Empowering Scientific Discovery

METTLER TOLEDO MX6002DR Precision Balance

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand METTLER TOLEDO
Model MX6002DR
Max Capacity 32 kg
Readability 1 mg
IP Rating IP54
Compliance GxP-ready, FDA 21 CFR Part 11 compatible (with optional software), GLP/GMP audit trail support
Connectivity RS232, USB, Ethernet, optional Bluetooth/Wi-Fi module
Power Management Configurable energy-saving mode

Overview

The METTLER TOLEDO MX6002DR Precision Balance is an industrial-grade analytical and precision weighing instrument engineered for laboratories and production environments requiring high repeatability, traceable accuracy, and regulatory compliance. Built upon METTLER TOLEDO’s proprietary electromagnetic force compensation (EMFC) sensor architecture, the MX6002DR delivers stable, drift-resistant measurements across dynamic ambient conditions—enabling reliable 1 mg readability at full 32 kg capacity. Its core design integrates metrological rigor with operational intelligence: real-time status feedback via StatusLight™, adaptive environmental compensation algorithms, and a robust mechanical structure rated IP54 for dust resistance and limited water exposure. Unlike conventional balances relying solely on manual calibration intervals, the MX6002DR embeds proactive quality assurance logic—automatically prompting users for scheduled performance tests based on configurable process tolerances and internal stability metrics—thereby reinforcing measurement integrity throughout the calibration lifecycle.

Key Features

  • SmartPan™ technology: A patented dual-chamber weighing pan assembly that actively dampens air currents and floor vibrations, reducing settling time by up to 40% in non-ideal lab environments.
  • GxP-compliant operation: Supports role-based user authentication, electronic signatures, and full audit trail logging—including timestamped weight events, parameter changes, calibration actions, and test outcomes—aligned with FDA 21 CFR Part 11 requirements when paired with METTLER TOLEDO LabX® software.
  • Modular connectivity: Native RS232, USB Device/Host, and Ethernet interfaces enable seamless integration with LIMS, ERP, or MES systems; optional wireless modules support secure Bluetooth 5.0 or Wi-Fi 802.11ac for flexible deployment in distributed facilities.
  • Energy-aware operation: Programmable auto-standby and deep-sleep modes reduce power consumption during idle periods without compromising warm-up stability or measurement readiness.
  • Ergonomic interface: 7-inch high-resolution capacitive touchscreen with intuitive icon-driven navigation, customizable home screen layouts, and multi-language support (including English, German, French, Spanish, Chinese, Japanese).
  • Durability-focused construction: Stainless steel load receptor, reinforced polymer housing, and IP54-rated enclosure ensure long-term reliability in QC labs, pilot plants, and warehouse staging areas subject to routine cleaning or moderate particulate exposure.

Sample Compatibility & Compliance

The MX6002DR accommodates a broad range of sample types—from bulk powders and granules to packaged intermediates and pre-filled containers—without compromising resolution or linearity. Its large 240 × 240 mm SmartPan™ surface supports standard ISO/IEC 17025-compliant weighing vessels (e.g., glass beakers, stainless steel trays, polypropylene weigh boats) and facilitates easy cleaning between batches. The balance meets international metrological standards including OIML R76-1 (Class II), ANSI/NCSL Z540-1, and ISO 9001:2015 clause 7.6 requirements for monitoring and measuring equipment. For regulated pharmaceutical and biotech applications, it supports documented verification protocols per USP , , and EU Annex 11, with full data export capability to CSV, PDF, or XML formats for inclusion in validation master files.

Software & Data Management

When connected to METTLER TOLEDO LabX® software, the MX6002DR transforms into a fully auditable data acquisition node. LabX provides centralized method management, automated report generation (including statistical summaries, trend charts, and deviation alerts), and secure database archiving compliant with ALCOA+ principles (Attributable, Legible, Contemporaneous, Original, Accurate, Complete, Consistent, Enduring, Available). All weight data is encrypted in transit and at rest; user access levels are enforced through Windows Active Directory integration or local LDAP configuration. Electronic signatures adhere to digital certificate-based authentication, ensuring enforceable accountability across multi-site operations.

Applications

  • Quality control laboratories performing raw material acceptance testing, in-process checks, and finished product release assays.
  • Pharmaceutical manufacturing units executing batch record documentation, formulation dispensing, and reference standard preparation under cGMP conditions.
  • Chemical and materials R&D facilities conducting gravimetric analysis, catalyst loading, and polymer blend ratio verification.
  • Food and beverage QA departments validating net content compliance per FDA 21 CFR 101.105 and EU Regulation (EU) No 1169/2011.
  • Academic and contract research organizations requiring ISO/IEC 17025-accredited weighing workflows for method validation and inter-laboratory comparison studies.

FAQ

What is the maximum permissible error (MPE) for the MX6002DR at full capacity?

The MPE complies with OIML R76-1 Class II specifications: ±1.5e (where e = 1 mg), resulting in ±1.5 mg tolerance at ≤200 g and scaling linearly to ±48 mg at 32 kg.
Does the MX6002DR support automatic internal calibration?

No—it features external calibration capability only; however, its built-in test scheduler guides users through periodic performance verification using certified weights, ensuring ongoing confidence in measurement validity.
Can the balance be validated for use in a GMP environment?

Yes—METTLER TOLEDO provides IQ/OQ documentation templates, installation qualification kits, and risk-based validation support services aligned with ASTM E2500 and Annex 15 guidelines.
Is the SmartPan™ compatible with third-party draft shields?

Yes—the pan geometry and mounting interface conform to standard ISO 17025-compliant draft shield dimensions, enabling interoperability with most OEM and aftermarket enclosures.
How does the MX6002DR handle temperature-induced drift?

It incorporates real-time thermal compensation using dual-sensor thermal mapping and adaptive zero-tracking algorithms, maintaining stability within ±0.5 mg over 15–35 °C ambient range without manual re-zeroing.