DeChem-Tech CleverChem Anna Fully Automated Tobacco Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand DeChem-Tech
Origin Germany
Model CleverChem Anna
Detection Principle Automated Segmented Flow Analysis (SFA) with Photometric Detection
Sample Throughput Up to 200 samples/hour
Sample Capacity 49 positions
Reagent Positions 31 (with optional refrigerated storage)
Optical Cell 64-position quartz cuvette carousel, 1 cm path length, reusable
Cleaning 8-step ultrasonic washing station with optical validation
Dilution Capability On-board 1 mL dilutor, up to 100× automatic dilution in cuvette
Blank Correction True sample blank and reagent blank compensation
Waste Management Sealed waste sensing & collection system
Software Dual-language (English/Chinese), compliant with GLP audit trail requirements
Regulatory Alignment Methods validated per China National Tobacco Industry Standards (e.g., YC/T 247–2008, YC/T 160–2002, YC/T 173–2003)

Overview

The DeChem-Tech CleverChem Anna Fully Automated Tobacco Analyzer is a dedicated segmented flow analysis (SFA) system engineered for high-precision, regulatory-compliant quantification of key chemical constituents in tobacco leaf, stem, extract, and digested matrices. Operating on the photometric principle, the instrument automates the precise metering of sample aliquots and reagents into a continuously flowing carrier stream, where controlled mixing, reaction timing, and thermal incubation occur within chemically inert tubing. Colorimetric reactions—such as those for nitrate (via cadmium reduction), phosphate (molybdenum blue), ammonia (indophenol blue), nicotine (UV absorption after extraction), and cyanide (pyridine-barbituric acid)—are completed under optimized conditions before entering a temperature-stabilized quartz flow cell. Absorbance is measured at user-defined wavelengths (typically 400–800 nm) using a high-stability tungsten-halogen light source and precision photodiode detector. Concentrations are calculated in real time via calibrated linear or quadratic regression models, with full traceability of calibration history, drift correction, and outlier rejection.

Key Features

  • Fully integrated SFA architecture eliminating manual pipetting, timing errors, and inter-operator variability—designed specifically for tobacco matrix complexity including high tannin, alkaloid, and particulate content.
  • Reusable 64-position quartz cuvette carousel with 1 cm optical path; each cuvette undergoes rigorous 8-step ultrasonic cleaning followed by automated optical transmittance verification prior to reuse.
  • On-board 1 mL precision dilutor enabling dynamic 2× to 100× dilution directly within the measurement cuvette—critical for handling out-of-range nicotine, nitrate, or sugar concentrations without manual intervention.
  • 49-sample capacity with programmable priority queuing; supports unattended overnight runs with auto-start capability and low-level alerts for reagent or waste thresholds.
  • 31 reagent positions housed in an optional 4–8 °C refrigerated compartment to preserve stability of light-sensitive or thermally labile reagents (e.g., diazotized sulfanilamide for nitrite).
  • True dual-blank correction: independent measurement of reagent blank (reagent + carrier only) and sample blank (sample + carrier, no reagent) to eliminate matrix color interference and baseline drift.
  • Sealed, pressure-balanced waste collection with level-sensing and vapor-trapping design—fully compliant with OSHA HAZCOM and ISO 15190 laboratory safety standards.

Sample Compatibility & Compliance

The CleverChem Anna accepts filtered tobacco extracts (aqueous or acidic digestates), centrifuged supernatants, and clarified infusions without pre-dilution or filtration step integration. It accommodates viscosity ranges typical of tobacco extracts (up to 8 mPa·s) and tolerates suspended solids ≤5 µm when properly pre-filtered (0.45 µm syringe filter recommended). All validated methods align with China National Tobacco Corporation standards—including YC/T 247–2008 (total sugar), YC/T 160–2002 (nitrate), YC/T 173–2003 (ammonia), and YC/T 472–2013 (hydrocyanic acid). Method transfer documentation, LOD/LOQ studies, and ruggedness testing reports are provided per ICH Q2(R2) guidelines. The system supports 21 CFR Part 11-compliant electronic signatures and full audit trail logging for GxP environments.

Software & Data Management

Control and data processing are executed via CleverChem Control Suite v5.x—a Windows-based application supporting English and Chinese UI localization. The software implements role-based access control (RBAC), method versioning, and electronic batch records (EBR) with timestamped metadata for every injection, calibration, and maintenance event. Raw absorbance traces, peak integration parameters, and curve-fitting residuals are stored in vendor-neutral .csv and .xlsx formats. Export modules support LIMS integration via ASTM E1384-compliant HL7 messaging or direct SQL database push. All data files include embedded digital signatures and SHA-256 checksums to ensure integrity during archival or regulatory submission.

Applications

  • Quantification of nitrogen species: total nitrogen (Kjeldahl digestion-coupled), ammonia, nitrate, nitrite, and volatile alkaloids (nicotine, nornicotine, anatabine).
  • Carbohydrate profiling: total reducing sugars (Lane-Eynon), sucrose, glucose, fructose, and starch-derived glucose after enzymatic hydrolysis.
  • Anion analysis: chloride, sulfate, phosphate, and cyanide in cured leaf, stem, and mainstream smoke condensate.
  • Quality control of tobacco blends: real-time monitoring of sugar-to-nicotine ratio, nitrate-to-ammonia balance, and curing-related alkaloid conversion kinetics.
  • Regulatory compliance testing for export batches: alignment with EU Directive 2014/40/EU (TPD) and WHO Framework Convention on Tobacco Control (FCTC) reporting requirements.

FAQ

Does the CleverChem Anna require external digestion equipment for total nitrogen analysis?
Yes—total nitrogen determination requires prior Kjeldahl or high-temperature catalytic digestion (e.g., using a DEKATI Digester or similar). The CleverChem Anna measures the resulting ammonium ion post-digestion.
Can the system run multiple methods simultaneously across different sample racks?
No—method selection is rack-wide. However, up to 8 independent methods can be queued sequentially within a single run file, with automatic reagent switching and parameter reconfiguration between batches.
What is the minimum detectable concentration for nicotine in tobacco extract?
Typical LOD is 0.08 mg/L (as nicotine base) in 1:10 diluted aqueous extract, based on 3σ of 10 replicate blanks (n=10, CV < 1.2%).
Is third-party method validation support available?
Yes—DeChem-Tech provides IQ/OQ/PQ protocols, reference material traceability statements (NIST SRM 1577c), and on-site method transfer assistance for ISO/IEC 17025-accredited labs.
How often must the quartz cuvettes be replaced?
Under standard tobacco matrix usage and proper ultrasonic cleaning, cuvettes maintain optical integrity for ≥5,000 measurements. Replacement is triggered automatically upon failed transmittance validation (threshold: <92% at 400 nm).