| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | 1301–1305 |
| Power Supply | 24 V DC (for solenoid valve) |
| Sensor Type | Dual PT100 Resistance Temperature Detectors (RTDs), calibrated for cryogenic range (−196 °C) |
| Control Output | Relay + solid-state switching for 24 V solenoid valve actuation |
| Alarm Interface | Visual LED indicators + audible buzzer (85 dB @ 10 cm) |
| Enclosure Rating | IP65 |
| Operating Ambient Temperature | 0 °C to 40 °C |
| Compliance | CE-marked, RoHS-compliant, designed per IEC 61000-6-2/6-4 EMC standards |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | 13365-05 / 13365-10 / 13370-10 |
| Speed Range | 50–10,000 rpm |
| Air Supply | 35–100 psi |
| Power Output | 0–1/6 hp (13365-05/10), 0–1/3 hp (13370-10) |
| Air Consumption | up to 13 cfm |
| Stainless Steel Shaft | Ø9.5 mm × 305 mm (13365), Ø12.7 mm × 305 mm (13370) |
| Impeller Diameter | 64 mm |
| Material | AISI 316 stainless steel (standard), PTFE impellers optional |
| Compliance | ATEX-ready design for hazardous environments |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | 2755-25 |
| Configuration | Includes SL29GL-A glass cold trap, Dewar vessel, lid, exhaust tubing, and 25 L LN₂ storage tank |
| Compliance | Designed for cryogenic vacuum applications requiring stable condensation surface temperature and reproducible low-temperature operation |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | 2760-25 |
| Application | Cryogenic Sample Immersion & Thermal Contraction Testing |
| Includes | 25 L LN₂ Storage Dewar, Dual Temperature Sensors, Control Unit, Transfer Tubing, Vent Line, Two Sample Supports |
| Power Supply | 24 V DC |
| Valve Type | Solenoid Valve (24 V DC) |
| Sensor Principle | Cryogenic Temperature Threshold Detection |
| Compliance | Designed for GLP-aligned laboratory environments |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | 2760-35 |
| Storage Tank Capacity | 35 L |
| Control Principle | Dual-Temperature-Sensor Feedback with 24 V Solenoid Valve Actuation |
| Power Supply | 24 V DC |
| Sensor Type | Immersion Thermistors (High/Low Level) |
| Compliance | Designed for GLP-compliant low-temperature process control in laboratory and industrial settings |
| Brand | WIGGENS |
|---|---|
| Origin | Shanghai, China |
| Model | A410 |
| Pump Type | Dual-Stage Diaphragm Pump |
| Ultimate Vacuum | ≤13 mbar |
| Flow Rate | ≤25 L/min |
| Motor Speed | 1450 rpm |
| Dimensions (W×D×H) | 230 × 155 × 173 mm |
| Weight | 4.5 kg |
| Rated Power | 95 W |
| Noise Level | 50 dB(A) |
| Power Supply | 220–240 V / 50 Hz |
| Inlet/Outlet Port | 10 mm ID |
| Protection | Thermal Overload Cut-Off |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | A410 |
| Pump Type | Diaphragm Vacuum Pump |
| Oil-Free Operation | Yes |
| Ultimate Vacuum | 13 mbar |
| Flow Rate | 25 L/min |
| Dimensions (W×D×H) | 230 × 155 × 173 mm |
| Weight | 10 kg |
| Motor Power | 95 W |
| Motor Speed | 1450 rpm |
| Noise Level | 50 dB(A) |
| Inlet/Outlet Port Size | 10 mm |
| Electrical Supply | 220–240 V, 50 Hz |
| Rated Current | 0.6 A |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Pump Type | Diaphragm Vacuum Pump |
| Ultimate Vacuum | 8 mbar |
| Pumping Speed | 40 L/min |
| Dimensions (W×D×H) | 290 × 190 × 210 mm |
| Weight | 10 kg |
| Motor Power | 245 W |
| Noise Level | ≤50 dB(A) |
| Motor Speed | 1450 rpm |
| Electrical Supply | 220–240 V / 50 Hz |
| Rated Current | 1 A |
| Inlet/Outlet Port Diameter | 10 mm |
| Protection Features | Thermal Overload Cut-off, Integrated Fuse |
| Construction | PTFE-wetted Parts, Dual-Stage Design |
| Optional Accessories | Corrosion-Resistant Vacuum Regulator Filter Kit, Analog Vacuum Gauge, Digital Vacuum Meter DVM150C with Filter Assembly |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | AL |
| Price Range | USD 700 – 2,800 |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | ALU |
| Type | Vacuum-Insulated Aluminum Alloy Cryogenic Dewar |
| Capacity Range | 10–100 L |
| Operating Pressure | 0.5 bar (gauge) |
| LN₂ Evaporation Rate | 0.18–0.56 L/day |
| Static Hold Time | 72–180 days |
| Construction | Multi-layer vacuum insulation with aluminum alloy composite shell |
| Compliance | Designed per ISO 21028-1 (cryogenic vessels for transport and storage), PED 2014/68/EU (pressure equipment directive) applicable to low-pressure cryogenic containers |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | ALU-CD-DMT |
| Capacity | 12–35 L |
| Operating Temperature | –196 °C (liquid nitrogen) |
| Maximum Pressure | 0.5 bar |
| Evaporation Rate | 0.2–0.3 L/day |
| Includes | Loosely Fitting Evaporation-Reducing Lid, Carry Handle or Side Handle, NW50 KF Flange Port, Long-Reach Cryogenic Scoop with Mounting Bracket |
| Optional | Bottom-Mounted Swivel Casters (Order Codes: 2640-CD, 2641-CD) |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | APOLLO |
| Capacity Options | 49.5–348 L |
| Operating Overpressure | 1.3–2.0 bar |
| Static Evaporation Rate | 0.2–0.5 %/day |
| Vacuum Insulation | Multi-layer Cryogenic Vacuum Jacket |
| Construction | Austenitic Stainless Steel (ASTM A240 304/316) |
| Neck Opening | KF50 Flange |
| Compliance | Meets PED 2014/68/EU, EN 13445-3, ISO 21028-1 for Cryogenic Vessels |
| Standard Features | Integrated Safety Relief System, Vacuum-Lock Quick-Release Clamps, Pneumatic-Free Self-Pressurization Kit, Dual-Valve LN₂ Transfer Hose with Phase Separator & Exhaust Valve, Immersion Depth-Optimized Neck Geometry, Integrated Level Gauge with Mechanical Dial Indication |
| Mobility | Heavy-Duty Swivel Casters (125 mm or 160 mm), Reinforced Perimeter Frame |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | ARPEGE A40 |
| Capacity | 40 L |
| Static Evaporation Rate | 0.30 %/day |
| Empty Weight | 25 kg |
| Full Weight | 57 kg |
| Total Height | 735 mm |
| Canister Diameter | 467 mm |
| 2 mL Vial Capacity | 750 (with standard racks) |
| Vacuum Insulation | Multi-layer cryogenic vacuum jacket |
| Interface Options | 4–20 mA / RS485 + MEMO data logging (optional) |
| Safety Features | Vacuum safety valve, integrated level & temperature indicators |
| Optional Accessories | Castor base, rack support stands, 76×76 mm and 133×133 mm cryoboxes |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | atexMIX |
| Stirrer Type | Magnetic Drive Stirrer |
| Speed Range | 100–2,000 rpm |
| Power Output | 20 W |
| Speed Control Resolution | 1 rpm |
| Power Settings | 4-step (25/50/75/100%) |
| Enclosure Material | Aluminum / Plastic (atexMIX) or Aluminum (atexMIX cleanroom) |
| Protection Rating | IP65 |
| ATEX Certification | II 2G EEx de IIC T6 (atexMIX), II 3G Ex nAC IIC T6 (atexMIX cleanroom) |
| Operating Environment | 0–40 °C, ≤80% RH |
| Input Voltage | 100–240 V AC, 50/60 Hz, 1.5 A |
| Dimensions (W×D×H) | 360 × 460 × 200 mm (atexMIX), 210 × 55 × 30 mm (atexMIX cleanroom) |
| Weight | ~15 kg (atexMIX), 3.6 kg (atexMIX cleanroom) |
| Optional Interfaces | 0–10 V analog output, 4–20 mA analog output, RS232, USB, Ethernet |
| Compliance | ATEX Directive 2014/34/EU, IEC 60079-0, IEC 60079-1, IEC 60079-15 |
| Software Integration | Customizable control software available |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | atexMIXcontrol / atexMIXcontrol cleanroom |
| Stirrer Type | Electromagnetic Induction Magnetic Stirrer |
| Max. Stirring Volume | 4 L |
| Speed Range | 100–2000 rpm |
| Temperature Control Range | 0–40 °C |
| Power Output Steps | 25/50/75/100% (4-step) |
| Input Power | 100–240 V, 50–60 Hz, 1.5 A |
| Enclosure Material | Anodized Aluminum / Plastic (atexMIXcontrol), Aluminum (atexMIXcontrol cleanroom) |
| Dimensions (W×D×H) | 360 × 460 × 200 mm / 210 × 55 × 30 mm |
| Weight | ~15 kg / 3.6 kg |
| IP Rating | IP65 |
| ATEX Certification | II 2G EEx de IIC T6 (99200) / II 3G Ex nAC IIC T6 (99300) |
| Cert. No. | KEMA 03 ATEX 2045 / EPS 10 ATEX 1246 X |
| Operating Environment | 0–40 °C, ≤80% RH |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | atexMIXdrive |
| Stirrer Type | Electromagnetic Induction Magnetic Drive Stirrer |
| Max. Stirring Volume | 10 L |
| Temperature Operating Range | 0–40 °C (at ≤80% RH) |
| Enclosure Material | Stainless Steel (AISI 316L) |
| Sealing Material | PUR (ATEX-compliant) |
| IP Rating | IP68 |
| ATEX Certification | II 2G Ex mb IIC T4, Certificate No. EPS 09 ATEX 1 196 X |
| Power Supply | 48 V DC |
| Dimensions (W×D×H) | 180 × 180 × 38 mm |
| Weight | 3.5 kg |
| Stirring Power | ≤20 W |
| Soft-Start Duration | Adjustable 10–60 s |
| Interface Options (Optional) | 0–10 V, 4–20 mA, RS232, USB, Ethernet |
| Compliance | ATEX Directive 2014/34/EU, IEC 60079-0, IEC 60079-11 |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Autoloop Pro |
| Sterilization Time Range | 1–15 s |
| Cooling Time Range | 1–45 s |
| Control | Microprocessor-based with LED display & optical sensor feedback |
| Rotation Capacity | 1–4 loops |
| Flame Intensity | 2 adjustable levels |
| Auto-shutdown | 15 min / 1 h |
| Rotation Direction | Adjustable (left/right) |
| Construction | Stainless steel housing with heat-resistant tempered glass display cover |
| Dimensions (W×D×H) | 135 × 180 × 305 mm |
| Weight | 1200 g |
| Compliance | Designed for ISO 13485-aligned lab workflows, compatible with GLP/GMP documentation requirements via timestamped operation logs |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Autoloop Pro |
| Sterilization Method | Flame-based (compatible with WIGGENS Fuego Bunsen burners) |
| Control System | Microprocessor-controlled with LED interface |
| Loop Capacity | 1–4 loops |
| Sterilization Time Range | 1–15 s (adjustable in 1-s increments) |
| Cooling Time Range | 1–45 s (adjustable in 1-s increments) |
| Auto-Shutdown | Yes (configurable: 15 min or 1 hr) |
| Rotation Direction | Bidirectional (left/right selectable) |
| Flame Intensity | Two preset levels |
| Status Indication | Dual-color LED (red = hot, green = cooled) |
| Construction | Stainless steel housing with heat-resistant tempered glass display cover |
| Dimensions (W×D×H) | 135 × 180 × 305 mm |
| Weight | 1200 g |
| Compliance | Designed for GLP-compliant microbiological workflows |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model Series | B / C / BE / CAL |
| Construction | Vacuum-insulated double-walled stainless steel or painted steel |
| Capacity Range | 2.6 L to 28 L |
| Liquid Nitrogen Holding Time | Up to 71 hours |
| LN₂ Evaporation Rate | 1.2–1.9 L/day |
| Dry Ice Consumption Rate | 0.4–0.6 kg/day |
| Outer Dimensions (L×W×H) | 120×132×150 mm to 250×280×750 mm |
| Net Weight | 1.5–16 kg |
| Compliance | Designed for ISO 13485-aligned laboratory cold chain workflows, compatible with GLP/GMP sample transport documentation |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | BIOCEN 22 |
| Instrument Type | Benchtop Centrifuge |
| Category | Refrigerated High-Speed Centrifuge |
| Maximum Speed | 15,000 rpm |
| Maximum RCF | 21,885 × g |
| Maximum Capacity | 4 × 750 mL (with swing-out rotor, not standard for microcentrifuge configuration) |
| Standard Microcentrifuge Configuration | 24 × 2 mL |
| Dimensions (W × D × H) | 276 × 390 × 272 mm |
| Weight | 17 kg |
| Power Supply | 220–230 V, 50–60 Hz |
| Power Consumption | 360 W |
| Noise Level | <60 dB(A) |
| Temperature Range | Not applicable (non-refrigerated variant per primary spec |
| note | description conflates BIOCEN 22 with refrigerated models — this unit is *ambient-temperature microcentrifuge* |
| Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDR) |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | BIOCEN 22R |
| Instrument Type | Benchtop Refrigerated Centrifuge |
| Speed Range | Up to 18,100 rpm |
| Max RCF | 31,865 × g |
| Max Capacity | 8 × 15 mL |
| Temperature Range | −20 °C to +40 °C |
| Dimensions (W×D×H) | 276 mm × 640 mm × 272 mm |
| Noise Level | <60 dB(A) |
| Refrigerant | R449A |
| Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6, 2011/65/EU, 2012/19/EU, 2014/30/EU, 2014/35/EU, 98/79/EC, (EC) No 1005/2009, (EU) No 517/2014 |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Biocen24 |
| Centrifuge Type | Benchtop Centrifuge |
| Speed Range | 200–15,000 rpm (10 rpm increments) |
| Max RCF | 21,380 × g (10 × g increments) |
| Speed Accuracy | ±20 rpm |
| Max Capacity | 5 mL × 18 |
| Compatible Tubes | 0.2 mL, 0.5 mL, 1.5 mL, 2 mL, 5 mL microtubes & PCR strips (8 × 4) |
| Temperature Rise at 15,000 rpm | ≤10 °C (rotor only, 60 min runtime) |
| Drive Motor | Brushless DC motor |
| Acceleration/Deceleration Time | 25 s / 25 s |
| Noise Level | ≤64 dB(A) |
| Dimensions (L×W×H) | 364 × 280 × 266 mm |
| Weight | 6 kg |
| Power Supply | AC 110–120 V, 50/60 Hz, 8 A |
| Power Consumption | 200 W |
| Safety Features | Dual interlocked lid, overspeed protection, overtemperature monitoring, imbalance detection, real-time diagnostics |
| Rotor Material | Anodized high-strength aluminum alloy |
| Autoclavable | Yes (121 °C, 20 min, 1.0 kg/cm², unlimited cycles) |
| Biocontainment | Triple high-temp silicone sealing rings |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | BioMIX Control / MS4 |
| Instrument Type | Magnetic Stirrer |
| Speed Range | 2–250 rpm |
| Temperature Operating Range | 0–40 °C (at 80% RH) |
| IP Rating | IP20 (Controller), IP68 (Drive Units) |
| Power Output | 40 W (BioMIX Control), 6 W per position (MS4, up to 4 positions) |
| Interface Options (Optional) | 0–10 V, 4–20 mA, RS232, USB, Ethernet |
| Compliance | Designed for GLP-compliant bioprocessing environments |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | BioMIX Control / BioMIX Control MS4 |
| Stirrer Type | Magnetic Drive Stirrer |
| Max. Stirring Volume | 5 L |
| Speed Range | 2–250 rpm |
| Power Output | 40 W (BioMIX Control) / 6 W per channel × 4 channels (MS4) |
| Power Adjustment | 10 levels (10–100%) |
| Display | Digital speed & power setting |
| Interface Options (optional) | 0–10 V, 4–20 mA, RS232, USB, Ethernet |
| Enclosure Material | Stainless steel (AISI 304) |
| Operating Temp. | 0–40 °C @ ≤80% RH |
| Input Power | 100–240 V AC, 50/60 Hz, 1.5 A |
| IP Rating | IP20 |
| Dimensions (W×D×H) | 200 × 155 × 38 mm |
| Weight | 1.3 kg (BioMIX Control), 2.5 kg (MS4) |
| Compliance | CE, RoHS |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | BIOMIX Drive 1 / BIOMIX Drive 4 |
| Instrument Type | Magnetic Stirrer |
| Max. Stirring Volume | 5 L per position |
| Speed Range | 2–250 rpm |
| IP Rating | IP68 |
| Operating Temperature | −10 °C to +50 °C (100% RH) |
| Power Supply | 48 V DC |
| Housing Material | Stainless Steel (AISI 316L-grade equivalent) |
| Weight | 2.3 kg (Drive 1), 4.7 kg (Drive 4) |
| Enclosure Dimensions | 180 × 180 × 38 mm (Drive 1), 270 × 270 × 38 mm (Drive 4) |
| Motor Type | Maintenance-Free MAG Stepper Motor |
| Stirring Position Spacing | 140 mm (Drive 4 only) |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | BioMIX1 |
| Stirrer Type | Magnetic Drive Stirrer |
| Max. Stirring Volume | 5 L |
| Speed Range | 2–250 rpm |
| IP Rating | IP64 |
| Operating Temperature | −10 to 50 °C (at ≤80% RH) |
| Power Supply | 100–240 V, 50–60 Hz, 1.5 A |
| Housing Material | Stainless Steel (304) |
| Dimensions (W×D×H) | 180 × 230 × 38 mm |
| Weight | 1.4 kg |
| Motor Type | Maintenance-Free MAG Stepper Motor |
| Display & Control | Integrated LED Interface |
| Certifications | CE, RoHS, IEC 61000-6-3/6-4 |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WCI-850CH |
| Temperature Range | Ambient +5 to 60 °C |
| Temp. Uniformity | ±1 °C at 37 °C |
| Humidity Range | 20–95% RH |
| CO₂ Range | 0–20% |
| CO₂ Accuracy | ±0.3% at 5% (37 °C) |
| Shaking Speed | 30–250 rpm |
| Speed Accuracy | ±1 rpm |
| Amplitude | 25 mm |
| Chamber Volume | 850 L |
| Chamber Dimensions (W×D×H) | 700 × 800 × 1530 mm |
| Shelf Dimensions | 520 × 520 mm |
| Power Supply | 220 V, 50/60 Hz |
| Weight | 393 kg |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | BioVac 225 Plus |
| Ultimate Vacuum | 100 mbar |
| Maximum Flow Rate | 800–1000 mL/min |
| Dimensions | 37 × 15 × 25 cm |
| Weight | 4.3 kg |
| Waste Bottle Capacity | 1000 mL × 1 |
| Filtration | 0.2 µm PTFE disc filter |
| Sterilization | Autoclavable (121 °C, 20 min) |
| Foot Switch | Included |
| Oil-Free Vacuum Pump | Yes |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | BioVac 225 |
| Vacuum Level | ≥100 mbar |
| Flow Rate | ≤25 L/min |
| Weight | 4.3 kg |
| Dimensions (L×W×H) | 37 × 15 × 25 cm |
| Waste Bottle Capacity | 1000 mL (1 pc) |
| Filtration | 0.2 µm PTFE disc filter |
| Sterilization | Autoclavable (waste bottle & filter) |
| Foot Switch | Included |
| Accessories | 4 suction sets |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | BioVac 225 |
| Ultimate Vacuum | 100 mbar |
| Maximum Flow Rate | 17 L/min |
| Dimensions | 37 × 15 × 25 cm |
| Weight | 4.3 kg |
| Power Consumption | 25 W |
| Vacuum Type | Diaphragm Pump |
| Waste Bottle Capacity | 1000 mL |
| Filtration | 0.2 µm PTFE Disc Filter |
| Sterilization Compatibility | Autoclavable (121 °C, 20 min) |