supply | 110–240 VAC, 50–60 Hz, 2 kW |
| Control System | Windows 10 PC with 8" Touchscreen Interface |
| Communication | Ethernet |
| Compliance | Designed to support USP <1207>, ISO 11607-2, ASTM F2338, and FDA 21 CFR Part 11 data integrity requirements |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | TC3200L |
| Measurement Principle | Transient Hot Wire (THW) Method |
| Temperature Range | Ambient to 200 °C |
| Pressure Range | 0.1–15 MPa (optional pressure control) |
| Thermal Conductivity Range | 0.0005–5 W/(m·K) |
| Resolution | 0.0001 W/(m·K) |
| Accuracy | ±3% |
| Repeatability | ±3% |
| Sample Volume Requirement | ≥40 mL |
| Measurement Time | ≤2 s |
| Sample Forms | Liquids and gases |
| Test Atmospheres | Vacuum, air, inert gas |
| Dimensions (L×W×H) | 550×500×650 mm |
| Compliance Standards | ASTM D2717, ASTM D7896 |
| Data Interface | USB |
| Operating System | Windows |
| Brand | Xiatech |
|---|---|
| Model | TC3300 |
| Measurement Principle | Transient Hot Wire Method |
| Temperature Range | –150 °C to Ambient |
| Thermal Conductivity Accuracy | ±5% |
| Repeatability | ±3% |
| Sample Forms | Solid, Paste, Powder, Liquid |
| Sample Dimensions | ≥25 mm (solid edge length) |
| Test Atmosphere | Air |
| Compliance | ASTM C1113, ASTM D5930, GB/T 10297, GB/T 11205 |
| Maximum Operating Pressure | High-Pressure Compatible |
| Sample Throughput | Single-sample per cycle |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | VM4300 |
| Viscosity Range | ≤200 µPa·s |
| Temperature Range | 14–300 K |
| Pressure Range | 0.1–4 MPa |
| Accuracy | ±3% |
| Measurement Principle | Vibrating Wire Method |
| Interface | USB |
| Operating System | Windows |
| Power Supply | 220 V, 50 Hz |
| [Working Chamber | 400 × 1100 × 400 mm (D×W×H) |
|---|---|
| External Dimensions | 850 × 1330 × 1000 mm (D×W×H) |
| UV-A Spectral Range | 320–380 nm |
| Irradiance Control | Adjustable up to 0.7 W/m² @ 340 nm |
| Humidity Range (Irradiation Phase) | 45–80 %RH |
| Condensation Humidity | ≥95 %RH |
| Condensation Temperature | 40–60 °C (±3 °C tolerance) |
| Light Exposure Temperature | 50–60 °C (±3 °C tolerance) |
| Black Panel Temperature Range | 30–60 °C (±1 °C tolerance) |
| Temperature Resolution | 0.1 °C |
| Water Tray Depth | ≤30 mm with Auto-Fill Control |
| Control Logic | Independent & Cyclic Programmable Irradiation/Condensation Phases (up to 999 h per segment)] |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Irradiance | ≤50 W/m² (per GB/T 19394–2003, Clause 5) |
| Chamber Dimensions (W×D×H) | 1000 × 1000 × 1000 mm |
| Temperature Range | 40–70 °C |
| Temperature Uniformity | ±2 °C |
| Temperature Stability | ±0.5 °C |
| Xenon Lamps | 4 pcs × 40 W |
| Spray Nozzle | 1 unit |
| Black Panel Thermometer | Aluminum substrate |
| Sample Mounting | Rotating turntable or stainless-steel static rack (user-selectable) |
| UV Filter Options | UV-A (295–360 nm) or UV-B (280–315 nm) |
| Brand | Xuxin Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ST-1510 |
| Measurement Range | 2–200 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.1 mN/m |
| Temperature Display Range | 0–40 °C |
| Temperature Display Precision | ±0.1 °C |
| Measurement Method | Du Noüy Ring Method |
| Repeatability | ≤0.2% RSD |
| Power Consumption | ≤20 W |
| Operating Environment | 5–45 °C, 10–80% RH |
| Power Supply | 220 V ±10%, 50 Hz |
| Dimensions | 270 × 185 × 360 mm |
| Weight | 7.5 kg |
| Compliance Standard | GB/T 6541 (Petroleum Products — Determination of Interfacial Tension Between Oil and Water — Du Noüy Ring Method) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | -20 °C to 130 °C |
| Humidity Range | 40–98% RH |
| Temperature Uniformity | ±2 °C (unloaded) |
| Temperature Fluctuation | ±0.5 °C (unloaded) |
| Humidity Fluctuation | ±2% RH |
| Chamber Models | OK-ZTH-408 (60×85×80 cm), OK-ZTH-800 (100×100×80 cm), OK-ZTH-1000 (100×100×100 cm) |
| Refrigeration | French Tecumseh hermetic compressor |
| Dryer Filter | USA Parker Hannifin (AEGO) |
| Oil Separator | China Guanya |
| Solenoid Valve | Italy Castel |
| Vibration Exciter | Japan ThreeBand coil bonding adhesive, IMV temperature sensors, Tohbu stainless mesh diaphragm |
| Power Amplifier | Siemens switches/contactors, Sanyo power modules, Motorola output devices, Fuji protective fuses |
| Cabinet Construction | A3 steel exterior with powder coating, SUS304 stainless steel interior, ultra-fine glass wool insulation |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,000 (FOB) |
| Compliance | GB/T 2423.5, GJB 150.18–1986 |
| Drive Type | Pneumatic + Electromagnetic Hybrid |
| Max Payload Capacity | Up to 2× Rated Load (Model-Dependent) |
| Platform Material | Monolithic Cast Aluminum Alloy |
| Guidance System | Chrome-Plated Precision Linear Rails |
| Impact Repeatability | ±0.5 mm (via Photoelectric Height Sensing) |
| Built-in Damping Base | High-Mass Isolation Substructure |
| Operating Mode | Sweep, Fixed-Frequency, Shock Pulse, Random Vibration (with Optional Controller) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 21,500 (approx.) |
| Model | OK-ES-10 |
| Max. Load Capacity | 70 kg |
| Effective Table Size | 1.2 m × 1.1 m |
| Stroke (Peak-to-Peak Amplitude) | 25.4 mm |
| Speed Range | 60–300 rpm |
| Speed Resolution | ±1 rpm |
| Drive Motor | 1 HP DC Motor with Smooth Start |
| Transmission | Synchronous Silent Belt |
| Control Mode | DC Speed Regulation |
| Timer Range | 0 s – 99 h |
| Power Supply | 220 V, 50 Hz |
| Net Weight | 230 kg |
| Base Construction | Heavy-Duty C-Channel Steel Frame with Anti-Vibration Rubber Mounts |
| Table Surface | Stainless Steel |
| Sample Fixation | Aluminum Fixture with Manual Knob Adjustment |
| Compliance Standards | ASTM D999, ISO 2247, EN 71-1, ISTA 3A/3E |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Frequency Range | 1–5000 Hz |
| Max Acceleration | <20 g |
| Max Displacement (p-p) | ≤5 mm |
| Load Capacity | 100 kg |
| Vibration Waveform | Sine (Half/Full Cycle) |
| Axes | Vertical + Horizontal (X/Y/Z orthogonal) |
| Control Modes | Fixed Frequency, Sweep, Programmable (15-segment), Logarithmic, Octave |
| Display Resolution | 0.01 Hz (frequency), ±0.1 Hz accuracy |
| Operating Temperature | 5–40 °C (24-hr avg ≤25 °C) |
| Humidity | ≤85% RH |
| Power Supply | AC 220 V ±10% / 50 Hz or AC 380 V ±10% / 50 Hz |
| Brand | YAMATO |
|---|---|
| Origin | Japan |
| Model | DKN313C |
| Instrument Type | Benchtop |
| Temperature Range | Ambient +10°C to 260°C |
| Temperature Uniformity | ±1.0°C (at setpoint) |
| Temperature Fluctuation | ±0.5°C |
| Heating Rate | ~60 min (from ambient to 210°C) |
| Chamber Volume | 27 L |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 14,000 (Reference Only) |
| Temperature Range | −70 °C to +150 °C |
| Humidity Range | 20–98% RH (optional: 5–98% RH) |
| Rapid TC Range | −45 °C to +85 °C or −20 °C to +85 °C |
| Ramp Rates | 5–25 °C/min (customizable) |
| Temperature Uniformity | ±2 °C |
| Temperature Stability | ±0.5 °C |
| Humidity Uniformity | ±3.0% RH (at ≥75% RH) |
| Humidity Stability | ±2.5% RH |
| Interior Material | SUS#304 Stainless Steel |
| Refrigeration System | Hermetic Dual-Stage Compressor with Eco-Friendly Refrigerants (R404A/R23) |
| Controller | Touchscreen LCD with English/Chinese Interface |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-Phase 5-Wire |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CST-50 |
| Projection Screen Size | 200 × 200 mm (graduated scale etched on optical glass) |
| Stage Dimensions | Square stage 110 × 125 mm |
| Stage Travel | Longitudinal ±10 mm, Transverse ±10 mm, Vertical ±12 mm |
| Stage Rotation | 0–360° continuous |
| Total Optical Magnification | 50× (Objective: 2.5×, Projection Lens: 20×) |
| Illumination Source | 12 V / 100 W halogen tungsten lamp |
| Power Supply | 220 V AC, 50 Hz |
| Overall Dimensions | 515 × 224 × 603 mm |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.185 |
| Max. Load | 50 N (dead-weight type) |
| Temperature Range | Up to 200 °C |
| Parallel Plate Diameter | φ40 mm (optional: UL-compliant φ3/4″ or φ3/8″) |
| Thickness Displacement Measurement | Analog dial indicator (0.01 mm resolution, 10 mm max travel) |
| Specimen Support Configurations | 1-, 3-, or 5-station modular frame |
| Included Accessory | Radius R5 mm metal mandrel |
| Power Supply | AC 200 V, single-phase, 15–30 A, 50/60 Hz |
| Dimensions & Weight | 1-station: ~780 × 825 × 1800 mm (W×D×H), ~142 kg |
| 3-station | ~1250 × 1120 × 1800 mm, ~286 kg (benchtop height option: H = 952 mm) |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | SGW® X-4 |
| Temperature Range | Ambient to 330 °C |
| Heating Methods | Capillary Method & Hot Stage Method |
| Temperature Repeatability | ±1 °C at ≤200 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Optical System | Monocular Microscope, 40× Magnification |
| Power Supply | 220 V ±22 V, 50 Hz ±1 Hz |
| Dimensions | 215 × 140 × 395 mm |
| Net Weight | 3.5 kg |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | SGW® X-4A |
| Temperature Range | Ambient to 330 °C |
| Temperature Repeatability | ±1 °C at ≤200 °C, ±2 °C at >200 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Viewing System | Monocular Microscope, 40× Magnification |
| Power Supply | 220 V ±22 V, 50 Hz ±1 Hz |
| Dimensions | 215 × 140 × 395 mm |
| Net Weight | 3.6 kg |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | SGW® X-4B |
| Temperature Range | Ambient to 330 °C |
| Temperature Repeatability | ±1 °C at ≤200 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Observation Method | Binocular Stereo Microscope |
| Magnification | 40×–100× (variable zoom) |
| Power Supply | 220 V ±22 V, 50 Hz ±1 Hz |
| Dimensions | 269 × 160 × 435 mm |
| Net Weight | 4 kg |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | SGW® X-5 |
| Temperature Range | Ambient to 360 °C |
| Heating Rates | 0.2, 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0 °C/min |
| Temperature Repeatability | ±0.3 °C (at 1.0 °C/min) |
| Temperature Accuracy | Capillary Method — ≤200 °C: ±0.4 °C |
| >200 °C | ±0.7 °C |
| Hot Stage Method — Ambient–100 °C | ±0.4 °C |
| 100–200 °C | ±0.6 °C |
| 200–300 °C | ±0.8 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, Length 90 mm |
| Sample Capacity | 1 sample per run |
| Temperature Resolution | 0.1 °C |
| Display | 7-inch TFT capacitive touchscreen |
| Data Storage | 1000 measurement records |
| Interface | USB host/device (PC connectivity & USB flash drive support) |
| Power Supply | 220 V ±10%, 50 Hz ±1 Hz, 150 W |
| Dimensions (W×D×H) | 310 × 230 × 505 mm |
| Net Weight | 4.0 kg |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | SGW®-630 |
| Temperature Range | Ambient to 400 °C |
| Heating Rates | 0.2, 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.2 °C/min), ±0.3 °C (at 1.0 °C/min) |
| Temperature Accuracy | ±0.4 °C (≤200 °C), ±0.7 °C (>200 °C) |
| Temperature Resolution | 0.1 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, Length 90 mm |
| Sample Capacity | 3 capillaries |
| Calibration Points | 8-point |
| Data Storage | 16 GB internal |
| Display | 8-inch capacitive touchscreen |
| OS | Embedded Windows-based platform |
| Compliance | Meets USP <741>, EP 2.2.17, JP 2.60, FDA 21 CFR Part 11, GLP/GMP audit trail requirements |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | SGW®-650 |
| Temperature Range | Ambient to 400 °C |
| Heating Rates | 0.2, 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0 °C/min |
| Temperature Repeatability | ±0.3 °C at 1.0 °C/min |
| Temperature Accuracy | ±0.4 °C ≤200 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, Length 90 mm |
| Sample Capacity | 5 capillaries simultaneously |
| Temperature Resolution | 0.1 °C |
| Calibration Points | 8-point programmable calibration |
| Data Storage | 16 GB internal |
| Display | 8-inch capacitive touchscreen LCD |
| Operating System | Embedded Windows-based platform |
| Compliance | Meets requirements of Chinese Pharmacopoeia, USP <741>, EP 2.2.17, ISO 11357-3, FDA 21 CFR Part 11 (audit trail, electronic signatures, role-based access control), GLP/GMP data integrity standards |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | SGW®-681 |
| Temperature Range | Ambient to 360 °C |
| Heating Rate | 0.1–20.0 °C/min (continuously adjustable) |
| Temperature Accuracy | ±0.4 °C ≤200 °C |
| Temperature Repeatability | 0.3 °C at 1.0 °C/min |
| Temperature Resolution | 0.1 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, Length 90 mm |
| Sample Capacity | 4 capillaries per run |
| Display | 10.1″ IPS capacitive touchscreen |
| Camera | 720p @ 30 fps |
| Data Storage | 64 GB internal |
| Operating System | Android-based embedded OS |
| Compliance | Compliant with USP <741>, EP 2.2.17, and ChP 0612 melting point determination methods |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | SGW®-682 |
| Temperature Range | Ambient to 360 °C |
| Heating Rate | 0.1–20.0 °C/min (continuously adjustable) |
| Temperature Accuracy | ≤200 °C ±0.4 °C |
| Temperature Repeatability | ±0.3 °C at 1.0 °C/min |
| Temperature Resolution | 0.1 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, Length 90 mm |
| Sample Capacity | 4 capillaries simultaneously |
| Display | 10.1″ IPS capacitive touchscreen |
| Camera | 720p @ 30 fps |
| Data Storage | 64 GB internal |
| Operating System | Android |
| Compliance Options | FDA 21 CFR Part 11 audit trail (optional), GLP/GMP-ready |