Empowering Scientific Discovery

BOXUN GZX-9246MBE Forced-Air Hot Air Oven

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand BOXUN
Origin Shanghai, China
Model GZX-9246MBE
Temperature Range Ambient +5°C to 300°C
Temperature Uniformity ±2.5%
Temperature Fluctuation ±1°C (at 105°C)
Temperature Resolution 0.1°C
Interior Dimensions (W×D×H) 630×530×630 mm
Exterior Dimensions (W×D×H) 775×746×902 mm
Inner Chamber Material Mirror-Finish Stainless Steel
Heating Method Forced-Air Circulation with Preheated Air Inlet
Power Input 2750 W
Timer Range 0–9999 min/h (selectable)
Standard Shelving 3 adjustable shelves (max. 8)
Shelf Load Capacity 15 kg per shelf
Operating Ambient Temperature 5–40°C
Compliance GB/T 30435–2013

Overview

The BOXUN GZX-9246MBE is a microprocessor-controlled forced-air hot air oven engineered for precision thermal processing in laboratory, industrial quality control, and research environments. It operates on the principle of convective heat transfer via a high-efficiency axial fan and preheated air inlet system—ensuring rapid temperature ramp-up and uniform thermal distribution across the working chamber. Designed for applications including moisture loss determination, sterilization of glassware and instruments, polymer curing, pharmaceutical stability testing, and residue drying, the unit maintains stable setpoint accuracy under variable load conditions. Its robust architecture supports continuous operation at temperatures up to 300°C, meeting routine thermal validation requirements for GLP-compliant laboratories and ISO 17025-accredited testing facilities.

Key Features

  • Mirror-finish stainless steel interior chamber (630 × 530 × 630 mm) resistant to corrosion and easy to decontaminate
  • Preheated air mixing chamber ensures homogeneous airflow and minimizes thermal stratification
  • PMMA II operating system with capacitive touch interface and color-enhanced digital display showing real-time temperature, timer status, and alarm indicators
  • Two-stage rotary door lock mechanism with high-compression silicone gasket for optimal sealing and energy efficiency
  • Four-corner rounded chamber design and tool-free removable shelves simplify cleaning and maintenance
  • Intelligent power recovery function retains set parameters and resumes operation after unexpected power interruption or system reset
  • Over-temperature alarm with independent mechanical safety cutoff (dual-limit thermostat) for fail-safe operation
  • High-density mineral wool insulation (≥80 mm thickness) reduces external surface temperature and improves thermal retention

Sample Compatibility & Compliance

The GZX-9246MBE accommodates standard laboratory glassware (e.g., Petri dishes, weighing bottles, crucibles), metal trays, and polymer substrates up to 15 kg per shelf. Its chamber geometry supports stacked sample arrangements without compromising airflow integrity. The unit conforms to GB/T 30435–2013 “Electric Hot Air Ovens for Laboratory Use” and incorporates design elements aligned with broader international expectations for Class II laboratory ovens per IEC 61010-1:2010 (Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use). While not certified to UL or CE for export markets without regional adaptation, its construction, sensor redundancy, and thermal management align with baseline requirements for FDA-regulated environments conducting non-critical thermal processes (e.g., residual solvent removal, filter drying).

Software & Data Management

The onboard PMMA II controller provides local data handling only—no network connectivity or PC interface is included. All operational parameters (setpoint, dwell time, ramp rate, alarm thresholds) are stored in non-volatile memory and persist through power cycles. The system logs no audit trail or timestamped event history; however, its parameter retention capability satisfies basic GLP documentation needs for routine drying protocols where manual logbook entries remain standard practice. For users requiring electronic records compliant with 21 CFR Part 11, third-party data loggers with calibrated Pt100 inputs may be integrated via the rear-mounted analog output port (0–5 V DC proportional to chamber temperature).

Applications

  • Moisture content analysis per AOAC 950.46 and ASTM D2231 (rubber, plastics, textiles)
  • Drying of filter papers and gravimetric precipitates in environmental and chemical labs
  • Thermal conditioning of samples prior to XRD, SEM, or TGA analysis
  • Pre-sterilization of reusable labware in microbiology and cell culture facilities
  • Curing of epoxy-coated specimens and adhesion test panels in materials science
  • Accelerated aging studies for packaging materials under controlled thermal stress

FAQ

What is the maximum operating temperature and thermal stability specification?
The unit achieves a maximum setpoint of 300°C with a temperature fluctuation of ±1°C at 105°C (per GB/T 30435–2013 test protocol); stability at higher setpoints is manufacturer-specified but not independently verified.
Does the oven support programmable ramp/soak cycles?
No—the GZX-9246MBE offers only single-setpoint temperature control with timer-based dwell functionality; multi-step profiles require external programmable controllers.
Is the internal temperature sensor traceably calibrated?
The unit ships with a factory-calibrated PT100 sensor; NIST-traceable calibration certificates are available as optional add-ons upon request.
Can the oven be used for biological sterilization?
It meets thermal disinfection requirements for dry heat (e.g., 160°C for 2 hours), but does not comply with EN 285 or ISO 17665 for steam sterilization validation.
What maintenance intervals are recommended?
Fan motor lubrication and gasket inspection are advised every 12 months; airflow verification using calibrated thermocouples is recommended before critical validation runs.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0