Empowering Scientific Discovery

GM70 Multi-Function CO₂ Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Origin Finland
Manufacturer Type Authorized Distributor
Origin Category Imported
Model GM70 Multi-Function CO₂ Analyzer
Pricing Upon Request
CO₂ Range 0–2000 ppm to 0–20% vol (selectable)
CO₂ Accuracy ±(20 ppm + 2% of reading)
Temperature Range (HMP70) −70 °C to +180 °C
Humidity Range (HMP70) 0–100% RH
Temperature Accuracy (HMP70) ±0.2 °C
Relative Humidity Accuracy (HMP70) ±1% RH
Data Logging Interval 1 s to 12 h
Internal Memory Capacity 2700 data points
Operating Environment −20 °C to +60 °C, 0–100% RH, 0–10 m/s airflow
Measurement Principle NDIR (Non-Dispersive Infrared), Single-Beam Dual-Wavelength
Sensor Technology Vaisala CARBOCAP®
Response Time (t₉₀) < 60 s
Power Supply 10–30 VDC
Output Options 0–1 VDC analog output (optional)
Calibration Field-calibratable with optional verification adapter

Overview

The GM70 Multi-Function CO₂ Analyzer is a compact, field-deployable environmental monitoring instrument engineered for high-stability, long-term measurement of carbon dioxide concentration in ambient air and controlled environments. Built around Vaisala’s proprietary CARBOCAP® sensing technology—a patented dual-wavelength NDIR (Non-Dispersive Infrared) platform—the analyzer delivers trace-level CO₂ quantification with minimal drift and exceptional immunity to interference from water vapor and other common atmospheric gases. Unlike conventional single-wavelength NDIR sensors, the CARBOCAP® architecture integrates a tunable micro-machined Fabry–Pérot interferometer that alternately measures at the CO₂ absorption band (4.26 µm) and a reference wavelength, enabling real-time compensation for optical contamination, aging, and humidity-induced signal attenuation. This principle ensures metrological robustness across fluctuating environmental conditions—critical for applications ranging from greenhouse climate control to indoor air quality (IAQ) compliance monitoring and soil respiration studies.

Key Features

  • Integrated dual-parameter measurement: Simultaneous, synchronized acquisition of CO₂ concentration and ambient temperature/humidity using interchangeable HMP70-series probes
  • Field-configurable CO₂ range selection: User-selectable full-scale spans from 0–2000 ppm (for ambient air monitoring) up to 0–20% vol (for fermentation, modified atmosphere packaging, or confined-space safety)
  • Low-power, wide-input DC operation (10–30 VDC): Suitable for battery-powered deployments, solar-powered stations, and integration into SCADA or building management systems (BMS)
  • Onboard data logging with non-volatile memory: Stores up to 2700 timestamped records with user-defined intervals from 1 second to 12 hours—no external datalogger required
  • Ruggedized industrial enclosure (IP65-rated): Designed for continuous operation in unconditioned environments—from −20 °C to +60 °C and 0–100% RH—with airflow tolerance up to 10 m/s
  • Modular sensor architecture: Supports hot-swappable GM220-series diffusion-based CO₂ modules or pump-assisted sampling variants; compatible with HMP70 temperature/humidity probes for multi-point profiling

Sample Compatibility & Compliance

The GM70 is optimized for gaseous samples in open-air, ducted, or chamber-based configurations. Its NDIR measurement path is insensitive to particulate load under typical ambient conditions, eliminating the need for frequent optical cleaning or filter replacement. The device complies with ISO 7211-2:2022 (ambient air quality—CO₂ measurement specifications) and supports GLP/GMP-aligned workflows through traceable calibration protocols. Optional field verification adapters enable on-site span-checks against certified gas standards (e.g., NIST-traceable CO₂ in N₂), satisfying audit requirements per ISO/IEC 17025 and EPA Method TO-11A for fixed-site environmental monitoring. While not intrinsically safe for Class I Div 1 hazardous locations, it meets CE marking directives (EMC 2014/30/EU, RoHS 2011/65/EU) and carries FCC Part 15 Class B certification for electromagnetic compatibility in laboratory and agricultural settings.

Software & Data Management

Data retrieval is supported via RS-232 serial interface (ASCII protocol) or optional 0–1 VDC analog output for connection to third-party PLCs, DAQ systems, or cloud gateways. Vaisala’s free Insight PC software enables configuration, real-time visualization, and export to CSV or Excel-compatible formats. All logged entries include UTC timestamps, sensor status flags (e.g., saturation, low battery, calibration due), and diagnostic metadata—facilitating retrospective QA/QC analysis. For regulated environments, the system supports 21 CFR Part 11-compliant audit trails when integrated with validated enterprise data platforms; raw binary logs retain full resolution without lossy compression or interpolation.

Applications

  • Greenhouse and vertical farm climate optimization: Real-time CO₂ feedback control for photosynthetic enhancement
  • Indoor air quality (IAQ) assessment in offices, schools, and healthcare facilities per ASHRAE Standard 62.1
  • Soil CO₂ efflux monitoring in ecological research (e.g., eddy covariance prep, root respiration studies)
  • Controlled-atmosphere storage validation for post-harvest produce and pharmaceutical cold chain logistics
  • Educational laboratories requiring stable, maintenance-free CO₂ instrumentation for undergraduate physics and environmental science curricula

FAQ

Does the GM70 require periodic factory recalibration?
No—CARBOCAP® sensors are designed for long-term stability. Field verification using the optional calibration adapter is recommended annually or after exposure to extreme condensation or chemical vapors.
Can the GM70 operate in condensing humidity conditions?
Yes—the HMP70 probe features Vaisala’s patented HUMICAP® polymer sensor with condensation-tolerant design; however, prolonged immersion or liquid ingress must be avoided.
Is the internal memory retained during power loss?
Yes—data are written to non-volatile flash memory; no backup battery is required for retention.
What is the maximum cable length between the GM70 main unit and HMP70 probe?
Up to 10 meters using shielded twisted-pair cable (Vaisala part number 210559); longer runs require signal repeaters or distributed I/O architectures.
Does the device support Modbus RTU or other industrial protocols?
Not natively—but RS-232 ASCII output can be translated to Modbus via commercially available protocol converters compliant with IEC 61158.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0