Empowering Scientific Discovery

testo Saveris 2-T1 WiFi Temperature Data Logger

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand testo
Origin Germany
Model 0572 2031
Channel Count Single-channel
Measurement Range −30 to +50 °C
Accuracy ±0.5 °C
Resolution 0.1 °C
Storage Capacity 10,000 readings
IP Rating IP65
Battery 4 × AA (24-month typical life at +25 °C, 15-min interval)
Wireless Protocol MQTT over Wi-Fi (WEP/WPA/WPA2/WPA2 Enterprise supported)
Time Sync SNTP-capable
Compliance EN 12830 certified (TÜV-tested)
Cloud Communication Interval 1 min – 24 h (Advanced license)
Operating Temperature −30 to +50 °C
Dimensions 95 × 75 × 30.5 mm
Weight 240 g

Overview

The testo Saveris 2-T1 WiFi Temperature Data Logger is a CE-marked, TÜV-certified (EN 12830) single-channel wireless monitoring device engineered for continuous, unattended temperature surveillance in regulated and non-regulated environments. It integrates a high-stability NTC sensor directly into its sealed housing and operates autonomously via standard AA batteries, delivering long-term measurement integrity without external probes or wired infrastructure. Data acquisition follows a configurable measurement cycle—ranging from 1 minute to 24 hours—and is transmitted securely over IEEE 802.11 b/g/n Wi-Fi networks using the lightweight MQTT protocol, ensuring low-bandwidth efficiency and compatibility with enterprise-grade authentication methods including WPA2 Enterprise and certificate-based TLS handshaking. All measurements are time-stamped via SNTP synchronization to maintain traceable, audit-ready timestamps across distributed deployments. Designed for cold chain validation, pharmaceutical storage, food logistics, laboratory incubators, and HVAC performance verification, the Saveris 2-T1 meets foundational requirements for GLP-compliant environmental monitoring where documented temperature continuity is mandatory.

Key Features

  • Integrated NTC temperature sensor with ±0.5 °C accuracy across −30 to +50 °C range and 0.1 °C digital resolution
  • IP65-rated enclosure for dust-tight and water-jet resistant operation in demanding industrial and warehouse settings
  • Configurable measurement and transmission intervals—1 min to 24 h—enabled by cloud license tier (Basic or Advanced)
  • MQTT-based encrypted data transmission supporting WEP, WPA, WPA2, and WPA2 Enterprise security protocols
  • On-device LCD display showing real-time temperature, battery status, alarm state, and Wi-Fi connectivity indicator
  • 10,000 internal measurement storage capacity with automatic overwrite logic; no local SD card or USB dependency
  • Standard 4×AA battery design with up to 24 months service life under nominal conditions (+25 °C, 15-min cycle); user-replaceable without tools
  • TÜV-certified per EN 12830 for use in refrigerated transport, cold rooms, and pharmaceutical storage applications

Sample Compatibility & Compliance

The testo Saveris 2-T1 is intended for ambient air temperature monitoring only; it does not support immersion, surface, or probe-based measurements. Its fixed-sensor architecture ensures mechanical stability and eliminates calibration drift associated with detachable probe cables. The device complies with EN 12830:2018 for electronic temperature recorders used in refrigerated transport and storage, and its firmware architecture supports ALCOA+ principles (Attributable, Legible, Contemporaneous, Original, Accurate, Complete, Consistent, Enduring, Available) for data integrity. While not inherently 21 CFR Part 11 compliant out-of-the-box, the Advanced cloud service enables audit trail generation, electronic signatures, and role-based access control—prerequisites for GxP-aligned deployments. Validation documentation—including factory calibration report and EN 12830 conformity statement—is provided with each unit.

Software & Data Management

Data management occurs exclusively through the testo Cloud platform, accessible via web browser or native iOS/Android apps. The Basic plan (free) provides manual PDF/CSV export, 3-month rolling data retention, and single-user access. The Advanced subscription adds automated report scheduling, API integration (RESTful endpoints for ERP/LIMS ingestion), 2-year data retention, multi-user collaboration (up to 10 licensed users), and extended alarm logic—including delay timers, alarm suppression windows, and cascaded notifications for battery depletion, signal loss, or power interruption. All cloud interactions are logged with immutable timestamps and user attribution, satisfying GLP audit requirements. No on-premise server installation is required; system configuration, threshold definition, and device fleet management occur entirely through the web interface.

Applications

  • Pharmaceutical cold chain monitoring: Continuous validation of vaccine refrigerators, pharmacy coolers, and distribution center holding areas
  • Food safety compliance: HACCP-critical zone logging in walk-in freezers, prep tables, and delivery vehicles
  • Laboratory environmental control: Incubator, stability chamber, and cleanroom ambient temperature trending
  • Facility HVAC verification: Baseline thermal mapping and seasonal performance benchmarking
  • Archival compliance: Long-term temperature history for ISO 17025-accredited testing laboratories
  • Remote site surveillance: Unstaffed warehouses, remote clinics, and field-deployed storage units with limited IT infrastructure

FAQ

Is the testo Saveris 2-T1 suitable for use in frozen environments below −20 °C?
Yes—the device is rated for continuous operation from −30 to +50 °C. For sustained sub-zero deployment, Energizer Ultimate Lithium AA batteries (model 0515 0572) are recommended to ensure reliable power delivery at low temperatures.
Can I integrate Saveris 2-T1 data into my existing LIMS or SCADA system?
Only with the Advanced cloud license, which includes a documented REST API for programmatic data retrieval, alarm event streaming, and metadata synchronization.
Does the device support external sensors or analog inputs?
No—the Saveris 2-T1 is a single-channel, fixed-sensor instrument. For multi-parameter or probe-based monitoring, consider the Saveris 2-T2 (dual-channel with external probe input) or Saveris 2-H1 (temperature/humidity variant).
How is time synchronization maintained across multiple loggers?
All units perform periodic SNTP queries against configurable NTP servers, ensuring sub-second timestamp alignment across geographically dispersed installations.
What happens if Wi-Fi connectivity is temporarily lost?
Measurements continue locally and are queued in the 10,000-entry buffer. Once connectivity resumes, buffered data is transmitted in chronological order with original timestamps preserved.