| Brand | Steelco |
|---|---|
| Origin | Italy |
| Model | LAB900 |
| Chamber Volume | 500 L |
| Heating Power | 5100 W |
| Wash Temperature | Adjustable |
| Compatible Detergent Types | Alkaline and Acidic |
| External Dimensions (L×W×D) | 1140 × 915 × 1900 mm |
| Brand | Schmidt+Haensh (S+H) |
|---|---|
| Country of Origin | Germany |
| Model | Portable Refractometer |
| Measurement Range | 0.0–60.0 °Brix or 45–90 °Brix |
| Resolution | 0.1 °Brix |
| Accuracy | ±0.2 °Brix |
| Measurement Time | 2 s |
| Sample Volume | >0.1 mL |
| Operating Temperature | +10 °C to +70 °C |
| Measured Temperature Range | up to 100 °C |
| Power Supply | Battery-operated |
| Units | °Brix |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Origin | Germany |
| Model | ATR-BR |
| Product Type | In-line / Laboratory Refractometer |
| Temperature Control | Integrated Peltier-free prism temperature sensing |
| Digital Display | Backlit LCD (16×16 characters) |
| Measurement Range | 1.32000–1.54000 RI / 0–100 %Brix |
| Resolution | 0.00001 RI / 0.01 %Brix |
| Accuracy | ±0.00002 RI / ±0.01 %Brix (1.32–1.44), ±0.00003 RI / ±0.01 %Brix (1.44–1.54) |
| Repeatability | 0.00001 RI / 0.01 %Brix |
| Temperature Sensing | NTC sensor embedded in sapphire prism, accuracy ±0.03 °C, repeatability ±0.02 °C |
| Sample Volume | 0.3 mL |
| Prism Material | Sapphire |
| Light Source | LED with integrated interference filter, λ = 589 nm |
| Interfaces | RS-232C (bidirectional), Centronics parallel port, USB (optional) |
| Compliance | ASTM D1218, DIN 51757, ISO 21542, USP <781>, ICUMSA Method GS2/3-13, AOAC 932.12, FDA 21 CFR Part 11 (with optional audit trail software) |
| Brand | Innoteg |
|---|---|
| Origin | Germany |
| Model | Pett Fix |
| Type | Single-Channel Fixed-Volume Pipette |
| Maximum Volume | 1000 µL |
| Sterilization | Full-Assembly Autoclavable (121°C, 20 min) |
| Tip Compatibility | Standard Conical Tips (ISO 8655-compliant) |
| Operating Temperature Range | 15–30°C |
| Relative Humidity | 30–70% RH (non-condensing) |
| Calibration Interval | Recommended annually per ISO 8655-5 |
| Compliance | ISO 8655-1, -2, -5 |
| Brand | Schmidt+Haensh (S+H) |
|---|---|
| Country of Origin | Germany |
| Model | ATR-B/F new |
| Type | Benchtop Refractometer |
| Temperature Control | Built-in Peltier |
| Digital Display | 7" TFT Touchscreen |
| Measurement Range | 1.32000–1.7000 RI / 0–100% Brix |
| Resolution | 0.00001 RI / 0.01% Brix |
| Accuracy | ±0.00002 RI / ±0.02% Brix |
| Light Source | LED with 589 nm interference filter (>100,000 h lifetime) |
| Compliance | ASTM, ISO, DIN, USP, ICUMSA, FDA 21 CFR Part 11 ready (optional software), GLP/GMP compliant |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | ROTANTA 460 / ROTANTA 460R |
| Type | Benchtop Centrifuge |
| Speed Range | 15,000 min⁻¹ |
| Max RCF | 24,400 × g |
| Max Capacity | 4 × 1000 mL |
| Dimensions (H×W×D) | ROTANTA 460: 456 × 554 × 706 mm |
| ROTANTA 460R | 456 × 770 × 706 mm |
| Weight | 101 kg / 141 kg |
| Power Supply | 200–240 V, 1~ |
| Power Consumption | 1000 VA (460) / 1800 VA (460R) |
| EMC Compliance | EN/IEC 61326-1 Class B |
| Timer Range | 1 sec – 99 h 59 min 59 sec + ∞ / pulse mode |
| Rotor Recognition | Automatic |
| Safety Features | Lid interlock with emergency release, imbalance detection & auto-shutdown, large transparent lid window, no external safety hood required |
| Brand | Parker Domnick Hunter |
|---|---|
| Origin | United Kingdom |
| Model | LCMS64/65 (Hunter Series) |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) with Carbon Molecular Sieve |
| Output Flow Rate | 18 L/min |
| Output Pressure | 7 bar |
| Nitrogen Purity | >99.999% (for collision gas stream) |
| Dew Point | −40 °C |
| Certifications | CE, UL |
| Compliance | ISO 9001 certified manufacturing |
| Phthalate-Free Construction | Yes |
| Integrated Oil-Free Compressor | Yes |
| Control Interface | LCD microprocessor-based controller |
| Monitoring | Five inline pressure gauges |
| Maintenance Alerts | Automated system diagnostics and service prompts |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | INNOTEG Syringe Filters |
| Pricing | Available Upon Request |
| Membrane Materials | Nylon 66, Hydrophobic PTFE, Hydrophilic PTFE, Polyethersulfone (PES), Polyvinylidene Fluoride (PVDF), Mixed Cellulose Ester (MCE) |
| Pore Sizes | 0.22 µm and 0.45 µm |
| Diameters | 13 mm and 25 mm |
| Connector Type | Luer Lock / Luer Slip Compatible |
| Packaging | 100 units per canister |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | NDA702 |
| Analysis Principle | Dumas Combustion Method |
| Carrier Gases | Helium or Argon (switchable without hardware modification) |
| Digestion/Combustion Time | 3–4 min per sample |
| Repeatability (RSD) | < 0.5% |
| Recovery Rate | > 99.5% |
| Detection Limit | 0.001 mg N (He), 0.01 mg N (Ar) |
| Combustion Temperature | 1030 °C |
| Power Consumption | 1400 W |
| Auto-sampler Capacity | Up to 117 positions (4 trays × 30 positions) |
| Dimensions (W×D×H) | 655 × 510 × 410 mm |
| Weight | 55 kg |
| Electrical Supply | 230 V / 50 Hz |
| Gas Purity Requirement | ≥99.999% for He/Ar and O₂ |
| Gas Pressure Requirement | 2 bar for carrier gas and O₂ |
| Detector | Calibrated Thermal Conductivity Detector (TCD), reference-gas-free operation |
| Sample Mass Range | Up to 1.0 g |
| Data Interfaces | USB, RS232 |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Origin | Germany |
| Model | VariRef A / B / C |
| Product Type | Inline Refractometer |
| Temperature Control | Dual-isolated Peltier system |
| Digital Display | 5" or 7" capacitive touchscreen (800 × 480 px, 16-bit color) |
| Measurement Range | 1.320000–1.580000 RI / 100% Brix (VariRef A) |
| Accuracy | ±0.00002 RI / ±0.02% Brix |
| Resolution | 0.00001 RI / 0.01% Brix |
| Repeatability | ±0.00001 RI / ±0.01% Brix |
| Temperature Control Range | +5°C to +100°C (VariRef B, customizable) |
| Temperature Accuracy | ±0.03°C |
| Prism Material | Sapphire (A & C), Sapphire/YAG (B) |
| Light Source | LED with integrated 589 nm interference filter |
| Compliance | ASTM D1218, ISO 2160, USP <781>, Ph. Eur. 2.2.12, ICUMSA Methods GS2/3-13, AOAC 932.12, DIN 51757, FDA 21 CFR Part 11 (software-enabled), GLP/GMP audit trail support |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Supplier Type | Authorized Distributor |
| Product Category | Domestic Standard Reference Materials |
| Schedule Classification | China NMPA Schedule II Psychotropic Substances |
| Pricing | Available Upon Request |
| Brand | SP Scientific |
|---|---|
| Origin | USA |
| Manufacturer | SP Scientific (integrated VirTis, FTS, Hull) |
| Type | Manifold & Shelf-Style Pilot-Scale Freeze Dryer |
| Application | Pilot Production & Process Development |
| Shelf Area | 2.13 m² |
| Ultimate Vacuum | ≤15 mTorr |
| Condenser Capacity (24 h) | 35 L |
| Condenser Temperature | −85 °C |
| Shelf Temperature Range | −55 °C to +65 °C |
| Shelf Uniformity | ±1.5 °C |
| Available Configurations | Tray-Loading or Stoppering |
| Optional Accessories | Pirani Gauge, Capacitance Manometer, Pressure Rise Test (PRT), Manifold Drying Module |
| Compliance | ISO 9001:2000 certified |
| Brand | Pickering |
|---|---|
| Origin | USA |
| Model | Vector PCX |
| Temperature Range | 5 °C – 130 °C |
| Derivatization Reagent Flow Rate | 0.05 – 2.0 mL/min |
| Reaction Coil Volume | 0.1 – 3.0 mL |
| Construction | PEEK Fluidic Path |
| Flow Control | Electronic, Pulse-Free |
| Safety | Integrated Leak Detection, Over-Temperature & Over-Pressure Protection |
| Compliance | Designed for GLP/GMP environments |
| Brand | Think-lab |
|---|---|
| Origin | Germany |
| Model | Smart |
| Feed Water | Type I purified water (deionized, distilled or RO) |
| Product Water Resistivity | ≥18.2 MΩ·cm @ 25°C |
| TOC | <5 ppb |
| Microbial Count | <0.001 CFU/mL |
| Endotoxin | <0.001 EU/mL |
| Flow Rate | Up to 1.5 L/min |
| Feed Pressure Range | 0.1–6 bar |
| Integrated UV | Dual-wavelength (185 nm + 254 nm) |
| Final Filtration | 0.2 µm charged polyethersulfone (cPES) end-filter |
| Conductivity Monitoring | Dual-channel (feed & product) |
| Sanitization Method | Injection-based chemical recirculation sanitization |
| System Footprint | Compact integrated design |
| Brand | Elma (Germany) |
|---|---|
| Origin | Germany |
| Model | S50R |
| Type | General-Purpose Ultrasonic Cleaner |
| Tank Volume | 5.3 L |
| Internal Dimensions | Ø240 mm × 130 mm (H) |
| External Dimensions | Ø260 mm × 350 mm (H) |
| Basket Dimensions | Ø220 mm × 70 mm (H) |
| Ultrasonic Frequency | 37 kHz |
| Timer Range | 1–30 min (plus continuous mode with auto-shutdown after 12 h) |
| Power Consumption | 150 W |
| Weight | 5.0 kg |
| Protection Class | IP20 |
| Compliance | CE (Low Voltage Directive 2006/95/EC & EMC Directive 2004/108/EC) |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Model | RFM990-Flow |
| Refractive Index Range | 1.30–1.70 |
| Brix Range | 0–100 |
| RI Resolution | 0.00001 |
| Brix Resolution | 0.01 |
| RI Accuracy | ±0.00002 |
| Brix Accuracy | ±0.02 |
| Light Source | LED (589.3 nm, >100,000 hr lifetime) |
| Temperature Control | Integrated Peltier element |
| Sample Cell Volumes | 0.6 mL (micro), 1.2 mL (standard), 1.2 mL (funnel-type) |
| Compliance | OIML R22, ASTM D5006, USP <781>, EP 2.2.2, BP Appendix XVII, FDA 21 CFR Part 11, GLP/GMP data integrity requirements |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | XLS483F |
| Airflow Type | Vertical Laminar Flow |
| Filtration Class | ISO Class 5 (equivalent to US Federal Standard 209E Class 100) |
| Filter Efficiency | ≥99.995% @ 0.3 µm (EN 1822-1, MPPS test) |
| Working Height Adjustment Range | 1014 mm (internal) |
| External Dimensions (L×W×H) | 1275 × 790 × 1316–1400 mm |
| Internal Dimensions (L×W×H) | 1172 × 692 × 1014 mm |
| Face Velocity | >0.3 m/s |
| Airflow Volume | 690 m³/h |
| Fan Configuration | 3 × LP44 centrifugal fans |
| Power Supply | 100–240 V AC, 50–60 Hz |
| Total Power Consumption | 175 W |
| Sound Pressure Level | 58 dB(A) |
| Pre-filter & HEPA Filter Monitoring | Integrated differential pressure gauge |
| Safety Alarms | Audible and visual fan failure alert |
| Standard Work Surface | Stainless steel (304 brushed, 2 mm thick, radius-edged) |
| Optional Surfaces | Solid phenolic resin (25 mm, chemical-resistant, spill-containment groove), fixed-height workbench with leveling feet |
| Optional Upgrade | GF4BE+ activated carbon filter module for gaseous contaminant removal |
| Chemical Compatibility | Liquids, liquid–dust mixtures, dry powders, weighing in controlled environments |
| Brand | INNOTEG |
|---|---|
| Origin | Italy |
| Model | HP-HG250 |
| Hydrogen Generation Principle | PEM Electrolysis of Deionized Water |
| Output Flow Rate | 250 mL/min |
| Output Pressure | 11 bar |
| Hydrogen Purity | >99.9996% |
| Power Consumption | 200 W |
| Certifications | CE, FCC, MET (UL/CSA) |
| Continuous Operation | 24/7, 365 days/year |
| Safety Features | Dual Internal/External H₂ Leak Detection with Auto-Shutdown, Liquid Level Monitoring, Conductivity-Based Water Quality Monitoring |
| Optional Functions | Automatic Refill, Cascade Operation |
| Brand | Memmert |
|---|---|
| Origin | Germany |
| Model Series | UNpa 30 / UNpa 55 / UNpa 75 / UNpa 110 / UNpa 160 |
| Temperature Range | +20 °C to +80 °C |
| Chamber Volume | 30 L / 55 L / 75 L / 110 L / 160 L |
| Heating Principle | Quadruple-wall conduction heating with passive thermal homogenization |
| Safety | Dual independent overtemperature protection (mechanical + electronic), hermetically sealed chamber design |
| Compliance | IEC 61010-1, EN 61326-1 (EMC), CE-marked for laboratory use |
| Brand | Genevac |
|---|---|
| Origin | United Kingdom |
| Model | DNA |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient, 30–80 °C (adjustable in 1 °C increments) |
| Vacuum Level | 10 mbar |
| Rotational Speed | 1465 rpm |
| Dimensions (W×D×H) | 360 × 597 × 300 mm |
| Weight | 34 kg |
| Rotor Configurations | 48 × 1.5 mL tubes, 12 × 15 mL tubes, 8 × 50 mL tubes, 96-well microplates |
| Cold Trap | Not included |
| Pressure Controller | Not included |
| Operating Modes | Water, Alcohol, Other Solvents |
| Sample Compatibility | Tubes, microcentrifuge tubes, vials, round-bottom flasks, 96-well plates |
| Brand | Pharmag |
|---|---|
| Origin | Germany |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | CUB-2000 Series |
| Capacity | 2 L (dry solids), 3 L (wet/dispersed samples) |
| Motion Principle | 3D Tumbling Rotation |
| Application Scope | Powder & granule blending, coating processes, dyeing matrix homogenization, resin drum mixing |
| Brand | Schmidt+Haensch (S+H) |
|---|---|
| Country of Origin | Germany |
| Model | ATR W1 / W1 Plus / W2 / W2 Plus |
| Refractive Index Range | RI 1.33200–1.53200 (W1/W1 Plus), RI 1.33200–1.70000 (W2/W2 Plus) |
| Brix Range | 0–95% (W1/W1 Plus), 0–100% (W2/W2 Plus) |
| Resolution | RI 0.00002 / Brix 0.02 (W1/W1 Plus), RI 0.00001 / Brix 0.01 (W2/W2 Plus) |
| Accuracy | ±0.00004 RI / ±0.04 Brix (W1/W1 Plus), ±0.00002 RI / ±0.02 Brix (W2/W2 Plus) |
| Temperature Control | Peltier-controlled sapphire prism, operating range +10°C to +80°C |
| Brand | Pharma-test |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PTWS 820D |
| Price | USD 33,500 (FOB Hamburg, ex-works condition) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | BOD10 |
| Instrument Type | Laboratory |
| Measurement Principle | Pressure-based Respirometric Method (Mercury-Free Electronic Transducer) |
| Measurement Ranges | 90, 250, 600, 999 mg/L BOD₅ |
| Data Logging Interval | 24 h (5-point profile over standard 5-day incubation) |
| Operating Duration | Configurable from 1 to 28 days |
| Power Supply | Dual Lithium-Ion Batteries (2-year service life) |
| Safety Rating | IEC 61010-1 Class III |
| Ingress Protection | IP54 per EN 60529 |
| Operating Temperature | −20 °C to +65 °C |
| Weight | 80 g |
| Enclosure Material | Stainless Steel (316) with Chemical-Resistant Coating |
| Sample Capacity | Simultaneous monitoring of up to 10 samples (BOD Sensor System 10 configuration) |
| Alarm Function | Automatic out-of-range alert |
| Compliance | ASTM D5210, ISO 5815-1:2019, APHA 5210B, EU Directive 2000/60/EC (Water Framework Directive) |