Empowering Scientific Discovery

Beijing Hope Century Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelHE-480R
Sensor InputSingle-channel (electrode constant: 0.01 cm⁻¹)
Resistivity Range0–0.200 / 0–2.00 / 0–20.0 / 0–100.0 MΩ·cm
Alternate Range0–2.00 / 0–20.0 / 0–200.0 / 0–1000 kΩ·cm
Temperature Range0–100 °C (configurable 1- or 2-digit display)
Repeatability±0.5% (max, equivalent input)
Linearity±0.5% (max, equivalent input)
Output1 × isolated 4–20 mA DC (max load 900 Ω)
Relay Outputs2 × SPDT (240 V AC / 30 V DC, 3 A resistive)
Digital InterfaceRS-485 (2-wire, input/output isolated)
Temp. CompensationPt1000 sensor
Enclosure RatingIP65 (outdoor-rated)
ComplianceCE, FCC, RoHS, WEEE
Compatible SensorsHORIBA ERF-series resistivity sensors (0.01 cm⁻¹)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelB-722
Measurement PrincipleIon-Selective Electrode (ISE) Method
Measurement Range23–2300 ppm (mg/L) [1.0 × 10⁻³ – 1.0 × 10⁻¹ mol/L]
Minimum Sample Volume0.05 mL × 2 or ≥0.3 mL
CalibrationTwo-Point Calibration
Accuracy±10% of reading
Temperature CompensationAutomatic (fixed coefficient: 2%/°C)
Auto-Hold FunctionYes
Ingress Protection RatingIP67
Operating Environment5–40 °C, <85% RH (non-condensing)
Power SupplyTwo CR2032 batteries
Dimensions (L×W×H)164 × 29 × 20 mm (excl. protrusions)
WeightApprox. 50 g (instrument only, batteries excluded)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelB-721
PortabilityPen-type
Measurement PrincipleIon-selective electrode (NaCl-specific)
Salinity Range0.1–10% (w/w NaCl)
Temperature Range5–40 °C
Temperature CompensationAutomatic (2%/°C fixed coefficient)
Accuracy±10% of reading
Resolution0.1%
IP RatingIP67
Power SourceTwo CR2032 batteries
Dimensions164 × 29 × 20 mm (excl. probe tip)
Weight~50 g (instrument only, no batteries)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelOCMA-550 / OCMA-555
Instrument TypePortable
Measurement PrincipleNon-Dispersive Infrared (NDIR) Absorption Spectrophotometry
Extraction SolventOCMA-550 — S-316
Measurement Range0–200 mg/L (water), 0–1000 mg/kg (soil), 0–1 Abs
Repeatability±0.4 mg/L (0–9.9 mg/L), ±2.0 mg/L (10.0–99.9 mg/L), ±4 mg/L (100–200 mg/L), ±1% F.S. (0–1 Abs)
DetectorThermoelectric Sensor
DisplayBacklit LCD with timestamping
InterfaceRS-232C, Parallel Printer Port
Power Supply230 V AC, 50 Hz
Dimensions250 × 200 × 285 mm (W × H × D)
Sample Cell200-mm Pathlength Quartz Cuvette
Standard AccessoriesCovered quartz cuvette, power cord, heavy oil standard (B-grade), 2 A fuse, 10 mL and 25 µL syringes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelENDA-600ZG Series
Instrument TypeContinuous Emission Monitoring System (CEMS)
Accuracy±1.0 %F.S.
Repeatability±0.5 %F.S.
Response Time (SO₂)60–240 s
Stability±2.0 %F.S./week
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelpH-33
Instrument TypePen-style
Parameter TypeSingle-parameter (pH)
Measurement Range0.00–14.00 pH
Resolution±0.01 pH
Accuracy±0.01 pH
Calibration SolutionspH 4.01 and pH 7.00 standard buffers
IP RatingIP67
Electrode TypeIntegrated flat-surface pH electrode
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelSR-305
Dimensions200 mm (W) × 200 mm (D) × 600 mm (H)
Solvents SupportedS-316 and H-997
Power RequirementNone
Regeneration MethodDual-bed Gravity-driven Adsorption Column System
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelU-50 Series
Instrument TypePortable / Handheld Water Quality Analyzer
Measured ParameterspH, ORP, Dissolved Oxygen (DO), Conductivity, Salinity, TDS, Specific Gravity (Seawater), Temperature, Turbidity (NTU), Water Depth (m), GPS Positioning
Turbidity StandardsU-53 — US EPA Method
Turbidity Resolution0.01 NTU
Operating Temperature Range−10 to 55 °C
Waterproof RatingIP68 (JIS Protection Class 8 for probe
Battery LifeUp to 70 hours (alkaline AA × 4, backlight off)
Data Storage10,000 measurement sets
CommunicationUSB
Display320 × 240 monochrome LCD with backlight
Probe DimensionsØ96 mm × 340 mm
Cable LengthStandard 2 m (optional 10 m or 30 m)
Probe MaterialsPPS, glass, SUS316L, SUS304, FKM, PEEK, titanium, FEP membrane, POM
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelB-751
Measurement PrincipleIon-Selective Electrode (ISE) Method
Measuring Range40–4000 ppm (mg/L) [1.0 × 10⁻³ – 1.0 × 10⁻¹ mol/L Ca²⁺]
Minimum Sample Volume0.05 mL × 2 or ≥0.3 mL
CalibrationTwo-Point Calibration
Accuracy±20% of reading
Temperature CompensationAutomatic (2%/°C fixed coefficient)
Auto-Hold FunctionYes
Ingress Protection RatingIP67
Operating Environment5–40 °C, <85% RH (non-condensing)
Power SupplyTwo CR2032 batteries
Dimensions (L×W×H)164 × 29 × 20 mm (excl. protrusions)
WeightApprox. 50 g (instrument only, excl. batteries)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelPH22
Instrument TypePen-Style pH Meter
Parameter TypeSingle-Parameter (pH)
Measurement Range0–14 pH
Resolution±0.01 pH
Accuracy±0.01 pH
Calibration SolutionspH 4.01 and pH 7.00 standard buffers
Temperature CompensationAutomatic (ATC)
Electrode TypeFlat-Surface pH Sensor
Minimum Sample Volume100 µL
ComplianceDesigned for routine compliance with ISO 8655, ASTM D1293, and EPA Method 150.1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelOCMA-310 / OCMA-315
Detection MethodSolvent Extraction + Non-Dispersive Infrared (NDIR) Absorption
Detection Range0–200 mg/L (dynamic, single-range)
Sample MatrixFreshwater, Seawater, Wastewater
Repeatability±0.2 mg/L ±1 digit (0–10 mg/L), ±2 mg/L ±1 digit (10–100 mg/L), ±4 mg/L ±1 digit (100–200 mg/L)
ExtractantOCMA-310 → S-316 (trichloroethylene substitute)
Optional AccessorySolvent Regenerator SR-305 (activated carbon + activated alumina column)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelOCMA-555
Instrument TypePortable
Measurement PrincipleNon-Dispersive Infrared (NDIR) Absorption
Extraction SolventH-997
Measurement Range0–200 mg/L (water), 0–1000 mg/kg (soil), 0–1 Abs
Detection Limit0.1 ppm
Repeatability±0.4 mg/L (0–9.9 mg/L), ±2.0 mg/L (10.0–99.9 mg/L), ±4 mg/L (100–200 mg/L), ±1% F.S. (0–1 Abs)
DisplayBacklit LCD with timestamping
InterfaceRS-232C, Parallel Printer Port
Power Supply230 V AC, 50 Hz
Dimensions250 × 200 × 285 mm (W × H × D)
DetectorThermopile Sensor
Sample Cell200 mm pathlength quartz cuvette
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelU-50 Series
Instrument TypePortable / Handheld Water Quality Analyzer
Measured ParameterspH, ORP, Dissolved Oxygen (DO), Conductivity, Salinity, TDS, Specific Gravity (Seawater), Temperature, Turbidity (LED or Tungsten Lamp), Water Depth (on select models)
Turbidity StandardsUS EPA Method (U-53), EN ISO 7027 (U-54)
Operating Temperature Range−10 to 55 °C
Depth Measurement Rangeup to 30 m (pressure-based, on U-52G/U-53/U-53G/U-54/U-54G)
Waterproof RatingIP67 (host), IP68 (probe)
Display320 × 240 monochrome backlit LCD
Data Storage10,000 measurement sets
PowerFour AA alkaline batteries (≈70 h operation without backlight)
CommunicationUSB
Probe Cable LengthStandard 2 m (optional 10 m or 30 m)
Probe MaterialPPS, SUS316L, SUS304, FKM, PEEK, Titanium, FEP membrane, POM
WeightHost ≈ 800 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelOCMA-555
Instrument TypePortable
Measurement PrincipleNon-Dispersive Infrared (NDIR) Absorption
Extraction SolventH-997
Measurement Range0–200 mg/L (water), 0–1000 mg/kg (soil), 0–1 Abs
Detection Limit0.1 ppm
Repeatability±0.4 mg/L (0–9.9 mg/L), ±2.0 mg/L (10.0–99.9 mg/L), ±4 mg/L (100–200 mg/L), ±1% F.S. (0–1 Abs)
DisplayBacklit LCD with timestamping
InterfaceRS-232C, Parallel Printer Port
Power Supply230 V AC, 50 Hz
Dimensions250 × 200 × 285 mm (W × H × D)
DetectorThermoelectric Sensor
Sample Cell200 mm pathlength quartz cuvette
ComplianceASTM D7678 (oil-in-water by IR), ISO 9377-2, USP <467>, EPA Method 1664 (solvent-extractable oil)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelPMA-51d
Explosion ProtectionEx d IIB+H2 T4 / Ex px d IIC T4X
Measurement PrincipleMagnetic Mechanical (Magnetic Dumbbell Ball Method)
Target GasO₂
Range Options0–5 vol% to 0–100 vol% O₂
Repeatability±0.1 vol% O₂ (standard range)
Linearity±1.0% F.S.
Zero Drift±0.05 vol% O₂/week
Span Drift±0.05 vol% O₂/week
Response Time (T90)≤20 s
Sample Flow Rate300 mL/min
Sample Pressure≥1.98 kPa
Ambient Operating Temperature–10 to +50 °C
Wetted MaterialsSUS304, SUS316, Pt, Borosilicate Glass, FKM, SiO₂, Au
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelF-74 Benchtop
Measurement ParameterspH, ORP, Ion Concentration, Conductivity, Resistivity, Salinity, TDS, Temperature
DisplayDual-channel capacitive touchscreen
Data Storage2000 measurements
ComplianceJIS, USP <645>, EP 2.2.38, JP/CP Pharmacopoeial water standards
Language SupportEnglish, Japanese, Korean, Chinese
Power SupplyAC adapter 100–240 V, 50/60 Hz
Weight700 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
Model SeriesPG-350
Instrument TypePortable
Measured GasesNOₓ, SO₂, CO, CO₂, O₂
Range OptionsO₂: 0–5/10/25 vol%
CO₂0–5/10/25 vol%
Repeatability±1.0% F.S.
Response Time (T₉₀)≤45 s (all gases except SO₂)
Zero/Span Drift±1.0% F.S./day (SO₂: ±2.0% F.S./day)
Linearity Error±2.0% F.S.
Sample Flow Rate~0.5 L/min
DisplayColor TFT-LCD Touchscreen with Real-Time Trend Graphs
Data StorageSD Card (User-Configurable Interval)
Output Interfaces4–20 mA Analog, Ethernet
Warm-up Time≤30 min
Operating Environment5–40 °C, ≤85% RH
Dimensions226 × 265 × 510 mm (W×H×D)
Weight~14 kg
ComplianceMCERTS (UK), TÜV (EU), GOST-R (Russia), EPA ETV (US), CNAS/CMA (China), KOLAS (Korea), JIS (Japan)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelVA-3000 / VS-3000
Instrument TypeOnline Analyzer
Detection PrincipleNDIR, CLA, MPA, Electrochemical (Galvanic), Zirconia
Measurable GasesCO, CO₂, NOₓ, SO₂, CH₄, N₂O, C₂H₄, O₂
Minimum Range1–5 ppm
Repeatability±0.5% F.S.
Resolution0.1 ppm
Response TimeT₉₀ ≤ 30 s
Zero Drift±2.0% F.S./week
Warm-up Time20–60 min (depending on sensor type)
Analog Output0–1 V DC or 4–20 mA (optional)
Communication InterfaceRS-232C
Sample Flow Rate~0.5 L/min
Operating Environment0–40 °C, ≤90% RH
Power SupplyAC 100–120 V or 200–240 V, 50/60 Hz
Dimensions (VA-3000)430 × 132 × 550 mm (W×H×D)
Weight (VA-3000)~20 kg
Enclosure19-inch rack-mountable chassis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelHE-200C
Enclosure RatingIP65
Power Supply90–264 V AC, 50/60 Hz
OutputThree isolated 4–20 mA analog outputs (configurable per parameter)
Relay OutputsThree SPDT dry-contact relays (R1–R3, user-assignable for high/low alarms, USP qualification, or fault indication)
CommunicationRS-485 (2-wire, galvanically isolated input/output circuitry)
Temperature CompensationPt1000 sensor (0 °C reference), 0–100 °C range
Measurement ParametersConductivity (0.000 µS/cm to 200.0 mS/cm, selectable cell constant: 0.01, 0.1, or 1.0 cm⁻¹), TDS (0.00–2000 mg/L, user-defined conversion factor 0.30–1.00), and temperature (0–100 °C, ±0.1 °C accuracy at reference point)
AccuracyConductivity ±0.5% FS (max), TDS ±1.5% FS (max), temperature ±0.5 °C linearity error
RepeatabilityConductivity ±0.5% FS (max), TDS ±1.5% FS (max)
Environmental RatingOutdoor-rated aluminum housing, CE/FCC/WEEE/RoHS compliant
MountingPole-mounted (50A pipe) or wall-mounted
Weight~4.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelHCS-501
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelB-743 Nitrate Pen-Type Ion Meter
Measurement PrincipleIon-Selective Electrode (ISE) Method
Measurement Range (NO₃⁻)62–6,200 ppm (mg/L) [10⁻³–10⁻¹ mol/L]
Measurement Range (NO₃⁻–N)14–1,400 ppm (mg/L)
Minimum Sample Volume0.05 mL × 2 or ≥0.3 mL
CalibrationTwo-Point Calibration
Accuracy±10% of reading
Temperature CompensationAutomatic (fixed 2%/°C coefficient)
Auto-Hold FunctionYes
Ingress Protection RatingIP67
Operating Environment5–40 °C, RH <85% (non-condensing)
Power SupplyTwo CR2032 batteries
Dimensions (L×W×H)164 × 29 × 20 mm (excl. protrusions)
WeightApprox. 50 g (instrument only, excl. batteries)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelFV-250
Detection PrincipleFlame Ionization Detection (FID)
Instrument TypePortable
Detection Range0–10 / 20 / 50 / 100 / 200 / 500 / 1,000 / 2,000 / 5,000 / 10,000 ppmC
Resolution±1.0% FS
Accuracy±1.0% FS
Response Time (T90)< 2.0 seconds
Drift±1.0% FS / 8 h
Linearity±1.0% FS
Sampling Flow Rate~600 mL/min
Warm-up Time~1 h
Operating Temperature5–35 °C
Operating Humidity< 85% RH
Output SignalsDC 0–1 V, RS-232C
Power SupplyAC 100 V, 50/60 Hz
Power Consumption50 VA
Dimensions260(W) × 260(H) × 510(D) mm
Data StorageCompactFlash (CF) card
Safety FeatureAutomatic H₂ shutoff and alarm upon flameout
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelB-711 / B-712
Instrument TypePen-style pH Meter
Parameter TypeSingle-parameter (pH)
Measurement Range2.0–12.0 pH
Resolution0.1 pH
Accuracy±0.1 pH (after calibration, measured in standard buffer solutions)
Calibration OptionsB-711 — single-point (pH 7.0)
Minimum Sample Volume0.05 mL (with optional sampling film B)
Temperature CompensationAutomatic (ATC)
IP RatingIP67 (dust-tight
Operating Environment5–40 °C, ≤85% RH (non-condensing)
Power SupplyTwo CR2032 lithium coin cells
Dimensions (L×W×H)164 × 29 × 20 mm (excl. protrusions)
WeightApprox. 50 g (instrument only, excluding batteries)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelLO-300
Instrument TypeOnline
Detection PrincipleLaser Circular Area Scanning Reflectometry
Detection Range0.3–4.0 m (up to 6.0 m on still water)
Oil Detection TargetFloating/Adherent hydrocarbon films (gasoline, kerosene, diesel, heavy fuel oil, insulating oil, lubricating oil)
Output4–20 mA analog signal (reflected light intensity), 2 dry contact alarms (oil film presence, system level anomaly)
DisplayTouchscreen interface showing oil coverage (%), threshold setting, real-time received light level, status indicators
Power SupplyAC 100 V ±10%, 50/60 Hz, ≤100 VA
Enclosure RatingIP66
Operating Temperature−10 to +50 °C
DimensionsØ185 × 547 mm (H)
Weight~11 kg
OptionalSurveillance camera module (MP4 video recording at 1 or 3 fps
Show next