Polymerase Chain Reaction Instrument
Filter
Showing 61–90 of 194 results
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | ProFlex |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 32-well, 96-well, dual 96-well, dual 384-well, and 24 × 20k Digital PCR Chip modules |
| Ramp Rate | Up to 6.0 °C/s (user-adjustable) |
| Temperature Accuracy | ±0.25 °C (35–99.9 °C) |
| Well-to-Well Uniformity | < 0.5 °C (measured 20 s after reaching 95 °C) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | ProFlex™ 2 x 96-well PCR System |
| Heating Rate | 3.0°C/s |
| Temperature Accuracy | ±0.25°C (35–99.9°C) |
| Well-to-Well Temperature Uniformity | <0.5°C (20 seconds after reaching 95°C) |
| Sample Capacity | 2 × 96-well plates |
| Instrument Type | Conventional Thermal Cycler |
| Compatible Module Options | Dual 96-well, Triple 32-well, Dual Flat Block, 96-well Fast, and Digital PCR Chip Block (for QuantStudio™ 3D) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Manufactured in China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Model | QuantStudio 1 Plus |
| Sample Capacity | 96-well format |
| Maximum Heating Rate | 3.5 °C/sec |
| Average Heating Rate | 1.8 °C/sec |
| Temperature Accuracy | ±0.25 °C |
| Well-to-Well Temperature Uniformity | ±0.4 °C |
| Dye Calibration | Factory-calibrated for FAM, VIC, ROX, and Cy5 fluorophores |
| Dynamic Range | 10 logs |
| Detection Sensitivity | Single-copy DNA detection |
| Concentration Discrimination | Capable of resolving 1.5-fold differences in target concentration |
| Run Time (Fast Mode) | ≤40 minutes for 40-cycle amplification |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | QuantStudio 7 Pro |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 96-well format |
| Maximum Heating Rate | 6.5°C/s |
| Average Heating Rate | 3.66°C/s |
| Temperature Accuracy | ±0.25°C |
| Well-to-Well Temperature Uniformity | ±0.4°C |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Digital PCR Instrument |
| Model | QuantStudio Absolute Q |
| Sample Throughput | Up to 16 samples per run on a single MAP16 microfluidic array plate (configurable in multiples of 4: 4, 8, 12, or 16) |
| Fluorescence Channels | 5-color detection (factory-calibrated) |
| Detection Principle | Nanowell-based digital PCR using fixed-volume microfabricated wells |
| Effective Partitioning Efficiency | >95% active reaction partitions |
| Dead Volume | <5% |
| Integrated Workflow | Fully automated droplet generation, thermal cycling, fluorescence imaging, and data analysis |
| Run Time | ~90 minutes from sample loading to final quantification report |
| Software Compliance | Supports audit trail, user access control, and electronic signature per FDA 21 CFR Part 11 requirements |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Instrument Type | Gradient PCR System |
| Sample Capacity | 96-well format |
| Heating Rate | 4°C/sec |
| Temperature Accuracy | ±0.25°C (35–99.9°C) |
| Well-to-Well Temperature Uniformity | <0.5°C (measured 30 sec after reaching 95°C) |
| Thermal Control Architecture | VeriFlex™ 3-Zone Independent Peltier Module |
| Interface | Capacitive Touchscreen, USB 2.0, Wi-Fi 802.11 b/g/n |
| Software Compatibility | Thermo Fisher Connect Cloud Platform, compatible with standard .pcr file import/export |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Veriti |
| Instrument Type | Standard Thermal Cycler |
| Sample Capacity | 96-well, 384-well, 60-well, and Fast 86-well formats |
| Ramp Rate | 5.00 °C/sec |
| Temperature Accuracy | ±0.25 °C (35–99 °C) |
| Well-to-Well Uniformity | <0.5 °C (measured 20 sec after reaching 95 °C) |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | VeritiPro |
| Instrument Type | Gradient PCR System |
| Sample Capacity | 96-well (0.2 mL) and 384-well (0.02 mL) blocks |
| Heating Rate | 6.0°C/s |
| Temperature Accuracy | ±0.25°C (35–99.9°C) |
| Well-to-Well Temperature Uniformity | <0.25°C (at 95°C, measured 30 s after target reached) |
| VeriFlex™ Block | 6 independently controlled thermal zones |
| Thermal Lid | 30–110°C, pressure-adjustable, auto-lift |
| Operating Voltage | 100–240 V, 50–60 Hz |
| Power Consumption | ≤700 W |
| Dimensions (H×W×D) | 21.7 × 24.5 × 46.5 cm |
| Weight | 12.0 kg |
| Environmental Requirements | 15–30°C, 15–80% RH (non-condensing) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Model | 2720 |
| Instrument Type | Standard PCR Thermal Cycler |
| Sample Capacity | 96-well format |
| Ramp Rate | 2.7 °C/s |
| Temperature Accuracy | ±0.25 °C |
| Well-to-Well Uniformity | ±0.5 °C (measured 30 s after reaching 95 °C) |
| Dimensions | Compact benchtop design |
| User Interface | Graphical LCD with intuitive navigation |
| Brand | KHB |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Model | Aurora7500 |
| Sample Throughput | 96-well format |
| Temperature Accuracy | ±0.2 °C |
| Brand | Autobio |
|---|---|
| Model | AutoMolec 3000 |
| Origin | Henan, China |
| Sample Throughput | 3000 tests/day |
| Heating Rate | 4 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.5 °C |
| Detection Limit | <100 copies/mL |
| Cycle Time per Sample | ~100 min |
| Compliance | ISO 13485, CE-IVD, NMPA Registration No. 20223400123 |
| Brand | Azure Biosystems |
|---|---|
| Origin | USA |
| Model | Cielo 6 / Cielo 3 |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 96-well format |
| Max Heating Rate | 6°C/s |
| Temperature Accuracy | ±0.1°C |
| Well-to-Well Temperature Uniformity | ±0.2°C |
| Excitation Source | High-Power LED (450–730 nm for Cielo 6 |
| Detection Channels | 6 (Cielo 6) / 3 (Cielo 3) |
| Multiplexing Capacity | Up to 6 targets (Cielo 6) / up to 3 targets (Cielo 3) |
| Reaction Volume | 1–150 µL (10–65 µL recommended) |
| Dynamic Range | 10 logs |
| Onboard Memory | 32 GB (~20,000 experiments) |
| Connectivity | USB, Wi-Fi, Ethernet |
| Footprint | 30.5 × 50.8 × 43.2 cm (W × D × H) |
| Brand | BIO-DL |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Life ECO |
| Instrument Type | Standard Thermal Cycler |
| Sample Capacity | 96-well format (0.2 mL tubes or plates) |
| Max. Heating Rate | ≥4 °C/s |
| Temperature Accuracy | ≤±0.1 °C at 55 °C |
| Well-to-Well Temperature Uniformity | ≤±0.3 °C |
| Cooling Rate | ≥4 °C/s |
| Temperature Range | 4–105 °C |
| Thermal Control Modes | Block Mode & Simulated Tube Mode |
| Gradient Range | 1–30 °C |
| Heat Lid Temperature | Adjustable from 30–110 °C with pressure regulation |
| Display | 5.7-inch color touchscreen |
| Onboard Memory | 250 protocols |
| Interface | USB port for firmware/software updates and data export |
| Power Failure Recovery | Yes |
| Soak Function | Yes |
| Certifications | Ferrotec Peltier thermoelectric modules |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | C1000 Touch™ 384-Well |
| Instrument Type | Gradient Thermal Cycler |
| Sample Capacity | 384-well plate |
| Max Heating Rate | 2.5 °C/s |
| Temperature Accuracy | ±0.2 °C at 90 °C |
| Well-to-Well Temperature Uniformity | ±0.4 °C within 10 s at 90 °C |
| Temperature Gradient Range | 1–24 °C across 12 columns |
| Gradient Accuracy | ±0.2 °C (last column) |
| Operating Temperature Range | 0–100 °C |
| Input Power | 850 W max |
| Display | 8.5-inch color LCD touchscreen |
| Onboard Memory | >1,000 protocols |
| Dimensions (W×D×H) | 33 × 45.7 × 20.3 cm |
| Weight | 10.4 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | C1000 Touch™ 96 Deep Well |
| Instrument Type | Gradient PCR System |
| Sample Capacity | 1–96 wells (0.2 mL tubes or 96-well plates) |
| Max Heating Rate | 2.5°C/s |
| Temperature Accuracy | ±0.2°C at 90°C |
| Well-to-Well Temperature Uniformity | ±0.4°C within 10 s at 90°C |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96 × 0.2 mL tubes or 1 × 96-well plate |
| Max Heating/Cooling Rate | 5°C/sec |
| Temperature Accuracy | ±0.2°C at 90°C |
| Well-to-Well Temperature Uniformity | ±0.4°C within 10 sec at 90°C |
| Temperature Gradient Range | 30–100°C |
| Gradient Accuracy (last column) | ±0.2°C |
| Column-wise Uniformity | ±0.4°C within 10 sec at 90°C |
| Input Power | 850 W max |
| Display | 8.5" color LCD touchscreen |
| Onboard Memory | >1,000 protocols |
| Dimensions (W×D×H) | 33 × 45.7 × 20.3 cm |
| Weight | 10.4 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | C1000 Touch™ Dual 48 |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 2 × 48 × 0.2 mL tubes or 2 × 48-well plates |
| Max Heating Rate | 4°C/s |
| Temperature Accuracy | ±0.2°C at 90°C |
| Well-to-Well Temperature Uniformity | ±0.4°C within 10 s at 90°C |
| Temperature Gradient Range | 1–24°C (30–100°C) |
| Gradient Accuracy | ±0.2°C (last column) |
| Gradient Uniformity per Column | ±0.4°C within 10 s |
| Input Power | 850 W max |
| Dimensions (W×D×H) | 33 × 45.7 × 20.3 cm |
| Weight | 10.4 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | CFX Connect |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well (0.2 mL tubes) |
| Maximum Heating Rate | 5 °C/s (adjustable from 0.1 to 5 °C/s) |
| Temperature Accuracy | ±0.2 °C at 90 °C setpoint |
| Well-to-Well Temperature Uniformity | ±0.4 °C within 10 seconds after reaching 90 °C |
| Excitation Sources | 3 LEDs (450–535 nm) |
| Emission Detection Range | 3 Photodiodes (515–580 nm) |
| Gradient PCR | Yes, range 30–100 °C, max ΔT = 24 °C |
| High-Resolution Melting (HRM) Support | Yes |
| Connectivity | USB |
| Dimensions (W×D×H) | 33 × 45.7 × 35.6 cm |
| Weight | 21 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | CFX Duet |
| Detection Channels | 2 + FRET |
| Temperature Uniformity | ±0.3°C across 96-well block |
| Gradient Range | Up to 24°C |
| Software | CFX Maestro (including FDA 21 CFR Part 11-compliant Security Edition) |
| Included License | qbase+ Advanced Analysis Module |
| Optical System | Solid-State Scanning Optical Shuttle |
| Calibration | Factory-calibrated for common dyes (FAM, HEX, VIC, ROX, Cy5, etc.) |
| Compatibility | Full compatibility with Bio-Rad PrimePCR Assays and SsoAdvanced Supermixes |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | CFX Opus 384 |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 384-well format |
| Heating Rate | 2.5 °C/sec |
| Temperature Accuracy | ±0.2 °C |
| Well-to-Well Temperature Uniformity | ±0.3 °C |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | CFX Opus 96 |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 96-well format |
| Heating Rate | 5°C/sec |
| Temperature Accuracy | ±0.2°C |
| Well-to-Well Temperature Uniformity | ±0.3°C |
| Optical Configuration | Individual well excitation and detection with FRET-capable channels |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | CFX Opus Deepwell |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Capacity | 96-well format |
| Heating Rate | 2.5°C/sec |
| Temperature Accuracy | ±0.2°C |
| Well-to-Well Temperature Uniformity | ±0.4°C |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | CFX384 Touch |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 384-well format |
| Maximum Heating Rate | 2.5 °C/s (adjustable from 0.1 to 2.5 °C/s) |
| Temperature Accuracy | ±0.2 °C at 90 °C setpoint |
| Well-to-Well Temperature Uniformity | ±0.4 °C within 10 seconds after reaching 90 °C |
| Excitation Range | 5 LEDs (400–650 nm) |
| Emission Detection Range | 5 Photodiodes (515–690 nm) |
| Supported Applications | Absolute Quantification, Gene Expression Analysis, SNP Genotyping, HRM (High-Resolution Melting), Multiplex Detection (up to 4 targets per well) |
| Software | CFX Maestro Secure Edition (21 CFR Part 11 compliant, audit trail, user access control) |
| Thermal Block | Integrated C1000 Touch thermal cycler engine |
| Gradient PCR | Yes, 30–100 °C range, max ΔT = 24 °C |
| Dimensions (W × D × H) | 33 × 45.7 × 35.6 cm |
| Weight | 21 kg (47 lb) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | CFX96 Touch |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well (0.2 mL tubes) |
| Max Heating Rate | 5 °C/s (adjustable from 0.1 to 5 °C/s) |
| Temperature Accuracy | ±0.2 °C at 90 °C setpoint |
| Well-to-Well Temperature Uniformity | ±0.4 °C within 10 seconds after reaching 90 °C |
| Excitation Range | 6 LEDs (450–684 nm) |
| Emission Detection Range | 6 Photodiodes (515–730 nm) |
| Gradient PCR | Yes, 30–100 °C, max ΔT = 24 °C |
| High-Resolution Melting (HRM) Support | Yes |
| Interface | USB |
| Dimensions (W×D×H) | 33 × 45.7 × 35.6 cm |
| Weight | 21 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CFX96 Touch |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well |
| Heating Rate | 3.3°C/sec |
| Temperature Accuracy | ±0.2°C |
| Well-to-Well Temperature Uniformity | ±0.4°C |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PTC Tempo |
| Instrument Type | Standard Thermal Cycler |
| Sample Capacity | 96-well, 384-well, 48/48 dual-block |
| Heating Rate | 5°C/s |
| Temperature Accuracy | ±0.2°C (measured at 90°C) |
| Well-to-Well Temperature Uniformity | ±0.4°C (measured at 90°C) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | QX Continuum™ |
| Instrument Type | Digital PCR System |
| Sample Throughput | 96-well format |
| Certified Performance | NMI-traceable reference material validation |
| Droplet Generation | >20,000 droplets per 16 µL sample |
| Multiplexing Capacity | Up to 4 targets per well |
| Thermal Zones | Up to 8 independent temperature zones per plate |
| Software | QX Insight Analysis Software |
| Regulatory Status | For Research Use Only (RUO), not for clinical diagnostic use |
| Compliance | Designed to support GLP/GMP-aligned data integrity practices |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | QX ONE |
| Instrument Type | Digital PCR System |
| Sample Throughput | 32–480 wells per run |
| Heating Rate | 2.5 °C/s |
| Temperature Accuracy | ±0.2 °C (at 90 °C) |
| Well-to-Well Temperature Uniformity | ±0.4 °C (at 90 °C) |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | QX200 |
| Instrument Type | Digital PCR System |
| Sample Throughput | 96-well format |
| Heating Rate | 0.1–5.0°C/s (typical setting: 2.0°C/s) |
| Temperature Accuracy | ±0.2°C (at 90°C) |
| Well-to-Well Temperature Uniformity | ±0.4°C (at 90°C) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Instrument Type | Digital PCR System |
| Model | QX600 |
| Detection Channels | 6-color (FAM, HEX, Cy5, Cy5.5, ROX, ATTO 590) |
| Multiplex Capacity | up to 12-plex per well (CNV applications) |
| Limit of Detection | <0.1% mutant allele frequency |
| Quantification Precision | ±10% CV |
| Regulatory Compliance | FDA 21 CFR Part 11 (Advanced Software), GLP/GMP-ready audit trail |
| Platform Compatibility | Fully compatible with Manual DG and AutoDG droplet generators |
| Assay Support | TaqMan probe-based and EvaGreen dye-based ddPCR assays |
| Certification | Traceable calibration verified by Australia’s National Measurement Institute (NMI) |