| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | AF325 |
| Light Path | 113 mm |
| Standard Scale Range | 0–250 mg Pt/L (APHA/Hazen) |
| Compliant Standards | ASTM D1209, ISO 2211, ISO 6271, AOCS Td 1b-64, BS 5339 |
| Sample Compatibility | Clear, pale-yellow liquids |
| Calibration Method | Nessleriser 2150 comparator disc system |
| Scale Segments | NSH (10–90), NSB (70–250) |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | AF327 |
| Measuring Range | 0–70 mg Pt/L (Platinum-Cobalt Units) |
| Cell Path Length | 288 mm |
| Standard Discs | 1209/1 (0–30 APHA), 1209/2 (30–70 APHA) |
| Compliant Standards | ASTM D1209, ISO 2211, ISO 6271, AOCS Td 1b-64, BS 5339 |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | AF328 |
| Measuring Range | 0–70 mg Pt/L (Platinum-Cobalt Units) |
| Cell Path Length | 250 mm |
| Standard Discs | CAA (0–30 APHA), CAB (30–70 APHA) |
| Compliant Standards | ASTM D1209, ISO 2211, ISO 6271, AOCS Td 1b-64, BS 5339 |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | AF329 |
| Measurement Range | 0–500 Pt-Co Units |
| Compliance | ASTM D1209, AOCS Td 1b-64, ISO 2211, ISO 6271, BS 5339 |
| Application Scope | Clear, pale-yellow liquids only |
| Optical System | Visual comparator with standardized glass color standards |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | AF329 |
| Measuring Range | 0–250 mg Pt/L (APHA/Pt-Co Scale) |
| Cell Pathlengths | 113 mm and 250 mm |
| Standard Discs | CAA (0–30), CAB (30–70), NSB (70–250) |
| Compliant Standards | ASTM D1209, AOCS Td 1b-64, ISO 2211, ISO 6271, BS 5339 |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | AF330 |
| Measurement Range | EBC 2–27 |
| Wavelength | 430 nm (fixed, optimized for EBC scale) |
| Optical Path Length | Standard 10 mm cuvette (compatible with 5 mm, 20 mm, and 50 mm pathlength cells for sample dilution or concentration adjustment) |
| Compliance | Designed in accordance with EBC Method 2.1 & ASBC Beer-1 |
| Display | LED digital readout with EBC unit labeling |
| Power Supply | AC adapter or optional rechargeable battery pack |
| Dimensions | 185 × 120 × 85 mm |
| Weight | 0.9 kg |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | AF333 |
| Standard | DIN 6162 |
| Colour Range | Iodine Scale 1–500 |
| Application Scope | Solvents, Plasticizers, Resins, Oils, Fatty Acids |
| Alternate Scale Support | Pt-Co (APHA) for Samples < Iodine Unit 1 |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | AF607 |
| Light Source | Tungsten-halogen lamp compliant with CIE Illuminant B |
| Viewing System | Triple-field visual comparator |
| EBC Scale Range | 2–27 units |
| Resolution | ±0.5 EBC (2–10), ±1.0 EBC (10–27) |
| Compliance | EBC Method No. 3.1.1, ASBC Beer-1, ISO 4833-1:2013 (applicable for color standardization in brewing) |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | EC2000 Visual-Electronic Platinum-Cobalt Colorimeter |
| Measurement Principle | Visual-electronic comparison against Pt-Co (APHA) standard scale |
| Calibration Options | Certified glass filter set + reference liquid standards |
| Light Path Options | 10 mm, 20 mm, 50 mm (user-selectable) |
| Cuvette Materials | Optical-grade glass or disposable polystyrene |
| Display | 4.3-inch capacitive touchscreen with color-coded pass/fail indicators (green/amber/red) |
| Data Storage | >20,000 measurement records with timestamp, sample ID, operator ID, and method tag |
| Connectivity | USB-A port for data export (CSV format) |
| Power Supply | AC adapter (100–240 V) + internal rechargeable Li-ion battery (≥8 h continuous operation) |
| Enclosure | IP54-rated ruggedized housing |
| Compliance | Designed to support ASTM D1209, ISO 6271, ISO 7887, and USP <631> color assessment protocols |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | PFXeo |
| Measurement Principle | Absorption Photometry at Defined Wavelengths |
| Optical System | Single-beam Spectrophotometric Colorimeter |
| Light Source | Tungsten-Halogen Lamp |
| Spectral Range | 380–780 nm |
| Wavelength Accuracy | ±0.2 nm |
| Spectral Bandwidth | <15 nm |
| Photometric Range | 0–100% Transmittance (T) |
| Photometric Linearity | ±0.01% T |
| Stray Light | <0.01% T |
| Repeatability | ±0.5% T |
| Detector Type | Silicon Photodiode Array |
| Sample Temperature Control | Integrated Peltier Heater (Ambient to +60°C) |
| Display | Real-time Sample Temperature & Color Value |
| Sample Cell Options | 25 mm (1") and 133 mm (5.25") pathlength cuvettes, sealed & chemically resistant |
| Housing Material | Recyclable anodized aluminum (100% recyclable) |
| Dimensions | 301 × 152 × 331 mm (W×H×D) |
| Weight | 5.16 kg |
| Operating Environment | 5–40°C, ≤90% RH (non-condensing) |
| Storage | −20–+85°C, ≤90% RH (non-condensing) |
| Power Supply | 190–240 V AC |
| Interfaces | USB 2.0, RS-232 |
| Compliance | CE Marked |
| Supported Standards | Lovibond® RYBN, Lovibond RY10:1, AOCS Cc 13b-45 / Cc 8d-55 / Cc 13j-97 / Cc 13e / Cc 13j, ISO 15305, IP 17, MS 252 Part 16, GB/T 22460-2008 |
| Languages | English, Chinese, French, German, Italian, Spanish, Portuguese, Russian, Japanese |
| Brand | Lovibond (Tintometer Ltd) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi 880F |
| Measurement Principle | Tristimulus Filter Photometry |
| Standard Color Scales | Lovibond® RYBN, APHA/Pt-Co, Gardner, Saybolt, ASTM D1209/D5386/D6166, ISO 2764, ISO 4630, USP <631>, CIE L*a*b*, CIE XYZ, ΔE*ab |
| Display | High-contrast 7-inch TFT color touchscreen |
| Data Output | USB 2.0, Ethernet (LAN), RS232 |
| Compliance | CE, UKCA, RoHS, FDA 21 CFR Part 11 ready (audit trail & electronic signature support via optional software license) |
| Calibration | Factory-certified with RCMSi initial verification kit |
| Sample Cell Compatibility | 10 mm, 25 mm, 33 mm, 50 mm pathlength cells (1" and 5.25" round cells included) |
| Light Source | Tungsten-halogen lamp (3000 K CCT, stable spectral output per IEC 61000-4-11) |
| Repeatability | ≤ ±0.1 Lovibond unit (RYBN), ≤ ±0.3 APHA units (typical, under controlled lab conditions) |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi 950 |
| Compliance | ASTM D1209, ASTM D1500, ASTM D6045, AOCS Cd 13b-97, ISO 2761, ISO 4630, ISO 6271, Gardner ASTM D1544, Saybolt ASTM D156 |
| Measurement Principles | Transmission colorimetry using tungsten-halogen light source and precision interference filters |
| Display | High-resolution LCD with multilingual interface (including English & Chinese) |
| Sample Path Length Options | 10 mm, 20 mm, 33.3 mm, 50 mm, 100 mm |
| Output Data | CIE L*a*b*, CIE XYZ, CIE Yellowness Index (YI), Whiteness Index (WI), spectral reflectance/transmittance (380–720 nm, 10 nm intervals), and proprietary color scales |
| Connectivity | RS-232, USB, optional Ethernet |
| Software Compatibility | ColorSoft™ PC software for data export, audit trail, and report generation |
| Regulatory Support | FDA 21 CFR Part 11 compliant configuration available (with user authentication, electronic signatures, and full audit trail) |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/9 |
| Measurement Principle | Tristimulus Filter-Based Photometry |
| Light Source | Tungsten Halogen Lamp |
| Standard Cuvette | 10 mm Pathlength Glass Cell |
| Supported Color Scales | Lovibond®, Hunter Lab, CIELAB (L*C*h°), CIE XYZ, CIE Yellowness Index (YI), CIE Whiteness Index (WI), Spectral Data Output (31-point, 400–700 nm) |
| Interface | RS-232 & USB |
| Software Included | RCMSi Calibration & Data Management Suite for Windows |
| Compliance | ISO 4630 (Petroleum Products), ISO 27677 (Beer), AOAC Official Methods, ASTM D1209/D5386/D6290 |
| Calibration | Factory-Calibrated with NIST-Traceable Standards |
| Dimensions | 280 × 220 × 180 mm |
| Weight | 4.2 kg |
| Brand | Lovibond® (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Product Type | Certified Liquid Color Reference Standards |
| Compliance | AOCS, ASTM D1209/D5386/D6166, ISO 6271, EBC 1.3, Gardner ASTM D1544, Pt-Co (APHA/Hazen) ASTM D1209, Saybolt ASTM D156 |
| Format | 5¼" (133 mm) cylindrical glass cells |
| Shelf Life | 12 months from date of manufacture |
| Traceability | NIST-traceable spectrophotometric validation |
| Packaging | Individually labeled, amber glass vials with tamper-evident seals |
| Uncertainty | ±0.1 color unit (RYBN), ±1 APHA unit (Pt-Co), ±0.2 Gardner unit |