| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WH-02 |
| Heating Method | Air-jacketed |
| Cooling Method | Peltier Thermoelectric |
| Convection Type | Forced-air |
| Temperature Range | +4 °C to 60 °C (at 20 °C ambient) |
| Temperature Stability | ±0.1 °C |
| Temperature Uniformity | <±0.6 °C at 37 °C and 25 °C RT |
| Capacity | 50 L |
| External Dimensions (W×D×H) | 440 × 550 × 618 mm |
| Internal Dimensions (W×D×H) | 335 × 370 × 380 mm |
| Heating Power | 300 W |
| Cooling Power | 350 W |
| Power Supply | AC 220–240 V, 50/60 Hz |
| Net Weight | 35 kg |
| Controller | TFT Touchscreen with PID Algorithm |
| Timer Range | 1 min – 999 hr 59 min or Continuous |
| Programmable Profiles | 4 multi-step ramp/soak programs (5 steps each) |
| Fan Speed Control | 0–100% continuous adjustment |
| Safety Features | Overheat protection, overcurrent protection, door-open alarm (1 min delay), auto fan/heater shutoff on door opening |
Overview
The WIGGENS WH-02 Pro Low-Temperature Biochemical Incubator is an engineered solution for precise, stable, and contamination-controlled temperature environments in life science laboratories. Designed for applications requiring tight thermal regulation between +4 °C and 60 °C—including cell culture maintenance, enzyme activity assays, microbial growth studies, and stability testing of biopharmaceutical intermediates—the WH-02 Pro employs a solid-state Peltier thermoelectric cooling system integrated with air-jacketed resistive heating. Unlike compressor-based systems, this architecture eliminates refrigerant use, mechanical vibration, oil migration, and high acoustic emissions—critical advantages in sensitive imaging setups, shared core facilities, and GLP-compliant QC labs. The forced-air convection system, driven by a digitally adjustable centrifugal fan (0–100% speed control), ensures rapid thermal equilibration and uniform distribution across the 50 L chamber, validated to <±0.6 °C at both 25 °C and 37 °C reference points under standard operating conditions.
Key Features
- Peltier-based thermoelectric cooling: Zero ozone-depleting refrigerants, no moving parts in the cold stage, and minimal heat rejection into the lab environment
- Air-jacketed stainless-steel heating elements: Rapid thermal response, corrosion resistance, and simplified decontamination protocols
- TFT touchscreen controller with embedded PID algorithm: Real-time temperature curve logging, user-adjustable screen brightness, and intuitive profile programming
- Four independent programmable temperature profiles: Each supports up to five sequential ramp-and-soak steps for complex incubation protocols (e.g., circadian rhythm simulation or thermal stress preconditioning)
- Auto-start and auto-stop functionality: Configurable behavior following power interruption—enables unattended overnight operation with fail-safe recovery logic
- Comprehensive safety architecture: Dual-stage overtemperature cutoff, electronic overcurrent protection, door-open interlock (fan and heater disabled immediately; audible alarm triggered after 60 s), and automatic data-logged event timestamps for all alarms
Sample Compatibility & Compliance
The WH-02 Pro accommodates standard tissue culture flasks (T25–T175), Petri dishes (up to 150 mm), multiwell plates (6–96-well), and glass vials without spatial interference. Its interior chamber—constructed from electropolished 304 stainless steel—supports routine ethanol wiping, hydrogen peroxide vapor (HPV) decontamination cycles, and optional high-temperature dry-heat sterilization (via accessory module). The device complies with IEC 61010-1:2010 for laboratory electrical equipment safety and meets EMC requirements per EN 61326-1:2013. While not certified as a medical device, its performance characteristics align with common validation benchmarks referenced in ISO 13408-2 (aseptic processing) and USP (biological assay validation), making it suitable for pre-clinical research and process development under GxP-aligned quality systems.
Software & Data Management
Temperature data is continuously sampled at 10-second intervals and stored internally for up to 30 days (circular buffer). The built-in event log records timestamps for all operator actions (e.g., setpoint changes, program starts/stops), alarm triggers (high/low temp, door open, power loss), and system diagnostics (fan RPM, Peltier voltage/current). Export is supported via USB flash drive in CSV format—compatible with LIMS integration and statistical process control (SPC) tools. Audit trail functionality satisfies basic ALCOA+ principles (Attributable, Legible, Contemporaneous, Original, Accurate), though full 21 CFR Part 11 compliance requires external validation and supplementary electronic signature infrastructure.
Applications
- Mammalian and insect cell line maintenance at physiological temperatures (37 °C ±0.1 °C) with minimized CO2-independent pH drift
- Low-temperature enzymatic reactions (e.g., restriction digests, ligations) requiring strict +4 °C stabilization
- Long-term storage of temperature-sensitive reagents, antibodies, and primary cell isolates
- Microbial growth kinetics under controlled thermal gradients (e.g., E. coli thermal adaptation studies)
- Stability assessment of protein formulations per ICH Q5C guidelines (real-time and accelerated conditions)
- Pre-incubation of samples prior to downstream analytical workflows (HPLC injection, flow cytometry, qPCR setup)
FAQ
What is the maximum ambient temperature for rated performance?
The specified temperature range (+4 °C to 60 °C) assumes a stable ambient environment of 20 °C ±2 °C. At 25 °C ambient, the minimum achievable temperature increases to approximately +6 °C; consult the technical datasheet for derating curves.
Can the WH-02 Pro be validated for IQ/OQ/PQ?
Yes—the unit provides stable, repeatable thermal performance with documented traceable calibration points. A factory-issued certificate of conformance and sensor location map are supplied; users must perform site-specific mapping per ISO 14644-3 or EU GMP Annex 15 protocols.
Is humidity control available?
No. The WH-02 Pro is a non-humidified incubator. For moisture-sensitive applications, consider pairing with external desiccant chambers or selecting the WH-02 Humidity variant (separate model).
How often does the Peltier module require maintenance?
The thermoelectric cooler has no consumables or scheduled service intervals. Routine cleaning of rear ventilation grilles every 6 months is recommended to maintain thermal efficiency.
Does the device support RS-232 or Ethernet connectivity?
No. Communication is limited to USB mass storage export. Remote monitoring or SCADA integration requires third-party hardware gateways and custom scripting.