Empowering Scientific Discovery

Lovibond PFXeo Advanced Colorimeter

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Lovibond (Tintometer Ltd.)
Origin United Kingdom
Model PFXeo
Measurement Principle Absorption Photometry at Defined Wavelengths
Optical System Single-beam Spectrophotometric Colorimeter
Light Source Tungsten-Halogen Lamp
Spectral Range 380–780 nm
Wavelength Accuracy ±0.2 nm
Spectral Bandwidth <15 nm
Photometric Range 0–100% Transmittance (T)
Photometric Linearity ±0.01% T
Stray Light <0.01% T
Repeatability ±0.5% T
Detector Type Silicon Photodiode Array
Sample Temperature Control Integrated Peltier Heater (Ambient to +60°C)
Display Real-time Sample Temperature & Color Value
Sample Cell Options 25 mm (1") and 133 mm (5.25") pathlength cuvettes, sealed & chemically resistant
Housing Material Recyclable anodized aluminum (100% recyclable)
Dimensions 301 × 152 × 331 mm (W×H×D)
Weight 5.16 kg
Operating Environment 5–40°C, ≤90% RH (non-condensing)
Storage −20–+85°C, ≤90% RH (non-condensing)
Power Supply 190–240 V AC
Interfaces USB 2.0, RS-232
Compliance CE Marked
Supported Standards Lovibond® RYBN, Lovibond RY10:1, AOCS Cc 13b-45 / Cc 8d-55 / Cc 13j-97 / Cc 13e / Cc 13j, ISO 15305, IP 17, MS 252 Part 16, GB/T 22460-2008
Languages English, Chinese, French, German, Italian, Spanish, Portuguese, Russian, Japanese

Overview

The Lovibond® PFXeo Advanced Colorimeter is a purpose-engineered spectrophotometric instrument designed specifically for the precise, standardized color assessment of edible oils, fats, and related lipid-based products. Unlike general-purpose colorimeters, the PFXeo implements absorption photometry across the visible spectrum (380–780 nm) using a stabilized tungsten-halogen light source and silicon photodiode array detection. Its optical architecture adheres to the fundamental principles of Beer–Lambert law-based transmittance measurement, enabling quantitative determination of color intensity in accordance with internationally recognized industry standards—including AOCS, ISO, IP, and national specifications such as GB/T 22460-2008. A key differentiator is its integrated Peltier heating system, which maintains sample temperature stability during measurement—critical for preventing crystallization or phase separation in high-melting-point oils (e.g., palm olein, coconut oil, or hydrogenated shortenings). Real-time temperature monitoring ensures data validity by confirming that measurements are performed under thermodynamically consistent conditions.

Key Features

  • Integrated Peltier heater enabling controlled sample warming from ambient up to +60°C—eliminating cold-induced turbidity and ensuring representative liquid-phase analysis
  • Real-time digital display of both color value (e.g., Lovibond RYBN units) and actual sample temperature—preventing erroneous readings due to sub-cooled or partially solidified samples
  • Pre-programmed compliance with 12+ standardized color scales including Lovibond® RYBN, Lovibond RY10:1, AOCS RY (Cc 13b-45, Cc 8d-55, Cc 13j-97), ISO 15305, and IP 17 Method A
  • Chemically inert, sealed sample cells in two standard pathlengths (25 mm and 133 mm) optimized for low-absorbance and high-absorbance oils respectively
  • Anodized aluminum housing—fully recyclable, corrosion-resistant, and engineered for continuous operation in refinery-grade environments (e.g., high humidity, trace hydrocarbon vapors)
  • High-fidelity optical performance: wavelength accuracy ±0.2 nm, spectral bandwidth <15 nm, stray light <0.01% T, and photometric repeatability ±0.5% T
  • Intuitive on-device interface supporting nine languages and direct USB/RS-232 connectivity for instrument control and data export

Sample Compatibility & Compliance

The PFXeo is validated for use with clarified, filtered edible oils—including soybean, sunflower, rapeseed (canola), palm, corn, olive, and peanut oils—as well as refined animal fats and hydrogenated vegetable shortenings. Its thermal stabilization capability makes it uniquely suitable for oils prone to cloud point transitions near room temperature. All measurement protocols conform to method requirements defined in AOCS Official Methods Cc 13b-45 (for RY scale), Cc 8d-55 (for RY10:1), and ISO 15305:2017 (for RYBN). The instrument supports full audit trail generation when paired with compliant laboratory information management systems (LIMS), and its firmware architecture allows traceability of calibration events, user actions, and environmental parameters—facilitating GLP/GMP-aligned documentation per FDA 21 CFR Part 11 where electronic records are employed.

Software & Data Management

Data acquisition and reporting are supported via native USB mass storage mode: results—including color values, temperature stamps, date/time stamps, operator ID, and method identifiers—are automatically saved to removable USB drives in CSV format for downstream statistical process control (SPC) or quality assurance (QA) review. RS-232 serial output enables integration into legacy SCADA or PLC-based refinery monitoring systems. No proprietary software installation is required; exported files are compatible with Microsoft Excel, Minitab, JMP, and most LIMS platforms. Firmware updates are delivered via signed binary packages distributed through Lovibond’s authorized service portal, ensuring version control and cybersecurity integrity.

Applications

  • Quality control of crude and refined edible oils during degumming, bleaching, and deodorization stages
  • Batch release testing against AOCS or ISO color specifications prior to packaging
  • Monitoring color drift during extended storage or thermal oxidation studies
  • Validation of filtration efficiency in clay or activated carbon treatment units
  • Supporting R&D activities in lipid modification, blending optimization, and shelf-life prediction models
  • Regulatory submissions requiring documented, repeatable color metrics aligned with Codex Alimentarius or national food standards

FAQ

Does the PFXeo require external calibration standards for routine operation?
No—factory-calibrated using NIST-traceable Lovibond reference filters; optional annual verification with certified RYBN standard sets is recommended for ISO/IEC 17025-accredited labs.
Can the PFXeo measure unfiltered or hazy oil samples?
It is intended for use with optically clear, particle-free samples; pre-filtration through 0.45 µm membrane filters is required to avoid scattering artifacts.
Is the heating function programmable or fixed?
The heater operates in closed-loop mode to maintain user-selected setpoints between ambient and +60°C in 1°C increments; temperature is continuously monitored and displayed.
What is the expected lifetime of the tungsten-halogen lamp?
Rated for ≥2,000 hours of operation under typical usage; lamp replacement is a field-serviceable procedure requiring no optical realignment.
Does the instrument support custom color scale definition?
No—only pre-validated scales compliant with AOCS, ISO, IP, and GB/T standards are embedded; custom algorithm development is not supported per regulatory design constraints.