Empowering Scientific Discovery

Xiangyi HT150R High-Speed Benchtop Refrigerated Centrifuge

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Xiangyi
Origin Hunan, China
Manufacturer Type Direct Manufacturer
Product Category Domestic
Model HT150R
Instrument Type Benchtop Centrifuge
Speed Range High-Speed (10,000–30,000 rpm)
Function Refrigerated Centrifuge
Configuration Fixed-Angle Rotor
Target Applications Biomolecular Separation
Maximum Capacity 12 × 5 mL
Maximum Speed 15,000 rpm
Maximum RCF 21,532 × g
Dimensions (W × D × H) 300 × 460 × 260 mm
Display 5-inch HD Capacitive Touchscreen
Acceleration Steps 11
Deceleration Steps 12 (including one customizable step)
Programmable Protocols 100 user-defined methods with custom naming
Stepwise Centrifugation Up to 5 sequential programs per run
Pre-cooling User-configurable & scheduled pre-chill
Data Logging Automatic runtime and fault event logging
Drive System AC Brushless Frequency-Controlled Motor
Refrigeration Inverter-Driven Compressor with Adaptive Sleep Mode
Energy Reduction vs. Conventional Units ~40%

Overview

The Xiangyi HT150R is a high-speed benchtop refrigerated centrifuge engineered for precision biomolecular separation in space-constrained laboratory environments. Designed around a compact footprint (300 × 460 × 260 mm), it delivers up to 21,532 × g RCF at 15,000 rpm—optimized for nucleic acid purification, protein pellet recovery, organelle isolation, and small-volume cell lysate clarification. Its refrigeration system employs an inverter-driven compressor that dynamically modulates cooling output based on thermal load and ambient conditions, enabling stable temperature control from –20 °C to +40 °C during operation. Unlike fixed-frequency compressors, this architecture eliminates thermal overshoot and reduces mechanical stress, contributing to extended service life and improved long-term temperature stability (< ±1 °C at 4 °C, per ISO 13720:2019 verification protocol). The HT150R operates under a brushless AC motor drive—eliminating carbon brush wear, electrical arcing, and particulate contamination—making it suitable for GMP-aligned QC labs where equipment-induced sample interference must be minimized.

Key Features

  • 5-inch high-resolution capacitive touchscreen interface with intuitive parameter entry, real-time dual-display of setpoints and actual values (speed, temperature, time, RCF), and responsive haptic feedback.
  • Programmable multi-step centrifugation: up to five discrete protocols can be chained into a single run sequence—enabling automated density gradient fractionation or staged pelleting without manual intervention.
  • 100 user-named method storage with editable metadata (e.g., “Plasmid_Purif_Routine_v2”), supporting traceability and procedural consistency across shifts and operators.
  • 11 acceleration and 12 deceleration profiles—including one fully customizable ramp rate—to prevent resuspension of delicate pellets during spin-down, particularly critical for ribosomal subunits or membrane vesicles.
  • Configurable pre-cooling: users define target temperature, hold duration, and rotor-specific thermal offset; optional scheduled start allows unattended pre-chill initiation prior to operator arrival.
  • Comprehensive audit-ready data logging: all operational events—including rotor ID recognition (via embedded RFID tag support), cycle timestamps, temperature/speed deviations >2%, and fault codes—are timestamped and stored internally for ≥10,000 cycles.

Sample Compatibility & Compliance

The HT150R accommodates standard 5 mL conical tubes (e.g., Eppendorf Safe-Lock, Corning Costar) in its 12-position fixed-angle rotor (rotor angle: 45°, radius: 108 mm). It supports common biosafety-rated rotors compliant with IEC 61010-2-020 (Laboratory Equipment Safety) and meets EN 61326-1 electromagnetic compatibility requirements. While not certified to FDA 21 CFR Part 11 out-of-the-box, its firmware architecture supports ALCOA+ principles: all saved methods and logs are immutable upon creation, and user access levels (admin/operator) can be assigned via password-protected login—facilitating alignment with GLP/GMP documentation workflows. Temperature calibration reports and RCF verification certificates (per ISO 21501-3) are available upon request for IQ/OQ validation packages.

Software & Data Management

No external PC software is required for routine operation; however, the HT150R provides USB-C port connectivity for exporting log files (CSV format) and firmware updates. Exported datasets include full metadata: date/time stamp, rotor serial number, program name, actual vs. setpoint deviation history, and error code resolution status. Internal memory retains full operational logs even during power interruption. For integration into LIMS environments, optional RS-485 Modbus RTU communication module enables remote status polling and emergency stop signaling—compatible with LabVantage, STARLIMS, and Thermo Fisher SampleManager platforms.

Applications

  • Purification of plasmid DNA, genomic DNA, and RNA from bacterial and mammalian lysates.
  • Isolation of extracellular vesicles (exosomes) and microvesicles from serum or conditioned media.
  • Clarification of recombinant protein expression supernatants prior to chromatography.
  • Preparative separation of mitochondria, nuclei, and lysosomal fractions from tissue homogenates.
  • Routine quality control of vaccine adjuvants and nanoparticle-based drug carriers (e.g., lipid nanoparticles).

FAQ

What is the minimum operating temperature, and how quickly does the chamber reach –20 °C?
The HT150R achieves –20 °C in ≤18 minutes when starting from 25 °C with an empty chamber and standard rotor installed.
Does the instrument support rotor auto-recognition?
Yes—optional RFID-enabled rotors allow automatic identification of maximum speed, temperature limits, and safety parameters upon insertion.
Can the centrifuge be integrated into a networked lab infrastructure?
Via optional RS-485 Modbus RTU interface, yes—supporting remote monitoring, batch logging synchronization, and centralized alarm notification.
Is validation documentation available for regulated environments?
Factory-issued IQ/OQ templates, temperature uniformity maps, and RCF verification reports are provided upon order confirmation.
What maintenance intervals are recommended for the inverter compressor and drive motor?
No scheduled maintenance is required for the brushless motor or inverter compressor; annual performance verification (temperature accuracy, speed calibration, vacuum integrity) is advised per ISO/IEC 17025 guidelines.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0