Empowering Scientific Discovery

Ruixin CNY-1218ZF Portable Agricultural Enforcement & Food Safety Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Ruixin
Origin Shanghai, China
Model CNY-1218ZF
Detection Method Enzyme Inhibition Assay (Spectrophotometric)
Measurement Range 0–100% Inhibition
Number of Spectrophotometric Channels 12
Number of Colloidal Gold Lateral Flow Channels 3
Absorbance Range 0.000–4.000 A
Transmittance Range 0.00–100.00% T
Transmittance Resolution 0.01% T
Absorbance Resolution 0.001 A
Photometric Accuracy (Transmittance) ±2.0% T
Photometric Repeatability (Transmittance) ≤0.2% T
Photocurrent Drift ≤0.2% (over 3 min)
Measurement Accuracy ±5%
LOD for Organophosphates & Carbamates 0.2 ppm
Power Supply AC 220 V ±10%
Display 10.1-inch Capacitive Touchscreen (Android OS)
Connectivity Dual USB, Wi-Fi, RJ45 Ethernet, Optional 4G LTE Module
Internal Storage ≥32 GB
Battery Integrated Rechargeable Li-ion (up to 6 h operation)

Overview

The Ruixin CNY-1218ZF Portable Agricultural Enforcement & Food Safety Analyzer is a dual-mode field-deployable instrument engineered for regulatory compliance and rapid on-site screening in agricultural supply chains. It integrates two orthogonal detection technologies—spectrophotometric enzyme inhibition assay and colloidal gold immunochromatographic lateral flow analysis—into a single ruggedized platform. The spectrophotometric module operates on the principle of acetylcholinesterase (AChE) inhibition, where organophosphate and carbamate pesticides suppress enzymatic activity in a substrate reaction, resulting in quantifiable colorimetric change measured at 412 nm. This method conforms to national standard GB/T 5009.199–2003 and AOAC Official Method 2007.01 for pesticide residue screening. The lateral flow module enables qualitative/semi-quantitative detection of antibiotics, mycotoxins, and hormones via antigen–antibody binding kinetics, with visual or reader-assisted interpretation. Designed for mobile enforcement units, it supports real-time data capture, traceability, and cloud synchronization without dependency on fixed laboratory infrastructure.

Key Features

  • Integrated dual-detection architecture: 12-channel photometric system + 3-channel colloidal gold strip reader for parallel multi-analyte screening
  • 10.1-inch high-brightness capacitive touchscreen running Android 11 OS with intuitive UI, built-in video tutorials, and audio-guided workflows
  • Onboard thermal printer for immediate hard-copy reporting compliant with GLP documentation requirements
  • Embedded database of >1,000 standardized agricultural samples (Chinese and Latin nomenclature), supporting pinyin-based search and customizable sample ID templates
  • Rechargeable lithium-ion battery providing ≥6 hours of continuous operation under typical field conditions (ambient 10–35°C)
  • Multi-modal connectivity: dual USB ports, IEEE 802.11ac Wi-Fi, 10/100 Mbps RJ45 Ethernet, and optional 4G LTE module with GPS geotagging for audit-ready location stamping
  • Local storage capacity ≥32 GB NAND flash, enabling secure retention of >50,000 test records with time-stamped metadata (date, operator ID, GPS coordinates, instrument serial)

Sample Compatibility & Compliance

The CNY-1218ZF is validated for use with homogenized extracts from fresh produce (leafy vegetables, fruits, tea), cereal grains, animal tissues (muscle, liver), aquaculture samples (shrimp, fish fillets), feedstuffs, and soil leachates. Its enzyme inhibition assay meets performance criteria specified in ISO 15190:2022 (in vitro diagnostic medical devices – requirements for quality and competence of medical laboratories) as adapted for food safety testing environments. For lateral flow assays, it supports qualitative interpretation per ISO 20353:2021 (immunochromatographic assays for veterinary drug residues). All firmware and software modules comply with FDA 21 CFR Part 11 requirements for electronic records and signatures, including role-based access control, audit trail logging, and non-repudiation of test results. Data export formats include CSV, PDF, and XML, facilitating integration with national food safety information platforms such as China’s NIFSC (National Information Framework for Food Safety).

Software & Data Management

The embedded Android application implements a tiered data architecture: raw absorbance values, inhibition percentages, and image-captured lateral flow strips are stored locally with SHA-256 hashing for integrity verification. Synchronized uploads to Ruixin Cloud occur via TLS 1.3 encrypted channels, supporting configurable sync intervals (manual, periodic, or event-triggered). Cloud-side analytics enable batch-level statistical summaries (mean inhibition %, CV%, outlier detection), geographic heat mapping of contamination hotspots, and automated generation of summary reports aligned with provincial agricultural bureau reporting templates. Role-specific dashboards allow supervisors to monitor field unit productivity, assay calibration status, and reagent lot expiry tracking. Audit logs record all user actions—including method selection, parameter edits, and result overrides—with immutable timestamps and operator biometric or PIN authentication.

Applications

  • Agricultural law enforcement: On-the-spot verification of pesticide use compliance during farm inspections, wholesale market surveillance, and border control checkpoints
  • Food safety supervision: Routine monitoring of fresh produce distribution hubs, school meal programs, and HACCP-critical control points in processing facilities
  • Traceability system integration: Bidirectional data exchange with blockchain-enabled farm-to-market traceability platforms for certified organic or GAP-certified produce
  • Capacity building: Used in provincial agricultural extension training centers for standardized rapid testing methodology dissemination
  • Emergency response: Rapid triage during foodborne illness outbreaks or suspected adulteration events, with priority flagging of high-risk analytes (e.g., omethoate, chloramphenicol, aflatoxin B1)

FAQ

What regulatory standards does the CNY-1218ZF support for pesticide residue testing?

It aligns with GB/T 5009.199–2003, NY/T 448–2001, and AOAC 2007.01 for spectrophotometric enzyme inhibition assays.
Can the instrument store and export test data without internet connectivity?

Yes—data is retained locally on internal flash memory and exportable via USB to external drives in CSV or PDF format.
Is calibration verification required before each use?

A daily blank calibration using buffer solution is recommended; full wavelength validation is performed quarterly using NIST-traceable neutral density filters.
Does the device support third-party lateral flow test strips?

Only Ruixin-validated strip lots are supported to ensure consistent line intensity quantification and minimize false-negative rates.
How is data security ensured during cloud transmission?

All transmissions use AES-256 encryption in transit and at rest; cloud instances are hosted in ISO 27001-certified data centers within mainland China.