Physical Property Testing Instruments
Filter
Showing 61–90 of 12188 results
| Brand | Colloidal Dynamics |
|---|---|
| Origin | USA |
| Model | AcoustoSizer II |
| Particle Size Range | 10 nm – 100 µm |
| Zeta Potential Range | 0.5 nm – 30 µm |
| Temperature Control Range | 10–50 °C |
| Temperature Stability | ±0.1 °C |
| Ultrasonic Frequency Range | 1–20 MHz |
| Measurement Principle | Multi-frequency electroacoustic spectroscopy & ultrasonic attenuation spectroscopy |
| Sample Concentration Range | 0.1–40% v/v |
| Standard Sample Volume | 85 mL (optional 20 mL) |
| Measurement Time | Real-time, sub-second spectral acquisition per parameter |
| Brand | AcroEdge |
|---|---|
| Origin | Imported (Non-Chinese) |
| Model | AV-10 |
| Measurement Principle | Rotational (Couette flow geometry) |
| Torque Sensing | High-resolution electromagnetic torque transducer |
| Speed Control | Closed-loop DC motor with optical encoder feedback |
| Output Interfaces | RS-485, USB 2.0, Ethernet (TCP/IP), 4–20 mA analog output |
| Alarm Outputs | Dual programmable digital relay (Hi/Lo) |
| Temperature Compensation | Built-in RTD input (PT100 compatible) |
| Enclosure Rating | IP65 (sensor head), IP54 (controller unit) |
| Power Supply | 24 VDC ±10% |
| Operating Temperature | −10 to +60 °C (electronics), −20 to +150 °C (wetted sensor parts) |
| Wetted Materials | 316L stainless steel, Hastelloy C-276 optional |
| Air/N₂ Purge Port | Integrated on probe housing |
| Configuration | Modular — separate sensing probe and remote control unit |
| Brand | AcroEdge |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Caisits |
| Price Range | USD 28,000 – 70,000 |
| Brand | AcroEdge |
|---|---|
| Origin | Japan |
| Model | Curea |
| Excitation Wavelength | 365 nm |
| Spot Diameter | 2 mm |
| Working Distance | 43 mm |
| Measurement Time | 0.1 s |
| Dimensions (W×D×H) | 50×75×125 mm |
| Weight | ~900 g |
| Application | Real-time non-contact UV-curable resin cure monitoring |
| Brand | AcroEdge |
|---|---|
| Origin | Japan |
| Model | EU201 |
| Measurement Principle | Laser Displacement + Load Cell-Based Stress Monitoring |
| Temperature Control Range | –50 °C to 300 °C (programmable ramp/soak) |
| Laser Source | 655 nm Class 1 semiconductor diode (220 µW) |
| Displacement Resolution | 2 µm |
| Force Sensing Range | 5 N (standard), optional ranges: 500 mN, 1 N, 2 N, 10 N, 20 N |
| Force Nonlinearity | ±0.5 % RO |
| Force Repeatability | ±0.5 % RO |
| Heating Power | 450 W (3×50 W elements) |
| Cooling Unit Capacity | 450 W (10–25 °C adjustable) |
| Sample Volume | ~1 mL |
| Compliance | ISO 4216:2021, JIS K6941:2019 |
| Key | Brand: AcroEdge |
|---|---|
| Model | Stency |
| Origin | Imported |
| Force Range | 1–20 N (configurable) |
| Force Accuracy | ±0.1% F.S. |
| Displacement Resolution | 0.01 mm |
| Maximum Stroke | 60 mm (uniaxial) |
| Positioning Accuracy | ±0.02 mm |
| Test Speed | 0.1–100 mm/s |
| Data Acquisition Rate | 10 Hz (100 ms interval) |
| Max Data Points per Test | 60,000 |
| Sample Width | up to 50 mm (biaxial), 30 mm (uniaxial) |
| Sample Length | ≥5 mm + gauge length |
| Power Supply | AC 100 V ±10%, 2–3 A |
| Operating Temperature | 0–40 °C |
| Compliance | Designed for ASTM D638, ISO 527, and ISO 11843-compliant tensile evaluation of micro-scale specimens |
| Brand | AcroEdge |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | Syclus |
| Instrument Category | Compact Vibration-Based Fatigue Tester |
| Frequency Range | 1–20 Hz |
| Maximum Displacement Amplitude | ±600 µm |
| Load Capacity | ±25 N (±0.5% nonlinearity) |
| Sample Dimensions | Length 25–35 mm |
| Geometry | Films, Fibers, Thin Specimens |
| Control Interface | USB-connected PC with Dedicated Software |
| Sampling Rate | Up to 2000 pts/sec |
| Data Storage Modes | Linear (N cycles per T minutes) or Logarithmic (10, 100, 1000, …, 10ⁿ cycles) |
| Failure Detection | Programmable load threshold trigger with pre-failure cycle preservation (3 cycles prior to failure) |
| System Dimensions (Tester) | L100 × W100 × H500 mm (vertical orientation) |
| Controller Dimensions | L250 × W250 × H150 mm |
| Tester Mass | ~3 kg |
| Controller Mass | ~5 kg |
| Power Supply | 100 V, 10 A |
| Brand | ACS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A1040 MIRA 3D |
| Frequency Bandwidth | 10–100 kHz |
| Parallel DAQ Channels | 32 |
| Maximum Penetration Depth | 3 m (concrete-dependent) |
| Maximum Coverage Area | 10 × 10 m |
| Frame Rate | 25 Hz (2D), 2 Hz (3D) |
| Battery Life | Up to 10 h per charge |
| Sensor Configuration | 4 × 8 A-DPC® array (expandable) |
| Compliance | T/CECS XXX-202X, JGJ/T 485-2019, DB32/T 3754-2020, DB34/T 5072-2017, DB37/T 5106-2018, DG/TJ 08-2252-2018, DB13(J)/T 8327-2019, DBJ/T-199-2020 |
| Brand | ACS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A1040 MIRA 3D Pro |
| Frequency Bandwidth | 10–100 kHz |
| Parallel DAQ Channels | 64 |
| Maximum Penetration Depth | 4 m (concrete-dependent) |
| Maximum Scanning Area | 10 × 10 m |
| Frame Rate | 12 Hz (2D), 0.3 Hz (3D) |
| Battery Life | Up to 10 h per charge |
| Sensor Configuration | 4 × 16 or 8 × 8 A-DPC® array (expandable) |
| Compliance | T/CECS XXX-202X, JGJ/T 485–2019, DB32/T 3754–2020, DB34/T 5072–2017, DB37/T 5106–2018, DG/TJ 08–2252–2018, DB13(J)/T 8327–2019, DBJ/T–199–2020 |
| Brand | ACS |
|---|---|
| Origin | Hong Kong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | A1052 MultiSONIC |
| Price Range | USD 1–2 (Unit Price Indicative |
| Channels | 32-channel pulser-receiver array |
| Connectivity | Integrated Wi-Fi interface (IEEE 802.11 b/g/n, 2.4 GHz) |
| Power Supply | Rechargeable Li-ion battery (operational autonomy ≥ 6 h) |
| Excitation | Bipolar pulse burst with user-defined frequency, half-cycle duration, and number of half-cycles |
| Compatible Transducers | All ACS dry-point contact ultrasonic transducers (e.g., A101x series, 20–500 kHz nominal bandwidth) |
| Encoding Support | Golay complementary sequence excitation (length up to 64 bits) |
| Software | MATHILDA32 (free demonstration version included) |
| Operating Modes | Pulse-echo, through-transmission, pitch-catch |
| Compliance | CE, RoHS, FCC Part 15 Subpart B |
| Brand | ACS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A1410 Pulsar |
| Price | USD 6,800 (FOB Italy) |
| Brand | ACS |
|---|---|
| Temperature Range Options | 0°C to +150°C (Model B) |
| Internal Volume | 80 L, 150 L, 225 L, 408 L, 800 L, or 1000 L |
| Temperature Uniformity | ±1.5°C |
| Temperature Stability | ±0.5°C |
| Humidity Range | 20–98% RH |
| Humidity Uniformity | ±3% RH |
| Humidity Stability | ±2% RH |
| Heating Rate (non-linear, no-load) | ~3°C/min |
| Cooling Rate (non-linear, no-load) | ~1°C/min |
| Construction | AISI 304 stainless steel interior & exterior |
| Insulation | Rigid polyurethane foam + glass wool |
| Refrigeration System | Hermetic scroll compressors (Tecumseh or Copeland), eco-friendly refrigerant (R404A/R507) |
| Controller | TEMI880 color touchscreen programmable climate controller (English/Chinese UI) |
| Air Circulation | Wide-band vertical airflow (top-out, bottom-in) |
| Condensation Management | Automatic drain system with digital pressure monitoring |
| Compliance | Designed for ISO 16750-4, IEC 60068-2-14, MIL-STD-810H, JIS Z 8701, and ASTM D4332 environmental stress testing |
| Brand | ACS |
|---|---|
| Origin | Russia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A1040 MIRA |
| Pricing | Upon Request |
| Brand | ACS |
|---|---|
| Origin | Italy |
| Model | SU250 |
| Instrument Type | Upright Chamber |
| Temperature Range | −40 °C to +180 °C |
| Humidity Range | 10 % to 98 % RH |
| Temperature Uniformity | ≤ ±0.5 °C |
| Humidity Uniformity | ≤ ±3 % RH (at >75 % RH) / ≤ ±5 % RH (at ≤75 % RH) |
| Heating Rate | 3 °C/min |
| Internal Dimensions (W×D×H) | 600 × 600 × 700 mm |
| Compliance | IEC 60068-3-5, IEC 60068-3-6, EN 60068-2-1, EN 60068-2-2, EN 60068-2-14, EN 60068-2-30 |
| Brand | AcuiTik |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Line | NS-Micro Series |
| Wavelength Range | 190–1000 nm |
| Thickness Measurement Range | 1–100 µm |
| Measurement Accuracy | ±1 nm or ±0.2% (whichever is greater) |
| Measurement Precision | 0.02 nm (1σ, 100 measurements on 500 nm SiO₂ reference) |
| Stability | 0.05 nm (2σ mean drift over 20 operational days) |
| Measurement Speed | <1 s per static point |
| Objective Options | 5×, 10×, 15×, 20×, 50×, 100× |
| Spot Size Range | 1–100 µm |
| Sample Diameter Capacity | 1 mm to ≥300 mm |
| Light Source | Deuterium + Tungsten-Halogen Lamp |
| Brand | AcuiTik |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | NS-20 |
| Price Range | USD 7,000 – 35,000 |
| Wavelength Range | 190–1700 nm (configurable UV/VIS/NIR variants) |
| Thickness Measurement Range | 1 nm – 250 µm (dependent on optical configuration) |
| Accuracy | ±1 nm or ±0.2% (UV variant) |
| Precision (repeatability) | 0.02 nm (UV/VIS), 0.1 nm (NIR) |
| Stability (8-hour drift) | ≤0.05 nm (UV/VIS), ≤0.12 nm (NIR) |
| Spot Size | 1.5 mm diameter |
| Measurement Speed | <1 s per single-point acquisition |
| Light Source | Tungsten-halogen + Deuterium lamp (UV), Tungsten-halogen only (VIS/NIR) |
| Sample Diameter Compatibility | 1 mm – 300 mm (custom larger stages available) |
| Brand | AcuiTik |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | NS-20 Pro |
| Price | Upon Request |
| Wavelength Range | 400–700 nm (non-UV, non-actinic) |
| Measurement Range | 15 nm – 1.5 mm |
| Measurement Precision | < 0.02 nm (static repeatability) |
| Spot Size | Standard 0.2 mm (optional micro-spot configuration available) |
| Configuration Options | Benchtop, Portable, and In-Line Integration Capable |
| Brand | AcuiTik |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | NS-30 |
| Wavelength Range | 190–1700 nm (configurable UV/VIS/NIR variants) |
| Thickness Measurement Range | 1 nm – 250 µm |
| Accuracy | ±1 nm or ±0.2% (UV variant) |
| Precision | 0.02 nm (UV/VIS), 0.1 nm (NIR) |
| Stability | ≤0.05 nm (UV/VIS), ≤0.12 nm (NIR) |
| Spot Size | 1.5 mm |
| Single-Measurement Time | <1 s |
| Sample Diameter Capacity | 1 mm – 300+ mm |
| Automated Stage Travel | Up to 450 mm × 450 mm |
| Stress & Bow Measurement | Yes |
| Brand | AcuiTik |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | NS-OEM |
| Wavelength Range | 190–1100 nm |
| Thickness Measurement Range | 1 nm – 1 mm |
| Accuracy | ±2 nm or ±0.2% |
| Static Repeatability | ±0.02 nm |
| Spot Size | 1.5 mm |
| Measurement Speed | <1 s per acquisition |
| Light Source | Tungsten-Halogen Lamp (with optional Deuterium lamp) |
| Probe-to-Host Interface | Fiber Optic (standard length 1.3 m, up to 20 m configurable) |
| Probe Dimensions | Ø19 mm × 86 mm |
| Power Supply | 90–264 VAC, 47–63 Hz |
| Brand | AcuiTik |
|---|---|
| Origin | China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | NS-Touch |
| Wavelength Range | 190–1700 nm |
| Thickness Measurement Range | 0.02 µm – 250 µm |
| Thickness Accuracy | ±0.01 µm or ±0.2% (whichever is greater) |
| Brand | AcuiTik |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | NS-Vista |
| Wavelength Range | 190–1700 nm |
| Thickness Measurement Range | 1 nm – 250 µm |
| Accuracy | ±1 nm or ±0.2% (UV configuration) |
| Precision | 0.02 nm (UV/Vis), 0.1 nm (NIR) |
| Stability | 0.05 nm (UV/Vis), 0.12 nm (NIR) |
| Spot Size | Adjustable from 0.2 mm to 1.5 mm |
| Measurement Speed | <1 s per acquisition |
| Light Source | Tungsten-halogen + Deuterium lamp (UV), Tungsten-halogen (Vis/NIR) |
| Sample Diameter Compatibility | 1 mm – 300 mm (or larger) |
| Brand | AD Systems |
|---|---|
| Origin | France |
| Model | ST10 |
| Compliance | ASTM D4740 |
| Operating Temperature | Filter Paper 100 °C ±0.2 °C, Fuel Sample 93 °C ±0.2 °C |
| Display | 7-inch capacitive touchscreen |
| Data Storage | Up to 100,000 test records with full image metadata |
| Connectivity | RJ45 Ethernet port, 4× USB 2.0 ports |
| Dimensions (W×D×H) | 420 × 350 × 222 mm |
| Weight | 9 kg |
| Power Supply | 230 V AC, 2 A, 50 Hz |
| Sample Handling | Manual droplet deposition via supplied micro-pipette |
| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Model | F-CAL |
| Measurement Principle | Heat Flow Method |
| Thermal Resistance Range | 1×10⁻⁵ m²·K/W |
| Repeatability | <2% fluctuation |
| Test Atmosphere | Ambient air |
| Hot-Side Temperature Setting | 50°C |
| Sample Geometry | Square, 25 mm or 40 mm edge length, thickness 1–5 mm |
| Instrument Type | Steady-State Thermal Resistance Analyzer |
| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Model | F-PEM |
| Operating Atmosphere | Ambient Air |
| Temperature Range | Room Temperature to 600 °C (Heating Zone) |
| Sample Size | Square, 40 mm × 40 mm × (5–30) mm Thickness |
| Power Supply | AC200V, 5 kW (Main Unit) |
| Dimensions | W600 × D600 × H1700 mm |
| Weight | ~120 kg |
| Contact Force | Up to 160 kgf (via Constant-Pressure Spring Mechanism) |
| Measured Parameters | Maximum Output Power (P<sub>max</sub>), Heat Flow Rate (Q), Thermoelectric Conversion Efficiency (η) |
| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Model | HT-RTA59HD |
| Heating Method | High-Power Focused Halogen Lamp |
| Max Temperature | 1800 °C (achieved in ≤10 s for □15 mm samples) |
| Sample Chamber Atmosphere | Dual-gas inlet (N₂ and Ar), quartz tube encapsulation |
| Cooling | Forced-air cooling for lamp assembly |
| Form Factor | Benchtop, manual slide-rail sample loading |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments |
| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Advance Riko |
| Pricing | Available Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LaserPIT |
| Instrument Type | Laser Flash Method (AC-mode variant) |
| Temperature Range | Ambient to 200 °C |
| Sample Dimensions (Bulk) | 2.5–5 mm width × 30 mm length × 3–500 µm thickness |
| Sample Dimensions (Thin Films on Substrates) | 2.5–5 mm width × 30 mm length × 100–1000 nm thickness |
| Measurement Atmosphere | Vacuum (< 0.02 Pa) |
| Film Analysis Capability | Differential AC-mode thermal diffusivity extraction for anisotropic and substrate-supported thin films |
| Brand | Advance Riko |
|---|---|
| Origin | Japan |
| Model | Mini-PEM |
| Operating Temperature Range (Hot Side) | 50–500 °C |
| Sample Dimensions | 2–10 mm × 1–20 mm (square/rectangular bulk) |
| Atmosphere | Vacuum-compatible |
| Measured Parameters | Thermoelectric conversion efficiency (η), electrical power output, heat flux |
| Measurement Principle | Simultaneous four-probe electrical characterization + calibrated heat flux sensor (thermopile-based) |
| Compliance | Designed for ASTM E3049–22 (Standard Practice for Measuring Thermoelectric Module Efficiency) and ISO 14405-1:2016 (Geometrical product specifications) alignment |
| Brand | Advance Riko |
|---|---|
| Origin | Japan |
| Model | Peltier Evaluation System |
| Measurement Atmosphere | Vacuum |
| Temperature Range | 27–80 °C |
| Sample Dimensions | Square, 10–25 mm side length, thickness ≤ 3 mm |
| Measured Parameters | ΔTₘₐₓ (maximum temperature difference), Qc,ₘₐₓ (maximum cooling power), COP (coefficient of performance) |
| Compliance | Designed for thermoelectric module characterization per ISO 14405-1 and ASTM D5470 practices |
| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Model | PEM-2 |
| Maximum Temperature Gradient | 500 °C (up to 800 °C heating surface) |
| Sample Geometry | Square, 20/30/40 mm × 5–30 mm thickness |
| Contact Pressure | 2 MPa (at 30 mm square sample) |
| Atmosphere | Inert gas compatible |
| Measurement Method | One-dimensional heat flux input method |
| Measured Parameters | Thermoelectric conversion efficiency (η), electrical power output (P), thermal input flux (Q) |
| Heating System | High-precision infrared gold-mirror furnace |
| Cooling System | Integrated water-cooled lower stage |
| Load Control | Automated variable resistive load adjustment |
| Software | Fully integrated control with thermal stability detection, real-time data logging, and automated test sequencing |
