Empowering Scientific Discovery

IKA VACSTAR lite Starter Plus Solution Diaphragm Vacuum Pump

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand IKA
Origin Germany
Manufacturer IKA-Werke GmbH & Co. KG
Type Oil-Free Diaphragm Pump
Pumping Speed 1 m³/h (16.67 L/min at 50/60 Hz)
Ultimate Pressure (without gas ballast) 9 mbar
Operating Input Pressure Range 10–1030 mbar
Speed Range 285–1100 rpm
Rated Speed 1100 rpm
Noise Level (low vacuum) 54 dB(A)
Dimensions (W×D×H) 115 × 292 × 280 mm
Weight 8.5 kg
Power Supply 100–240 V, 50/60 Hz
Rated Power Consumption 120 W
Standby Power 1.5 W
Enclosure Protection IP20 (DIN EN 60529)
Wetted Materials Al₂O₃, PTFE, FFKM (FFPM), PPS, NBR
Housing Material Cast aluminum with thermoplastic polymer coating
Ambient Temperature Range 5–40 °C
Max. Relative Humidity 80% @ ≤31 °C, linearly decreasing to 50% @ 40 °C
Interfaces USB-C, Analog Input (0–10 V)
Display LED line display

Overview

The IKA VACSTAR lite Starter Plus Solution is an integrated, oil-free diaphragm vacuum system engineered for precise, stable, and programmable vacuum control in routine laboratory workflows. Unlike conventional fixed-speed vacuum pumps, the VACSTAR lite employs a brushless DC motor coupled with real-time pressure feedback to dynamically adjust rotational speed—enabling continuous regulation of vacuum level across a wide operational range (10–1030 mbar). This closed-loop control architecture eliminates manual venting, prevents overshoot during sensitive processes (e.g., solvent evaporation or vacuum filtration), and ensures reproducible process conditions essential for method transfer and regulatory compliance. Designed for integration into GLP- and GMP-aligned environments, the system meets key safety and electromagnetic compatibility requirements per EN 61326-1 and operates within the environmental specifications defined by DIN EN 60529 (IP20). Its compact footprint and low acoustic signature (54 dB(A) at low vacuum) support deployment in shared lab spaces without compromising operator comfort or ambient noise thresholds.

Key Features

  • Intelligent speed-regulated diaphragm pump delivering true vacuum stability via closed-loop pressure control—not merely variable-speed operation
  • Integrated analog input (0–10 V) enabling external process feedback integration (e.g., from digital manometers or reactor controllers)
  • USB-C interface supporting firmware updates, parameter logging, and remote monitoring via IKA LabWorld software
  • LED line display providing real-time vacuum reading, setpoint, current speed (rpm), and status indicators (e.g., overtemperature, blockage detection)
  • Chemically resistant wetted path constructed from PTFE, FFKM, Al₂O₃, PPS, and NBR—suitable for aggressive solvents including acetone, ethyl acetate, and chlorinated hydrocarbons
  • Energy-efficient design with 1.5 W standby consumption and automatic sleep mode activation after 30 minutes of inactivity
  • Modular starter kit includes VC 10 lite vacuum controller and VSE 1 secondary condenser—eliminating need for third-party accessories during initial setup

Sample Compatibility & Compliance

The VACSTAR lite is compatible with standard Schlenk lines, Büchner funnels, rotary evaporators (including IKA RV 10 series), and vacuum ovens operating below 100 °C. Its dry, oil-free operation prevents sample contamination and eliminates maintenance associated with oil changes or vapor backstreaming—critical for pharmaceutical QC labs subject to USP and FDA 21 CFR Part 11 audit requirements. The system conforms to IEC 61000-6-3 (EMI emission) and IEC 61000-6-2 (immunity), and its electrical safety complies with EN 61010-1. All firmware and communication protocols support audit-trail-capable data recording when used with validated IKA LabWorld software configurations—facilitating alignment with ISO/IEC 17025 and EU Annex 11 expectations for electronic records.

Software & Data Management

The VACSTAR lite interfaces natively with IKA LabWorld software (Windows/macOS), enabling centralized configuration of vacuum ramps, hold times, and multi-step profiles. Logged data—including vacuum setpoint, actual pressure, motor speed, and runtime—is timestamped and exportable in CSV or PDF formats. When deployed in networked lab environments, the pump supports secure HTTPS-based API access for integration into LIMS or ELN platforms. All parameter changes are recorded with user ID, timestamp, and reason-for-change fields—meeting ALCOA+ principles (Attributable, Legible, Contemporaneous, Original, Accurate, Complete, Consistent, Enduring, Available) for data integrity in regulated settings.

Applications

  • Controlled solvent removal in rotary evaporation—preventing bumping and foaming through adaptive vacuum modulation
  • High-reproducibility vacuum filtration of crystalline APIs or nanoparticle suspensions
  • Deaeration of polymer precursors and resin formulations prior to casting or injection molding
  • Stable vacuum conditioning of hygroscopic reference standards in analytical calibration labs
  • Automated vacuum-assisted sample preparation for GC-MS and HPLC workflows
  • Process development studies requiring precise vacuum ramping (e.g., lyophilization cycle optimization)

FAQ

Is the VACSTAR lite suitable for use with corrosive vapors such as HCl or HF?
The wetted materials (FFKM, PTFE, Al₂O₃) provide broad chemical resistance, but direct exposure to anhydrous HCl or HF is not recommended. For such applications, consult IKA’s application engineering team for optional corrosion-resistant upgrades.
Can the pump be operated continuously at ultimate vacuum (9 mbar)?
Yes—the motor and diaphragm assembly are rated for indefinite operation at full vacuum; thermal management is ensured via cast-aluminum housing and internal airflow design.
Does the system support 21 CFR Part 11-compliant electronic signatures?
The hardware itself does not generate electronic signatures, but when paired with validated IKA LabWorld software and appropriate IT infrastructure, it supports Part 11-compliant audit trails, role-based access, and electronic record retention.
What is the expected service life of the diaphragm under typical lab usage?
Based on accelerated lifetime testing at 1100 rpm and 50% duty cycle, the diaphragm maintains performance specification for ≥15,000 hours; replacement kits are available with traceable calibration certificates.
Is external cooling required for extended operation?
No—ambient air convection is sufficient within the specified temperature range (5–40 °C); no water or forced-air cooling is necessary.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0