DreTop
Filter
Showing 1–30 of 841 results
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZSH Series |
| Cooling Method | Compressor-based Refrigeration |
| Temperature Range | −10 °C to 90 °C |
| Temperature Setting Resolution | 0.1 °C |
| Temperature Uniformity | ≤1.5 °C |
| Temperature Fluctuation | ±0.5 °C |
| Temperature Accuracy (Deviation) | ±0.6 °C |
| Capacity Options | 70 L to 1500 L |
| Interior Material | 304 Stainless Steel |
| Sensor Configuration | Dual Class A PT100 Sensors |
| Door Monitoring | Unauthorized/Extended-Open Alarm with Audible & Visual Alert |
| Sensor Fault Detection | Real-time Diagnostics for Signal Loss, Drift, or Out-of-Range Readings |
| Communication Interface | Isolated RS485 Port Supporting Modbus RTU and Other Industrial Protocols |
| Data Export | CSV-structured Logs Requiring Dedicated Software Conversion to Excel or PDF |
| User Interface | Full-Color TFT Touchscreen with Dual-Gasket Sealed Door |
| Access Port | Ø50 mm Pass-Through Port |
| Shelf Load Capacity | ≥30 kg per Shelf |
| Optional Features | UV Germicidal Lamp, Thermal Printer Module, Cloud-Based Remote Monitoring System |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Automated Anaerobic Incubator |
| Operating Temperature Range | RT + 3°C to 65°C |
| Temperature Uniformity & Stability | ±0.5°C |
| Oxygen Concentration Range | 0.1–25% (displayable in % or ppm) |
| Chamber Dimensions (W×D×H) | 800 × 690 × 660 mm |
| Gas System | Dry, oil-free vacuum pump |
| Anaerobic Performance | O₂ ≤ 1% achievable |
| Control Interface | Full-color capacitive touchscreen with real-time O₂/temperature display, local atmospheric pressure readout, and touch-activated solenoid valve control |
| Safety Features | Over-temperature alarm (audible/visual), auto power recovery with parameter memory, UV sterilization lamp, 12 mm tempered front window, 304 stainless steel inner chamber |
| Compliance Enablers | Supports GLP/GMP documentation workflows |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Model | ACW-350Pro |
| Instrument Type | Manual Anaerobic Incubator |
| Temperature Range | RT+3°C to 65°C |
| Temperature Uniformity | ±1°C |
| Temperature Stability | ±0.5°C |
| O₂ Concentration Range | 0.1–25% (displayable in % or ppm) |
| Gas Supply | Mixed gas (e.g., 85% N₂ / 5% H₂ / 10% CO₂ or 99.99% N₂) |
| Chamber Dimensions (W×D×H) | 400 × 300 × 280 mm |
| Vacuum Pump | Oil-free dry piston pump |
| Anaerobic Maintenance Time | >12 h after gas supply cessation |
| Viewing Window | 12 mm tempered glass |
| Interior Material | 304 stainless steel |
| Power Supply | 220 V, 50 Hz |
| Input Power | 650 W |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Model | ACW-350Pro |
| Instrument Type | Automated Anaerobic Incubator |
| Temperature Range | RT + 3°C to 65°C |
| Temperature Uniformity & Fluctuation | ±1°C |
| Humidity Control | Natural Evaporation |
| O₂ Concentration Range | 0.1–25% (displayable in % or ppm) |
| Gas Supply Options | Vacuum evacuation, gas purging, mixed gas (85% N₂ / 5% H₂ / 10% CO₂), and ultra-high-purity N₂ (99.99%) |
| Chamber Dimensions (W×D×H) | 800 × 690 × 660 mm |
| Internal Chamber Material | 304 Stainless Steel |
| Viewing Window | 12 mm Tempered Glass |
| Vacuum Pump | Oil-free Dry Piston Pump |
| Power Supply | 220 V, 50 Hz |
| Input Power | 650 W |
| Operating Ambient Pressure Display | Yes |
| Safety Features | Over-temperature alarm, auto power-off on fault, blackout memory function |
| Anaerobic Maintenance Duration | >12 h after cessation of gas replenishment |
| Anaerobic Establishment Time | ≤5 min (pass-through chamber), ≤50 min (main operating chamber) |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Manual Anaerobic Incubator |
| Model | ACW-350Pro-II |
| Temperature Range | RT + 3°C to 65°C |
| Temperature Uniformity | ±1°C |
| Temperature Stability | ±0.5°C |
| O₂ Concentration Range | 0.1–25% (displayable in % or ppm) |
| Gas Supply | Pre-mixed gas (5% H₂ + 10% CO₂ + 85% N₂) |
| Chamber Dimensions (W×D×H) | 800 × 690 × 660 mm |
| Internal Chamber Material | 304 Stainless Steel |
| Viewing Window | 12 mm Tempered Glass |
| Vacuum Pump | Oil-free Dry Diaphragm Pump |
| Power Supply | 220 V, 50 Hz |
| Input Power | 650 W |
| Anaerobic Maintenance Duration | >12 h after gas supply cessation |
| Oxygen Reduction Time (Transfer Chamber) | ≤5 min |
| Oxygen Reduction Time (Main Chamber) | ≤50 min |
| UV Sterilization | Integrated |
| Touchscreen Interface | Full-color capacitive touchscreen with real-time atmospheric pressure display |
| Compliance | Designed for GLP-compliant workflows |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ADC-05-N20 |
| Temperature Range | −20 °C to 100 °C |
| Bath Volume | 5 L |
| Temperature Stability | ±1 °C |
| Flow Rate | 20 L/min |
| Max. Head | 10–12 m |
| Circulation Port | φ10 mm stainless steel metal hose with bayonet fitting |
| Control Mode | 99-segment programmable linear ramp/soak |
| Power Supply | 220 V, 50 Hz |
| IP Rating | IP54 |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | AFZ6-1000 |
| Instrument Type | Tumbling Shaker |
| Timer Range | 0–9999 min |
| Oscillation Frequency | 0–300 cycles/min |
| Temperature Control Range | RT+5°C to 60°C |
| Capacity | 6 × 1000 mL flasks |
| Compliance | HJ/T 299–2007 & HJ/T 300–2007 |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Manual Anaerobic Incubator |
| Temperature Range | RT + 3°C to 52°C |
| Temperature Uniformity & Fluctuation | ±0.3°C |
| Humidity Range | 20–90% RH |
| O₂ Concentration Range | 0–100% |
| Gas Supply | Anaerobic gas mixture (80% N₂, 10% CO₂, 10% H₂) and pure N₂ |
| Chamber Dimensions (W×D×H) | 490 × 760 × 530 mm |
| O₂ Detection Resolution | 0.1% |
| O₂ Control Accuracy | ±0.1% |
| Catalyst Lifetime | >3 years without thermal activation |
| Anaerobic Equilibration Time | ≤30 min to ≤5 ppm O₂ |
| Transfer Lock Capacity | 6 L chamber (supports 22 × 90 mm Petri dishes or 3 × 500 mL screw-cap bottles) |
| UV Sterilization | 254 nm integrated lamp with programmable timing |
| Filtration | HEPA-grade air filtration system |
| Data Logging | 45-day internal history storage with USB export capability |
| Safety Interlocks | Dual-door pneumatic seal with vacuum-assisted gasket, mechanical/electronic interlock logic |
| Validation Interface | Standardized 4–20 mA / RS485 ports for third-party probe integration |
| Operating System | Bilingual (Simplified Chinese & English), three-tier user permission management |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | AVP-12 |
| Instrument Type | Rotary Vane Pump |
| Product Type | Oil-Lubricated Pump |
| Pumping Speed | 12 m³/h (3.33 L/s) |
| Ultimate Vacuum | ≤0.4 Pa (base pressure) |
| Operating Vacuum Range | 15–133 Pa (when integrated with DRETOP vacuum chambers) |
| External Dimensions | 505 × 162 × 254 mm |
| Motor Power | 550 W |
| Rated Voltage | 220 V, 50 Hz (380 V optional) |
| Rotational Speed | 1440 rpm |
| Oil Capacity | 1.2 L |
| Inlet/Outlet Port | KF-25 |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Box-Type Muffle Furnace |
| Max Temperature | 1600 °C |
| Temperature Control Accuracy | ±1 °C |
| Max Power | 12 kW |
| Time to Max Temperature | 70 min |
| Heating Element | Silicon-Molybdenum (MoSi₂) Rods |
| Internal Chamber Dimensions | 200 × 300 × 200 mm |
| Nominal Volume | 12 L |
| Control System | 7-inch Color Touchscreen Controller with AI-based PID Algorithm |
| Transformer | Integrated Three-Phase Dry-Type Isolation Transformer |
| Safety Features | Dual-stage Overtemperature Protection, Door-Interlocked Power Cut-off, Power Failure Memory, Phase Loss & Thermocouple Break Detection |
| Insulation | Vacuum-Microporous Ceramic Fiber Board |
| Chamber Lining | Polycrystalline Alumina Fiber |
| Voltage | AC 380 V, 50 Hz |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Model | B16-36AI |
| Type | Box-Type Muffle Furnace |
| Max. Operating Temperature | 1600 °C |
| Rated Power | 15 kW |
| Internal Chamber Dimensions | 300 × 400 × 300 mm (W × H × D) |
| Nominal Volume | 36 L |
| Heating Element | Silicon-Molybdenum (MoSi₂) Rods |
| Temperature Control System | AI-Powered Digital Controller with 7-inch Color Touchscreen |
| Programmable Ramp/Soak Profiles | Multi-segment (up to 30 segments), Linear & Non-linear Fitting Algorithms |
| Thermal Insulation | Vacuum-Microporous Ceramic Fiber Board |
| Safety Features | Dual-stage Overtemperature Protection, Door-Interlocked Power Cut-off, Phase Loss & Thermocouple Break Detection, Power Segment Limitation, Blackout Memory Retention |
| Compliance | Designed for GLP-compliant thermal processing |
| Optional Accessories | Exhaust Chimney, RS485 Communication Module, Inert Gas Inlet Valve, 4G Crucible Kit, Miniature Thermal Printer |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Box-Type Muffle Furnace |
| Maximum Temperature | 1600 °C |
| Temperature Control Accuracy | ±1 °C |
| Rated Power | 15 kW |
| Heating Time to Max Temp | 70 min |
| Heating Element | Silicon-Molybdenum (MoSi₂) Rods |
| Internal Chamber Dimensions | 300 × 400 × 300 mm |
| Nominal Volume | 36 L |
| Control System | 7-inch Color Touchscreen Controller with AI-based PID Algorithm |
| Safety Features | Dual-stage Overtemperature Protection, Door-Interlocked Power Cut-off, Power Failure Memory, Phase Loss & Thermocouple Break Detection |
| Insulation | Vacuum-Microporous Ceramic Fiber Board |
| Chamber Lining | Polycrystalline Alumina Fiber |
| Transformer | Three-Phase Dry-Type Isolation Transformer |
| Compliance | Designed for GLP/GMP-aligned lab environments |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Model | B16-5AI |
| Type | Box-Type Muffle Furnace |
| Max Temperature | 1600 °C |
| Temperature Control Accuracy | ±1 °C |
| Rated Power | 8000 W |
| Heating Rate | 25–35 °C/min (reaches 1600 °C in ~40 min) |
| Heating Element | Silicon Molybdenum (MoSi₂) Rods |
| Internal Chamber Dimensions | 150 × 300 × 120 mm |
| Nominal Volume | 5 L |
| Control Interface | 7-inch Color Touchscreen |
| Transformer | Integrated Three-Phase Dry-Type Isolation Transformer |
| Compliance | Designed for GLP-compliant thermal processing environments |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | B16-5P |
| Instrument Type | Box-Type Muffle Furnace |
| Maximum Temperature | 1600°C |
| Temperature Control Accuracy | ±1°C |
| Rated Power | 8 kW |
| Time to Max Temperature | 70 min |
| Heating Element | Silicon Molybdenum (MoSi₂) Rods |
| Internal Chamber Dimensions | 150 × 300 × 120 mm (W × D × H) |
| Control System | Microcomputer-Based PID Controller |
| Nominal Volume | 5 L |
| Tube Diameter | Not applicable (box-type furnace) |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | B16-9AI |
| Instrument Type | Box-Type Muffle Furnace |
| Maximum Temperature | 1600 °C |
| Temperature Control Accuracy | ±1 °C |
| Rated Power | 10 kW |
| Heating Time to Max Temp | 70 min |
| Heating Element | Silicon-Molybdenum (MoSi₂) Rods |
| Internal Chamber Dimensions | 200 × 300 × 150 mm |
| Control Interface | 7-inch Color Touchscreen Controller |
| Nominal Volume | 9 L |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Box-Type Muffle Furnace |
| Model | B18-12P |
| Maximum Temperature | 1800 °C |
| Temperature Control Accuracy | ±1 °C |
| Rated Power | 15 kW |
| Heating Time to Max Temp | 70 min |
| Heating Element | Silicon Molybdenum (MoSi₂) Rods |
| Internal Chamber Dimensions | 200 × 300 × 200 mm |
| Nominal Volume | 12 L |
| Control System | Programmable Digital Controller with Color Touchscreen Interface |
| Insulation Material | Vacuum-Microporous Ceramic Fiber Board |
| Chamber Lining | Polycrystalline Alumina Fiber |
| Transformer | Integrated Three-Phase Dry-Type Isolation Transformer |
| Safety Features | Dual-Stage Overtemperature Protection, Door-Interlocked Power Cut-off, Power Failure Memory, Phase Loss & Thermocouple Break Detection |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Model | B18-36AI |
| Type | Box-Type Muffle Furnace |
| Max. Temperature | 1800 °C |
| Temperature Control Accuracy | ±1 °C |
| Rated Power | 30 kW |
| Heating Time to Max. Temp. | ≤60 min |
| Heating Element | Silicon-Molybdenum (MoSi₂) Rods |
| Internal Chamber Dimensions | 300 × 400 × 300 mm (W × D × H) |
| Nominal Volume | 36 L |
| Control System | AI-Based Programmable Controller with 7″ Color Touchscreen |
| Insulation Material | Vacuum-Microporous Ceramic Fiber Board |
| Heating Configuration | Triple-Wall Radiant Heating (Front, Back, Top Walls) |
| Safety Features | Dual-Stage Over-Temperature Protection, Door-Interlocked Power Cut-off, Power Segment Limitation, Power-Fail Memory Retention, Phase-Loss & Thermocouple Break Detection |
| Transformer | Integrated Three-Phase Dry-Type Isolation Transformer |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Box-Type Muffle Furnace |
| Maximum Temperature | 1800 °C |
| Temperature Control Accuracy | ±1 °C |
| Rated Power | 18 kW |
| Heating Time to Max Temperature | 70 min |
| Heating Element | Silicon-Molybdenum Rods (MoSi₂) |
| Internal Chamber Dimensions | 300 × 400 × 300 mm |
| Nominal Volume | 36 L |
| Control Interface | 7-inch Full-Color Touchscreen HMI |
| Electrical Supply | AC 380 V, 50 Hz |
| Transformer | Built-in Three-Phase Dry-Type Isolation Transformer |
| Insulation Material | Vacuum-Microporous Ceramic Fiber Board |
| Chamber Lining | Polycrystalline Alumina Fiber |
| Safety Features | Dual-Stage Overtemperature Protection, Door-Interlocked Power Cut-off, Power Failure Memory, Phase Loss & Thermocouple Break Detection |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Product Type | Box-Type Muffle Furnace |
| Model | B18-9AI |
| Max Temperature | 1800 °C |
| Temperature Control Accuracy | ±1 °C |
| Max Power | 12 kW |
| Heating Time to Max Temp | 70 min |
| Heating Element | Silicon-Molybdenum Rod (MoSi₂) |
| Internal Chamber Dimensions | 200 × 300 × 150 mm |
| Nominal Volume | 9 L |
| Control Interface | 7-inch Color Touchscreen HMI |
| Transformer | Built-in Three-Phase Dry-Type Isolation Transformer |
| Compliance | Designed for GLP/GMP-aligned lab environments |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BD6-100 |
| Instrument Type | Laboratory BOD Analyzer |
| Measurement Principle | Manometric (Pressure-Difference) Method |
| Measurement Range | 0–4000 mg/L |
| Detection Limit | 1 mg/L |
| Accuracy | ±8% |
| Incubation Temperature | 20 °C ±1 °C |
| Temperature Control Range | 0–65 °C |
| Temperature Uniformity | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Sample Capacity | 6 independent channels |
| BOD Vial Volume | 580 mL |
| Data Storage Duration | 10 years |
| Battery Life | ≥2 years |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 480 × 390 × 780 mm |
| Shelf Configuration | 3 adjustable stainless-steel shelves |
| Optional Accessories | RS485 interface, 25 mm test port, USB port |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BD6-150-XII |
| Instrument Type | Laboratory BOD Analyzer |
| Measurement Principle | Manometric (Pressure-Difference) Method |
| Measurement Range | 0–4000 mg/L |
| Detection Limit | 1 mg/L |
| Accuracy | ±8% |
| Incubation Temperature | 20 °C ±1 °C |
| Resolution | 0.01 mg/L |
| Temperature Control Range | 0–65 °C |
| Temperature Uniformity | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Incubation Chamber Dimensions (W×D×H) | 480 × 390 × 780 mm |
| Sample Capacity | Up to 6 independent BOD bottles (580 mL each) |
| Data Storage Duration | 10 years |
| Battery Life | ≥2 years |
| Power Supply | AC 220 V, 50 Hz |
| Optional Interfaces | RS485, USB, 25 mm test port |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | BD6-70 |
| Instrument Type | Laboratory BOD Analyzer |
| Measurement Principle | Manometric (Pressure-Difference) Method |
| Measurement Range | 0–4000 mg/L |
| Accuracy | ±8% |
| Single-Sample Test Duration | 1–30 days |
| Incubation Temperature | 20 °C ±1 °C |
| Resolution | 0.01 mg/L |
| Data Storage Capacity | 10 years |
| Battery Life | ≥2 years |
| Temperature Control Range | 0–65 °C |
| Temperature Uniformity | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Chamber Dimensions (W×D×H) | 450×320×500 mm |
| BOD Vial Capacity | 580 mL |
| Number of Independent BOD Channels | 6 |
| Built-in Stirring Function | Yes |
| Direct Digital Readout | Yes |
| Optional Interfaces | RS485, USB, 25 mm Test Port |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Model | BD6-70 |
| Instrument Type | Laboratory BOD Analyzer |
| Principle | Mercury-Free Pressure-Difference Method (Dissolved Oxygen Depletion) |
| Incubation Temperature Range | 0–65 °C |
| BOD Measurement Range | 0–4000 mg/L |
| Resolution | 0.01 mg/L |
| Accuracy | ±8% |
| Temperature Uniformity | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Max. Sample Channels | 6 |
| Incubation Chamber Dimensions (W×D×H) | 450 × 320 × 500 mm |
| Data Storage Duration | 10 years |
| Battery Life | ≥2 years |
| Power Supply | AC 220 V, 50 Hz |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | BD6-70E |
| Price Range | USD 4,200 – 7,000 |
| Instrument Type | Laboratory BOD Analyzer |
| Measurement Range | 0–4000 mg/L |
| Detection Limit | 1 mg/L |
| Accuracy | ±8% |
| Single-Sample Incubation Duration | 1–30 days |
| Incubation Temperature | 20 °C ±1 °C |
| Resolution | 0.01 mg/L |
| Temperature Stability | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Sample Capacity | 6 independent channels |
| Cultivation Vessel Volume | 580 mL |
| Data Storage Duration | 10 years |
| Battery Life | ≥2 years |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 450×320×500 mm |
| Shelf Quantity | 2 adjustable stainless-steel shelves |
| Communication Interface | RS485 (optional), USB (optional), Bluetooth data upload & print (standard) |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Model | BD6-70E |
| Instrument Type | Laboratory BOD Analyzer |
| Principle | Manometric (Pressure-Difference) Method |
| Temperature Range | 0–65 °C |
| BOD Measurement Range | 0–4000 mg/L |
| Accuracy | ±8% |
| Incubation Temperature Setting | 20 °C ±1 °C |
| Temperature Uniformity | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| BOD Resolution | 0.01 mg/L |
| Test Duration | 1–30 days |
| Sample Capacity | 6 independent channels |
| Data Storage Duration | 10 years |
| Battery Life | ≥2 years |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 450×320×500 mm (chamber), 275×185×75 mm (analyzer unit) |
| Internal Chamber Material | Mirror-finish stainless steel |
| Door Seal | Magnetic gasket |
| Control System | Microprocessor-based 30-segment programmable controller |
| Communication Options | RS485 (optional), USB (optional), Bluetooth data export (standard on BD6-70E) |
| Compliance | Designed for ASTM D5210, ISO 5815-1, and EPA Method 405.1 workflows |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BGMH-1000 |
| Temperature Range | 0–65 °C |
| Temperature Uniformity | ±2.5 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Range | 30–95 %RH (customizable to 20–95 %RH) |
| Humidity Deviation | ±3 %RH |
| Illumination Range | 0–25,000 lx (optional) |
| Internal Volume | 1000 L |
| Power Supply | AC 380 V, 50 Hz |
| Input Power | 7500 W |
| Chamber Dimensions (W×D×H) | 900×580×1600 mm |
| Shelving | 4 adjustable stainless-steel shelves |
| Control Interface | 7-inch color touchscreen with multi-level user permissions |
| Data Logging | 60-second interval, ≥3 years continuous storage |
| Compliance Support | IQ/OQ/PQ documentation, CNAS calibration certificates (at user-specified temp/humidity points), optional FDA 21 CFR Part 11–compliant software module |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BGMH-150 |
| Voltage | AC 220 V / 50 Hz |
| Temperature Range | 0–65 °C |
| Temperature Uniformity | ±2.5 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Range | 30–95 %RH (customizable to 20–95 %RH) |
| Humidity Deviation | ±3 %RH |
| Illumination Range | 0–25,000 lx (optional) |
| Internal Volume | 150 L |
| Inner Chamber Dimensions (W×D×H) | 500 × 400 × 750 mm |
| Power Consumption | 2.2 kW |
| Programmable Stages | 100 per program, up to 1,000 programs |
| Data Logging Interval | 60 s (≥3 years continuous storage) |
| Compliance | Designed for ICH Q1A–Q1E, USP <1151>, ISO 14644-1 (Class 8), and GMP-aligned 3Q validation (IQ/OQ/PQ) |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BGMH-250 |
| Temperature Range | 0–65 °C |
| Temperature Uniformity | ±2.5 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Range | 30–95 %RH (customizable to 20–95 %RH) |
| Humidity Deviation | ±3 %RH |
| Illumination Range | 0–25,000 lx (optional) |
| Internal Volume | 250 L |
| Power Supply | AC 220 V / 50 Hz |
| Input Power | 2400 W |
| Control Interface | Color TFT Touchscreen |
| Programmable Steps | 100 segments per program × 100 programs |
| Data Logging Interval | 60 s (≥3 years continuous storage) |
| Compliance Support | IQ/OQ/PQ documentation, CNAS calibration certificate available |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BMH-800 |
| Price Range | USD 9,500 – 13,600 (FOB Shanghai) |
| Temperature Control Range | 0–65 °C |
| Temperature Uniformity | ±2.5 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Control Range | 30–95 %RH (customizable to 20–95 %RH) |
| Humidity Deviation | ±3 %RH |
| Illumination Capability | Optional (0–25,000 lx, LED-based, adjustable) |
| Internal Volume | 800 L |
| Power Supply | AC 380 V, 50 Hz |
| Input Power | 7,000 W |
| Chamber Dimensions (W×D×H) | 965 × 580 × 1430 mm |
| Standard Shelving | 4 adjustable stainless steel shelves |
| Data Logging Interval | 60 s (≥3 years continuous storage) |
| Compliance Support | IQ/OQ/PQ documentation, CNAS traceable calibration points (e.g., 0 °C, 60 °C, 121 °C |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Model | BOD-100CP-VI |
| Instrument Type | Laboratory BOD Analyzer & Incubator |
| Principle | Manometric Pressure-Difference Method |
| Measurement Range | 0–4000 mg/L |
| Detection Limit | 1 mg/L |
| Accuracy | ±8% |
| Temperature Control Range | 0–65 °C |
| Temperature Uniformity | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Incubation Temperature Setpoint | 20 °C ±1 °C |
| Sample Capacity (Incubator) | 450 × 380 × 590 mm (W×D×H) |
| Independent Test Channels | Up to 6 |
| Data Storage Duration | 10 years |
| RS485 Interface | Yes |
| Built-in Power Outlet & 25 mm Test Port | Yes |
| Auto Temperature Compensation | Yes |
| Real-time Curve Logging & Export | Yes |
| Data Upload Capability | Yes |
| Battery Backup | Yes |
| Programmable Stages | 30-segment microprocessor controller |
