Empowering Scientific Discovery

WTW MPP IDS Multi-Parameter Deep-Water Sensor Probe

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand WTW
Origin Germany
Model MPP IDS
Instrument Type Portable Multi-Parameter Water Quality Sensor
Measurable Parameters pH / ORP, Temperature, Dissolved Oxygen (DO), Conductivity, Turbidity
Probe Interface Digital IDS (Intelligent Digital Sensor) interface supporting up to three simultaneous IDS-compatible probes

Overview

The WTW MPP IDS is a high-integrity, submersible multi-parameter sensor probe engineered for precise in-situ water quality monitoring in deep-water environments—including lakes, reservoirs, rivers, estuaries, and wastewater treatment basins. Designed around WTW’s proprietary Intelligent Digital Sensor (IDS) platform, the MPP IDS functions as a modular digital hub that communicates directly with calibrated, plug-and-play IDS probes via a standardized digital bus. Unlike analog sensor systems, the IDS architecture eliminates signal degradation over cable length, ensures automatic probe recognition, and embeds calibration data, serial number, and sensor-specific correction algorithms directly within each probe’s memory. This architecture supports traceable, repeatable measurements compliant with ISO 5667-3, EN ISO 7888 (conductivity), ISO 5814 (DO), and ISO 7027 (turbidity), making the MPP IDS suitable for regulatory monitoring programs and long-term environmental assessment studies.

Key Features

  • Digital IDS interface enabling hot-swappable, auto-recognized probe integration—no manual configuration or zero-point adjustment required
  • Robust stainless-steel housing rated IP68 and pressure-resistant to 100 m depth (10 bar), validated per IEC 60529 and DIN EN 61000-6-2 for electromagnetic compatibility
  • Integrated temperature sensor (Pt1000) with ±0.1 °C accuracy, used for real-time compensation across all measured parameters
  • Low-power consumption design optimized for extended deployment on battery-powered sondes or data loggers (e.g., WTW IQ SENSOR NET or portable meters like Multi 3630 IDS)
  • Non-fouling optical turbidity sensor (ISO 7027-compliant, 860 nm LED) and luminescent dissolved oxygen (LDO) technology eliminating membrane drift and electrolyte maintenance
  • Onboard diagnostics including probe health status, signal stability indicators, and timestamped calibration history accessible via IDS protocol

Sample Compatibility & Compliance

The MPP IDS is validated for use in freshwater, brackish water, and low-salinity seawater (up to 20 g/L TDS). Its probe selection supports methodologically appropriate measurement techniques: glass-electrode-based pH/ORP sensing per ISO 10523 and ASTM D1293; four-electrode conductivity measurement per ISO 7888; and dual-wavelength compensated turbidity detection aligned with EPA Method 180.1. All connected IDS probes undergo factory calibration traceable to NIST-certified reference standards. The system supports GLP-compliant data integrity through embedded audit trails—calibration events, firmware updates, and sensor swaps are automatically logged with user ID, timestamp, and digital signature when interfaced with WTW’s LabX software or IQ SENSOR NET controllers.

Software & Data Management

When integrated with WTW’s IDS-enabled instruments (e.g., Multi 3630 IDS, IQ SENSOR NET base units, or mobile field tablets), the MPP IDS delivers fully structured data streams via Modbus RTU or WTW’s native IDS binary protocol. Data export supports CSV, XML, and direct import into LIMS platforms compliant with ASTM E1482 and ISO/IEC 17025 requirements. Firmware updates and sensor diagnostics are performed remotely using WTW’s IDS Configuration Tool, which enforces version-controlled parameter locking and prevents unauthorized configuration changes—a critical capability for auditable QA/QC workflows under ISO 9001 and EU Water Framework Directive reporting frameworks.

Applications

  • Vertical profiling of stratified water columns in eutrophic lakes and reservoirs
  • Regulatory compliance monitoring at wastewater discharge points and intake structures
  • Long-term ecological trend analysis in protected aquatic habitats (e.g., Natura 2000 sites)
  • Calibration validation and field verification of fixed online analyzers
  • Research-grade hydrochemical surveys requiring synchronized, depth-resolved parameter acquisition
  • Emergency response deployments during spill incidents or algal bloom events

FAQ

Can the MPP IDS operate continuously underwater for extended periods?

Yes—the probe is rated for permanent submersion at depths up to 100 m and features corrosion-resistant materials (1.4404 stainless steel, EPDM seals) certified per DIN EN ISO 1461 for hot-dip galvanizing resistance. Continuous operation requires compatible power/data logging infrastructure.
Is it possible to mix IDS probes from different WTW product generations?

All IDS probes manufactured since 2012 are backward- and forward-compatible with the MPP IDS hub, provided firmware versions are ≥ v3.2. Legacy analog probes require an IDS adapter module and are not supported natively.
Does the MPP IDS meet FDA 21 CFR Part 11 requirements for electronic records?

The MPP IDS itself is a sensor hardware component and does not store or sign records. However, when paired with WTW’s LabX or IQ SENSOR NET systems configured with electronic signatures, audit trails, and role-based access control, full Part 11 compliance is achievable for regulated pharmaceutical or drinking water applications.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0