Empowering Scientific Discovery

Qingdao Zhongrui Intelligent Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunray
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelZR-1630 (28.3 L/min)
Instrument TypeHandheld
Flow Rate28.3 L/min
Flow Accuracy≤ ±2%
Repeatability≤ 10% FS
Particle Size Distribution Error≤ ±30%
Indication Error±30% FS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunray
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelZR-1002
Instrument CategoryAerosol Testing System
Compliance StandardsGB/T 6165–2008, GB 2626–2006, GB/T 32610–2016
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunray
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelZR-1012
Instrument TypeAutomated Biological Safety Cabinet Challenge Tester
Detection Throughput10 simultaneous sampling points
Filter Cup CapacityStandard microbiological filter holders (not applicable for filtration volume)
Filter Membrane Diameter50 mm (standard for impactor/slit samplers)
Aerosol Generation RateUp to 200 L/min (calibrated with PAO or Bacillus atrophaeus spore aerosol)
ComplianceYY 0569–2011, GB/T 16292–2010, ISO 14644-1 Class 5 equivalent containment verification
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunray
OriginShandong, China
Manufacturer TypeOEM Manufacturer
Country of OriginDomestic (China)
ModelZR-3230 TDLAS Ammonia Analyzer
Measurement RangeConfigurable (ppm)
Accuracy±0.01 ppm
Response Time≤30 s
RepeatabilityHigh (with heated sample path)
Operating Ambient Temperature−20 to 45 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunray
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelZR-3110C
Detection TargetVOCs (Volatile Organic Compounds)
Sensor TechnologiesElectrochemical (EC), Catalytic Bead (LEL), Photoionization Detection (PID)
Compliance StandardsGB 12358–2006, HJ 872–2017, GBZ 2.1–2019, GB/T 36198–2018, JJF 1172–2007, JJG 915–2008, JJG 635–2011, JJG 551–2003, JJG 695–2003, JJG 693–2011, Q/0214 ZRB008–2017
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunray
OriginShandong, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelZR-3260E
Instrument TypeFlue Gas and Particulate Sampler
Measured GasesSO₂, NO, NO₂, NOₓ, CO, CO₂, H₂S, O₂
Sampling Flow RateNot specified
Flow AccuracyNot specified
Flue Gas VelocityNot specified
Moisture Content MeasurementNot specified
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunray
ModelZR-B01
TypeAGI-30 Impinger
OriginShandong, China
ManufacturerJunray Instrument Co., Ltd.
ComplianceGB/T 18204.1–2013, HJ 93–2013, ISO 14698-1:2003 (principles)
Liquid Volume Capacity15–30 mL
Inlet Flow Rate Range5–15 L/min (optimized at 12.5 L/min)
Nozzle Orifice Diameter0.5 mm
MaterialBorosilicate Glass (USP Type I), PTFE-sealed cap
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunray
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelZR-1304
Airflow Range0–120 L/min
Aerosol Concentration Range0–200 µg/L
Generation MethodCold Aerosol Generation
Compatible MediaLiquid Paraffin, DOP (Di-Octyl Phthalate), and other oil-based test fluids
Particle Size OutputSub-micrometer to micrometer range
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunray
OriginShandong, China
Manufacturer TypeDirect Manufacturer
ModelZR-3703
Sampling Flow Rate0.1–1.0 L/min
Flow Accuracy±2.0%
Operating Temperature Range−20 to 50 °C
Sample TypesElemental Mercury (Hg⁰) and Oxidized Mercury (Hg²⁺)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunray
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelZR-6012
Instrument TypeAerosol Photometer
Detection PrincipleMie Scattering
Concentration Range0.0001–700 μg/L
ComplianceJJF 1800–2020, ISO 14644-3:2005, GB 50073–2013, GB 50591–2010, YY 0569–2005, JJF 1815–2020, NSF/ANSI 49–2019