Physical Property Testing Instruments
Filter
Showing 10831–10860 of 11640 results
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,200 (FOB Shanghai, ex-factory reference only) |
| Internal Chamber Dimensions | 650 × 1100 × 600 mm (D×W×H) |
| Overall Dimensions | 1050 × 1550 × 1350 mm (D×W×H) |
| Temperature Range | RT+10°C to 70°C |
| Humidity Capacity | ≥95% RH |
| Lamp-to-Specimen Distance | 50 mm |
| Lamp Spacing | 35 mm |
| Irradiance Output | UVA-340 @ 0.68 W/m² (340 nm peak), UVB-313 @ 0.60 W/m² (313 nm peak) |
| UVA Spectral Band | 320–400 nm |
| UVB Spectral Band | 280–320 nm |
| Temperature Uniformity | ≤ ±2°C |
| Temperature Stability | ≤ ±0.5°C |
| Standard Specimen Size | 75 × 150 mm |
| Timer Range | 0–99 h |
| Temperature Sensor | PT-100 Platinum Resistance Thermometer |
| Control System | PID + TSSR Synchronized Digital Regulation |
| Electrical Components | Delixi (China) industrial-grade contactors & relays |
| Lamp Current Monitoring | Real-time analog display |
| Exterior & Interior Material | SUS304 stainless steel, precision TIG-welded construction |
| Sample Holder | Adjustable-height SUS304 rack with leveling feet and casters |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Rainfall Intensity | 600–3600 mm/h |
| Spray Arm Radius | 375 mm |
| Spray Arm Diameter | φ15 mm |
| Spray Arm Oscillation Angle | ±45° to ±90° |
| Nozzle Diameter | φ0.4 mm or φ0.8 mm |
| Nozzle Spacing | 50 mm |
| Turntable Speed | 1–10 rpm |
| Timer Range | 1 s – 99 h 99 min 99 s |
| Rain Cycle Setting | 1 s – 99 h |
| Internal Chamber Dimensions | 800 × 800 × 800 mm |
| Construction | ST12 Cold-Rolled Steel Outer Shell + Phosphated & Powder-Coated Finish |
| Interior | Seamless Welded SUS304 Stainless Steel |
| Spray Pipes | SUS304 Stainless Steel |
| Turntable Material | Stainless Steel Plate |
| Water Filtration | Ultra-Fine Stainless Steel Mesh Filter |
| Water Lift System | Pump-Based |
| Water Level Control | Float Switch |
| Radiation Measurement | Fiber-Optic Coupled Radiometer |
| Lamp Cooling | Closed-Loop Chilled Water Circulation System |
| Temperature Monitoring | Wireless Black Panel Thermometer (BPT) / Black Standard Thermometer (BST) |
| Safety Interlock | Coolant Flow–Dependent Xenon Lamp Ignition & Auto-Shutdown on Failure |
| Compliance | GB/T 2423.23–1990, GB/T 2423.38–1990, GB/T 4208–1993, GB/T 10485–1993, GB/T 4857.9–1992, GB/T 2014.9 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 5,300 (approx. based on ¥38,000) |
| Chamber Models | OK-XD-100 / OK-XD-225 / OK-XD-500 / OK-XD-1000 |
| Internal Dimensions (W×D×H, cm) | 50×50×40 / 50×75×60 / 80×80×80 / 100×100×100 |
| Temperature Range | 0–150°C (chamber), 40–85°C (black panel) |
| Humidity Range | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Control Accuracy | ±0.5°C / ±2.0% RH |
| Uniformity | ±2.0°C / ±3.0% RH |
| Irradiance | 550 W/m² ±10% (300–800 nm) or 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ~1500 h |
| Spray Cycle | 1–999 min (intermittent/continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 5,300 (Reference Only) |
| Chamber Models | OK-XD-100 / OK-XD-225 / OK-XD-500 / OK-XD-1000 |
| Internal Dimensions (W×D×H, cm) | 50×50×40 / 50×75×60 / 80×80×80 / 100×100×100 |
| Overall Dimensions (W×D×H, cm) | 100×170×90 / 110×190×100 / 140×190×130 / 165×210×150 |
| Temperature Range | 0–150 °C (Chamber), 40–85 °C (Black Panel) |
| Humidity Range | 20–75% RH (Light Cycle), 20–98% RH (Dark Cycle) |
| Control Accuracy | ±0.5 °C (Temp), ±2.0% RH (Humidity) |
| Uniformity | ±2.0 °C (Temp), ±3.0% RH (Humidity) |
| Irradiance | 550 W/m² ±10% (300–800 nm), 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ≈1500 h |
| Spray Duration | 1–999 min (Intermittent or Continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Holder | Dual-layer flat mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 5,300 (Reference Only) |
| Chamber Models | OK-XD-100 / OK-XD-225 / OK-XD-500 / OK-XD-1000 |
| Internal Dimensions (W×D×H, cm) | 50×50×40 / 50×75×60 / 80×80×80 / 100×100×100 |
| Temperature Range | 0–150°C (Chamber), 40–85°C (Black Panel) |
| Humidity Range | 20–75% RH (Light Cycle), 20–98% RH (Dark Cycle) |
| Temp. Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temp./RH Uniformity | ±2.0°C / ±3.0% RH |
| Spectral Range | 300–800 nm (550 W/m² ±10%) and 300–1200 nm (1000 W/m² ±10%) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ≈1,500 h |
| Spray Duration | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Interior Material | SUS304 stainless steel |
| Exterior Material | SUS304 stainless steel or powder-coated steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 5,300 (Reference Only) |
| Chamber Models | OK-XD-100 / OK-XD-225 / OK-XD-500 / OK-XD-1000 |
| Internal Dimensions (W×D×H, cm) | 50×50×40 / 50×75×60 / 80×80×80 / 100×100×100 |
| External Dimensions (W×D×H, cm) | 100×170×90 / 110×190×100 / 140×190×130 / 165×210×150 |
| Temperature Range | 0–150°C (Chamber), 40–85°C (Black Panel) |
| Humidity Range | 20–75% RH (Light Cycle), 20–98% RH (Dark Cycle) |
| Temp. Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temp. Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Irradiance | 550 W/m² ±10% (300–800 nm) or 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ~1,500 h |
| Spray Duration | 1–999 min (Intermittent or Continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer mesh tray or 500-mm-diameter rotating turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | OK |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,300–14,800 (FOB) |
| Temperature Range | 0–150°C (Chamber), 40–85°C (Black Panel) |
| Humidity Range | 20–98% RH |
| Irradiance | 550 W/m² ±10% (300–800 nm) / 1000 W/m² ±10% (300–1200 nm) |
| Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ≥1500 h |
| Spray Cycle | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500 mm rotary turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Compliance | GB/T 8427, GB/T 16422-2, GB/T 8430, ISO 4892-2, ASTM D529, GB/T 14576, GB/T 15102-2006, GB/T 15104-2006 |
| Brand | OEM / Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,300 (Reference Only) |
| Chamber Models | OK-XD-100 |
| Internal Dimensions (W×D×H, cm) | 50×50×40 |
| Temperature Range | 0–150°C (Chamber), 40–85°C (Black Panel) |
| Humidity Range | 20–75% RH (Light Cycle), 20–98% RH (Dark Cycle) |
| Temp. Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temp. Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Irradiance | 550 W/m² ±10% (300–800 nm) or 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ≈1500 h |
| Spray Duration | 1–999 min (intermittent/continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Interior Material | SUS304 stainless steel |
| Exterior Material | SUS304 stainless steel or powder-coated steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 5,300 (approx.) |
| Chamber Models | OK-XD-100 / OK-XD-225 / OK-XD-500 / OK-XD-1000 |
| Internal Dimensions (cm) | 50×50×40 / 50×75×60 / 80×80×80 / 100×100×100 |
| Temperature Range | 0–150°C (chamber), 40–85°C (black panel) |
| Humidity Range | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Control Accuracy | ±0.5°C / ±2.0% RH |
| Uniformity | ±2.0°C / ±3.0% RH |
| Spectral Range | 300–800 nm (550 W/m² ±10%) and 300–1200 nm (1000 W/m² ±10%) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ~1,500 h |
| Spray Duration | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500-mm-diameter rotating turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | OK |
|---|---|
| Model | OK-XD-100 / OK-XD-225 / OK-XD-500 / OK-XD-1000 |
| Chamber Type | Air-Cooled Long-Arc Xenon Lamp-Based Environmental Aging Test System |
| Light Spectrum | Full-Spectrum Solar Simulation (300–1200 nm) |
| Irradiance Control | 300–800 nm @ 550 W/m² ±10% |
| Black Panel Temperature Range | 40–85 °C |
| Chamber Temperature Range | 0–150 °C |
| Humidity Range | 20–98 % RH (dark cycle), 20–75 % RH (light cycle) |
| Humidity Accuracy | ±2.0 % RH |
| Temperature Accuracy | ±0.5 °C |
| Uniformity | ±2.0 °C (temp), ±3.0 % RH (humidity) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ~1500 h at nominal irradiance |
| Spray Function | Adjustable interval (1–999 min), continuous or intermittent, pressure 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500 mm diameter rotating drum (0–3 rpm) |
| Interior Material | SUS304 stainless steel |
| Exterior Material | SUS304 stainless steel or powder-coated steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Compliance Standards | GB/T 8427, GB/T 16422-2, GB/T 8430, ISO 4892-2, ASTM D529, GB/T 14576, GB/T 15102-2006, GB/T 15104-2006 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 5,300 (approx.) |
| Temperature Range | 0–150°C (chamber), 40–85°C (black panel) |
| Humidity Range | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Irradiance | 550 W/m² ±10% (300–800 nm), 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ≈1500 h |
| Spray Duration | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Compliance | GB/T 8427, GB/T 16422-2, GB/T 8430, ISO 4892-2, ASTM D529, GB/T 14576, GB/T 15102-2006, GB/T 15104-2006 |
| Brand | OK Instruments |
|---|---|
| Model | OK-XD-100 / OK-XD-225 / OK-XD-500 / OK-XD-1000 |
| Chamber Interior Dimensions (W×D×H) | 50×50×40 cm to 100×100×100 cm |
| Temperature Range | 0–150°C (chamber), 40–85°C (black panel) |
| Humidity Range | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Irradiance Control | 550 W/m² ±10% (300–800 nm), 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ≈1500 h |
| Spray Cycle | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Compliance | GB/T 8427, GB/T 16422-2, GB/T 8430, ISO 4892-2, ASTM D529, GB/T 14576, GB/T 15102-2006, GB/T 15104-2006 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 5,300 (approx.) |
| Temperature Range | 0–150°C (chamber), 40–85°C (black panel) |
| Humidity Range | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Irradiance | 550 W/m² ±10% (300–800 nm), 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ~1,500 hours |
| Spray Duration | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Internal Dimensions (cm) | 50×50×40 (OK-XD-100) to 100×100×100 (OK-XD-1000) |
| Construction | Interior — SUS304 stainless steel |
| Control Accuracy | ±0.5°C (temperature), ±2.0% RH (humidity) |
| Uniformity | ±2.0°C (temperature), ±3.0% RH (humidity) |
| Compliance Standards | GB/T 8427, GB/T 16422-2, ISO 4892-2, ASTM D529, GB/T 14576, GB/T 15102-2006, GB/T 15104-2006 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 5,300 (approx.) |
| Internal Dimensions (cm) | 50×50×40 / 50×75×60 / 80×80×80 / 100×100×100 |
| Temperature Range | 0–150°C (chamber), 40–85°C (black panel) |
| Humidity Range | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Control Accuracy | ±0.5°C / ±2.0% RH |
| Uniformity | ±2.0°C / ±3.0% RH |
| Irradiance | 550 W/m² ±10% (300–800 nm) or 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ~1500 h |
| Spray Duration | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500-mm-diameter rotating drum (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | OK |
|---|---|
| Model | OK-XD-100 / OK-XD-225 / OK-XD-500 / OK-XD-1000 |
| Chamber Type | Benchtop to Floor-Standing Xenon Arc Exposure System |
| Light Source | Long-Arc Air-Cooled Xenon Lamp (Full-Spectrum Solar Simulation) |
| Spectral Range | 300–800 nm (550 W/m² ±10%) and 300–1200 nm (1000 W/m² ±10%) |
| Black Panel Temperature Range | 40–85°C |
| Chamber Temperature Range | 0–150°C |
| Humidity Control | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Humidity Accuracy | ±2.0% RH |
| Temperature Accuracy | ±0.5°C |
| Uniformity | ±2.0°C (temp), ±3.0% RH (humidity) |
| Irradiance Control | Closed-loop digital feedback with calibrated broadband sensor |
| Water Spray | Programmable intermittent/continuous mode (1–999 min), pressure 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Lamp Life | ~1500 h at rated irradiance |
| Filter System | Precision daylight-filtered quartz envelope for stable CIE standard solar spectrum replication |
| Compliance | ASTM G155, ISO 4892-2, GB/T 16422.2, GB/T 8427, GB/T 8430, GB/T 14576, GB/T 15102–2006, GB/T 15104–2006, AATCC TM16, JIS D 0205 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 5,300 (Reference Only) |
| Chamber Models | OK-XD-100 / OK-XD-225 / OK-XD-500 / OK-XD-1000 |
| Internal Dimensions (W×D×H, cm) | 50×50×40 / 50×75×60 / 80×80×80 / 100×100×100 |
| Temperature Range | 0–150°C (Chamber), 40–85°C (Black Panel) |
| Humidity Range | 20–75% RH (Light Cycle), 20–98% RH (Dark Cycle) |
| Control Accuracy | ±0.5°C / ±2.0% RH |
| Uniformity | ±2.0°C / ±3.0% RH |
| Spectral Range | 300–800 nm (550 W/m² ±10%) and 300–1200 nm (1000 W/m² ±10%) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ~1,500 h |
| Water Spray Duration | 1–999 min (Intermittent or Continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500-mm-diameter rotating turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 5,300 (Reference Only) |
| Chamber Models | OK-XD-100 / OK-XD-225 / OK-XD-500 / OK-XD-1000 |
| Internal Dimensions (W×D×H, cm) | 50×50×40 / 50×75×60 / 80×80×80 / 100×100×100 |
| Temperature Range | 0–150°C (Chamber), 40–85°C (Black Panel) |
| Humidity Range | 20–75% RH (Light Cycle), 20–98% RH (Dark Cycle) |
| Control Accuracy | ±0.5°C / ±2.0% RH |
| Uniformity | ±2.0°C / ±3.0% RH |
| Spectral Range | 300–800 nm (550 W/m² ±10%) and 300–1200 nm (1000 W/m² ±10%) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ~1,500 h |
| Spray Duration | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | +10°C to +70°C |
| Humidity Range | ≥95% RH |
| Internal Chamber Dimensions (W×H×D) | 1000 × 1000 × 1000 mm |
| External Dimensions (W×H×D) | 1650 × 2100 × 1500 mm |
| Sample Holder Capacity | 75 × 150 mm (Standard) |
| Chamber Construction | SUS304 Stainless Steel Interior, Cold-Rolled Steel Exterior with Phosphating & Baking Finish |
| Irradiance Control | Adjustable Sample Height for Uniformity Compliance per GB/T 19394–2003 (±15%) |
| Optical Filter | Low-Iron Tempered Glass (5 mm) |
| Reflector Material | High-Purity Aluminum Oxide Plate |
| Circulation Pump | Magnetic Drive Circulating Pump |
| Controller | Fuji Electric PID Temperature Controller, Moeller Programmable Logic Controller (PLC) |
| Sensor | PT100 Platinum Resistance Thermometer |
| Temperature Resolution | 0.1°C |
| Protection Functions | Over-Temperature Protection, Phase-Loss Protection |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Internal Dimensions (W×D×H) | 1000 × 1000 × 1000 mm |
| External Dimensions (W×D×H) | 1850 × 1350 × 1550 mm |
| UV-A Spectral Range | 320–380 nm |
| Irradiance Control Range | 0.7 W/m² @ 340 nm (adjustable) |
| Humidity Range (Irradiation Mode) | 45–80% RH |
| Condensation Humidity | ≥95% RH |
| Condensation Temperature Range | 40–60°C (±3°C tolerance) |
| Light Exposure Temperature Range | 50–60°C (±3°C tolerance) |
| Black Panel Temperature Range | 30–60°C (±1°C tolerance) |
| Temperature Resolution | 0.1°C |
| Water Tray Depth | ≤30 mm with Auto-Water Supply Control |
| Irradiance Measurement | Fixed-position UV radiometer with high-accuracy digital display |
| Cycle Programming | Independent and combined irradiation/condensation cycles, programmable up to 999 hours per segment |
| Electrical Components | Schneider (France) control modules |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Radiation Intensity | ≤50 W/m² (per GB/T 19394–2003, Clause 5) |
| Temperature Range | 40–70 °C |
| Temperature Uniformity | ±2 °C |
| Temperature Fluctuation | ±0.5 °C |
| Chamber Dimensions (W×D×H) | 1000 × 1000 × 1000 mm |
| Xenon Lamp Quantity | 4 pcs |
| Lamp Power | 40 W each |
| Black Panel Thermometer | Aluminum substrate |
| Sample Mounting Options | Rotating turntable or stainless steel shelf (user-selectable) |
| UV Spectral Options | UV-A (295–360 nm) or UV-B (280–315 nm) |
| Control System | TEMI-880 16-bit true-color touchscreen, 100 programmable profiles × 100 segments/profile, PID temperature regulation with overshoot suppression |
| Communication Interface | RS-485 for remote PC-based monitoring and control |
| Spray Nozzle | 1 unit |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | −70 °C to +100 °C |
| Humidity Range | 10–98% RH |
| Humidity Uniformity | ±3% RH |
| Temperature Uniformity | ±2 °C |
| Rainfall Duration | 0–9999 min (continuous) |
| Rainfall Cycle | 0–240 min (intermittent) |
| Xenon Lamp Power | 6 kW ±5% |
| Spectral Range | 290–400 nm |
| Irradiance Control | 0.35–0.65 W/m²/nm @ 340 nm |
| Sample Rack Rotation | 1 rpm, 360° |
| Lamp-to-Sample Distance | 300–375 mm |
| Refrigerant | R404A |
| Cooling System | Air-cooled, hermetic French Tecumseh compressor |
| Humidity Control | Direct steam injection + dew-point contact dehumidification |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, SAE J2412, GB/T 16422.2, GB/T 1865, IEC 60068-2-5 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Chamber Dimensions (W×H×D) | 500 × 700 × 600 mm |
| External Dimensions | Custom-Fit Enclosure |
| Total Power Consumption | 9 kW |
| Lamp Configuration | Single Air-Cooled 1.8 kW Xenon Arc Lamp |
| Spectral Range | 290–800 nm |
| Irradiance (290–800 nm) | 550 W/m² |
| Black Panel Temperature Range | 63 °C / 100 °C (selectable) |
| Temperature Range | RT to +80 °C |
| Temp. Uniformity | ±2.0 °C |
| Temp. Stability | ±0.5 °C |
| Humidity Range | 45–90 %RH |
| Humidity Control Accuracy | ≤ ±2 %RH |
| Water Spray Nozzle Diameter | Ø0.8 mm |
| Spray Duration | 0–9999 min (continuous) |
| Spray Cycle Interval | 0–240 min (intermittent) |
| Sample Rack Distance from Lamp | 230–280 mm |
| Heating Power | 3 kW |
| Humidification Power | 1.5 kW |
| Filter | Single Borosilicate Glass Daylight Filter |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,300 (Reference Only) |
| Chamber Models | OK-XD-100 / OK-XD-225 / OK-XD-500 / OK-XD-1000 |
| Internal Dimensions (W×D×H, cm) | 50×50×40 / 50×75×60 / 80×80×80 / 100×100×100 |
| Temperature Range | 0–150°C (Chamber), 40–85°C (Black Panel) |
| Humidity Range | 20–75% RH (Light Cycle), 20–98% RH (Dark Cycle) |
| Control Accuracy | ±0.5°C / ±2.0% RH |
| Uniformity | ±2.0°C / ±3.0% RH |
| Spectral Range | 300–800 nm (550 W/m² ±10%), 300–1200 nm (1000 W/m² ±10%) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ~1500 h |
| Spray Duration | 1–999 min (Intermittent or Continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Holder | Dual-layer mesh tray or 500 mm diameter rotating turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 5,300 (approx.) |
| Brand | Xepics |
|---|---|
| Origin | Italy |
| Model | HVB |
| Voltage Range | Up to 30 kV |
| Liquid Conductivity Detection Limit | ≥1 µS/cm |
| Sample Throughput | 120 containers/min |
| Compatible Containers | Vials, Ampoules, Prefilled Syringes, IV Bags, Blow-Fill-Seal (BFS) & Form-Fill-Seal (FFS) containers |
| Dimensions (W×D×H) | 190 × 85 × 127 cm |
| Power Supply | 110–240 VAC, 50–60 Hz, 2 kW |
| Control System | Windows 10 PC with 8" Touchscreen Interface |
| Communication | Ethernet |
| Compliance | Designed to support USP <1207>, ISO 11607-2, ASTM F2338, and FDA 21 CFR Part 11 data integrity requirements |
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | XG6000 Series |
| Quotation | Upon Request |
| Dimensions (L×W×H) | 1430 × 848 × 1950 mm |
| Power Supply | 220 V, 10 A, 50–60 Hz |
| Control System | Industrial PC with Windows 10 64-bit |
| Tray Compatibility | 7″–15″, thickness 6–80 mm |
| Barcode Scanning | Integrated |
| Label Printing | Zebra thermal printer |
| System Integration | MES/ERP/WMS (customizable) |
| X-ray Source | Low-energy side-window microfocus tube |
| Tube Voltage | 50 kV (cross-compatible) |
| Tube Current | 0–1000 µA |
| Max Output Power | 50 W |
| Detector | Flat-panel detector |
| Field of View | 434 mm × 434 mm |
| Pixel Matrix | 3072 × 3072 |
| Spatial Resolution | 3.6 lp/mm |
| Radiation Leakage | <1 µSv/hour |
| Safety Interlock | Door-activated beam inhibition |
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer | Zhengye Technology Co., Ltd. |
| Model | XG6300 |
| Dimensions (L×W×H) | 1430 × 848 × 1950 mm |
| Power Supply | 220 V, 10 A, 50–60 Hz |
| Operating System | Windows 10 Pro 64-bit Industrial PC |
| Compatible Tray Sizes | 7″–15″ (178–381 mm), Tape Width: 6–80 mm |
| X-ray Source | Low-energy side-window microfocus tube, 50 kV nominal voltage, 0–1000 µA current, max. 50 W output |
| Detector | Flat-panel detector, FOV: 434 × 434 mm, Pixel Matrix: 3072 × 3072, Spatial Resolution: 3.6 lp/mm |
| Radiation Leakage | <1 µSv/h at 5 cm from enclosure surface |
| Safety Interlock | Dual-door interlocked shutdown, automatic beam inhibition upon door opening |
| Labeling | Integrated Zebra thermal printer for barcode/label generation |
| System Integration | OPC UA and RESTful API support for MES/ERP/WMS bidirectional data exchange |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | TC3200L |
| Measurement Principle | Transient Hot Wire (THW) Method |
| Temperature Range | Ambient to 200 °C |
| Pressure Range | 0.1–15 MPa (optional pressure control) |
| Thermal Conductivity Range | 0.0005–5 W/(m·K) |
| Resolution | 0.0001 W/(m·K) |
| Accuracy | ±3% |
| Repeatability | ±3% |
| Sample Volume Requirement | ≥40 mL |
| Measurement Time | ≤2 s |
| Sample Forms | Liquids and gases |
| Test Atmospheres | Vacuum, air, inert gas |
| Dimensions (L×W×H) | 550×500×650 mm |
| Compliance Standards | ASTM D2717, ASTM D7896 |
| Data Interface | USB |
| Operating System | Windows |
| Brand | Xiatech |
|---|---|
| Model | TC3300 |
| Measurement Principle | Transient Hot Wire Method |
| Temperature Range | –150 °C to Ambient |
| Thermal Conductivity Accuracy | ±5% |
| Repeatability | ±3% |
| Sample Forms | Solid, Paste, Powder, Liquid |
| Sample Dimensions | ≥25 mm (solid edge length) |
| Test Atmosphere | Air |
| Compliance | ASTM C1113, ASTM D5930, GB/T 10297, GB/T 11205 |
| Maximum Operating Pressure | High-Pressure Compatible |
| Sample Throughput | Single-sample per cycle |