Empowering Scientific Discovery

BOXUN BC-J80 Water-Jacketed CO₂ Incubator with Infrared CO₂ Sensor

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand BOXUN
Origin Shanghai, China
Manufacturer Type Direct Manufacturer
Product Category Domestic (China-Made)
Model BC-J80 (Water-Jacketed, Infrared CO₂ Sensing)
Temperature Range & Accuracy Ambient +5°C to 60°C
Temperature Uniformity ≤ ±0.5°C at 37°C
Chamber Capacity 80 L
CO₂ Range 0–20%
CO₂ Sensor Type Imported Infrared (IR) Sensor
CO₂ Recovery Time ≤ (Setpoint %) × 1.2 min
Temperature Fluctuation ≤ ±0.3°C at 37°C
Temperature Resolution 0.1°C
Humidity Control Natural Evaporation
Power Supply AC 220 V ±10%, 50 Hz ±2%
Input Power 600 W
Chamber Dimensions (W×D×H) 420 × 400 × 550 mm
External Dimensions (W×D×H) 562 × 521 × 960 mm
Shelving 2 Adjustable Stainless Steel Trays
Filtration Efficiency ≥99.998% for particles ≥0.3 µm
Interface RS-485 for PC/Logger Connectivity
Backup Function Power-Fail Parameter Memory & Auto-Restore

Overview

The BOXUN BC-J80 is a precision-engineered water-jacketed CO₂ incubator designed for reliable, long-term cell and tissue culture under tightly controlled physiological conditions. Utilizing a stable water-jacket thermal mass combined with dual temperature sensors and chip-based adaptive suppression control, the BC-J80 maintains exceptional thermal stability—critical for sensitive mammalian cell lines, primary cultures, and stem cell expansion. Its infrared (IR) CO₂ sensing system delivers high-fidelity, drift-resistant gas concentration monitoring across the full 0–20% range, enabling accurate replication of in vivo partial pressures. Unlike forced-air designs, the water-jacket architecture provides superior thermal inertia and uniformity, minimizing transient fluctuations during door openings or ambient temperature shifts—key for GLP-compliant workflows and reproducible assay outcomes.

Key Features

  • Water-jacketed chamber with integrated heating elements and thermal mass for enhanced temperature stability and reduced energy consumption over time
  • Imported non-dispersive infrared (NDIR) CO₂ sensor offering fast response (<1.2 min recovery per % setpoint), long-term calibration stability, and immunity to cross-sensitivity from humidity or volatile organics
  • Dual independent temperature control system: primary microprocessor controller with secondary hardware-level monitoring circuitry for fail-safe operation and continuous parameter oversight
  • High-efficiency dual-stage filtration: pre-filter + HEPA-grade filter (≥99.998% retention for ≥0.3 µm particles) integrated into recirculation path to maintain ISO Class 5-equivalent internal air quality
  • UV germicidal lamp (254 nm) with programmable activation cycles for routine decontamination of chamber surfaces and air stream
  • Door-heating module prevents condensation on inner glass door—eliminating optical interference during microscopic observation and reducing microbial harbor points
  • Intelligent anti-condensation algorithm and natural evaporation humidification system maintain relative humidity ≥90% RH at 37°C without external water reservoirs or complex steam generators
  • RS-485 serial interface compliant with Modbus RTU protocol for integration into laboratory building management systems (BMS) or centralized data logging platforms

Sample Compatibility & Compliance

The BC-J80 supports a broad spectrum of biological samples including adherent and suspension mammalian cell lines (e.g., HeLa, CHO, HEK293), primary neurons, mesenchymal stem cells (MSCs), hybridomas, and microbial cultures requiring CO₂ supplementation (e.g., capnophilic bacteria). Its stainless steel mirror-finish interior, rounded corners, and seamless welds facilitate cleaning validation per ISO 14644-1 and support routine autoclave-compatible component sterilization. The system meets essential safety and performance criteria aligned with IEC 61010-1 (Electrical Safety for Laboratory Equipment) and incorporates design features supporting compliance with FDA 21 CFR Part 11 when paired with validated electronic log software. Temperature and CO₂ data integrity is preserved via non-volatile memory with power-loss recovery—ensuring audit-trail continuity during facility-wide outages.

Software & Data Management

While the BC-J80 operates as a standalone unit with intuitive front-panel LCD interface (simultaneous display of temperature, CO₂ %, and RH), its RS-485 port enables bidirectional communication with third-party SCADA, LIMS, or custom Python/Node-RED-based monitoring dashboards. Optional accessories—including thermal printer modules (for real-time trend curve output), GPRS-enabled SMS alerting (for out-of-specification events), and Ethernet-to-RS485 gateways—extend traceability capabilities. All logged parameters—including timestamps, setpoints, actual readings, alarm states, and door-open duration—are timestamped and stored with checksum verification to satisfy internal QA requirements and preparatory documentation for ISO/IEC 17025 or CAP accreditation audits.

Applications

  • Cell-based assays in drug discovery pipelines, including cytotoxicity screening, proliferation kinetics, and reporter gene expression studies
  • Clinical and academic research involving human induced pluripotent stem cells (iPSCs), where tight regulation of pH (via CO₂/bicarbonate buffering) and thermal homogeneity directly impact differentiation efficiency
  • Biomanufacturing process development for monoclonal antibody production using CHO host systems
  • Microbiology labs culturing fastidious organisms such as Helicobacter pylori, Neisseria gonorrhoeae, and Campylobacter jejuni, which require precise CO₂ enrichment for optimal growth
  • Regulatory-compliant stability testing environments for biologics, where incubator qualification (IQ/OQ/PQ) is performed using documented protocols aligned with ASTM E2876 and USP <1033>

FAQ

What type of CO₂ sensor does the BC-J80 use, and why is it preferred over thermal conductivity sensors?

The BC-J80 employs an imported NDIR infrared sensor, which offers superior specificity, linearity, and resistance to drift compared to thermal conductivity (TC) sensors—especially in high-humidity environments common in cell culture applications.
Is the water jacket refillable, and how often does it require maintenance?

Yes—the water jacket is manually filled via a dedicated port and requires quarterly inspection for water level and microbial contamination. Deionized water is recommended to prevent mineral buildup.
Can the BC-J80 be qualified for GMP environments?

Yes—its hardware redundancy, data logging capability, alarm history, and mechanical design support formal IQ/OQ/PQ execution per Annex 15 and WHO TRS 986 guidelines when used with appropriate validation protocols and calibrated reference standards.
Does the unit include alarms for door ajar, CO₂ depletion, or temperature deviation?

Yes—audible and visual alerts activate for high/low temperature, CO₂ out-of-range, door left open >30 seconds, UV lamp failure, and water jacket low-level conditions.
Are replacement HEPA filters and UV lamps available as genuine BOXUN parts?

Yes—BOXUN supplies certified filter assemblies (part #BC-J80-HEPA-KIT) and low-pressure mercury UV-C lamps (254 nm, 15 W) with documented lifetime specifications and spectral output verification reports.