Empowering Scientific Discovery

Vacuubrand MZ 2C NT Chemical-Resistant Dual-Stage Diaphragm Vacuum Pump

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Origin Germany
Manufacturer Type Authorized Distributor
Origin Category Imported
Model MZ 2C NT
Instrument Type Diaphragm Vacuum Pump
Product Type Oil-Free Vacuum Pump
Maximum Flow Rate 2.0 m³/h
Ultimate Vacuum (Absolute) 7 mbar
Ultimate Vacuum with Gas Ballast Enabled 12 mbar
Dimensions (L×W×H) 243 × 243 × 198 mm
Weight 11.1 kg
Ordering Code 732300

Overview

The Vacuubrand MZ 2C NT is a dual-stage, oil-free diaphragm vacuum pump engineered for demanding chemical laboratory environments where corrosion resistance, vapor tolerance, and long-term operational reliability are critical. Operating on positive displacement via elastomeric diaphragms driven by an eccentric cam mechanism, the MZ 2C NT achieves stable vacuum generation without lubricating oils—eliminating risk of sample contamination and simplifying maintenance. Its two-stage compression architecture enables higher ultimate vacuum performance compared to single-stage counterparts while maintaining robust pumping speed across a broad pressure range (7–1000 mbar). Designed specifically for compatibility with condensable vapors generated during rotary evaporation, solvent removal, freeze-drying, and vacuum drying, the pump integrates a precisely calibrated gas ballast valve that introduces controlled ambient air into the second stage to prevent condensate accumulation and maintain volumetric efficiency. All wetted parts—including diaphragms, valves, and chamber linings—are constructed from chemically inert fluoropolymers (primarily PTFE and FPM), ensuring compatibility with aggressive solvents (e.g., acetone, chloroform, THF, concentrated acids and bases) and reactive vapors.

Key Features

  • Chemically resistant fluoropolymer-wetted components (PTFE diaphragm “sandwich” design with reinforced elastomer core for enhanced fatigue resistance and extended service life)
  • Dual-stage configuration delivering 2.0 m³/h maximum flow rate and 7 mbar ultimate vacuum (absolute) without gas ballast
  • Integrated gas ballast system enabling reliable operation with condensable vapors; maintains 12 mbar ultimate vacuum when activated
  • Ultra-low vibration and acoustic emission (<50 dB(A)) due to balanced motor design and elastomeric mounting
  • Sealed, maintenance-free drive mechanism with brushless AC motor and lifetime-lubricated bearings
  • Compact footprint (243 × 243 × 198 mm) and lightweight construction (11.1 kg) for benchtop integration in multi-instrument vacuum networks

Sample Compatibility & Compliance

The MZ 2C NT is validated for continuous use with volatile organic solvents, aqueous acidic/basic solutions, and halogenated compounds commonly encountered in synthetic chemistry, pharmaceutical development, and materials science workflows. Its fluoropolymer fluid path meets ISO 8573-1 Class 0 purity requirements for oil-free compressed air/vacuum systems and complies with EU Directive 2014/30/EU (EMC) and 2014/35/EU (LVD). While not intrinsically rated for explosive atmospheres, it is suitable for installation in standard laboratory ventilation environments per EN 14175-3. The pump supports GLP-compliant documentation protocols when integrated with compatible vacuum controllers (e.g., Vacuubrand VACUU·SELECT) featuring audit-trail-capable firmware.

Software & Data Management

As a standalone analog pump, the MZ 2C NT does not incorporate embedded digital controls or native software connectivity. However, it is fully interoperable with Vacuubrand’s ecosystem of smart vacuum controllers—including the VACUU·SELECT and VACUU·LAN series—which provide real-time pressure monitoring, programmable setpoint control, data logging (CSV export), and remote operation via Ethernet or USB. When paired with such controllers, the system supports 21 CFR Part 11–compliant electronic records through optional user authentication, electronic signatures, and immutable audit trails—enabling traceability in regulated QC/QA laboratories.

Applications

  • Routine vacuum support for rotary evaporators (e.g., Heidolph, IKA, Büchi) handling heat-sensitive compounds
  • Primary vacuum source for vacuum ovens (e.g., Memmert, Binder) and desiccators requiring chemical-resistant evacuation
  • Integrated vacuum supply for centrifugal concentrators, gel dryers, and lyophilizers processing corrosive or high-vapor-pressure samples
  • Gas scavenging and inert atmosphere purging in Schlenk line auxiliary systems
  • Pre-vacuum conditioning of HPLC degassers and mass spectrometer inlets in analytical labs

FAQ

Is the MZ 2C NT suitable for pumping hydrogen chloride (HCl) gas?
Yes—the PTFE/FPM fluid path provides excellent resistance to anhydrous HCl at ambient temperatures and moderate partial pressures; however, prolonged exposure to humidified HCl or condensed hydrochloric acid should be avoided.
Can this pump be mounted vertically?
No—Vacuubrand specifies horizontal orientation only to ensure proper diaphragm actuation geometry and thermal management; vertical mounting voids warranty and risks premature diaphragm failure.
What is the expected diaphragm service life under typical lab usage?
Under continuous operation with non-condensing loads, PTFE diaphragms typically exceed 10,000 hours; with intermittent use and vapor-laden duty cycles, 6,000–8,000 hours is typical—monitoring vacuum stability and flow consistency is recommended as a maintenance indicator.
Does the MZ 2C NT require periodic oil changes?
No—it is a fully oil-free design; no lubricants contact the pumped gas stream or internal compression chambers.
Is an exhaust filter included or required?
An optional activated carbon exhaust filter (Vacuubrand part # 701000) is recommended when exhausting solvent vapors indoors to comply with local occupational health regulations (e.g., OSHA PELs, EU Directive 2004/37/EC).