| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | CleverChem 300 |
| Instrument Type | Laboratory-Based Wet-Chemistry Analyzer |
| Detection Capability | Multi-Parameter |
| Analysis Speed | Up to 300 samples/hour |
| Sample Volume Range | 1–900 µL (1 µL increment) |
| Reagent Volume Range | 1–450 µL (1 µL increment) |
| Sample Positions | 49 per removable tray |
| Reagent Positions | 31 |
| Cuvette Capacity | 64-position rotating cuvette carousel |
| Reaction Temperature Control | Ambient to 49.6 °C (standard assay temp: 38.0 ± 0.1 °C) |
| Optical System | Dual-beam photometry with 24-bit digital detector |
| Wavelength Range | 340–880 nm |
| Filter Wheel | 9 measurement + 1 reference filter positions |
| Absorbance Linearity | 0.0001–3.5000 Abs |
| Absorbance Resolution | 0.0001 Abs |
| Cuvette Cleaning | 7-step automated protocol |
| Auto-Dilution | Up to 100× |
| Low-Volume Alerts | Sample & reagent level monitoring enabled |
| Compliance | Methods aligned with ISO, US EPA, and GB standards |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | CleverChem 380 |
| Product Type | Discrete Analyzer |
| Wavelength Range | 400–900 nm |
| Sample Volume per Vial | 5 mL |
| Reagent Positions | 49 |
| Cuvette Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | CleverChem 380 |
| Instrument Type | Fertilizer & Plant Nutrient Analyzer |
| Sample Capacity | 119 positions |
| Throughput | Up to 350 samples/hour |
| Optical Cell | 64-position quartz cuvette tray, 1 cm path length |
| Reagent Positions | 49 (with optional refrigerated storage) |
| Dispensing Range | 1–450 µL (reagents), 1–400 µL (samples) |
| On-board Dilution | Up to 100× in cuvette |
| Cleaning | 8-step ultrasonic cuvette cleaning station |
| Compliance | ISO, US EPA, and GB standards |
| Software | Dual-language (English/Chinese), supports sample blank & reagent blank correction |
| Waste Management | Sealed waste sensing & collection system |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | CleverChem-380 |
| Sample Capacity | 119 positions |
| Reagent Positions | 49 (with refrigerated storage) |
| Optical Cell | 64-position quartz cuvette carousel, 1 cm pathlength |
| Throughput | up to 350 samples/hour |
| Dilution Range | 1–100× in-cuvette dilution |
| Cleaning | 8-step ultrasonic cuvette washing station with optical validation |
| Detection Principle | Photometric colorimetry (absorbance measurement at defined wavelengths) |
| Software | Dual-language (English/Chinese), compliant with GLP data integrity requirements |
| Waste Management | Sealed waste sensing and containment system |
| Compliance | Methods aligned with China National Tobacco Industry Standards (e.g., YC/T series) |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | CleverChem 380 |
| Product Type | Discrete Flow Analyzer |
| Wavelength Range | 400–900 nm |
| Sample Volume per Vial | 5 mL |
| Reagent Positions | 49 |
| Cuvette Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | CleverChem 380Plus |
| Product Type | Discrete Flow Analyzer |
| Wavelength Range | 400–900 nm |
| Sample Volume per Vial | 5 mL |
| Reagent Positions | 49 |
| Cuvette Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | Cleverchem 380Plus |
| Sample Capacity | 119 positions (expandable to 129) |
| Reagent Positions | 49 |
| Wavelength Range | 400–900 nm |
| Cuvette Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
| Detection Principle | Photometric Colorimetry (Discrete Flow Analysis) |
| Maximum Throughput | 350 samples/hour |
| Sample Volume Range | 1–900 µL |
| Reagent Volume Range | 1–450 µL |
| Dilution Factor | Up to 100× (in-cuvette) |
| Cuvette Material | Fused Quartz (64-position carousel) |
| Cleaning | 8-step Ultrasonic + WECO Peristaltic Pump System |
| Compliance | ASTM, ISO, EPA, and GB methods |
| Software | GLP-compliant with audit trail, sample/blank correction, and 21 CFR Part 11-ready configuration options |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | CleverChem 380Plus |
| Instrument Type | Laboratory Water Quality Analyzer |
| Analytes | pH, Conductivity, Dissolved Oxygen, Turbidity, Salinity (5-Parameter), Total Nitrogen, Total Phosphorus, Ammonia-N, Nitrate-N, Nitrite-N, Orthophosphate, Silicate, Sulfate, Sulfide, Chloride, Hexavalent Chromium, Alkalinity, Iron, Zinc, Fluoride |
| Compliance | ISO 15681, EPA Methods 353.2/365.2/365.3, AOAC 973.43, AFNOR T90-211, BATF, COFRAC |
| Sample Capacity | 119 positions |
| Detection Principle | Photometric Discrete Chemistry (Endpoint, Kinetic, Differential Time-Based Absorbance) |
| Optical System | Dual-Beam Digital Photometer with Linear Range up to 3.5 Abs |
| Liquid Handling | uL-precision Dispensing with Integrated Needle Wash & Cuvette Integrity Verification |
| Software | CleverControl v5.x with Audit Trail, Electronic Signatures, and 21 CFR Part 11 Compliance Options |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | CleverChem 380Plus |
| Instrument Type | Multi-Parameter Soil Analyzer |
| Sample Capacity | 119 positions |
| Throughput | Up to 350 samples/hour |
| Optical Cell | 64-position quartz cuvette tray, 1 cm pathlength |
| Reagent Positions | 49 (with optional refrigerated storage) |
| Dispensing Range | 1–450 µL (reagents), 1–400 µL (samples) |
| Onboard Dilution | Up to 100× in-cuvette dilution |
| Cleaning | 8-step ultrasonic washing station with optical validation |
| Software | Dual-language (English/Chinese), compliant with GLP audit trail requirements |
| Regulatory Alignment | Methods validated per ISO 11260, ISO 13878, EPA Method 300.0, EPA Method 353.2, and GB/T standards |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | CleverChem 380Plus |
| Measurement Principle | Photometric Discrete Chemistry (Colorimetric Reaction in Quartz Cuvettes) |
| Sample Capacity | 119 positions |
| Reagent Positions | 49 (with optional refrigerated storage) |
| Throughput | Up to 350 samples per hour |
| Optical Cell | 64-position quartz cuvette carousel, 1 cm path length |
| Cleaning | 8-step ultrasonic washing station with optical validation |
| Dilution Capability | On-cuvette dilution up to 100× (1 mL dilutor volume) |
| Software | Dual-language (English/Chinese), supports true sample blank & reagent blank correction |
| Compliance | Methods aligned with GB (People’s Republic of China National Standards), designed for GLP-compliant environments |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Product Type | Discrete Analyzer |
| Wavelength Range | 400–900 nm |
| Sample Volume per Vial | 5 mL |
| Reagent Positions | 49 |
| Cuvette Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | CleverChem Anna |
| Instrument Type | Laboratory-Based Automated Discrete Analyzer |
| Detection Parameters | Total Nitrogen, Total Phosphorus, Ammonia-N, Nitrate, Nitrite, Orthophosphate, Silicate, Sulfate, Sulfide, Chloride, Hexavalent Chromium, Alkalinity, Iron, Zinc, Fluoride |
| Sample Throughput | Up to 200 samples/hour |
| Sample Capacity | 49 positions |
| Reagent Positions | 31 (with optional refrigerated storage) |
| Optical Cell | Reusable 64-position quartz cuvette carousel, 1 cm pathlength |
| Cleaning System | 8-step ultrasonic cuvette cleaning station with optical validation |
| Dilution Capability | In-cuvette dilution up to 100× (1 mL dilutor volume) |
| Software | Dual-language (English/Chinese), supports true sample blank and reagent blank correction |
| Waste Management | Sealed, sensor-monitored waste collection system |
| Compliance | Designed for GLP/GMP environments |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | CleverChem Anna |
| Product Type | Discrete Flow Analyzer |
| Wavelength Range | 400–900 nm |
| Sample Volume per Vial | 5 mL |
| Reagent Positions | 31 |
| Cuvette Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | CleverChem Anna |
| Instrument Type | Multi-Parameter Discrete Analyzer for Soil and Environmental Samples |
| Sample Capacity | 49 positions |
| Throughput | Up to 200 samples per hour |
| Optical Cell | 64-position quartz cuvette tray, 1 cm path length |
| Reagent Positions | 31 (with optional refrigerated storage) |
| Dispensing Range | 1–400 µL (samples), 1–450 µL (reagents) |
| On-board Dilution | Up to 100×, performed directly in cuvette |
| Cleaning | 8-step ultrasonic cuvette cleaning station with optical validation |
| Software | Dual-language (English/Chinese), compliant with GLP data integrity requirements |
| Regulatory Alignment | Methods validated per ISO 11260, ISO 14253, EPA Methods 300.0, 353.2, and GB/T standards for soil testing |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | CleverChem Anna |
| Detection Principle | Automated Segmented Flow Analysis (SFA) with Photometric Detection |
| Sample Throughput | Up to 200 samples/hour |
| Sample Capacity | 49 positions |
| Reagent Positions | 31 (with optional refrigerated storage) |
| Optical Cell | 64-position quartz cuvette carousel, 1 cm path length, reusable |
| Cleaning | 8-step ultrasonic washing station with optical validation |
| Dilution Capability | On-board 1 mL dilutor, up to 100× automatic dilution in cuvette |
| Blank Correction | True sample blank and reagent blank compensation |
| Waste Management | Sealed waste sensing & collection system |
| Software | Dual-language (English/Chinese), compliant with GLP audit trail requirements |
| Regulatory Alignment | Methods validated per China National Tobacco Industry Standards (e.g., YC/T 247–2008, YC/T 160–2002, YC/T 173–2003) |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Instrument Type | Discrete Analyzer (Flow-Based Spectrophotometric Analyzer) |
| Model | CleverChem F.U.V. |
| Wavelength Range | 200–850 nm |
| Sample Volume per Test | 10 mL |
| Reagent Positions | N/A (Reagent-free operation for core wine parameters) |
| Flow Cell Pathlength | 0.20 mm |
| Light Source | Deuterium + Tungsten-Halogen UV/Vis Lamp (2000 h lifetime) |
| FTIR Resolution | < 0.4 cm⁻¹ |
| UV-Vis Spectral Resolution | 0.25 nm |
| Detector | 2048-pixel CCD array (200 × 14 µm/pixel) |
| Temperature Control Range | 5–35 °C |
| Dimensions (Analyzer Unit) | 35 × 28 × 26 cm (W×D×H) |
| Weight | 10 kg |
| Compliance | Designed for GLP-compliant wine laboratories |
| Brand | DeChem-Tech |
|---|---|
| Country of Origin | Germany |
| Model | CleverChem Petro |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Capability | Multi-parameter |
| Analysis Speed | Up to 350 samples/hour |
| Sample Capacity | 119 positions (5 mL tubes) |
| Sample Volume Range | 1–900 µL |
| Reagent Positions | 49 |
| Reagent Volume Range | 1–450 µL |
| Refrigerated Reagent Storage | Yes |
| Cuvette Carousel | 64 positions |
| Cuvette Temperature Control | Ambient to 49.6 °C (standard reaction temperature: 37.00 ± 0.01 °C) |
| Cuvette Cleaning | 8-step automated cycle |
| Detector | 24-bit digital photometer |
| Optical Filters | 9 measurement + 1 reference filter |
| Wavelength Range | 340–880 nm |
| Absorbance Linearity | 0–3.5 Abs |
| Absorbance Resolution | 0.0001 Abs |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | CleverChem Petro |
| Instrument Type | Laboratory-Based Automated Wet-Chemistry Analyzer |
| Detection Parameters | Ammonia-N, Total Nitrogen (TN), Total Phosphorus (TP), Nitrate, Nitrite, Orthophosphate, Silicate, Sulfate, Sulfide, Chloride, Total Phenols, Iron, Zinc, Fluoride, Hexavalent Chromium, Alkalinity |
| Sample Throughput | Up to 350 samples/hour |
| Optical Cell | Reusable 64-position quartz cuvette carousel, 1 cm path length |
| Sample Capacity | 119 positions |
| Reagent Positions | 49 (with optional refrigerated storage) |
| Dilution Capability | In-cuvette dilution up to 100× (1 mL dilutor volume) |
| Cleaning System | 8-step ultrasonic cleaning station with optical validation |
| Waste Management | Sealed waste sensing and collection system |
| Software | Dual-language (English/Chinese) PC-based control and data processing software compliant with GLP audit trails |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | CleverChem-Anna |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Parameters | Nitrate, Nitrite, Ammonia-N, Total Nitrogen, Orthophosphate, Total Phosphorus, Silicate, Sulfate, Sulfide, Chloride, Hexavalent Chromium, Alkalinity, Iron, Zinc, Fluoride, Acidity, Hardness, Manganese, Aluminum, Copper, Magnesium, Cyanide, Phenols, and more |
| Sample Capacity | 49 positions |
| Reagent Positions | 31 (with optional refrigerated storage) |
| Throughput | Up to 200 samples per hour |
| Optical Cell | Reusable 64-position quartz cuvette carousel, 1 cm pathlength |
| Washing Protocol | 7-step automated cleaning with optical validation |
| Software | Dual-language (English/Chinese), supports true sample blanking and reagent blanking |
| Interface | USB |
| Compliance | Designed for ISO 15586, ASTM D3867, EPA 365.4, USP <643>, and GLP/GMP-aligned data integrity workflows |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | MeaChemBox |
| Instrument Type | Portable/HANDHELD Water Quality Analyzer |
| Detection Parameters | Ammonia-N, Nitrate-N, Nitrite-N, Phosphate-P, Silicate-Si, Total Nitrogen (TN), Total Phosphorus (TP), COD (UV), BOD, Turbidity |
| Measurement Principle | Micro Loop Flow Analysis (pLFA) with Automated Colorimetric/Fluorometric Detection |
| Display | 8-inch TFT color touchscreen interface |
| Data Export | USB 2.0 and RS-232 |
| Connectivity | Mobile app-enabled remote result access and reporting |
| Compliance Framework | Designed for field-deployable GLP-aligned operation |