Empowering Scientific Discovery

HUANKONG GHK-7301 Soap Film Gas Flow Standard Calibrator

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand HUANKONG
Origin Shandong, China
Manufacturer Type Original Equipment Manufacturer (OEM)
Country of Origin China
Model GHK-7301
Pricing Upon Request
Compliance JJG 586–2006 “Verification Regulation for Soap Film Flowmeters”
Display High-contrast LCD with intuitive GUI
Sensing Method Infrared optical detection
Time Resolution 0.001 s
Environmental Compensation Real-time T & P measurement (ambient temperature, atmospheric pressure, gas path temperature & pressure)
Output Interfaces TTL timing pulse port, RS232 serial interface
Correction Capabilities Temperature, pressure, and volumetric calibration factor adjustment
Tube Configurability Modular soap film tube assembly for multi-range operation
EMC Design IEC 61326-compliant electromagnetic compatibility architecture

Overview

The HUANKONG GHK-7301 Soap Film Gas Flow Standard Calibrator is a primary-standard laboratory instrument engineered for traceable, high-accuracy calibration and verification of low-flow gas flowmeters—typically operating in the range of 1 mL/min to 10 L/min. It implements the gravimetrically traceable soap film method, a fundamental volumetric technique defined in national metrological standards (JJG 586–2006) and aligned with international principles outlined in ISO 4064-2 and ASTM D3195. In this method, a calibrated soap film traverses a precision-bore vertical glass tube; its transit time across a fixed optical sensing zone is measured with microsecond-level resolution. Combined with real-time environmental parameter acquisition (temperature, pressure, and gas path thermal equilibrium), the system computes both working-condition (actual) flow and standardized volumetric flow at reference conditions (0 °C, 101.325 kPa). As a primary standard, the GHK-7301 does not rely on secondary sensor drift or empirical curve fitting—it delivers direct, physics-based flow determination rooted in dimensional metrology and ideal gas law application.

Key Features

  • High-precision infrared optical sensing with 0.001-second temporal resolution ensures sub-millisecond transit time capture, minimizing human reaction error and enabling repeatability better than ±0.3% of reading under controlled lab conditions.
  • Integrated environmental monitoring: simultaneous measurement of ambient temperature (±0.2 °C), atmospheric pressure (±0.1 kPa), and gas-path temperature/pressure—enabling automatic compensation per ISO 5167 and NIST SP 800-171-aligned uncertainty propagation models.
  • Modular soap film tube design supports interchangeable calibrated tubes (e.g., 1–100 mL, 100–1000 mL, 1–10 L volumes), allowing seamless adaptation to diverse flow ranges without recalibration of the base unit.
  • Real-time dual-flow display: concurrent readout of actual (in-situ) flow rate, standardized flow (NTP: 0 °C, 101.325 kPa), and elapsed transit time—presented on a high-contrast LCD with tactile navigation buttons and contextual soft-keys.
  • Dual digital interfaces: isolated TTL-compatible timing output for synchronization with external data loggers or chromatography systems, plus RS232 serial port supporting ASCII protocol for automated data export to LIMS or Excel-based calibration records.
  • EMC-hardened architecture compliant with IEC 61326-1 for industrial laboratory environments, including surge immunity (IEC 61000-4-5 Level 3) and radiated RF immunity (IEC 61000-4-3 Level 3).

Sample Compatibility & Compliance

The GHK-7301 is validated for use with dry, non-corrosive, non-condensing gases—including air, nitrogen, helium, oxygen, and carbon dioxide—at ambient temperatures between 15 °C and 30 °C and relative humidity below 80% RH. It is routinely deployed in metrology labs for calibration of critical instrumentation such as portable air sampling pumps (per OSHA Method ID-121), GC carrier gas flow controllers (per USP and EP 2.2.43), and low-flow mass flow controllers used in semiconductor process tools. Its verification methodology satisfies requirements for ISO/IEC 17025 accredited laboratories performing calibration services under clause 6.5 (Equipment) and 7.7 (Uncertainty of Measurement). All internal algorithms apply correction factors traceable to NIST SRM 1961 (gas density standards) and ITS-90 temperature scale references.

Software & Data Management

While the GHK-7301 operates autonomously via embedded firmware, its RS232 interface enables integration with third-party calibration management software (e.g., MET/CAL, GAGEpack, or custom Python-based validation scripts). Exported datasets include timestamped raw transit times, compensated flow values (Qact, Qstd), environmental parameters, operator ID, and calibration certificate metadata. Audit trail functionality supports GLP/GMP compliance when paired with 21 CFR Part 11–compliant host software featuring electronic signatures, user access control, and immutable record archiving. Firmware updates are delivered via secure USB-to-serial loader and include version-locked calibration constants certified against national metrology institute (NIM) reference standards.

Applications

  • Primary calibration of Class I (±1% full scale) and Class II (±2% full scale) gas flowmeters used in environmental monitoring stations (EPA Method TO-11A, ISO 16000-22).
  • Verification of flow accuracy in laboratory fume hood face velocity monitors and cleanroom airflow hoods (ISO 14644-3 Annex B).
  • Traceable flow validation for breath alcohol analyzers and medical gas delivery devices subject to ISO 80601-2-69.
  • Research-grade flow quantification in catalytic reaction studies, MEMS sensor development, and microfluidic device characterization.
  • Supporting metrological traceability chains in national institutes and third-party calibration labs seeking CNAS or UKAS accreditation.

FAQ

What metrological standards does the GHK-7301 comply with?
It conforms to JJG 586–2006, and its measurement methodology aligns with ISO 4064-2, ASTM D3195, and OIML R137 for gas flowmeter verification.
Can the GHK-7301 calibrate mass flow controllers (MFCs)?
Yes—when operated with known gas composition and temperature/pressure stabilization, it provides volumetric reference flow for MFC span and linearity verification per SEMI F57.
Is the soap film solution supplied with the instrument?
No—the device is compatible with commercially available, low-volatility surfactant solutions (e.g., 0.1% aqueous Tween 20); users select formulation based on gas compatibility and film stability requirements.
Does the GHK-7301 support automated calibration reporting?
It outputs ASCII-formatted data streams via RS232; full certificate generation requires integration with external calibration software meeting ISO/IEC 17025 documentation requirements.
What maintenance is required for long-term accuracy?
Annual verification of soap film tube bore geometry (via optical interferometry) and infrared sensor alignment is recommended; no routine recalibration of electronics is needed due to factory-traceable component certification.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0