Empowering Scientific Discovery

Shimadzu Nexlock Finger-Tight Fitting

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Shimadzu
Origin Japan
Manufacturer Type Original Equipment Manufacturer (OEM)
Import Status Imported
Model Nexlock
Pricing Available Upon Request

Overview

The Shimadzu Nexlock Finger-Tight Fitting is an engineered solution for ultra-high-performance liquid chromatography (UHPLC) systems requiring zero-dead-volume, high-pressure integrity, and operator-friendly connectivity. Unlike conventional ferrule-based fittings that rely on metal or polymer compression rings to seal against the outer diameter of tubing—introducing potential voids at the column inlet interface—the Nexlock employs a direct-surface sealing mechanism. This design eliminates radial clearance between the fitting body and the outer surface of the capillary tubing, thereby preventing stagnant flow zones that contribute to peak tailing, band broadening, and carryover in trace-level analyses. Its operational principle centers on axial compression of a precision-machined sealing sleeve that uniformly conforms to the tubing’s OD under finger-tight torque alone, achieving reliable static sealing without tools. Validated for continuous operation at 130 MPa (1300 bar), it meets the mechanical and fluidic demands of modern sub-2-µm particle-packed UHPLC columns and core-shell technologies.

Key Features

  • Finger-tight installation and removal—no wrenches, torque tools, or alignment fixtures required
  • Zero-dead-volume interface: direct tubing surface sealing eliminates voids at column inlet and detector connections
  • High-pressure rating: maintains leak-free performance up to 130 MPa (1300 bar) with hand-tightened torque only
  • Reusability: rated for ≥100 mating cycles without degradation in sealing performance or tubing deformation
  • Tubing replacement capability: compatible with standard 1/16″ OD stainless steel, PEEK, or fused silica capillaries; no need to replace the entire fitting assembly
  • Material compatibility: chemically resistant construction suitable for aqueous, organic, and corrosive mobile phases (e.g., TFA, HFIP, high-pH buffers)
  • Consistent reproducibility: eliminates variability introduced by inconsistent wrench-torque application across operators and shifts

Sample Compatibility & Compliance

The Nexlock fitting supports all standard 1/16″ OD chromatographic tubing used in HPLC, UHPLC, and LC-MS workflows—including stainless steel, PEEK, and fused silica—with internal diameters ranging from 50 µm to 500 µm. It is fully compatible with Shimadzu Nexera and LC-VP series instruments, as well as third-party UHPLC platforms meeting ISO 8503-1 surface roughness specifications for tubing interfaces. The fitting complies with ISO 9001 manufacturing controls and supports GLP/GMP environments through documented reusability validation and traceable batch certification. While not a regulated device per se, its design facilitates compliance with FDA 21 CFR Part 11 requirements by enabling consistent, operator-independent connection protocols—reducing procedural deviation risk during method transfer and routine QC testing.

Software & Data Management

As a passive mechanical component, the Nexlock fitting does not incorporate embedded electronics, firmware, or software interfaces. However, its implementation directly impacts data quality metrics tracked within chromatography data systems (CDS), including peak symmetry (As), retention time stability (RSD < 0.1%), and system suitability test (SST) pass rates. Laboratories using Empower, Chromeleon, LabSolutions, or OpenLab CDS can document Nexlock usage via instrument configuration logs and maintenance records. Its repeatable sealing behavior contributes to reduced column-to-column and run-to-run variability—key parameters audited during FDA inspections and ISO/IEC 17025 accreditation assessments. Optional serialized lot tracking is available upon request for full traceability in regulated environments.

Applications

  • UHPLC method development and validation where peak shape fidelity and low detection limits are critical
  • LC-MS coupling requiring minimal extra-column volume to preserve sensitivity and resolution
  • High-throughput screening workflows demanding rapid column changes and tubing swaps without recalibration
  • Pharmaceutical QC labs performing compendial assays per USP , EP 2.2.46, or JP 6.02
  • Environmental and food safety testing involving complex matrices and gradient elution methods
  • Academic and contract research laboratories optimizing separation efficiency under extreme backpressure conditions

FAQ

What tubing materials are compatible with the Nexlock fitting?
Stainless steel, PEEK, and fused silica capillaries with 1/16″ (1.59 mm) outer diameter are fully supported.
Can the Nexlock fitting be used with older HPLC systems operating below 600 bar?
Yes—it is backward-compatible and provides enhanced sealing consistency even at lower pressures, reducing maintenance frequency.
Is cleaning or maintenance required between uses?
No routine cleaning is needed; however, visual inspection of the sealing sleeve and tubing end for particulate or scratch damage is recommended prior to reuse.
Does the fitting require calibration or periodic verification?
No calibration is necessary; however, laboratories may include pressure-hold testing (e.g., 100 MPa for 5 min) as part of preventive maintenance SOPs.
How does Nexlock compare to traditional Vespel or graphite ferrules in terms of lifetime?
Unlike single-use or limited-cycle ferrules, Nexlock is validated for ≥100 reuses with consistent torque response and leak integrity—reducing consumables cost and waste generation.

InstrumentHive