Purification Equipment
Filter
Showing 271–300 of 360 results
| Brand | New Biolink |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Membrane Pilot Testing System |
| Pricing | Upon Request |
| Sample Processing | Wastewater Treatment |
| Membrane Types Supported | Ceramic & Organic (Polymeric) Membranes |
| Configurable MWCO Range | 1 kDa – 500 kDa |
| Operating Pressure Range | Up to 10 bar |
| Feed Capacity | 5–100 L per batch |
| System Architecture | Skid-mounted, Modular, Benchtop-to-Pilot Scale |
| Brand | New Biolink |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | NF-Series |
| Pricing | Available Upon Request |
| Sample Processing | Industrial Wastewater & Process Streams |
| Molecular Weight Cut-Off (MWCO) | 100–1000 Da |
| Membrane Charge | Surface-Charged (Donnan Exclusion Dominant) |
| Divalent Ion Rejection | >90% (e.g., SO₄²⁻, Ca²⁺, Mg²⁺) |
| Monovalent Ion Rejection | 10–40% (e.g., Na⁺, Cl⁻) |
| Operating Temperature Range | 5–45 °C |
| Max Inlet Pressure | 25 bar |
| Feed pH Range | 3–11 |
| Membrane Material | Polyamide Thin-Film Composite (TFC) |
| System Configuration | Benchtop Skid-Mounted with Recirculation Loop, Pressure Control, and Permeate Monitoring |
| Brand | New Biolink |
|---|---|
| Model | UHP-RO Series |
| Max Operating Pressure | 20 MPa |
| Membrane Type | High-Pressure Tolerant RO Element with Open-Channel Feed Spacer |
| Feed Compatibility | High-Salinity Wastewater (TDS up to 120,000 mg/L) |
| Recovery Rate | ≥75% (system-dependent) |
| Origin | Beijing, China |
| Application | Laboratory-Scale Wastewater Concentration and Brine Minimization |
| Brand | NORMAG |
|---|---|
| Origin | Germany |
| Model | DSV80 |
| Operating Pressure Range | 760 mbar to 1×10⁻³ mbar |
| Max. Heating Temperature | 250 °C |
| Feed Rate | 0.3–1 kg/h |
| Construction Material | High-purity quartz glass (Duran®-grade) |
| Vacuum Jacket | Ultra-high vacuum silvered insulation (10⁻⁶ mbar) |
| Visual Observation | Full-length vertical sight strip |
| Thermal Compensation | Expansion-compensating corrugated section |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | ODS620 |
| Pricing | Available Upon Request |
| Brand | Ontech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Ontech820 |
| Pricing | Upon Request |
| Brand | Ottesens |
|---|---|
| Origin | Tianjin, China |
| Model | MTN-5800 / MTN-5800A |
| Heating Method | Water Bath |
| Temperature Range | Ambient to 96 °C |
| Temperature Stability | ±0.2 °C |
| Tube Diameter Compatibility | 10–29 mm (standard) / 30–55 mm (optional) |
| Gas Flow Rate | 0–25 L/min |
| Sample Positions | 12 or 24 |
| Heating Power | 1000 W |
| Control Type | Manual (MTN-5800) / Motorized Vertical Adjustment (MTN-5800A) |
| Safety Features | Auto water-level cutoff, drain valve, overheat protection |
| Brand | Deepflow |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Origin | Domestic (China) |
| Model | CY0G0TNP2 |
| Pricing | Available Upon Request |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | P500 |
| Pricing | Available Upon Request |
| Brand | PECULIAR |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Omniapure CN |
| Purified Water Grade | ASTM Type III |
| Resistivity | 18.2 MΩ·cm at 25°C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <3 ppb |
| Microbial Count | <0.001 EU/mL |
| Particulates (>0.1 µm) | <1 particle/mL |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SDC-1000 |
| Instrument Type | Nitrogen Blow-Down Concentrator |
| Temperature Range | Ambient +5°C to 100°C (±0.3°C) |
| Temperature Control Accuracy | ±0.3°C |
| Sample Capacity | 1–12 positions |
| Nitrogen Pressure Range | 0–0.10 MPa (10 adjustable steps, 0.01 MPa increment) |
| External N₂ Supply Pressure | 0.20–0.80 MPa |
| Max. Gas Consumption | ~500 mL/min per channel at 0.10 MPa |
| Endpoint Detection | Optical dryness sensor per channel |
| Endpoint Volumes | 1.0 mL, 0.5 mL, or near-dry (~0.1 mL) |
| Timer Range | 0–9999 min |
| Heating Power | 2000 W |
| Dimensions | 600 × 540 × 400 mm |
| Weight | 28 kg |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-180 |
| Heating Method | Electric (stainless steel heating element) |
| Cooling Method | Recirculating water cooling |
| Distillation Speed | 5–8 min per 250 mL sample |
| Warm-up Time | 10–15 min |
| Endpoint Control | Quantitative volume detection + automatic termination |
| Heating Power | Adjustable up to 1500 W |
| Distillation Flow Rate | 15–30 mL/min |
| Sample Capacity | ≤20 g (solid) or ≤30 mL (liquid) per run |
| Nitrogen Measurement Range | 0.1–240 mg N |
| Recovery Rate | >99.5% |
| Repeatability | RSD ≤0.5% |
| Data Storage | 10 programmable distillation/acid-addition protocols |
| Safety Features | Real-time liquid level monitoring, overpressure protection, dry-run prevention, emergency stop |
| Housing Material | Molded ABS engineering plastic (acid- and alkali-resistant) |
| Tubing | Custom corrosion-resistant polymer tubing (rated for long-term HCl/NaOH exposure) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Water Supply Requirement | ≥0.15 MPa pressure, inlet temperature <20 °C |
| Net Weight | 15 kg |
| Dimensions (W×D×H) | 370 × 300 × 680 mm |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-3800 |
| Instrument Type | Quartz Glass Distillation Apparatus |
| Heating Method | Electric heating (stainless steel heating element) |
| Cooling Method | Recirculating water cooling |
| Distillation Rate | 15–30 mL/min (adjustable) |
| Heating-up Time | 10–15 min |
| End-point Control | Quantitative volume-based automatic termination |
| Steam Power | 750–1500 W (adjustable) |
| Dimensions | ~370 × 300 × 680 mm |
| Housing Material | Acid- and alkali-resistant ABS |
| Nitrogen Detection Range | 0.1–210 mg per sample |
| Sample Capacity | ≤5 g solid or ≤15 mL liquid per run |
| Distillation Time per Sample | 3–9 min |
| RSD | ≤0.5% |
| Recovery Rate | ≥99.5% |
| Reagent Dispensing Accuracy | ±0.05 mL |
| Titration Range | 0–99 mL standard acid (with 10× acid replacement capability) |
| Display | 10.1-inch touchscreen with Chinese UI |
| Data Output | Thermal printer + USB export + LIMS-compatible interface |
| Safety Features | Dry-run protection for steam generator, condensate flow & temperature monitoring, reagent level sensing, safety door & digestion tube presence detection, condensate interruption shutdown |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GWB-1 / GWB-1super / GWB-2 |
| Purified Water Grade | ASTM Type I (Ultra-Pure) |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Total Organic Carbon (TOC) | ≤ 5 ppb |
| Bacterial Count | < 1 CFU/1000 mL |
| Particulates (>0.22 µm) | < 1 /mL |
| Endotoxin | < 0.001 EU/mL |
| Cation/Anion Residue | < 0.1 ppb |
| Key Components | Imported RO Membrane, Imported Ultra-Purification Cartridge, Imported Final-Stage 0.22 µm Filter |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | GWB-1T/2T, GWB-1E/2E |
| Pricing Range | USD 12,500 – 21,000 (FOB Beijing) |
| Water Grade | ASTM Type I / ISO 3696 Grade 1 / CLSI EP28-A3c Class I |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | ≤ 5 ppb |
| Microbial Count | < 1 CFU/1000 mL |
| Endotoxin | < 0.001 EU/mL |
| Particles (>0.1 µm) | < 1 particle/mL |
| Flow Rate (Pure Water Reservoir) | 5 L/min |
| Flow Rate (Ultra-Pure Water Dispense) | 2 L/min |
| Ion Removal Efficiency (Anions/Cations) | < 0.1 ppb residual |
| Brand | Polytech |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | JF-602 Plus |
| Pricing | Available Upon Request |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Model | PrepElite-GVS |
| Flow Rate | 0.1–100 mL/min (intelligently adjustable) |
| Maximum Pressure | ≥1 MPa |
| Flow Stability | RSD ≤1% (at constant flow) |
| Auto-Sampling Volume Range | 0.1–1000 mL |
| Auto-Sampling Capacity | Up to 96 samples per batch |
| System Architecture | Modular, fully enclosed, 24/7 unattended operation |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Model | puriFlash® 5.250 |
| Maximum Flow Rate | 250 mL/min |
| Maximum Pressure | 250 bar |
| Import Category | Imported Instrument |
| Distributor Type | Authorized Distributor |
| Pricing | Available Upon Request |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Model | puriFlash® 5.250P |
| Maximum Flow Rate | 125 mL/min |
| Maximum Pressure | 250 bar |
| Application Focus | Complex Peptide Mixture Separation |
| Import Status | Imported Instrument |
| Distributor Type | Authorized General Distributor |
| Pricing | Available Upon Request |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Model | puriFlash® 5.400-UV |
| Maximum Flow Rate | 125 mL/min |
| Maximum Pressure | 400 bar |
| UV Detection | Integrated Dual-Wavelength UV/Vis Detector |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Model | puriFlash® XS 520 Plus |
| Max Flow Rate | 300 mL/min |
| Max Operating Pressure | 20 bar |
| Type | Medium-Pressure Preparative LC System |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Model | puriFlash®5.015‐XL |
| Max Flow Rate | 825 mL/min |
| Max Operating Pressure | 15 bar |
| Scale | Process to Kilo-Lab (up to 1–5 kg purified material per run) |
| Compliance | CE, ISO 9001-certified manufacturing |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Model | puriFlash®535-XL |
| Max Flow Rate | 400 mL/min |
| Max Pressure | 35 bar |
| Import Status | Imported Instrument |
| Distributor Type | Authorized General Distributor |
| Pricing | Upon Request |
| Brand | PYNN |
|---|---|
| Origin | USA |
| Model | EVAPT 5 |
| Instrument Type | Vacuum-Free Centrifugal Concentrator |
| Key Patents | US 8,061,056 B2 (Self-Generated Blow-Down Technology) |
| Operating Temperature Range | 0–55 °C |
| Timer Range | 0–1000 min |
| Dimensions | 20.3 cm × 30.5 cm × 45.7 cm (W×D×H) |
| Sample Capacity Options | 6×20 mL scintillation vials |
| Brand | Raykol |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | MPE |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Volume Capacity | 1–200 mL |
| Brand | Rocker |
|---|---|
| Origin | Taiwan |
| Model | WelVac200 |
| Housing Material | Anodized Aluminum |
| Collection Tray Material | Polycarbonate (PC) |
| Sealing Gasket & O-Rings | Silicone Rubber |
| Luer Connectors | Silicone |
| Compatible Tubing ID | 8 mm (5/16") |
| Dimensions (Internal) | 128 × 86 × 73 mm (L×W×H) |
| Dimensions (External) | 232 × 124 × 102 mm (L×W×H) |
| Net Weight | 2.6 kg |
| Gross Weight | 3.0 kg |
| Warranty | 2-Year Parts Coverage |
| Brand | Deepflow |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CYPR0LSIA1 |
| Pricing | Available Upon Request |
| Brand | Santiyiqi |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | ST-D12SY |
| Heating Method | Water Bath Heating |
| Sample Capacity | 12-position |
| Construction Material | Stainless Steel (304) |
| Temperature Control | PID Digital Controller with Dual LED Display, Timer Function, Over-Temperature Alarm & Dry-Run Protection |
| Gas Flow Control | Individual Adjustable Needle Valve per Channel |
| Sample Holder | Spring-Loaded Tube Clamps with Numbered Positions & Height-Adjustable Support Plate |
| Structural Design | Rotatable Circular Base for Easy Access to Water Bath |
| Safety Compliance | Compatible with Fume Hood Operation for Toxic Solvent Concentration |
| Gas Compatibility | Optimized for High-Purity Nitrogen (N₂) Delivery |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | Arium Mini |
| Water Grade | Type I (ASTM D1193-20) |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | <1 ppt |
| Total Organic Carbon (TOC) | ≤5 ppb |
| Microbial Count | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Daily Output Capacity | Up to 10 L |
| Footprint Width | 28 cm (37 cm with optional mobile dispensing unit) |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | arium® 611 DI |
| Dimensions (W×H×D) | 30.2 × 11.3 × 15.7 cm |
| Operating Weight | 23.6 kg |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Total Organic Carbon (TOC) | <4 ppb |
| Particulates | <1 particle/mL @ ≥0.2 µm |
| Microbial Content | <1 CFU/mL |
| Flow Rate | 1.7 L/min |
| Application Suitability | AA, IC, ICP, ICP-MS, HPLC |