MNR HCS-501 Precision Air Conditioning & Humidification Control System

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Origin USA
Manufacturer Type Authorized Distributor
Origin Category Imported Instrument
Model HCS-501
Pricing Available Upon Request

Overview

The MNR HCS-501 Precision Air Conditioning & Humidification Control System is an engineered environmental control platform designed for laboratory-scale conditioning of supply air in analytical, pharmaceutical, and materials testing applications. It operates on a closed-loop feedback architecture integrating digital mass flow control, high-stability capacitive humidity sensing, and PT100-class temperature measurement. Unlike basic humidifiers or standalone dryers, the HCS-501 delivers simultaneous, independent regulation of airflow rate (2–500 L/min), temperature (20–35°C standard; lower with optional condensation module), and relative humidity (20–85% RH at 25°C), enabling reproducible gas-phase conditioning critical for gravimetric analysis, stability chamber validation, sensor calibration, and inhalation toxicology exposure studies.

Key Features

  • Microprocessor-based control system with real-time PID algorithms ensuring stable setpoint maintenance across all parameters
  • Integrated safety interlocks: audible alarm activation and automatic shutdown upon detection of sensor fault, flow obstruction, or condensate overflow
  • Upgraded dual-capacitive RH sensor with ±2% RH accuracy (20–85% RH range) and NIST-traceable calibration support
  • Digital mass flow controller (MFC) with ±1% full-scale repeatability and thermal compensation for ambient drift
  • Front-panel analog potentiometer controls for intuitive, tactile adjustment of flow, temperature, and humidity—no software or PC required
  • On-board digital display showing real-time values for flow (L/min), temperature (°C), and RH (%) with backlighting for low-light environments
  • Modular design supporting optional condensation cooling unit for sub-ambient temperature operation down to 15°C (when paired with external chiller)
  • Heater-assisted humidification circuit that activates only when condensate accumulation is detected—minimizing energy use and preventing water carryover

Sample Compatibility & Compliance

The HCS-501 is compatible with inert and reactive gas streams (e.g., N₂, synthetic air, medical-grade O₂) and supports continuous delivery to downstream instrumentation including dynamic vapor sorption (DVS) analyzers, environmental test chambers, and aerosol generation systems. Its construction meets IEC 61010-1 safety standards for laboratory electrical equipment. The control firmware supports audit trail logging via optional RS-232/485 interface, aligning with GLP and FDA 21 CFR Part 11 requirements when integrated into validated workflows. Humidity and temperature sensors are compliant with ISO 17025 traceability frameworks and may be calibrated per ASTM E2654 (Standard Practice for Calibration of Hygrometers).

Software & Data Management

While fully functional in standalone mode, the HCS-501 provides analog output signals (0–5 V or 4–20 mA) for each controlled parameter—enabling integration with SCADA systems, data loggers, or custom LabVIEW/Python acquisition platforms. Optional serial communication allows remote monitoring and parameter setting via terminal emulation or custom scripts. All operational events—including alarm triggers, auto-shutdowns, and calibration timestamps—are timestamped and stored in non-volatile memory. Exportable logs support CSV formatting for post-hoc analysis and regulatory documentation. No proprietary software license is required for basic operation or data retrieval.

Applications

  • Conditioning inlet air for dynamic vapor sorption (DVS) and moisture sorption isotherm studies
  • Generating defined humidity-temperature profiles for accelerated stability testing per ICH Q1A(R3)
  • Supplying calibrated humidified air to breath simulation systems in inhalation drug development
  • Controlling purge gas environments in thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC)
  • Validating environmental chambers used in packaging permeability testing (ASTM F1249)
  • Providing stable reference air streams for calibration of hygrometers, dew point meters, and particulate monitors

FAQ

Does the HCS-501 require annual recalibration?
Yes—recommended annually for RH and temperature sensors, and biannually for the mass flow controller, using NIST-traceable standards. Calibration certificates are provided upon service.
Can the system operate continuously for 72+ hours without intervention?
Yes—designed for unattended operation under stable lab conditions; internal condensate reservoir capacity supports ≥8 hours of maximum humidification duty cycle.
Is the condensation module included by default?
No—the condensation cooling module is an optional accessory (HCS-CM-20); it must be specified at time of order and requires connection to an external chilled water source or recirculating chiller.
What is the warm-up time to reach steady-state humidity control?
Typically 12–18 minutes from cold start to ±0.5% RH stability at 50% RH and 25°C, depending on initial ambient conditions and selected flow rate.
Are replacement consumables available separately?
Yes—replaceable humidity sensor cartridges (MNR-SR-HUM-01), MFC filter elements (MNR-FIL-MFC-02), and desiccant packs (MNR-DES-03) are stocked and shipped globally.