Empowering Scientific Discovery

GDYS-103SN Portable Hydrogen Sulfide Water Quality Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Jilin University Xiaotian’e
Origin Jilin, China
Manufacturer Type Direct Manufacturer
Country of Origin China
Model GDYS-103SN
Instrument Type Portable/Handheld Water Quality Analyzer
Target Analyte Hydrogen Sulfide (H₂S)
Detection Limit 0.01 mg/L
Measurement Range 0.00–1.00 mg/L
Accuracy ±5% of full scale
Analysis Time ≤20 minutes per sample
Reagent Format Single-use, pre-packaged test kit

Overview

The GDYS-103SN Portable Hydrogen Sulfide Water Quality Analyzer is an engineered field-deployable instrument designed for rapid, on-site quantification of dissolved hydrogen sulfide (H₂S) in freshwater, wastewater, groundwater, and surface water samples. It operates on the principle of colorimetric analysis via N,N-dimethyl-p-phenylenediamine (DMPD) oxidation—where H₂S reacts under acidic conditions to form methylene blue, a stable chromophore with absorbance peak at 670 nm. This method complies with established wet-chemistry protocols referenced in APHA Standard Methods 4500-S²⁻ F and ISO 10585:1991 (Water quality — Determination of sulfide — Spectrophotometric method). The analyzer integrates a precision LED-based photometer, calibrated optical path, and temperature-compensated detection circuitry to ensure reproducible results under variable ambient conditions (10–35 °C, <85% RH non-condensing).

Key Features

  • Field-ready portable design with integrated rechargeable lithium-ion battery (≥8 hours continuous operation)
  • Dedicated single-use reagent kits pre-aliquoted and vacuum-sealed to eliminate calibration drift and cross-contamination
  • Optimized reaction chamber geometry enabling complete color development within 20 minutes—no external heating or shaking required
  • Onboard microprocessor with linear regression algorithm for automatic concentration calculation from absorbance data
  • Backlit LCD display with intuitive icon-driven interface supporting English-language menu navigation
  • Non-volatile memory storing up to 500 measurement records with timestamp, operator ID, and location tag (via optional Bluetooth GPS module)
  • Rugged IP65-rated enclosure resistant to dust ingress and incidental water splashing during outdoor deployment

Sample Compatibility & Compliance

The GDYS-103SN accepts raw, unfiltered aqueous samples with turbidity ≤100 NTU and total suspended solids (TSS) 0.5 mg/L) may interfere and require pretreatment per manufacturer’s interference mitigation protocol. The instrument conforms to general performance requirements outlined in ISO/IEC 17025:2017 for field testing equipment and supports documentation traceability aligned with GLP principles. While not certified for regulatory reporting under US EPA Method 376.1 or ASTM D4129, it serves as a validated screening tool for preliminary compliance assessment, process monitoring, and emergency response triage.

Software & Data Management

Data export is supported via USB-C interface to standard Windows/macOS systems using included GDYS DataLink software (v3.2+). The application enables batch report generation in PDF/CSV formats compliant with internal QA/QC workflows. Audit trail functionality logs all user actions—including calibration events, firmware updates, and result edits—with immutable timestamps. Optional cloud synchronization (via secure HTTPS API) allows centralized data aggregation across multi-site operations while maintaining data sovereignty per GDPR and local data residency regulations.

Applications

  • Real-time monitoring of H₂S in municipal wastewater collection systems and lift stations
  • Field verification of odor control chemical dosing efficacy at treatment plants
  • Environmental site assessments for contaminated sediments or landfill leachate
  • Drinking water source surveillance in rural distribution networks
  • Educational laboratory instruction for environmental chemistry and analytical method validation
  • Emergency response during industrial spills involving sulfur-containing compounds

FAQ

What sample volume is required for analysis?
A 10.0 mL aliquot of well-mixed water sample is required per test.
Can the instrument measure H₂S in seawater?
No—high chloride ion concentration causes significant interference; use only in freshwater or low-salinity effluents (<500 mg/L Cl⁻).
Is periodic recalibration necessary?
Yes—factory calibration is valid for 12 months; users must perform zero-point verification before each sampling session using deionized water blank.
Are reagent kits supplied with expiration tracking?
Yes—each kit includes printed lot number and expiry date; shelf life is 18 months when stored at 2–8 °C in original packaging.
Does the device meet any international electrical safety standards?
It complies with IEC 61010-1:2010 for electrical safety of laboratory equipment and carries CE marking for EMC Directive 2014/30/EU.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0