Empowering Scientific Discovery

Allsheng K30 Economical Dry Block Heater

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Allsheng
Origin Zhejiang, China
Model K30 Economical Dry Block Heater
Temperature Range Ambient +5°C to 100°C
Temperature Accuracy ±0.5°C
Heating Time (20°C to 100°C) ≤15 min
Dimensions (W×D×H) 225 mm × 160 mm × 197 mm
Net Weight 3 kg
Power Supply AC 220 V / 120 V, 50 / 60 Hz
Rated Power 100 W
Certifications CE
Timer Range 1 min – 99 h 59 min
Safety Features Over-temperature protection, auto-shutdown, audible alarm at end of cycle
Cooling Method Integrated fan-assisted cooling
Block Type Interchangeable circular aluminum block
Display Dual LED display showing real-time temperature and countdown timer

Overview

The Allsheng K30 Economical Dry Block Heater is a compact, precision-engineered thermal incubation device designed for consistent, contact-based sample heating in routine laboratory workflows. Operating on the principle of conductive heat transfer via a thermally optimized aluminum heating block, the K30 delivers stable temperature control across a usable range from ambient +5°C to 100°C—ideal for enzyme activation, DNA denaturation, cell culture pre-warming, reagent equilibration, and sample thawing applications. Its dry-block architecture eliminates reliance on water baths, thereby minimizing contamination risk, evaporation loss, and maintenance overhead. The unit features a rigid, injection-molded ABS housing with integrated ventilation and an optically clear polycarbonate lid that prevents ambient interference while enabling visual monitoring without compromising thermal stability.

Key Features

  • Interchangeable circular aluminum heating blocks—compatible with standard microcentrifuge tubes (0.2 mL, 0.5 mL, 1.5 mL, 2.0 mL), PCR strips, and small vials—enabling rapid adaptation across assay formats.
  • Dual-function LED display simultaneously shows real-time block temperature and programmable countdown timer, supporting intuitive operation without menu navigation.
  • Precision PID temperature control with ±0.5°C accuracy at setpoint and built-in offset calibration capability for traceable thermal validation.
  • Integrated over-temperature safety cutoff with automatic shutdown and visual/audible alert—compliant with IEC 61010-1 requirements for laboratory electrical equipment.
  • Fan-assisted active cooling system reduces cooldown time significantly compared to passive dissipation, improving throughput between sequential runs.
  • Transparent polycarbonate lid minimizes convective heat loss and prevents accidental contamination or sample displacement during handling.
  • Compact footprint (225 × 160 × 197 mm) and lightweight design (3 kg) facilitate placement on crowded benchtops or integration into automated workstations.

Sample Compatibility & Compliance

The K30 accommodates common single-tube and strip-based consumables used in molecular biology, clinical diagnostics, and quality control laboratories. Its standardized circular block geometry ensures uniform thermal coupling across tube types, reducing inter-sample variability. While not intended for GLP/GMP-regulated environments requiring full 21 CFR Part 11 compliance, the device supports basic auditability through manual log entry of operating parameters (setpoint, duration, block ID). It bears CE marking per Directive 2014/30/EU (EMC) and 2014/35/EU (LVD), confirming conformity with essential health and safety requirements for electrical laboratory equipment in the European Economic Area.

Software & Data Management

The K30 operates as a standalone instrument with no embedded software, network interface, or data logging capability. All configuration and operation are performed manually via front-panel controls. This design prioritizes reliability, electromagnetic immunity, and operational simplicity—particularly advantageous in high-noise industrial labs or resource-constrained educational settings. Users may document run conditions using external lab notebooks or LIMS-integrated manual entry. For environments requiring electronic records, the K30 can be paired with external temperature dataloggers (e.g., compliant thermocouple probes with USB output) for post-hoc validation.

Applications

  • Pre-heating restriction enzymes and ligases prior to digestion/ligation reactions.
  • Equilibrating PCR master mixes and reverse transcription reagents to reduce condensation and improve reaction consistency.
  • Controlled thawing of cryopreserved cell suspensions and serum aliquots to minimize thermal shock.
  • Incubating immunoassay reagents and ELISA plates at defined temperatures during protocol steps.
  • Supporting QC testing in pharmaceutical manufacturing where ISO 17025-accredited thermal verification is performed externally.
  • Teaching laboratories requiring robust, low-maintenance thermal platforms for undergraduate biochemistry and microbiology curricula.

FAQ

Is the K30 compatible with 0.2 mL PCR tubes in strip format?
Yes—the standard circular block includes recesses for 8-well and 12-well PCR strips, as well as individual 0.2 mL tubes.
Can the temperature calibration be adjusted by the user?
Yes—built-in offset calibration allows technicians to apply a compensatory value (±9.9°C) to correct for minor deviations observed during external verification with a calibrated reference thermometer.
Does the unit include interchangeable blocks for different tube sizes?
The base configuration includes one circular aluminum block; optional blocks (e.g., for 15 mL or 50 mL conical tubes) are available under separate part numbers and are mechanically compatible with the K30 chassis.
What is the maximum ambient operating temperature for reliable performance?
For optimal thermal stability and controller longevity, operation is recommended at ambient temperatures between 15°C and 30°C and relative humidity ≤80% non-condensing.
Is fan noise a concern during sensitive acoustic experiments?
The cooling fan operates only during cooldown or sustained high-temperature operation (>85°C); its acoustic output is <35 dB(A) at 1 m distance—suitable for standard laboratory environments but not anechoic chambers.