Titan UC-10 10L Benchtop Ultrasonic Cleaner with Heated Tank and Digital Timer
| Brand | Titan |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dedicated Ultrasonic Cleaner |
| Tank Capacity | 10 L |
| Ultrasonic Frequency | 35 kHz |
| Ultrasonic Power Output | 200 W |
| Adjustable Power | No |
| Temperature Control Range | 20–69 °C |
| Timer Range | 1–99 minutes |
| Sound-Dampening Lid | Included |
| Drain & Fill Fitting | Integrated |
Overview
The Titan UC-10 is a benchtop ultrasonic cleaner engineered for consistent, repeatable cleaning of precision laboratory components—including glassware, metal parts, surgical instruments, microfluidic devices, and analytical sample holders. It operates on the principle of acoustic cavitation: high-frequency sound waves (35 kHz) generate microscopic vacuum bubbles in the cleaning solution, which collapse violently upon contact with surfaces—dislodging particulate contaminants, organic residues, and biofilms without mechanical abrasion. Designed for routine QC/QA labs, R&D facilities, and medical device reprocessing units, the UC-10 delivers stable energy output and thermal control across extended cycles, supporting reproducible cleaning validation protocols aligned with ISO 13485 and ASTM D2603-20.
Key Features
- Stainless steel tank (304 grade) with 10-liter working volume, optimized for uniform acoustic field distribution and corrosion resistance in aqueous and mild solvent-based solutions.
- Digital microprocessor controller with independent adjustment of temperature (20–69 °C, ±1 °C accuracy) and timer (1–99 min, 1-min increments), enabling precise parameter locking for SOP-driven workflows.
- Fixed-frequency 35 kHz transducer array bonded to the tank bottom—engineered for high energy transfer efficiency and long-term stability under continuous operation.
- Integrated sound-dampening lid with safety interlock: automatically suspends ultrasonic output when opened, reducing ambient noise to <55 dB(A) at 1 m and enhancing operator comfort during multi-hour runs.
- Front-panel drain valve and fill port facilitate rapid solution exchange and residue-free tank maintenance—critical for cross-contamination prevention between sample batches.
- No power-level modulation; 200 W nominal output ensures consistent cavitation intensity across all operating conditions—eliminating variability introduced by manual power ramping.
Sample Compatibility & Compliance
The UC-10 accommodates a broad range of labware geometries: beakers up to 150 mm diameter, test tubes, pipette tips, crucibles, and small-scale filtration assemblies. Its non-aggressive cleaning mechanism preserves surface integrity of delicate optics, anodized aluminum, and coated sensors. The unit complies with IEC 61000-6-3 (EMC emissions) and IEC 61000-6-2 (immunity), and meets CE marking requirements for laboratory equipment. While not certified for sterile processing per ISO 17664, it supports pre-sterilization cleaning steps compliant with AAMI ST79:2023 Annex B and USP guidance on cleaning validation. Routine use with deionized water or low-foaming alkaline detergents satisfies GLP documentation standards for instrument logbooks and cleaning records.
Software & Data Management
The UC-10 operates via embedded firmware with no external software dependency—ensuring operational continuity in regulated environments where IT validation overhead must be minimized. All setpoints (temperature, time) are retained after power cycling. Though lacking USB or Ethernet connectivity, its digital interface provides traceable, auditable parameter entry: each cycle start logs the selected settings into non-volatile memory, supporting manual recordkeeping for FDA 21 CFR Part 11–aligned audits when paired with lab notebook entries. Optional calibration certificates (NIST-traceable temperature sensor verification) are available upon request for IQ/OQ documentation packages.
Applications
- Cleaning of HPLC autosampler vials, GC liners, and syringe filters prior to chromatographic analysis.
- Removal of solder flux, machining oils, and polishing compounds from precision machined components in metrology labs.
- Preparation of TEM grids and SEM stubs for electron microscopy—minimizing carbon contamination versus manual wiping.
- Routine decontamination of reusable pipette tips and electrophoresis combs in molecular biology workflows.
- Supporting ASTM E2877-22 (Standard Guide for Ultrasonic Cleaning Validation) through controlled, documented parameter sets.
FAQ
Is the UC-10 suitable for cleaning delicate optical lenses or coated mirrors?
Yes—provided compatible low-surface-tension, non-etching cleaning solutions (e.g., 1% Alconox® in DI water) are used and immersion time does not exceed 10 minutes at ≤45 °C.
Does the unit include a degassing function?
No—the UC-10 lacks automatic degas mode; users should manually deaerate solutions by running the unit empty for 5–10 minutes before loading samples.
Can the temperature overshoot during heating cycles?
No—the PID-controlled heater maintains setpoint within ±1 °C tolerance without overshoot, verified across 100+ thermal cycles per unit during factory QA.
What maintenance is required for long-term reliability?
Annual inspection of transducer bond integrity and tank weld seams is recommended; replace the drain gasket every 24 months or after 500 cycles.
Is the UC-10 compatible with flammable solvents?
No—this model is rated exclusively for aqueous and water-miscible solutions; use only in well-ventilated areas, never with acetone, ethanol, or chlorinated hydrocarbons.