Preparative Liquid Chromatography
Filter
Showing 1–30 of 94 results
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | puriFlash 5.015-XL |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | Medium-Low Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 0–825 mL/min |
| Maximum Operating Pressure | 15 bar |
| UV Detection Wavelength Range | 200–800 nm |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | puriFlash 5.020 |
| Application Level | Laboratory Grade |
| Instrument Type | Medium- to Low-Pressure Preparative LC |
| Flow Rate Range | 0–300 mL/min |
| Maximum Operating Pressure | 20 bar |
| UV Wavelength Range | 200–800 nm (with optional extended UV pack) |
| Data Acquisition Rate | 1 Hz (not amu — corrected per instrument context) |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | puriFlash 5.050 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-Low Pressure Preparative LC |
| Flow Rate Range | 0–250 mL/min |
| Maximum Operating Pressure | 50 bar |
| UV Detection Wavelength Range | 200–800 nm |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | puriFlash 5.250 |
| Instrument Type | High-Pressure Preparative LC System |
| Flow Rate Range | 0.1–250 mL/min |
| Maximum Operating Pressure | 250 bar |
| UV-Vis Wavelength Range | 200–800 nm |
| Application Level | Laboratory-Scale to Pilot-Scale Purification |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | puriFlash 5.250P |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 0.1–125 mL/min |
| Maximum Operating Pressure | 250 bar |
| UV Wavelength Range | 200–800 nm |
| Detection Cell | 1.3 mm pathlength, 55 µL volume |
| Gradient Capability | Quaternary solvent delivery with automated degassing |
| Column Compatibility | Up to 60 mm internal diameter |
| Fraction Collection | 132-position rack (18 × 150 mm tubes, configurable) |
| Control Interface | 15″ HD capacitive touchscreen |
| Software Platform | InterSoft X Genius (KISS-compliant, drag-and-drop gradient editor, method automation, audit-trail-ready) |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | puriFlash 5.400 |
| Flow Rate Range | 0–125 mL/min |
| Maximum Pressure | 400 bar |
| Wavelength Range | 200–800 nm |
| Wavelength Reproducibility | ±0.5 nm |
| Detection Channels | Dual-wavelength (UV-Vis) with full-spectrum acquisition capability |
| Column ID Support | Up to 60 mm |
| Sample Capacity | 132-tube rack (18 × 150 mm), configurable for alternative formats |
| Touchscreen Interface | 15-inch HD capacitive touchscreen |
| Gradient Capability | Quaternary solvent delivery |
| Injection Modes | Liquid injection and dry-load (Load&Go) via 6-port + 10-port valve manifold |
| Flow Cell | 1.0 mm pathlength, 20 µL volume |
| Compliance | Designed for GLP-compliant workflow execution |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | puriFlash 535-XL |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | Medium-Low Pressure Preparative LC |
| Flow Rate Range | 0–400 mL/min |
| Maximum Operating Pressure | 35 bar |
| UV Detection Wavelength Range | 200–800 nm |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | puriFlash XS 520plus |
| Application Level | Laboratory Grade |
| Instrument Type | Medium- to Low-Pressure Preparative LC |
| Flow Rate Range | 0.1–300 mL/min |
| Maximum Operating Pressure | 20 bar |
| Column ID Compatibility | Up to 80 mm |
| Typical Prep Scale | 4–800 g |
| Detector Options | UV/Vis, iELSD, Mass Spectrometry (MS) Interface Capable |
| Software Platform | InterSoft X |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ASTRA |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-Low Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 1–200 mL/min |
| Maximum Operating Pressure | 200 psi |
| UV-Vis Detection | PDA Detector, 200–800 nm |
| Gradient Capability | Quaternary Solvent Selection |
| Column Compatibility | Normal- & Reversed-Phase Columns (4–800 g), Max. Sample Load: 80 g |
| Fraction Collection Modes | Full Collection, Peak-Based Collection, Manual Trigger, Time-Window Collection |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | CHEETAH MP200 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-Low Pressure Preparative HPLC |
| Flow Rate Range | 1–200 mL/min |
| Flow Accuracy | ±2% |
| Flow Precision | ±2% |
| Maximum Operating Pressure | 200 psi |
| Wavelength Range | 200–400 nm (standard detector), 200–800 nm (optional dual-range detector) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±1 nm |
| Baseline Noise | ≤3×10⁻⁴ AU |
| Data Acquisition Rate | 3 Hz |
| Gradient Configuration | Binary or Quaternary |
| Detection Modes | Single-Wavelength, Dual-Wavelength (independent collection & monitoring), Ratio-Based Triggering |
| Fraction Collection | Integrated 2D Fraction Collector with Adjustable Rack Mapping |
| Solvent Compatibility | All Common HPLC-Grade Organic and Aqueous Solvents |
| Safety Features | Real-Time Pressure Monitoring, Leak Detection with Audible/Visual Alert |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | CH-200P |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Maximum Operating Pressure | 200 psi (1.38 MPa) |
| Flow Rate Range | 1–200 mL/min |
| UV Detection Wavelength Range | 200–600 nm |
| Gradient Capability | Binary Gradient |
| Column Compatibility | Flash columns (4–800 g silica/C18), max. sample load: 80 g |
| Collection Modes | Full collection, peak-based collection, manual collection, time-window collection |
| Real-time Fraction Mapping | Color-coded tube assignment per detected peak |
| Purge Function | Integrated air pump module for manual/automated column purging |
| Interface | Touchscreen GUI with transparent fluidic pathway visualization |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | CHEETAH Pro CH-200PII |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-to-Low Pressure Preparative LC System |
| Flow Rate Range | 1–200 mL/min |
| Maximum Operating Pressure | 200 psi (1.38 MPa) |
| UV Detection Wavelength Range | 200–600 nm |
| Gradient Capability | Binary Gradient |
| Column Compatibility | Normal- and Reversed-Phase Flash Columns (4–800 g), Max Sample Load: 80 g |
| Fraction Collection Modes | Full Collection, Peak-Based Collection, Manual Trigger, Time-Window Collection |
| Real-Time Tube Mapping | Color-Coded Fraction Tube Assignment per Peak |
| Optional Air-Purge Module | Integrated Air Pump for Manual/Automatic Flash Column Purging (CH-200PII-Air Variant) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | CH-200PII |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-Low Pressure Preparative LC System |
| Flow Rate Range | 1–200 mL/min |
| Maximum Operating Pressure | 200 psi (1.38 MPa) |
| UV Detection Wavelength Range | 200–600 nm |
| Gradient Capability | Binary Gradient |
| Column Compatibility | Normal-Phase & Reversed-Phase Flash Columns (4–800 g), Max. Sample Load: 80 g |
| Collection Modes | Full Collection, Peak-Based Collection, Manual Collection, Time-Window Collection |
| Real-Time Fraction Mapping | Color-Coded Tube Assignment per Detected Peak |
| Optional Air-Purge Module | Integrated Air Pump for Manual/Automatic Flash Column Purging (CH-200PII-Air Variant) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | MP200 |
| Price Range | USD 14,000–28,000 |
| Application Level | Laboratory-Scale Purification |
| Instrument Type | Medium-Pressure Preparative LC |
| Flow Rate Range | 1–200 mL/min |
| Flow Accuracy | ±2% |
| Flow Precision (RSD) | ≤2% |
| Maximum Operating Pressure | 200 psi |
| Detection Wavelength Range | Not Specified |
| Wavelength Reproducibility | Not Specified |
| Baseline Noise | Not Specified |
| Data Acquisition Frequency | Not Specified |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | FLEXA HP 100 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC System |
| Flow Rate Range | 1–100 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤1% |
| Maximum Pressure | 20–30 MPa |
| Wavelength Range (UV-Vis Detector) | 190–800 nm |
| Wavelength Reproducibility | ±1 nm |
| Baseline Noise (UV-Vis, 254 nm, 1 s) | < ±2.5 × 10⁻⁵ AU |
| Data Acquisition Rate | Up to 20 Hz |
| Detector Options | UV-Vis, ELSD, RI |
| Fraction Collection Modes | Time-based, Peak-triggered, Threshold-based, User-defined Coordinates |
| Communication Interface | RS-232, Optional Ethernet/USB |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | FL-H100G |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0–100 mL/min |
| Flow Accuracy | ±1 % |
| Maximum Operating Pressure | 20 MPa |
| Brand | Agela |
|---|---|
| Model | FL-H1000G |
| Origin | Tianjin, China |
| Instrument Type | High-Pressure Preparative LC System |
| Flow Rate Range | 0–1000 mL/min |
| Flow Accuracy | ±3% |
| Maximum Operating Pressure | 10 MPa |
| Application Level | Laboratory-Scale Purification |
| Configuration | Modular (Pump, UV/Vis Detector, Fraction Collector, Auto-Sampler, Column Switching Valve) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | FL-H300G |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative HPLC System |
| Flow Rate Range | 0.01–300 mL/min |
| Flow Accuracy | ±2% |
| Maximum Operating Pressure | 15 MPa |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | FL-H050G |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative HPLC System |
| Flow Rate Range | 0.1–50 mL/min |
| Flow Accuracy | ±1% RSD |
| Maximum Operating Pressure | 30 MPa |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Region of Origin | Domestic (China) |
| Model | FLEXA |
| Price Range | USD 14,000 – 28,000 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-to-Low Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 1–100 mL/min (FLEXA GP100), 1–200 mL/min (FLEXA GP200), 1–30 L/min (FLEXA GP030) |
| Flow Accuracy | ±2% |
| Flow Precision (RSD) | ±2% |
| Maximum Operating Pressure | 200 psi |
| Wavelength Range | 200–400 nm (FL-UV2040), 200–800 nm (FL-UV2080/2080B) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Reproducibility | ±1 nm |
| Baseline Noise | ≤3 × 10⁻⁴ AU |
| Data Acquisition Rate | 3 Hz |
| Gradient Composition Accuracy | ±1% |
| Gradient Modes | Binary, Linear, Isocratic, and Custom Profiles |
| Detector Channels | Dual-Wavelength Simultaneous Detection |
| UV Source | Deuterium Lamp (200–400 nm), Tungsten Lamp (400–800 nm) |
| Collection Vessels | 13 mm, 15 mm, 18 mm, 25 mm test tubes, and 100 mL Erlenmeyer flasks |
| Fraction Trigger Modes | Full Collection, Manual Trigger, Threshold-Based Peak Detection |
| Communication Interface | RS-232 |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | FLEXA-MH |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 1–200 mL/min |
| Flow Accuracy | ±2% |
| Flow Precision (RSD) | ≤2% |
| Maximum Pressure | 10 MPa |
| Wavelength Range | 200–800 nm (selectable dual-wavelength mode) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75 × 10⁻⁵ AU at 254 nm, TC = 1 s |
| Data Acquisition Rate | Not specified |
| Detection Options | UV-Vis (dual-wavelength), optional ELSD or RI detector |
| Gradient Capability | Binary gradient, supporting linear, isocratic, and custom profiles |
| Column Configuration | Compatible with both reversed-phase and normal-phase chromatography |
| Collection Mode | X/Y-axis programmable fraction collector |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HS-D-5800P |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0–150 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | <1% |
| Maximum Operating Pressure | 40 MPa |
| UV Detection Wavelength Range | 200–800 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HS-D-5800P |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0.01–150 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | <1% |
| Maximum Operating Pressure | 40 MPa |
| UV-Vis Wavelength Range | 200–800 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HS-D-5800P |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0.01–150 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | <1% |
| Maximum Operating Pressure | 40 MPa |
| UV Wavelength Range | 200–800 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HS-2900P II |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 1–100 mL/min |
| Maximum Operating Pressure | 20 MPa |
| UV-Vis Wavelength Range | 200–800 nm |
| Touchscreen Interface | 12-inch Capacitive Display |
| Autosampler Volume Range | 1–20 mL |
| Fraction Collection Modes | Peak-based, Full-run, Manual, Time/UV Window-triggered |
| Compatible Collection Vessels | 15 mm, 18 mm, 25 mm ID tubes and custom containers |
| Pump Configuration | Dual High-Precision Plunger Pumps |
| Gradient Mixing Accuracy | ≤0.5% RSD |
| Column Compatibility | Static HPLC prep columns (10–50 mm ID) |
| Software | Dedicated preparative chromatography control suite with user permission hierarchy and 21 CFR Part 11-compliant audit trail |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | OCTOPUS |
| Application Level | Laboratory-grade |
| Instrument Type | Medium- to Low-Pressure Preparative LC System |
| Flow Rate Range | 1–200 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤2% |
| Maximum Pressure | 20 MPa |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 1 nm |
| Baseline Noise | ±5 × 10⁻⁵ AU |
| Data Acquisition Frequency | Not Specified |
| Gradient Configuration | Binary or Quaternary Pump Options |
| Compatible Detectors | PDA, ELSD, RI |
| Automation Features | Auto-sampler, Column Switcher, Intelligent Fraction Collector with Vial Rack ID Recognition and Solvent/Waste Level Sensing |
| Column Compatibility | Flash cartridges, medium-pressure glass columns, high-pressure stainless-steel columns |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1220 Infinity II Analytical-Scale Purification |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 0.2–10 mL/min |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1260 Infinity II Analytical-Scale Purification |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 0.05–5 mL/min (with G7112B Pump) |
| Maximum Operating Pressure | 600 bar |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1260 Infinity II Manual Preparative |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 1–50 mL/min |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1260 Infinity II Preparative LC/MSD |
| Application Level | Laboratory-Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 1–50 mL/min |
| Maximum Operating Pressure | 20–420 bar |
