| Brand | Ecom (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | PREPBOX A3L8E |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | High-Pressure Preparative HPLC System |
| Flow Rate Range | 50–250 mL/min |
| Flow Rate Reproducibility | ±0.5% RSD (at 500 mL/min) |
| Maximum Pressure | 30 MPa |
| Wavelength Range | 200–800 nm |
| Wavelength Accuracy | ±0.4 nm |
| Detector Type | TOY18DAD 800L Four-Channel UV-Vis Diode Array Detector |
| Gradient Capability | Low-Pressure Quaternary Mixing (up to 4 solvents) |
| Fraction Collection | 10-position Valve-Based Fraction Collector |
| Control Software | ECOMAC v4.x (Embedded PC Platform) |
| Dimensions (W×H×D) | 405 × 490 × 525 mm |
| Weight | 55 kg |
| Power Supply | 100–240 V AC, 400 W |
| Interfaces | 5× USB, HDMI, 2× RS232, LAN, VGA |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Elite DAC-150 |
| Application Level | Laboratory & Pilot-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Column Internal Diameter | 150 mm (customizable) |
| Bed Height Range | 0–400 mm |
| Column Tube Material | ASTM A269 TP316L Stainless Steel |
| Maximum Operating Pressure | 20 MPa |
| Plate Count (for C18, 10 µm) | ≥40,000 N/m |
| Asymmetry Factor (As) | 0.9–1.2 |
| Drive Mechanism | Pneumatic-Hydraulic Actuation |
| Compliance | Designed to meet GMP design principles for pharmaceutical process development |
| Brand | Elite |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Models | EClassical 3140AP, 3500, 3700 |
| Price Range | USD 14,000 – 28,000 (FOB) |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative HPLC System |
| Flow Rate Range | 1–100 mL/min |
| Flow Accuracy | ≤3% |
| Flow Precision (RSD) | ≤±1.0% |
| Maximum Pressure | 30 MPa |
| Wavelength Range | 190–700 nm |
| Wavelength Reproducibility | RSD ≤0.3% |
| Baseline Noise | ≤±0.5×10⁻⁵ AU |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Class | Domestic |
| Model | EClassical3150 |
| Application Level | Laboratory-Grade |
| Instrument Type | High-Pressure Preparative HPLC |
| Flow Rate Range | 1–100 mL/min |
| Flow Accuracy | ±1.0% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 21 MPa |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | DAC Industrial Preparative |
| Application Level | Industrial Preparative |
| Instrument Type | High-Pressure Preparative Liquid Chromatography |
| Flow Rate Range (P500+) | 1–500 mL/min |
| Max Operating Pressure (P500+) | 20 MPa |
| Flow Accuracy (P500+) | ≤3% (at 5 MPa, water, 25°C, 250 mL/min) |
| Flow Precision (P500+) | RSD ≤0.5% |
| Pressure Drop (Seal Integrity) | ≤1.5 MPa |
| Operating Environment | 0–40°C / ≤80% RH |
| Power Consumption (P500+) | 800 W |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | P230A/P |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Semi-Preparative Liquid Chromatography |
| Pump Flow Range | 0.01–40.00 mL/min (0.01 mL/min increment) |
| Flow Accuracy | ≤ ±1.0% |
| Flow Precision (RSD) | ≤ 0.2% |
| Maximum Operating Pressure | 30 MPa |
| Power Supply | AC 220 V ±10%, 50 Hz / 200 W |
| Dimensions (L×W×H) | 420 × 280 × 175 mm |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic Instrument |
| Model | P230p |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0.10–40.00 mL/min (0.01 mL/min step) |
| Flow Accuracy | ≤±1.0% @ 10.00 mL/min, 8.5 MPa, H₂O, RT |
| Flow Precision (RSD) | ≤0.2% @ 10.00 mL/min, 8.5 MPa, H₂O, RT |
| Max Operating Pressure | 30 MPa (0.01–20.00 mL/min), 20 MPa (20.01–40.00 mL/min) |
| Pressure Display Error | ≤±3% |
| Pressure Pulsation | ≤1.0% |
| UV-Vis Detection Range | 190–720 nm (D₂ + W lamp) |
| Power Supply | AC 110/220 V, 50/60 Hz |
| Power Consumption | 200 W |
| Dimensions (L×W×H) | 420 × 280 × 175 mm |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | P270 |
| Application Level | Laboratory-Grade |
| Instrument Type | High-Pressure Preparative LC System |
| Flow Rate Range | 1.00–99.99 mL/min (0.01 mL/min increment) |
| Flow Accuracy | ≤±1.5% (at 30.00 mL/min, 8.5 MPa, water, 25°C) |
| Flow Precision (RSD) | ≤1.0% (at 30.00 mL/min, 8.5 MPa, water, 25°C) |
| Max Operating Pressure | 30 MPa (1.00–20.00 mL/min) |
| Pressure Display Error | ≤±3% |
| Pressure Pulsation | ≤3.0% |
| UV230+ Detector Wavelength Range | 190–720 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ±0.1 nm |
| Spectral Bandwidth | 6 nm |
| Response Time | 0.0–9.9 s |
| Linear Dynamic Range | ≥1.5 AU (5% deviation) |
| Baseline Noise | ≤±1.5×10⁻⁵ AU |
| Baseline Drift | ≤3×10⁻⁴ AU/h |
| LOD (Naphthalene in Methanol) | 1.0×10⁻⁸ g/mL |
| Flow Cell Pathlength | 3 mm |
| Flow Cell Volume | 5 µL |
| EC2000 Data Station | RS232 interface |
| Input Range | −100 mV to +2 V |
| Signal Resolution | 2 µV |
| Area Resolution | 0.1 µV·s |
| Channel Options | Single or Dual |
| Integration Reproducibility | ≤0.01% RSD |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | P3500 Semi-Preparative |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative HPLC |
| Flow Rate Range | 0.01–50.00 mL/min |
| Flow Accuracy | ≤ ±1.0% |
| Flow Precision (RSD) | ≤ 0.3% |
| Maximum Operating Pressure | 30 MPa |
| Wavelength Range | 190–700 nm |
| Baseline Noise | ≤ ±0.5 × 10⁻⁵ AU |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | P3700 Semi-Preparative |
| Application Level | Laboratory-Grade |
| Instrument Type | High-Pressure Preparative HPLC |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ≤ ±1.5% |
| Maximum Operating Pressure | 30 MPa |
| Wavelength Range | 190–700 nm |
| Baseline Noise | ≤ ±0.5 × 10⁻⁵ AU |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (PRC) |
| Model | S3150 |
| Price Range | USD 14,000 – 28,000 (FOB) |
| Application Tier | Industrial-Scale Preparative Chromatography |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 1–100 mL/min |
| Flow Precision (Partial-Loop Injection) | RSD ≤ 0.5% |
| Maximum Operating Pressure | 21 MPa |
| Brand | KEZHE Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | FlashDoctor-1000 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0–120 mL/min |
| Flow Accuracy | ±1.5% |
| Pressure Rating | 145 psi (1.0 MPa) |
| Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Spectral Bandwidth | 8 nm |
| Baseline Noise | ±0.2 mAU @ 254 nm |
| Baseline Drift | 0.2 mAU @ 254 nm |
| Fraction Collection | X-Y Robotic Matrix with 135-tube Capacity (standard 15 × 150 mm tubes) |
| Detection Options | Dual-Wavelength UV Detector (D₂ + Tungsten lamp) |
| Brand | KEZHE Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | FlashDoctor-1000Pro |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0–200 mL/min |
| Flow Accuracy | ±1.5% |
| Pressure Rating | 200 psi (13.8 bar) |
| Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Spectral Bandwidth | 8 nm |
| Baseline Noise | ±0.2 mAU @ 254 nm |
| Baseline Drift | 0.2 mAU/30 min @ 254 nm |
| Flow Path Configuration | Binary Solvent Delivery |
| Fraction Collection | X-Y Robotic Matrix (135-tube capacity, standard 15 × 150 mm tubes) |
| Detection Options | UV/Vis Detector (D₂ + Tungsten lamp), optional ELSD |
| Column Compatibility | Normal-phase (e.g., silica, 12 g & 25 g), reversed-phase (C18, 40 g), and empty loading columns (12 g) |
| Software Features | Method-based fraction triggering, peak integration & quantitation, audit trail, user management, lamp life monitoring, intensity calibration, TLC-guided method recommendation |
| Brand | KEZHE Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | FlashDoctor-2000 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0–300 mL/min |
| Flow Accuracy | ±2.0% |
| Flow Precision | <1.5% |
| Maximum Pressure | 300 psi (2.07 MPa) |
| Wavelength Range | 200–800 nm |
| Wavelength Accuracy | ±1 nm |
| Baseline Noise | ±0.2 mAU (at 254 nm) |
| Baseline Drift | 0.2 mAU/h (at 254 nm) |
| Spectral Bandwidth | 8 nm |
| Flow Cell Path Length | 0.3 mm |
| Detection Modes | UV-Vis (DAD), optional ELSD |
| Fraction Collection | 2D X-Y robotic collector (135-tube capacity, standard 15 × 150 mm tubes) |
| Column Compatibility | Reversible normal-phase and reversed-phase (e.g., C18), flash columns up to 40 mm ID |
| Software Compliance | Audit trail, user management, electronic signature support per FDA 21 CFR Part 11 requirements |
| System Architecture | Integrated benchtop unit, ventilated cabinet compatible |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | FLEXA |
| Price Range | USD 14,000–28,000 (FOB) |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 1–50/100 mL/min |
| Flow Accuracy | ±0.5% |
| Flow Precision | ±0.1% |
| Maximum Pressure | 30/20 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | ±0.75 × 10⁻⁵ AU |
| Data Acquisition Frequency | 3 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | Cs-Prep 1100, Cs-Prep 1200 |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0–300 L/h |
| Flow Accuracy | ±1.5% |
| Flow Precision (RSD) | ≤0.1% |
| Maximum Operating Pressure | 7 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU at 254 nm |
| Data Acquisition Frequency | 20 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Models | 200, 300, 450, 500, 600, 800, 1000 |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0–300 L/h |
| Flow Accuracy | ±1.5% |
| Flow Precision (RSD) | ≤0.1% |
| Maximum Operating Pressure | 10 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU (at 254 nm) |
| Data Acquisition Frequency | 20 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CS-Prep 1600 |
| Application Level | Industrial Preparative |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0–300 L/h |
| Flow Accuracy | ±1.5% |
| Flow Precision (RSD) | ≤0.1% |
| Maximum Operating Pressure | 7 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU @ 254 nm |
| Data Acquisition Frequency | 20 Hz |
| Regulatory Compliance | Designed and validated per GAMP5 |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | Intepure-F 200 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-to-Low Pressure Preparative HPLC System |
| Flow Rate Range | 1–200 mL/min |
| Flow Accuracy | ±2% |
| Flow Precision (RSD) | ±2% |
| Maximum Operating Pressure | 200 psi |
| Wavelength Range | 200–400 nm or 200–800 nm |
| Wavelength Reproducibility | ±0.5 nm |
| Baseline Noise | ±5 × 10⁻⁵ AU (254 nm, Time Constant 0.75 s) |
| Data Acquisition Rate | 20 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | Intepure-F 300 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-to-Low Pressure Preparative HPLC System |
| Flow Rate Range | 1–300 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ±1% |
| Maximum Operating Pressure | 500 psi |
| Wavelength Range | 200–400 nm or 200–800 nm |
| Wavelength Repeatability | ±0.5 nm |
| Baseline Noise | ±5 × 10⁻⁵ AU (254 nm, Time Constant 0.75 s) |
| Data Acquisition Rate | 20 Hz |
| Brand | Hanbon |
|---|---|
| Model | NP-7000 Series |
| Type | High-Pressure Preparative Liquid Chromatography Pump |
| Flow Range (NP7030C) | 0.01–300.00 mL/min, Increment: 0.01 mL/min |
| Flow Range (NP7060C) | 0.01–600.00 mL/min, Increment: 0.01 mL/min |
| Flow Range (NP7100C) | 0.1–1000.0 mL/min, Increment: 0.1 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Pressure Pulsation | ≤0.5 MPa |
| Max Pressure (NP7030C) | 15 MPa |
| Max Pressure (NP7060C/NP7100C) | 10 MPa |
| Tubing Connection | 1/8″ Standard Fitting |
| Display | 320×240 LCD |
| Control Interface | Front-panel keypad + RS232/USB computer remote control |
| Power Input | 85–264 VAC |
| Power Consumption (NP7030C/NP7060C) | 500 W |
| Power Consumption (NP7100C) | 750 W |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | NP7005-10C |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | Medium-to-Low Pressure Preparative Liquid Chromatography System |
| Flow Accuracy | ±0.5% over full range (0.01–100 mL/min) |
| Flow Pulsation | <0.1% RMS (measured at 1 mL/min, 10 MPa) |
| Maximum Operating Pressure | 10 MPa |
| Display | 4.7-inch TFT LCD (320 × 240 pixels) |
| User Programs | 10 stored gradient methods |
| Communication Interface | Open ASCII-based RS-232/RS-485 protocol compliant with ASTM E1381 and IEEE 11073 standards |
| Column Cleaning Mode | Optional automated back-flush for piston and seal assembly |
| Seal Lifetime Extension | Enabled via programmable solvent rinse during idle and gradient hold phases |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | NS4205 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC System |
| Flow Rate Range | 0.01–49.99 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.1% |
| Maximum Pressure | 25 MPa |
| Wavelength Range | 190–800 nm (±2 nm accuracy) |
| Wavelength Reproducibility | ±0.2 nm |
| Baseline Noise | ≤2×10⁻⁵ AU (254 nm, 1 s time constant) |
| Data Acquisition Rate | 5 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | NS4210 |
| Price Range | USD 14,000 – 28,000 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC System |
| Flow Rate Range | 0.01–100 mL/min |
| Flow Accuracy | ±0.5% |
| Flow Precision (RSD) | ≤0.1% |
| Maximum Pressure Rating | 20 MPa |
| Wavelength Range | 190–700 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU |
| Data Acquisition Frequency | 5 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | NS43100 |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0.01–599.99 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤1% |
| Maximum Operating Pressure | 15 MPa |
| Wavelength Range | ±2 nm |
| Wavelength Reproducibility | 0.2 nm |
| Baseline Noise | 2 × 10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 5 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | NS4330 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0.1–3000.0 mL/min |
| Flow Accuracy | ±1.5% |
| Flow Precision (RSD) | ≤1% |
| Maximum Pressure | 15 MPa |
| Wavelength Range | 0.5 nm |
| Wavelength Reproducibility | 0.1 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU |
| Data Acquisition Frequency | 5 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Producer |
| Product Category | Domestic |
| Model | NS43300 |
| Application Level | Industrial Preparative |
| Instrument Type | High-Pressure Preparative HPLC |
| Flow Rate Range | 0.1–2999.9 mL/min |
| Flow Accuracy | RSD ≤ 1% |
| Flow Precision (Repeatability) | ≤ 1% |
| Maximum Operating Pressure | 10 MPa |
| Wavelength Range | ±2 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | 2 × 10⁻⁵ AU |
| Data Acquisition Frequency | 5 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | NS4360 |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0.01–599.99 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤1% |
| Maximum Pressure | 15 MPa |
| Wavelength Range | ±2 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | 2 × 10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 5 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | NS9001S |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-to-Low Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 0–99.99 mL/min |
| Flow Accuracy | ±0.5% |
| Flow Precision (RSD) | ≤0.1% |
| Maximum Operating Pressure | 1 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | 0.5 × 10⁻⁵ AU |
| Data Acquisition Frequency | 50 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | NS9002S |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0–99.99 mL/min |
| Flow Accuracy | ±0.5% |
| Flow Precision (RSD) | ≤0.1% |
| Maximum Operating Pressure | 15 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | 0.5 × 10⁻⁵ AU |
| Data Acquisition Frequency | 50 Hz |