Empowering Scientific Discovery

Qingdao Lubo Jianye Environmental Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
Brand2B Technologies
OriginUSA
Model106L
Instrument TypePortable
Measurement Range0–100 ppm
Limit of Detection (LOD)0.1 ppb (v/v)
Response Time (T90)10 s
Zero Drift≤10 ppb/24 h
Resolution10 ppb
ComplianceCE, RoHS, FCC Part 15 Class B
Added to wishlistRemoved from wishlist 0
Add to compare
Brand2B Technologies
OriginUSA
Model202
Instrument TypePortable
Measurement Range0–250 ppm (0–250,000 ppb)
Detection Limit3.0 ppb (10-sec mode)
Resolution0.1 ppb
Accuracy±1.5 ppb or ±2% of reading
Precision±1.5 ppb or ±2% of reading
Response Time (100% step)20 sec
Zero Drift<2 ppb/day, <5 ppb/year
Sensitivity Drift<1%/day, <3%/year
Flow Rate~1.0 L/min (min. 0.6 L/min)
Data Logging Capacity16,383 rows internal
Operating Temperature0–50 °C standard
Operating Altitude0–13.5 km (standard)
Power11–14 V DC / 120–240 V AC, 600 mA, 7.2 W
Dimensions9 × 21 × 29 cm
Weight2.5 kg (instrument only)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalox
OriginUnited Kingdom
ModelAspida
Instrument TypePortable
Detection TargetSingle-Gas (CO₂)
Measurement Range0.01–5% vol CO₂
Repeatability±2% FS (0.01–2.5% vol), ±3% FS (2.5–5% vol)
Resolution0.01% vol
Response Time (T90)20 s
Zero Drift≤±5% FS
Span Drift≤±1% FS
Linearity Error≤±2% FS
Operating Temperature−5 to +50 °C
IP RatingIP65
EMC Compliance2004/108/EC
Battery Life12 h (fully charged or with two AA batteries)
Audible Alarm95 dB @ 30 cm
Man-Down / Emergency Alarm110 dB @ 30 cm
Visual IndicatorsGreen (OK), Yellow (Fault), Triple Red (Alarm)
Alarm ConfigurationThree user-set CO₂ concentration thresholds + one TWA alarm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAFRISO
OriginGermany
ModelBL100
Instrument TypePortable Flue Gas Analyzer
Measured GasesO₂, CO
O₂ Range0–21.0 vol.%
CO Range0–20,000 ppm
O₂ Accuracy±0.2 vol.% of reading
CO Accuracy±5 ppm (≤100 ppm), ±5% of reading (100–2000 ppm)
Repeatability±2%
Response Time (T90)<3 s (temperature), <30 s (CO), <20 s (O₂)
Stability±2% over 8 h
Display2.8" TFT color screen
Data Storage4 GB micro-SD/HC card
BatteryLi-ion, 3.6 V / 1800 mAh, up to 10 h operation
Dimensions (H×W×D)215 × 70 × 40 mm
Weight~500 g (incl. magnetic protective case)
IP RatingIP42 (EN 60529)
Operating Temperature−5 to +40 °C
Storage Temperature−20 to +50 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandActive Spectrum
OriginUSA
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelWATCHDOG 2475
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandActive Spectrum
OriginUSA
ModelWATCHDOG 2400
IP RatingIP66
Power Supply4×AA batteries (alkaline: up to 10 months
lithiumup to 12 months)
Data StorageNon-volatile memory with auto-failover protection
DisplayIntegrated LCD for real-time and daily min/max values
Sensor CapacityUp to 4 internal soil moisture/temperature probes + up to 9 external sensors
CommunicationRS-232 serial port
ComplianceCE, FCC Class B, RoHS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandActive Spectrum
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSM100
Instrument TypePortable
Detection Channels1 or 4 (configurable)
Measured ParameterVolumetric Water Content (VWC)
Maximum Sample Mass Capacity1 kg
Operating Voltage3–5 V DC @ 6–10 mA
Output SignalAnalog voltage (0.5–1.5 V at 3 V excitation
Oscillation Frequency70–80 MHz
Resolution0.1% VWC
Accuracy±1–3% VWC (for soil EC < 8 mS/cm)
Sensing Volume6 cm × 2 cm × 0.3 cm
Standard Cable Length1.8 m (optional: 6 m
Handheld Meter Operating Temperature−40 °C to +50 °C
Data Storage≥6 months continuous logging
Measurement Time≤1 s per reading
Interface2.5 mm stereo jack (3-conductor)
Data TransferUSB cable
Enclosure RatingIPX4 (splash-resistant)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNew Cosmos
OriginJapan
ModelXP-3310II
Instrument TypePortable
Detection PrincipleCatalytic Bead (Pellistor)
Measurement Range0–100% LEL
Accuracy±5% FS
Resolution0.1% LEL
Alarm Threshold20% LEL
Sampling MethodBuilt-in Pump (Active Draw)
Enclosure RatingIP67
Explosion ProtectionEx ia da IIC T4 Ga (Alkaline Battery) / Ex ia da IIC T3 Ga (Ni-MH Battery)
Operating Temperature−20 to +50 °C
Operating Humidity0–95% RH (non-condensing)
Power Supply4 × AA Alkaline or Ni-MH Rechargeable Batteries
WeightApprox. 460 g (with batteries)
Dimensions91 × 164 × 44 mm (W × H × D)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLoobo
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelLB-8101
Rain Sensor Sensitivity≥0.03 mm/min
Lid Opening Time≤30 s
Lid Closing Time≤5 min
Measurable Rainfall Intensity Range0.03–4 mm/min
Measurement Accuracy±1%
Precipitation Collector Diameter300 mm
Dust Deposition Cylinder Height150 mm
Sampling Bucket Capacity15 L
Operating Temperature0–50 °C
Operating Relative Humidity≤98% RH
Dimensions (L×W×H)1200 × 550 × 1000 mm
Weight~40 kg
Power SupplyAC 220 V ±10%, 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUK
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelASP-BB02-Y1101
Instrument TypePortable
Detection TargetSingle Gas (CO₂)
Range0–5 %vol (0–50,000 ppm)
Resolution0.01 %vol
Repeatability±1 % of reading
Zero Drift±1 % FS/month
Span Drift±2 % FS/month
Linearity Error±2 % FS
Response Time (T90)<60 s
Operating Temperature−5 to +50 °C
IP RatingIP65
EMC Compliance2004/108/EC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLoobo
OriginShandong, China
ModelONG300
TypeHandheld
PrinciplePulsed Time-of-Flight Laser Ranging
Measurement Range0–600 m
Accuracy±0.3 m
Magnification
Objective Lens Diameter25 mm
Eyepiece Lens Diameter16 mm
Weight~195 g (with batteries)
IP RatingIP54
Operating Temperature0–40 °C
Laser Safety ClassIEC 60825-1 Class 1
Measurement ModesDistance, Height, Angle, Speed
Angular Range±90°
Angular Accuracy<0.3°
Speed Measurement Error±5 km/h
Target Requirements≥2 m × 2 m surface area, near-perpendicular incidence, medium reflectivity (e.g., concrete wall), clear atmospheric conditions
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLoobo
OriginShandong, China
ModelLB-8000B
Instrument TypePortable Automatic Water Sampler
Sampling MethodQuantitative Sampling
Single Sample Volume200–1000 mL (adjustable)
Sampling Volume Accuracy±1%
Pump Speed Range60–300 rpm (bidirectional)
Minimum Sampling Interval1 minute
Maximum Sampling Depth10 m
Power SupplyAC 220 V ±10%, 50/60 Hz (standard)
Power Consumption<22 W
Operating Temperature0–40 °C
Relative Humidity<80% RH
Drive Unit Dimensions234 × 144 × 140 mm
Drive Unit Weight3 kg
Enclosure RatingIP31
Display3-digit LED (real-time speed)
Control InterfaceRotary pulse encoder
Memory FunctionPower-loss data retention
Motor TypeHybrid stepper motor
Pump MechanismHigh-reliability peristaltic pump
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLoobo
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelKS2202
PriceUSD 2,800 (FOB Qingdao)
Measurement PrinciplePotassium Permanganate Oxidation with ORP Endpoint Detection
Instrument TypeOnline Continuous Analyzer
Range10–5000 mg/L COD<sub>Cr</sub>
Repeatability≤3% RSD
Accuracy±5% of reading (≥100 mg/L)
LOD15 mg/L
Resolution1 mg/L
Cycle Time15 min per analysis
ComplianceHJ 377–2019, GB 11914–1989
Auto-Standard VerificationYes
Dual Waste DischargeCleaning Solution & Spent Reagent Separately Collected
Chloride ToleranceUp to 35,000 mg/L Cl⁻ (with HgSO₄ masking)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLoobo
OriginShandong, China
ModelLB-7220
Instrument TypeOnline Continuous Monitor
Measurement PrincipleBeta-Ray Absorption
Measured ParametersPM₂.₅, PM₁₀, TSP
Measurement RangePM₂.₅: 1–1000 µg/m³
PM₁₀1–10,000 µg/m³
TSP0–10 mg/m³
Sampling Flow Rate16.7 L/min
Detection Limit1 µg/m³
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLoobo
ModelLB-TR008
MaterialAISI 304 Stainless Steel
Sampling Depths1 m, 1.5 m, 2 m
Sample Length per Insertion15–20 cm
Depth ScaleMarked at 100 mm intervals
Weight5 kg
ConfigurationModular threaded assembly (bit, extension tube, handle)
ApplicationField-based manual soil core sampling
ComplianceDesigned for ISO 10381-1 (soil sampling principles), ASTM D1586 (standard penetration test reference geometry), and GLP-aligned sample integrity protocols
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0