Empowering Scientific Discovery

BIO-DL BT-100 Precision Metal Block Heater

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand BIO-DL
Model BT-100
Type Metal Block Heater
Origin Shanghai, China
Control System Microprocessor-based PID Temperature Control
Temperature Range Ambient +5°C to 100°C
Temperature Accuracy ±0.3°C at 37°C
Temperature Uniformity ±0.5°C across block surface
Block Material Aluminum alloy with anodized finish
Block Configurations Standard 96-well plate, 0.2 mL & 0.5 mL PCR tube compatibility (interchangeable blocks available)
Power Supply 100–240 VAC, 50/60 Hz
Dimensions (W×D×H) 260 × 190 × 120 mm
Weight 2.8 kg
Safety Certifications CE, RoHS compliant
Compliance Designed for GLP-compliant laboratories

Overview

The BIO-DL BT-100 Precision Metal Block Heater is a microprocessor-controlled dry bath system engineered for high-reproducibility thermal incubation of biological and chemical samples. Unlike water baths—where evaporation, contamination risk, and thermal lag compromise consistency—the BT-100 employs solid aluminum alloy heating blocks with optimized thermal mass and uniform heat distribution. Its PID-controlled temperature regulation ensures stable setpoint maintenance across the entire block surface, minimizing inter-well or inter-tube thermal variance critical in molecular biology workflows such as enzymatic reactions, nucleic acid denaturation, and immunoassay incubations. The device operates within a calibrated range of ambient +5°C to 100°C, with documented accuracy of ±0.3°C at 37°C and uniformity of ±0.5°C across the working area—parameters verified per ISO 17025 traceable calibration protocols.

Key Features

  • Microprocessor-based PID temperature control with real-time digital display and adjustable ramp rate
  • Anodized aluminum heating block offering rapid thermal equilibration (<6 min to reach 37°C from ambient) and corrosion resistance
  • Interchangeable block modules supporting common labware formats: 96-well PCR plates, 0.2 mL and 0.5 mL PCR tubes, 1.5 mL and 2.0 mL microcentrifuge tubes
  • Over-temperature protection circuit and auto-shutdown function for unattended operation
  • Low electromagnetic interference design compatible with sensitive instrumentation in shared lab environments
  • Compact footprint (260 × 190 × 120 mm) and lightweight construction (2.8 kg) enabling flexible benchtop deployment

Sample Compatibility & Compliance

The BT-100 accommodates standard laboratory consumables without requiring adapters or custom inserts. Its block geometry maintains consistent thermal contact with tube bases and well bottoms, eliminating air gaps that cause localized cooling—particularly essential for RNA integrity preservation during reverse transcription or DNase-free incubations. The unit complies with CE and RoHS directives and is constructed using materials certified for use in ISO 13485–registered medical device manufacturing facilities. While the hardware itself does not require FDA registration, its performance characteristics support compliance with USP , , and CLSI EP23 guidelines for thermal validation in QC/QA applications. When operated within defined SOPs—including routine verification using NIST-traceable thermistors—it meets GLP documentation requirements for regulated testing laboratories.

Software & Data Management

The BT-100 operates as a standalone instrument with no embedded data logging capability. However, it is fully compatible with third-party environmental monitoring systems via optional RS-232 or USB-to-serial interface (available as accessory kit). When integrated with validated laboratory information management systems (LIMS) or electronic lab notebooks (ELN), temperature setpoints, duration, and operator ID can be recorded externally to satisfy 21 CFR Part 11 audit trail requirements. BIO-DL provides IQ/OQ documentation templates aligned with ASTM E2500-13 and ISO/IEC 17025 Annex A.2 for installation and operational qualification, facilitating GMP-aligned commissioning in pharmaceutical and clinical diagnostic settings.

Applications

  • DNA/RNA extraction and purification protocols requiring precise incubation at 56°C (proteinase K digestion) or 70°C (RNase inactivation)
  • PCR setup stages including hot-start enzyme activation and pre-amplification template denaturation
  • Enzyme-linked immunosorbent assay (ELISA) plate incubations at 37°C with minimal edge-effect deviation
  • Cell lysis buffer pre-warming and reagent equilibration prior to flow cytometry or mass spectrometry sample prep
  • Stability studies for small-molecule formulations under accelerated thermal conditions (e.g., 40°C/75% RH chamber adjunct)
  • Calibration verification of thermocouples and infrared thermometers using fixed-point reference blocks

FAQ

Does the BT-100 support programmable multi-step temperature profiles?
No—the BT-100 is a single-setpoint heater. For gradient or time-segmented protocols, users must integrate it with external programmable controllers or select the BT-200 series.
Can the heating block be autoclaved?
No—aluminum blocks are not autoclavable. Clean with 70% ethanol or isopropanol; avoid abrasive cleaners or immersion in liquid.
Is temperature calibration performed at the factory?
Yes—each unit undergoes three-point calibration (25°C, 37°C, 70°C) using NIST-traceable reference thermometers prior to shipment. A certificate of conformance is included.
What is the recommended recalibration interval?
Annual recalibration is advised for GLP/GMP environments; biannual verification is sufficient for academic or industrial R&D labs per ISO/IEC 17025 Clause 6.5.2.
Are custom block geometries available?
Yes—BIO-DL offers OEM block design services for non-standard tube formats or plate layouts, subject to minimum order quantities and lead time confirmation.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0