Empowering Scientific Discovery

Kanomax 6036-0C / 6036-BC Smart Thermal Anemometer & Air Flow Meter

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Kanomax
Origin Japan
Instrument Type Thermal Anemometer
Measurement Range 0.01–30.0 m/s
Accuracy ±3% of reading (m/s)
Resolution ±2% of reading
Temperature Range −20 to +70 °C
Temperature Accuracy ±0.5 °C
Pressure Range (6036-BC only) −5.0 to +5.0 kPa
Pressure Accuracy ±3% of reading
Operating Humidity 2.0–98.0% RH
Data Storage Capacity 1,500 records
Interface USB
Dimensions 66 × 51 × 188 mm
Weight 400 g (without batteries)

Overview

The Kanomax 6036-0C and 6036-BC are handheld, microprocessor-controlled thermal anemometers engineered for high-reliability air velocity, volumetric flow, temperature, and (in the BC variant) differential pressure measurement in HVAC commissioning, environmental validation, and industrial ventilation assessment. These instruments operate on constant-temperature anemometry (CTA) principles: a heated sensor element is maintained at a fixed temperature above ambient; convective heat loss correlates directly with local airflow velocity, enabling precise, low-range detection from 0.01 m/s—critical for laminar flow hoods, cleanroom supply diffusers, and duct traverse applications. Unlike cup or vane anemometers, thermal sensors respond instantaneously to transient flow changes and exhibit minimal directional sensitivity, making them suitable for complex geometries and low-velocity environments where mechanical inertia limits performance.

Key Features

  • Simultaneous real-time measurement of air velocity (0.01–30.0 m/s), temperature (−20 to +70 °C), and—on the 6036-BC model—differential pressure (±5.0 kPa)
  • Extendable, flexible probe with 360° bendable tip for accessing confined ducts, grilles, and irregular cross-sections without disassembly
  • On-device calculation of volumetric airflow (m³/h or CFM) when user inputs duct geometry (rectangular, circular, or custom polygonal cross-section) and dimensions
  • Integrated statistical functions: hold, min/max/average recording, and automatic time-weighted averaging over user-defined intervals
  • Internal memory stores up to 1,500 timestamped data sets with full parameter logging (velocity, temp, pressure, date/time)
  • USB interface enables direct connection to Windows-based PCs for firmware updates, real-time streaming, and post-processing via Kanomax’s proprietary data management software
  • Rugged, ergonomic housing (66 × 51 × 188 mm; 400 g) with IP54-rated ingress protection against dust and water splashes during field use

Sample Compatibility & Compliance

The 6036 series is validated for use across indoor air quality (IAQ) surveys, HVAC system balancing per ASHRAE Guideline 111, cleanroom airflow uniformity testing (ISO 14644-3), and pharmaceutical facility qualification (EU GMP Annex 1, FDA Guidance for Aseptic Processing). Its thermal sensor design ensures stable response in non-corrosive, non-condensing airstreams within the specified humidity range (2.0–98.0% RH). The instrument complies with IEC 61000-4 electromagnetic compatibility standards and carries CE marking for conformity with EU safety directives. While not intrinsically safe, it is suitable for general laboratory, commercial building, and light industrial environments—not classified hazardous locations.

Software & Data Management

Kanomax provides dedicated PC software compatible with Windows 10/11 for configuration, live monitoring, and report generation. The application supports export to CSV, Excel, and PDF formats with customizable templates for audit-ready documentation. All stored datasets include embedded metadata (probe ID, operator tag, location code), supporting traceability requirements under ISO/IEC 17025 and FDA 21 CFR Part 11 when used with appropriate electronic signature controls. Audit trails, user access levels, and data integrity checks can be implemented via third-party LIMS integration using standard USB HID protocols.

Applications

  • HVAC system commissioning and TAB (Testing, Adjusting, Balancing) per NEBB and AABC standards
  • Cleanroom airflow visualization and velocity mapping (supply/exhaust, unidirectional flow verification)
  • Pharmaceutical isolator and glovebox air change rate validation
  • Industrial exhaust hood face velocity surveys for OSHA and ANSI Z9.5 compliance
  • Electronic cooling fan characterization and thermal management R&D
  • Energy audit assessments including duct leakage estimation and fan efficiency calculations

FAQ

What is the difference between the 6036-0C and 6036-BC models?

The 6036-0C measures air velocity and temperature only; the 6036-BC adds a built-in differential pressure sensor for simultaneous static/dynamic pressure readings.
Can the device calculate volumetric flow in non-rectangular ducts?

Yes—users manually define custom cross-sectional geometry (e.g., oval, trapezoidal) by entering coordinate points or selecting preconfigured shapes in the software interface.
Is calibration certificate included with purchase?

A factory calibration report traceable to JCSS (Japan Calibration Service System) is supplied; NIST-traceable calibration certificates are available as optional add-ons.
Does the instrument support continuous logging over extended periods?

Yes—when connected via USB to a powered host, the device operates in streaming mode with no internal storage limitation; battery-powered standalone logging is limited to 1,500 records.
How is temperature compensation handled during velocity measurement?

The unit employs dual-sensor thermal compensation: the velocity sensor and reference temperature sensor are co-located and thermally coupled, minimizing drift across the full −20 to +70 °C operating range.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0