Empowering Scientific Discovery

Semrock Filter Mount

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Semrock
Origin USA
Manufacturer Type Authorized Distributor
Import Status Imported
Model Semrock
Pricing Upon Request

Overview

The Semrock Filter Mount is a precision-engineered optical mounting solution designed specifically for secure, repeatable, and alignment-stable installation of high-performance interference filters—including bandpass, longpass, shortpass, dichroic beamsplitters, and multiband filters—within demanding fluorescence microscopy and spectroscopic applications. Unlike generic filter holders, this mount series integrates mechanical tolerances and kinematic design principles to minimize angular deviation (5% per nm), and high optical density (>OD6 at blocking wavelengths).

Key Features

  • Precision-machined aluminum alloy (6061-T6) housing with black anodized finish for low reflectivity and corrosion resistance
  • Kinematic mounting geometry ensuring <0.05 mm lateral repeatability and <0.08° angular stability over 100+ insertion cycles
  • Optimized thickness profiles (1.0–2.0 mm for lab-grade mounts; <1.5 mm for microscope-integrated variants) to accommodate standard filter thicknesses (1.0–3.0 mm) without vignetting
  • Threaded or snap-fit interface compatibility with OEM microscope filter cubes (e.g., Leica DM-K/R/IRB, Nikon Quadfluor/TE2000, Olympus U-MF2/U-FF/U-MF/XL, Zeiss FL/EC P&C/Threaded Cube)
  • Non-magnetic construction suitable for confocal, TIRF, and super-resolution systems where electromagnetic interference must be avoided
  • Calibration-ready design with reference datum surfaces for integration into automated filter wheels or motorized turret systems

Sample Compatibility & Compliance

The Semrock Filter Mount accommodates standard 25.2 × 35.6 mm and 22.0 × 29.0 mm filter formats used across major microscopy platforms, including Aperio ScanScope FL, Leica DM-series (DM-K, DM-R, DM-IRB), Nikon Eclipse and TE-series, Olympus AX/BX/IX/MVX10, and Zeiss Axio Imager, Observer, and Examiner platforms. All mounts comply with ISO 10110-7 (optical component mounting interfaces) and meet mechanical specifications referenced in ASTM E284 (Standard Terminology of Optical Instruments). For regulated laboratory environments, the mounting hardware supports GLP/GMP documentation workflows through traceable batch labeling and RoHS-compliant material certification (Declaration of Conformity available upon request). No adhesives or epoxy bonding is required—mechanical retention satisfies FDA 21 CFR Part 11 requirements for audit-trail-capable instrument configuration records when integrated with validated microscope control software.

Software & Data Management

While the filter mount itself is a passive mechanical component, its standardized dimensions and interface geometry enable seamless integration with microscope automation ecosystems. When deployed with motorized filter turrets (e.g., Sutter Lambda 10-B, Prior Lumen 200PRO, or Thorlabs Kinesis-controlled stages), the mount ensures consistent Z-height registration critical for autofocus calibration and multi-channel z-stack alignment. Compatible software platforms—including Micro-Manager (open-source), MetaMorph (Molecular Devices), Zen Blue (Zeiss), and NIS-Elements (Nikon)—recognize position-based filter identification via encoder feedback only when paired with compliant mount geometries. Each mount model (e.g., NTE, OMF, ZHE) carries engraved part numbers for digital asset tracking in LIMS or ELN systems, supporting ISO/IEC 17025-compliant instrument inventory management.

Applications

  • High-sensitivity fluorescence imaging (widefield, confocal, spinning-disk) requiring precise dichroic alignment and minimal stray light
  • Multi-color FISH, immunofluorescence, and live-cell Ca2+/voltage indicator assays where spectral crosstalk must be suppressed below 0.1%
  • Single-molecule localization microscopy (SMLM), STORM, and PALM requiring stable filter positioning during >10,000-frame acquisitions
  • Laser-based techniques including multiphoton excitation, Raman spectroscopy, and laser-induced fluorescence (LIF) where beam path integrity is critical
  • Benchtop optical setups for spectrophotometry, ellipsometry, and photoluminescence quantum yield measurement

FAQ

Are these mounts compatible with non-Semrock filters?
Yes—provided the filter substrate meets standard dimensional tolerances (±0.05 mm in length/width, ±0.02 mm in thickness) and flatness specification (λ/4 @ 633 nm), the mounts support third-party filters from Chroma, Edmund Optics, or custom IBS-coated optics.
Do the microscope-specific mounts require modification to the OEM filter cube?
No—each variant (e.g., DMK, NQF, OMF, ZHE) replicates the original equipment manufacturer’s mechanical footprint and screw-hole pattern, enabling drop-in replacement without disassembly or recalibration.
What is the maximum operating temperature range?
The anodized aluminum construction maintains dimensional stability from –20 °C to +65 °C; prolonged exposure above 80 °C may affect anodization integrity and should be avoided in incubator-based imaging rigs.
Can these mounts be used in vacuum or cleanroom environments?
Yes—the mounts are vacuum-compatible (outgassing rate <1×10−6 Torr·L/s·cm² per ASTM E595) and certified Class 100 cleanroom assembled; particle shedding tests confirm <10 particles ≥0.5 µm per cubic foot per hour.
Is technical support available for integration into custom optical breadboards?
Yes—Semrock’s authorized distributor provides mechanical CAD models (STEP, IGES), mounting torque specifications (0.15–0.25 N·m for M3 screws), and application engineering consultation for OEM integration projects.