Polymerase Chain Reaction Instrument
Filter
Showing 1–30 of 90 results
| Brand | ACV |
|---|---|
| Model | BloFlu 96/96Pro |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well and 384-well formats |
| Heating Rate | 5°C/s |
| Temperature Accuracy | ±0.2°C |
| Well-to-Well Temperature Uniformity | ±0.3°C |
| Excitation/Detection Technology | Fixed-Optics Light-Path System (Patented “Light-Shuttle” Architecture) |
| Calibration | Factory-Pre-Calibrated for All Fluorescence Channels |
| Control Interface | Integrated Touchscreen with Real-Time Signal Monitoring |
| Data Handling | Automated Data Transfer and On-Device Analysis |
| Thermal Gradient Function | Programmable Linear Gradient Across Block (Spanning up to 30°C) |
| Brand | ACV |
|---|---|
| Origin | Shandong, China |
| Model | MoleDete C |
| Instrument Type | Gradient Thermal Cycler |
| Sample Throughput | Interchangeable reaction modules including 96×0.2 mL gradient single-block, 96×0.2 mL / 48×0.5 mL gradient deep-well block, dual 48×0.2 mL gradient block, 384-well single-block gradient module, and qPCR gradient module |
| Max Heating/Cooling Rate | 5 °C/sec (with optional rapid module) |
| Temperature Accuracy | ±0.2 °C |
| Well-to-Well Temperature Uniformity | ±0.4 °C (within 10 sec at 90 °C) |
| Brand | AGDIA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | RF1604 |
| Sample Throughput | 8 samples per run |
| Heating Rate | 1°C per 10 seconds |
| Temperature Accuracy | ±0.1°C |
| Well-to-Well Temperature Uniformity | ±0.1°C |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | AriaMx PCR |
| Instrument Type | Real-Time Quantitative PCR System |
| Thermal Uniformity | ±0.4 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Range | 25.0–99.9 °C |
| Max Ramp Rate | 6 °C/sec |
| Reaction Volume | 10–30 µL |
| Well Format | 96-well |
| Optical Modules | Up to 6 interchangeable filter-based modules |
| Excitation Source | Dye-specific LEDs per module |
| Detection Source | 8-channel photodiode array per module |
| Fluorophores Supported | SYBR Green, EvaGreen, FAM, HEX, ROX, CY3, CY5, ATTO 425 |
| Multiplex Capacity | Up to 5 targets per well |
| Data Acquisition Time | <3 sec per cycle |
| Onboard Storage | 5 GB |
| Touchscreen Interface | Yes |
| Remote Monitoring | Yes |
| Software Included | ARIA Software with LIMS connectivity, melt curve analysis, and FDA 21 CFR Part 11–compliant audit trail options |
| Self-Installable Optics | Yes |
| Dimensions (W×D×H) | 50.0 × 46.0 × 42.0 cm (19.7 × 18.1 × 16.5 in) |
| Warranty | 1 year standard |
| Regulatory Status | For Research Use Only (RUO) |
| Brand | Ahram |
|---|---|
| Origin | South Korea |
| Model | S1 / S1e |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 24-well |
| Heating Mechanism | Tri-zone semiconductor thermal blocks with micro-tube angular oscillation |
| Cycle Time | ≤10 min for 30 cycles |
| Power Options | Rechargeable Li-ion battery (≥4 h continuous operation) or AC adapter |
| Dimensions (W×D×H) | 19.5 × 17.7 × 17.9 cm |
| Weight | 3.0 kg (3.8 kg with battery) |
| Detection Channels | 3 / 5 / 6 multiplex fluorescent channels |
| Connectivity | LAN, Wi-Fi, Bluetooth, USB, optional GPS |
| Control Interface | Integrated capacitive touchscreen OS |
| Compliance | Designed to support GLP/GMP-aligned workflows |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Ecos-Gene Automated Nucleic Acid Detection and Analysis System |
| Sample Throughput | 1/2/4 samples per unit (scalable to 16) |
| Fluorescence Channels | 4 (470–510 nm, 530–565 nm, 585–620 nm, 630–665 nm) |
| Thermal Block Temperature Range | Ambient to 120 °C |
| Temperature Accuracy | ±0.2 °C |
| PCR Ramp Rates | ≥6 °C/s (avg. heating), ≥8 °C/s (max. heating), ≥4.5 °C/s (avg. cooling), ≥8 °C/s (max. cooling) |
| Extraction CV | ≤5% |
| Sample Input Volume | Up to 3 mL (working volume ~2.5 mL) |
| Software Platform | Windows-based, LIS- and cloud-database–compatible |
| Compliance | Designed for CLIA-waived and IVD-use environments |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Emos-Gene 600 / Emos-Gene 600A |
| Sample Capacity | 3 × 32-well (0.2 mL for 600 |
| Detection Channels | 6 independent optical channels (C1–C6) |
| Excitation Source | High-power white LED array |
| Detection Sensor | High-sensitivity CMOS imaging system with precision filter wheel |
| Temperature Range | 4 °C to 99.9 °C |
| Temperature Uniformity | ±0.2 °C @ 95 °C |
| Temperature Accuracy | ±0.15 °C |
| Ramp Rate | 4 °C/s (both heating and cooling) |
| Thermal Lid | Auto-adjustable pressure, 30–110 °C |
| Gradient Capability | Single-module gradient control |
| Display | 13.3-inch capacitive touchscreen |
| OS | Windows 10 or later |
| Power Input | 100–240 V~, 50 Hz, 1400 VA |
| Dimensions (D×W×H) | 504 × 360 × 410 mm |
| Weight | 35 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Esan-Gene 696 / Esan-Gene 696A |
| Sample Format | 696 — 0.2 mL tubes & 96-well plates |
| Reaction Volume | 10–100 µL |
| Optical Channels | 6 (F1: FAM/SYBR Green I |
| F2 | HEX/JOE/VIC |
| F3 | ROX/Texas Red |
| F4 | Cy5/Quasar-670 |
| F5 | Cy5.5 |
| F6 | user-definable, default FRET) |
| Dynamic Range | 10⁰–10¹⁰ copies/µL |
| LOD | 1 copy |
| Ct Reproducibility | CV ≤ 1% |
| Temperature Range | 4–99.9 °C |
| Heating Rate | 3.5 °C/s (avg) |
| Cooling Rate | 2.5 °C/s (avg) |
| Block Uniformity | ±0.2 °C @ 95 °C |
| Temperature Accuracy | ±0.15 °C |
| Temperature Precision | 0.1 °C |
| Melting Resolution | 0.1 °C |
| Gradient Range | 1–40 °C across 6 zones |
| Heat Lid Temp | 30–110 °C |
| Display | 10.1″ LVDS capacitive touchscreen |
| Interfaces | USB-A ×3, LAN ×1 |
| Data Export | Excel, PDF |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Analytik Jena / biometra |
|---|---|
| Origin | Germany |
| Model | qTOWER³ auto 84 |
| Instrument Type | Gradient Real-Time PCR System |
| Sample Capacity | 384-well |
| Heating Rate | 3.7 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Dimensions (W × D × H) | 310 × 365 × 479 mm |
| Block Material | Anodized Aluminum Alloy |
| Recommended Sample Volume | 2–30 µL |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH |
| Product Category | Imported Instrument |
| Model | Biometra TAdvanced 384G |
| Throughput | 384-well format |
| Heating Rate | 4 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Fast PCR Cycler |
| Sample Capacity | 96-well (0.2 mL tubes, 96-well plates, or 12×8 strip tubes) |
| Max Heating Rate | 6.0 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Uniformity | ±0.2 °C |
| Gradient Span | 0.1–30.0 °C (linear, per column) |
| Gradient Range | 20–99 °C |
| Block Temp Range | 3–99 °C |
| Lid Temp Range | 30–110 °C |
| Display | 7″ capacitive color touchscreen |
| Noise Level | ≤45 dB(A) |
| Power Consumption | 850 W |
| Dimensions (W×H×D) | 277 × 264 × 457 mm |
| Weight | 15 kg |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH |
| Product Type | Fast PCR Thermal Cycler |
| Model | Biometra TAdvanced 96 SG |
| Sample Capacity | 96-well format (standard 96-well plates, 0.2 mL tubes, or 8-tube strips) |
| Max Heating Rate | 8 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Uniformity | ±0.15 °C |
| Gradient Span | up to 40 °C across 12 columns |
| Gradient Modes | Linear and Random |
| Block Material | Gold-plated pure silver thermal block |
| Heat Lid | High-Performance Smart Lid (HPSL), pressure-regulated, max lid temperature 110 °C |
| User Management | Three-tier Advanced User Management (AUM) with password protection |
| Software Interface | Dual-view program editor (tabular & graphical), intelligent protocol builder, preloaded templates |
| Compliance Features | Built-in self-diagnostic suite with audit-trail-capable log storage, GLP-compliant operation |
| Operating Noise | ≤45 dB(A) |
| Cooling Method | Bottom-intake / rear-exhaust airflow design |
| Touchscreen | Full-color capacitive touchscreen, glove-compatible |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Biometra TAdvanced 96SG |
| Pricing | Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Gradient PCR Instrument |
| Model | Biometra TAdvanced Twin 48G |
| Sample Capacity | 48 × 2 wells (dual independent blocks) |
| Heating Rate | 5.2 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Inter-well Temperature Uniformity | ±0.2 °C |
| Gradient Range | Linear gradient across 8 rows (LGT) |
| Thermal Sensor | PT100 (Swiss-made, 25-year heritage) |
| Noise Level | ≤45 dB(A) |
| Lid Pressure Control | High-Performance Smart Lid (HPSL) with clutch-based constant-force mechanism |
| User Management | Three-tier Advanced User Management (AUM) with password protection and role-specific permissions |
| Software Features | Intelligent Protocol Assistant (IPA), built-in self-diagnostic suite (thermal ramping, lid function, gradient validation), glove-compatible capacitive touchscreen display |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH |
| Product Type | Gradient PCR Instrument |
| Sample Capacity | 96-well format |
| Heating Rate | 4 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.2 °C |
| Gradient Configuration | 12-column linear or randomized gradient profiles |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Imported Instrument |
| Model | Biometra TRIO 48 |
| Sample Throughput | 144 wells (3 × 48-well blocks) |
| Heating Rate | 5 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Block Uniformity | ±0.2 °C across block |
| Display | 7-inch full-color capacitive touchscreen |
| Power Recovery | Auto-resume after power interruption |
| Tube Compatibility | Standard 0.2 mL tubes and 8-tube strips |
| Cooling Method | Passive air cooling with bottom intake / rear exhaust airflow |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Biometra TRobot II |
| Instrument Type | Fast-cycle PCR System |
| Sample Throughput | 96-well or 384-well format |
| Heating Rate | 5 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.5 °C |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Imported |
| Model | qTOWER 2.2 |
| Price | Upon Request |
| Optical Channels | 6 simultaneous detection channels |
| Excitation Sources | 3 high-intensity LEDs (blue, red, white) |
| Detection Technology | Channel-type photomultiplier tube (CPM) |
| Filter Configurations | 10 interchangeable Ex/Em filter sets |
| Sensitivity | 1 nM FAM in 30 µL reaction volume |
| Sample Capacity | 96-well format |
| Max Ramp Rates | 5.5 °C/s (heating), 4.0 °C/s (cooling) |
| Temperature Uniformity | ±0.2 °C at 95 °C |
| Temperature Accuracy | ±0.1 °C |
| Gradient Range | Up to 40 °C |
| Thermal Lid | 110 °C with SPS (Sample Protection System) and auto-adjusting pressure (up to 10 kg/plate) |
| Software | qPCRsoft v4.x for absolute/relative quantification, ΔΔCt, allelic discrimination, PCR efficiency analysis, and FRET applications |
| Interface | USB 2.0 |
| Dimensions (W×H×D) | 275 × 585 × 275 mm |
| Weight | ~25 kg |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | qTOWER3 G IVD |
| Pricing | Available Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | qTOWER3 G touch |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Capacity | 96-well format |
| Maximum Heating Rate | 8 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.10 °C |
| Excitation Source | Four solid-state RGBW LEDs (blue, green, red, white) |
| Detection System | 8-channel fiber-optic scanning with channel-type photomultiplier tube (PMT) |
| Detection Channels | Configurable 1–6 channels |
| Thermal Gradient | 12-column linear gradient (spanning up to 40 °C) |
| Sample Block Material | Gold-plated pure silver block |
| Lid System | Motorized, pressure-regulated heated lid with auto-height adjustment |
| Software | qPCRsoft v5.x compliant with MIQE guidelines, supporting absolute quantification, relative quantification (ΔΔCt & dual standard curve), melting curve analysis, SNP/allelic discrimination, endpoint analysis, amplification efficiency calculation, and audit-trail-enabled reporting per FDA 21 CFR Part 11 requirements |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Capacity | 96-well format |
| Maximum Heating Rate | 8 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C |
| Excitation Source | 7 high-intensity solid-state LEDs (UV–NIR spectrum) |
| Detection Technology | 8-channel fiber-optic scanning with PMT detector |
| Detection Channels | Configurable 1–6 channels, including dedicated UV and protein-melting filter sets |
| Linear Temperature Gradient | 12-column gradient (spanning up to 40 °C) |
| Thermal Block Material | Gold-plated pure silver |
| Software | qPCRsoft v5.x (MIQE-compliant reporting, audit trail, CFR Part 11-ready configuration options) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | qTOWERiris |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Capacity | 96-well format |
| Heating Rate | 8 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C |
| Brand | analytikjena |
|---|---|
| Origin | Germany |
| Manufacturer | analytikjena GmbH & Co. KG |
| Model | qTOWER 2.0 |
| Optical Channels | Up to 6 (configurable 1–6) |
| Excitation/Emission Filter Sets | 10 interchangeable Ex/Em combinations including FRET-mismatched pairs |
| Light Source | Triple high-efficiency LEDs (blue, red, white) |
| Detector | Channel-type photomultiplier tube (CPM) |
| Scanning Method | 8-channel fiber-optic scanning |
| Temperature Uniformity | < ±0.15 °C at 55 °C |
| Temperature Accuracy | ±0.1 °C at 72 °C |
| Max Heating Rate | 5.5 °C/s (adjustable 0.1–5.5 °C/s) |
| Max Cooling Rate | 4.0 °C/s (adjustable 0.1–4.0 °C/s) |
| Sample Capacity | 96-well plate, 0.2 mL tubes or 8-tube strips |
| Reaction Volume | 10–60 µL |
| Thermal Block | Gold-plated pure silver Peltier module |
| Hot Lid | 110 °C max, auto-pressure regulation up to 10 kg/plate |
| Detection Sensitivity | Single-copy DNA detection |
| Software | qPCRsoft v4.x with absolute quantification, melt curve analysis, relative quantification (ΔΔCt), allelic discrimination (SNP), expression ratio analysis, and GLP-compliant audit trail |
| Compliance | Designed for ISO/IEC 17025, CLIA, and FDA 21 CFR Part 11 environments (audit trail, electronic signature, user access control) |
| Brand | analytikjena |
|---|---|
| Origin | Germany |
| Model | qTOWER3 84G |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Capacity | 384-well format |
| Maximum Heating Rate | 4 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C |
| Optical Configuration | 6-channel excitation/emission system (configurable 1–6 channels) |
| Light Source | RGBW high-intensity long-life LEDs (blue, green, red, white) |
| Detector | High-sensitivity channel-type photomultiplier tube (PMT) |
| Detection Method | 16-channel fiber-optic scanning |
| Sensitivity | Single-copy DNA detection |
| Dynamic Range | 10 orders of magnitude |
| Recommended Reaction Volume | 2–30 µL |
| Linear Temperature Gradient | 24-column gradient |
| Thermal Module | Peltier-based with corrosion-resistant surface |
| Hot Lid Temperature | Up to 110 °C with auto-adjusting pressure (up to 30 kg/plate) |
| Noise Level | ≤45 dB(A) |
| Software | MIQE-compliant analysis suite with unlimited installation and lifetime free updates |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | analytikjena |
|---|---|
| Origin | Germany |
| Manufacturer | analytikjena GmbH & Co. KG |
| Type | Real-Time Fluorescence Quantitative PCR Instrument |
| Sample Capacity | 96-well format |
| Heating Rate | 8 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C |
| Optical Channels | 4–6 configurable |
| Excitation/Detection Filter Sets | 12 interchangeable combinations (including FRET-mismatched and protein melting-specific configurations) |
| Light Source | RGBW high-intensity LEDs (blue, green, red, white) |
| Detector | High-sensitivity photomultiplier tube (PMT) |
| Detection Method | 8-channel fiber-optic scanning system |
| Dynamic Range | 10 orders of magnitude |
| Sample Volume Range | 5–100 µL |
| Sample Block Material | Gold-plated pure silver thermal block |
| Lid Temperature Range | 30–110 °C with auto-adjusting contact pressure (up to 30 kg/plate) |
| Software | Free lifetime-upgradable qPCR analysis suite supporting absolute quantification, dual-standard-curve relative quantification, ΔΔCt with amplification efficiency correction, melting curve analysis, allelic discrimination/SNP genotyping, endpoint analysis, and efficiency calculation |
| Acoustic Noise Level | ≤45 dB(A) |
| Compliance | Designed and manufactured in accordance with ISO 13485, CE-IVD (where applicable), and GLP/GMP-aligned documentation practices |
| Brand | analytikjena |
|---|---|
| Origin | Germany |
| Model | qTOWER3 G IVD |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Capacity | 96-well format |
| Heating Rate | 8 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C |
| Thermal Gradient | 12-column linear gradient |
| Excitation Sources | Four solid-state RGBW LEDs (blue, green, red, white) |
| Detection System | Channel-type Photomultiplier Tube (CPMT) |
| Software Interface | Bilingual (English & Chinese) |
| Regulatory Designation | IVD-certified per EU IVDR (Regulation (EU) 2017/746) |
| Brand | analytikjena |
|---|---|
| Origin | Shanghai, China |
| Model | qTOWER3 G |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Capacity | 96-well format |
| Max Heating Rate | 8 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Inter-Well Temperature Uniformity | ±0.15 °C |
| Cooling Rate | 6 °C/s |
| Gradient Range | 1–40 °C (linear or random mode, 12-column configuration) |
| Optical Channels | Up to 6 independently configurable fluorescence detection channels |
| Excitation/Detection Filter Sets | 12 interchangeable combinations including FRET-mismatched and protein melting-optimized sets |
| Light Source | RGBW high-intensity long-life LEDs (blue, green, red, white) |
| Detector | High-sensitivity channel-type photomultiplier tube (PMT) |
| Detection Method | 8-channel fiber-optic scanning (8 wells simultaneously) |
| Sensitivity | Single-copy DNA detection capability |
| Dynamic Range | 10 logs |
| Recommended Reaction Volume | 10–80 µL |
| Thermal Block | Gold-plated pure silver Peltier module |
| Software | MIQE-compliant analysis suite with unlimited free installation and lifetime updates |
| Noise Level | ≤45 dB(A) |
| Connectivity | USB, RS232, Ethernet |
| Dimensions (W×H×D) | 275 × 585 × 275 mm |
| Weight | ~30 kg |
| Brand | analytikjena |
|---|---|
| Origin | Germany |
| Manufacturer | analytikjena GmbH |
| Type | Real-Time Fluorescence Quantitative PCR Instrument |
| Sample Capacity | 384-well |
| Heating Rate | 4 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C |
| Optical Channels | Up to 6 independent excitation/emission channels |
| Light Source | 7 high-intensity, long-life LEDs (UV–NIR spectrum) |
| Detector | High-sensitivity photomultiplier tube (PMT) |
| Scanning Method | 16-channel fiber-optic simultaneous detection |
| Detection Sensitivity | Single-copy DNA template resolution |
| Dynamic Range | 10 logs |
| Gradient Function | 24-column linear temperature gradient |
| Thermal Block | Peltier-based, corrosion-resistant |
| Lid Temperature | Up to 110 °C with auto-adjusting pressure (max. 30 kg/plate) |
| Software | qPCR analysis suite compliant with MIQE guidelines |
| Connectivity | USB, LIMS-compatible |
| Noise Level | ≤60 dB(A) |
| Brand | analytikjena |
|---|---|
| Origin | Germany |
| Manufacturer | analytikjena GmbH |
| Type | Real-Time Fluorescence Quantitative PCR Instrument |
| Sample Capacity | 384-well format |
| Heating Rate | 4 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C |
| Optical Channels | 4–6 configurable |
| Excitation/Detection Filter Sets | 12 interchangeable combinations including FRET-mismatched and protein melting-specific configurations |
| Light Source | RGBW high-intensity LEDs (blue, green, red, white) |
| Detector | High-sensitivity photomultiplier tube (PMT) |
| Detection Method | 16-channel fiber-optic scanning system |
| Dynamic Range | 10 orders of magnitude |
| Reaction Volume | 2–30 µL |
| Heat Lid Temperature Range | 30–110 °C with auto-adjusting contact pressure up to 30 kg/plate |
| Software | Free lifetime-upgradable analysis suite supporting absolute quantification, dual-standard-curve relative quantification, ddCt with amplification efficiency correction, melting curve analysis, SNP/allele discrimination, endpoint analysis, and efficiency calculation |
| Acoustic Noise Level | ≤45 dB(A) |
| Brand | analytikjena |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | qTOWER384G |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 384-well format |
| Maximum Heating Rate | 4 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C |
| Optical Configuration | 6-channel excitation/emission system (field-upgradable from 1–6 channels) |
| Filter Sets | 12 interchangeable excitation/emission filter combinations, including FRET-optimized and protein melting-specific configurations |
| Light Source | RGBW solid-state LEDs (blue, green, red, white) with uniform spectral intensity, zero thermal emission, >50,000 h lifetime |
| Detector | High-sensitivity channel-type photomultiplier tube (PMT) |
| Detection Method | 16-channel fiber-optic scanning (16 wells simultaneously), ROX-free operation with optional passive reference correction |
| Sensitivity | Single-copy DNA detection |
| Dynamic Range | 10 logs (10¹–10¹¹ copies) |
| Recommended Reaction Volume | 2–30 µL |
| Thermal Gradient | 24-column linear temperature gradient (enables precise annealing optimization) |
| Thermal Block | Peltier-based, corrosion-resistant, high-thermal-conductivity alloy |
| Heat Lid | 110 °C maximum, auto-adjusting pressure (up to 30 kg/plate), height compensation |
| Software | qPCRsoft — quantitative analysis, dual standard curve, ΔΔCt with amplification efficiency modeling, melting curve analysis, SNP/allelic discrimination, endpoint genotyping, efficiency calculation, MIQE-compliant reporting, LIMS integration (via USB), GLP/GMP-ready audit trail (optional configuration), unlimited installations, lifetime free updates |
| Acoustic Noise Level | ≤45 dB(A) |
| Compliance | Designed and validated per ISO 13485 principles |