DRETOP TDK-8AS Electrically Heated Constant-Temperature Water Bath
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TDK-8AS |
| Instrument Type | Constant-Temperature Bath |
| Circulation Function | None |
| Temperature Control | Heating-Only |
| Bath Capacity | 12 L |
| Temperature Range | RT+5°C to 100°C |
| Temperature Stability | ±0.5°C |
| Temperature Resolution | 0.1°C |
| Input Power | 1000 W |
| Supply Voltage | AC 220 V, 50 Hz |
Overview
The DRETOP TDK-8AS Electrically Heated Constant-Temperature Water Bath is a precision thermal management instrument engineered for stable, uniform heating in laboratory environments where reproducible temperature control is critical. It operates on resistive immersion heating coupled with microprocessor-based PID feedback regulation—ensuring accurate setpoint maintenance without external circulation. Unlike recirculating baths, the TDK-8AS relies on passive convection and optimized internal geometry to minimize thermal gradients across its 12-liter stainless steel chamber. Its design prioritizes operational safety, long-term reliability, and compatibility with sensitive applications including enzyme incubation, sample equilibration prior to analytical testing (e.g., HPLC vial warming), chemical reaction preheating, and pharmaceutical stability studies requiring sustained temperatures between ambient +5°C and 100°C.
Key Features
- Microprocessor-controlled PID temperature regulation with auto-tuning capability ensures rapid stabilization and minimal overshoot during thermal transitions.
- High-visibility LED display with 0.1°C resolution and programmable timer (1–9999 minutes) supports unattended operation and protocol adherence.
- 304 stainless steel inner tank and lid provide corrosion resistance, ease of cleaning, and compliance with GLP hygiene standards for repeated use with aqueous reagents and biological samples.
- Double-layer insulated housing with water-tight sealing prevents condensation leakage and enhances energy efficiency by reducing heat loss to ambient surroundings.
- Integrated dry-run protection activates immediately at power-on: built-in water-level sensor halts heating if fluid volume falls below safe operational threshold, preventing heater element damage and eliminating fire risk.
- Over-temperature alarm with automatic cut-off triggers when bath temperature exceeds user-defined limit—critical for preserving sample integrity and meeting ISO/IEC 17025 environmental monitoring requirements.
Sample Compatibility & Compliance
The TDK-8AS accommodates standard laboratory glassware including beakers (up to 1000 mL), Erlenmeyer flasks, test tubes, and jacketed reactors with external ports. Its non-circulating architecture avoids mechanical agitation that could compromise fragile suspensions or sedimentation-based assays. For optimal performance and longevity, deionized or distilled water (≥Grade III per ISO 3696) is recommended as the heat-transfer medium; tap water usage requires periodic descaling per ASTM D4193 to prevent scale buildup on the heating element and thermal sensor. The unit conforms to IEC 61010-1:2010 safety standards for electrical equipment used in laboratory settings and supports traceable calibration via external reference thermometers compliant with ISO/IEC 17025 procedures.
Software & Data Management
While the base TDK-8AS model features standalone analog/digital control without embedded data logging, optional RS485 serial interface enables integration into centralized lab management systems. When paired with DRETOP’s proprietary communication software (sold separately), users can remotely monitor real-time bath temperature, initiate/terminate timers, and export timestamped temperature logs for audit trails required under FDA 21 CFR Part 11 and EU Annex 11 regulatory frameworks. Firmware updates are delivered via USB port to ensure continued alignment with evolving cybersecurity and data integrity expectations in GxP environments.
Applications
- Pre-warming reagents and solvents prior to GC, HPLC, or spectrophotometric analysis to eliminate thermal shock-induced baseline drift.
- Controlled dehydration and solvent evaporation in environmental testing labs adhering to EPA Method 5035B protocols.
- Thermal conditioning of polymer solutions before rheological measurement using rotational viscometers.
- Incubation support for microbiological media preparation in clinical and food safety laboratories operating under CLSI M22-A3 guidelines.
- Temperature staging in materials science workflows involving thermal expansion coefficient determination or phase transition observation.
- Supporting ASTM D1500 color rating procedures where standardized sample temperature directly influences visual assessment accuracy.
FAQ
Is the TDK-8AS suitable for use with organic solvents such as ethanol or acetone?
No. This unit is designed exclusively for aqueous media. Organic solvents pose fire hazards and may degrade seals or sensors not rated for chemical exposure.
Can the temperature stability of ±0.5°C be verified independently?
Yes. Users may validate performance using an NIST-traceable calibrated thermometer inserted at multiple locations within the bath—center, corners, and near the heater—to confirm spatial uniformity per ISO 17025 clause 5.10.
Does the TDK-8AS meet CE or UL certification requirements?
It complies with IEC 61010-1:2010 and carries CCC certification for domestic Chinese markets. CE marking is available upon request for export configurations with modified labeling and documentation.
What maintenance intervals are recommended for optimal long-term operation?
Descale the interior every 3 months when using purified water; monthly when using tap water. Inspect water-level sensor functionality quarterly and recalibrate temperature display annually using a certified reference probe.
Is remote monitoring possible without purchasing additional hardware?
Basic remote status checking requires the optional RS485 module and compatible PC interface. Standalone operation does not include Wi-Fi or Ethernet connectivity.