Radiation Detector
Filter
Showing 1–30 of 70 results
| Brand | Ailun |
|---|---|
| Model | AL-200 |
| Type | Portable Activity Meter (Radionuclide Concentration Analyzer) |
| Detector | Scintillation Crystal (NaI:Tl) |
| Power Supply | AC 100–240 V (with adapter) or 2×AA batteries |
| Display | Backlit LCD with real-time activity readout (Bq/kg or Bq/L) |
| Data Storage | Up to 200 measurement records |
| Radiation Indication | Tri-color LED status indicator (green/yellow/red) |
| Sample Forms | Liquids (water, beverages) and solids (food, soil, filters) |
| Shielding | Integrated lead-lined metal housing |
| Connectivity | Optional USB interface for PC-based control and data export |
| Compliance | Designed per IEC 60846-1:2014 (radiation protection instrumentation – ambient and/or directional dose equivalent rate meters) |
| Weight | <1.8 kg |
| Dimensions | 220 × 110 × 75 mm |
| Brand | Ailun (Qingdao Ailun) |
|---|---|
| Origin | Shandong, China |
| Model | AL-FS6100 |
| Instrument Type | Laboratory-Based Activity Meter |
| Channel Configurations | 2 / 4 / 6 / 8 Independent Channels |
| Compliance | GB 5749–2006, GB/T 5750.13–2006, GB 8537–2008, HJ 898–2017, HJ 899–2017 |
| Control Interface | USB 2.0 (Driver-Free), Windows-Compatible Multi-Document Application |
| Detector Type | Planar Passivated Implanted Planar Silicon (PIPS) with Enhanced Geometry |
| High-Voltage Supply | Low-Ripple Linear DC HV Regulator (<10 µA Static Current) |
| Display | 320×240 TFT Color LCD on Controller Unit |
| Enclosure | 19″ Rack-Mountable Shielded Cabinet with Interlocked Lead-Lined Access Door |
| Core Electronics | CPLD-Based Digital Pulse Processing Architecture |
| PCB Design | Multi-Layer High-Density Layout for EMI Suppression and Signal Integrity |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | 31-040A |
| Price | Upon Request |
| Detection Radiation | X-ray & Gamma (γ) |
| Dose Rate Range | 0.01 µSv/h – 10 mSv/h |
| Cumulative Dose Range | 0.1 pSv – 1 Sv |
| Energy Response Range | 30 keV – 3 MeV |
| Dose Rate Accuracy | ±30% (typical, per IEC 61526 ed.3) |
| Operating Temperature | −20 °C to +50 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Power Input | DC 5 V / 200 mA |
| Ingress Protection | IP65 |
| Battery Life | >72 h (background radiation environment, no external power) |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | ChiRad 160C |
| Price | Upon Request |
| X-ray Energy Range | 40–160 kV |
| Tube Current | 10 mA |
| System Power | 800 W (configurable) |
| Focal Spot Size | 1.2 mm |
| Beam Coverage Diameter | 40 cm |
| Source-to-Object Distance | 13–55 cm |
| Exposure Time | 1–180 min |
| Input Power | 220 VAC ±10%, 50/60 Hz, Single-phase, 9 kVA |
| Cooling | Integrated Closed-loop Heat Exchanger |
| Sample Turntable | Motorized, 2 RPM |
| Internal Chamber Dimensions | 335 × 375 × 395 mm (W×D×H) |
| External Dimensions | 730 × 560 × 1300 mm (W×D×H) |
| Weight | 660 kg |
| Leakage Dose | <0.5 µSv/hr at 10 cm from surface (max energy operation) |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | ChiRad 4000 |
| Price | Upon Request |
| Maximum Tube Voltage | 75 kV (adjustable) |
| Focal Spot Size | 7.5 mm |
| Max Tube Current | 50 mA (adjustable) |
| System Power | 4000 W (adjustable) |
| Radiation Cone Angle | 40° |
| Max Irradiation Field Diameter (on Rotating Platform) | 30 cm |
| Source-to-Sample Distance (SSD) | 5–50 cm (adjustable) |
| Single Exposure Duration | 1–60,000 s (adjustable) |
| Dose Rate | Up to 600 Gy/min |
| Irradiation Chamber Dimensions (W×H×D) | 45 × 50 × 40 cm |
| Overall Enclosure Dimensions (H×W×D) | ~182 × 110 × 88 cm |
| Cooling System | Industrial Air-Cooling + Compressor-Based Water Chiller |
| Shielding | Lead-lined Enclosure |
| Uniformity | ≥95% (with Motorized Turntable & Beam Filtration) |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | ChiRad225 Pro |
| Pricing | Upon Request |
| Maximum Tube Voltage | 225 kV |
| Tube Current | 20 mA |
| System Power | 4.5 kW |
| Focal Spot Size (EN) | 5.5 mm |
| Inherent Filtration | 2 mm Be |
| Radiation Beam Angle | 40° |
| Effective Irradiation Field Diameter | 40–50 cm |
| Source-to-Object Distance Range | 13–80 cm |
| Exposure Time Range | 1 s to 9999 h |
| Input Power | 220 VAC ±10%, 50/60 Hz, Single-phase, 9 kVA |
| Cooling System | Integrated Closed-loop Heat Exchanger |
| Sample Stage | Motorized Vertical Lift & Rotation (2 RPM) |
| Internal Chamber Dimensions | 75 cm (H) × 55 cm (W) × 55 cm (D) |
| Leakage Dose | <0.5 µSv/h at 10 cm from surface (at max output) |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | ASM IV Series |
| Instrument Type | Portable Dose Rate Meter |
| Measurement Target | Nuclear Radiation |
| Detector Type | Plastic Scintillator |
| Application Scope | Radiological Contamination Incidents |
| Sensitivity | High |
| Brand | AST / ST |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | PRC |
| Model | DM5200 |
| Instrument Type | Radiation Dose Rate Meter |
| Measurement Range | 0.01–200 µSv/h |
| Energy Response | 0.048–3.00 MeV (≤±20% relative to ¹³⁷Cs) |
| Basic Relative Error | ≤±10% |
| Repeatability | ≤5% RSD per single measurement |
| Accuracy (95% confidence, 15 s integration) | ≤±10% |
| Alarm Thresholds | 0.25, 2.5, 10, 20 µSv/h (user-selectable) |
| Integration Time | 1–60 s (adjustable in 1 s increments) |
| Operating Temperature | −10 °C to +40 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Power Supply | Two 1.5 V D-cell batteries |
| Power Consumption | ≤150 mW |
| Dimensions | 330 × 230 × 90 mm |
| Weight | 1.5 kg |
| Detector | NaI(Tl) scintillation crystal |
| Display | Dot-matrix LCD with Chinese UI |
| Interface | Touch-sensitive keypad |
| Units | µSv/h (default), selectable µR/h |
| Battery Monitoring | Real-time voltage monitoring with low-battery alert |
| Brand | ATOMTEX |
|---|---|
| Model | AT1103M |
| Type | Portable Dose Rate Meter |
| Detector | Be-window NaI(Tl) Scintillator (Ø9×2 mm) |
| Measured Quantity | Ambient Dose Equivalent Rate H′(0.07) |
| Measurement Range | 50 nSv/h – 100 µSv/h |
| Energy Range | 5–160 keV |
| Energy Response | ±35% (5–60 keV), ±30% (60–160 keV) |
| Accuracy | ±15% (full range), ±5% (calibration sources: ⁵⁵Fe, ²⁴¹Am, ¹⁰⁹Cd, ⁵⁷Co) |
| Operating Temperature | 0–+40 °C |
| Relative Humidity | ≤90% at +35 °C |
| IP Rating | IP54 |
| Weight | 0.8 kg |
| Dimensions | 233×85×67 mm |
| Power | Rechargeable Ni-MH battery (6 V), AC 220 V / 50 Hz, DC 12 V |
| Battery Life | ≥24 h |
| Data Storage | 100 measurement records + 256-channel MCA spectrum storage |
| Compliance | IEC 60846, CISPR 22:1997, IEC 61000-4-2:1995, IEC 61000-4-3:1995 |
| Brand | ATOMTEX |
|---|---|
| Origin | Belarus |
| Model | AT1121 |
| Detection Principle | Scintillation (plastic scintillator with heavy metal admixture) |
| Measuring Quantity | Ambient Dose Equivalent H*(10) |
| Continuous Dose Rate Range | 50 nSv/h – 10 Sv/h |
| Short-Term Dose Rate Range | 5 µSv/h – 10 Sv/h |
| Pulse Dose Rate Capability | Down to 10 ns (for AT1123 variant |
| Energy Range | 15 keV – 10 MeV |
| β Detection | Yes (with optional collimator/filter cap) |
| Display | Backlit LCD |
| Data Storage | 100 measurements |
| Interface | RS-232, 300–19200 baud |
| Operating Temperature | −30 °C to +40 °C |
| IP Rating | IP54 |
| Weight | 0.9 kg |
| Dimensions | 233 × 85 × 67 mm |
| Power | Rechargeable 6 V battery / AC 220 V / DC 12 V |
| Compliance | IEC 61000-4-2:1995, IEC 61000-4-3:1995, CISPR 22:1997 |
| Brand | ATOMTEX |
|---|---|
| Origin | Belarus |
| Model | AT1121 |
| Detection Principle | Scintillation (Plastic Scintillator with Heavy Metal Mixture, 30 × 15 mm) |
| Measured Quantity | Ambient Dose Equivalent H*(10) |
| Continuous Dose Rate Range | 50 nSv/h – 10 Sv/h |
| Short-Term Dose Rate Range | 5 µSv/h – 10 Sv/h |
| Pulse Dose Rate Capability | Down to 10 ns (for AT1123/AT1123A variants only) |
| Energy Range | 15 keV – 10 MeV |
| β Detection Capability | Yes |
| Operating Temperature | −30 °C to +40 °C |
| IP Rating | IP54 |
| Weight | 0.9 kg |
| Dimensions | 233 × 85 × 67 mm |
| Power Supply | Rechargeable 6 V battery (≥12 h), AC 220 V, or DC 12 V |
| Data Interface | RS-232, 300–19200 baud |
| Memory Capacity | 100 measurement records |
| Display | Backlit LCD |
| Alarm | Audible and visual threshold alerts |
| Brand | Atomtex |
|---|---|
| Model | AT1320 |
| Detector Type | Scintillation-based Gamma Spectrometer |
| Detector Crystal | NaI(Tl), Ø63×63 mm |
| Activity Range (¹³⁷Cs) | 3.7–1,000,000 Bq/kg (or Bq/L) |
| Activity Range (⁴⁰K) | 50–20,000 Bq/kg |
| Activity Range (²²⁶Ra & ²³²Th) | 10–10,000 Bq/kg |
| Energy Range | 50–3000 keV |
| Energy Resolution (¹³⁷Cs, 662 keV) | 7.0–8.5 % FWHM |
| Intrinsic Nonlinearity | ≤1 % |
| Relative Uncertainty in Specific Activity Measurement | ≤±20 % |
| Minimum Detectable Activity (¹³⁷Cs in 1 L Marinelli beaker, 3 h, P=0.95) | 3.0 Bq/L |
| Sample Density Range | 0.1–3.0 g/cm³ |
| Operating Temperature | 0–40 °C |
| Power Supply | 220 V ±10 %, 50 Hz ±2 Hz |
| Power Consumption | ≤8 VA |
| Continuous Operation Time | ≤24 h |
| 24-h Drift | ≤3 % |
| Dimensions (Detector) | 97×405 mm, 3.0 kg |
| Dimensions (Processing Unit) | 200×109×35 mm, 0.62 kg |
| Shielding Assembly | Ø600×700 mm, 110 kg |
| AC Adapter | 92×62×52 mm, 0.8 kg |
| EMC Compliance | IEC/EN 61000-4-2:1995, IEC/EN 61000-4-3:1995, IEC/EN 61000-4-4:1995, IEC/EN 61000-4-11:1994, CISPR 22:1997 |
| Brand | Atomtex |
|---|---|
| Model | AT2140 / AT2140A |
| Type | Personal Dose Rate & Dose Meter (γ-ray) |
| Dose Rate Range (AT2140) | 0.01 μSv/h – 10 mSv/h |
| Dose Rate Range (AT2140A) | 0.01 μSv/h – 100 mSv/h |
| Dose Range | 0.01 μSv – 9.99 Sv |
| Dose Measurement Range | 0.1 μSv – 1.99 Sv |
| Relative Measurement Error | ±15% max. |
| Calibration Accuracy | ±5% max. |
| Sensitivity to ¹³⁷Cs | 1.8 cps/(μSv·h⁻¹) |
| Energy Response Range | 50 keV – 3 MeV |
| Energy Dependence (vs. 662 keV ¹³⁷Cs) | ±30% (AT2140), ±25% (AT2140A) |
| Angular Dependence (±60°, ¹³⁷Cs/⁶⁰Co) | ±25% |
| (²⁴¹Am) | ±60% |
| Response Time (Dose Rate >1 � | Sv/h): ≤10 s (AT2140), ≤5 s (AT2140A) |
| Operating Temperature | −20°C to +50°C (AT2140), −30°C to +60°C (AT2140A) |
| Relative Humidity (non-condensing) | ≤95% at 35°C |
| IP Rating | IP40 |
| Drop Resistance | 1.0 m onto hard surface |
| Power Supply | 2 × AA batteries |
| Battery Life | 5,000 h (AT2140), 10,000 h (AT2140A) |
| Dimensions & Weight | 111 × 70 × 28 mm, 0.11 kg |
| Brand | ATOMTEX |
|---|---|
| Origin | Imported (Non-China) |
| Manufacturer Type | Authorized Distributor |
| Model | AT2503 |
| Measurement Range (Hp(10)) | 1 µSv – 10 Sv |
| Dose Rate Range (Hp(10)) | 0.1 µSv/h – 0.5 Sv/h |
| Energy Response | 50 keV – 1.5 MeV |
| Dose Accuracy (¹³⁷Cs) | ±5% |
| Dose Rate Accuracy | ±25% (0.1–1 µSv/h), ±15% (>1 µSv/h) |
| Energy Dependence | ±30% |
| Alarm Thresholds | 8 programmable independent levels |
| Detector Type | Energy-compensated GM tube with built-in background tracking |
| Communication | IR interface to reader, RS-232 to PC |
| Calibration | Traceable to water-equivalent phantom (30 × 30 × 15 cm) |
| Brand | AUTOMESS |
|---|---|
| Origin | Germany |
| Model | 6150AD-6 |
| Type | Portable Dose Rate Meter |
| Measurement Principle | Ionization Chamber / GM Tube Based Photon Detection (γ/X-ray) |
| Energy Range | 60 keV – 1.3 MeV |
| Dose Rate Range (Digital) | 0.01 µSv/h – 9.99 mSv/h |
| Dose Rate Range (Analog) | 0.1 µSv/h – 10 mSv/h |
| Alarm Functions | Adjustable Dose & Dose Rate Thresholds |
| Interface | RS232 Serial Port |
| External Probe Support | Up to 100 m cable length (model-dependent) |
| Certification | PTB Certified (Physikalisch-Technische Bundesanstalt, Germany) |
| Power Supply | IEC 6LR61 9 V battery |
| Compliance | Designed for IEC 60846, IEC 61017, and ISO 4037-3 referenced radiation protection applications |
| Brand | Automess |
|---|---|
| Origin | Germany |
| Model | 6150AD-6 |
| Type | Portable Dose Rate Meter |
| Measurement Principle | Ionization Chamber / GM Tube Based Photon Detection (γ/X-ray) |
| Energy Range | 60 keV – 1.3 MeV |
| Dose Rate Range (Digital) | 0.01 µSv/h – 9.99 mSv/h |
| Dose Rate Range (Analog) | 0.1 µSv/h – 10 mSv/h |
| Power Supply | IEC 6LR61 (9 V) Battery |
| Interface | RS232 Serial Port |
| External Probe Cable Length Options | 1.25 m, 3 m, 10 m, 20 m, 75 m, 100 m |
| Compliance | PTB Certified (Physikalisch-Technische Bundesanstalt, Germany) |
| Brand | Capintec |
|---|---|
| Origin | USA |
| Model | CRC55tR |
| Instrument Type | Portable Dose Calibrator |
| Measurement Principle | Ionization Chamber (Thin-Walled, High-Pressure Argon-Filled Well Chamber) |
| Max Activity Range | 250 GBq (6 Ci) |
| Minimum Detectable Activity | 0.001 MBq (0.01 µCi) |
| Display | 8" VGA Color Touchscreen |
| Accuracy | ±2% |
| Linearity | ±2% |
| Response Time | ≤2 s (standard), 4–16 s (low-activity samples) |
| Chamber Fill Gas | Ultra-High-Purity Argon at 12 atm |
| Well Dimensions | Ø6.1 cm × Depth 25.4 cm |
| Console Dimensions | 42 × 23 × 27 cm |
| Console Weight | 3.4 kg |
| Chamber Weight | 13.6 kg |
| Power | 100–240 VAC, 50/60 Hz, 90 mA |
| Interfaces | RS-232, USB |
| Compliance | Meets NIST-traceable calibration requirements for nuclear medicine |
| Brand | Fangyuan Scientific Instruments |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | FY3104-00 |
| Instrument Type | Laboratory Alpha Spectrometer |
| Measurement Medium | Solid Samples |
| Detector Interface | Compatible with Commercial PIPS Detectors (International & Domestic) |
| Radiation Type | Alpha Particles |
| Sensitivity | 0.01 cpm (counts per minute) in 3–10 MeV range |
| Energy Range | 3–10 MeV |
| Background Count Rate | <1 count/hour (3–10 MeV) |
| Energy Resolution | FWHM ≤18 keV at 5.486 MeV (with 300 mm² PIPS detector, source-to-detector distance = detector diameter) |
| Multichannel Scaling | 512 / 1024 / 2048 / 4096 channels (software-selectable) |
| Bias Voltage | 0–180 V (digital, 0.2 V resolution) |
| Leakage Current Monitoring | –3 to +150 nA (accuracy <1 nA) |
| Vacuum Control | Adjustable vacuum hold, pump-down, and vent modes |
| Sample Chamber | Recoil suppression design |
| Sample Stage | Manually adjustable vertical positioning (4 mm resolution) |
| Detector Active Area | 300–1200 mm² |
| Operating Temperature | 0–40 °C |
| Relative Humidity | 10–80 % RH |
| Communication Interfaces | USB, RS-232, Ethernet, Wi-Fi |
| Software | AlphaSense — spectral acquisition, energy/efficiency calibration, nuclide library (built-in + user-defined), peak deconvolution, and GLP-compliant data logging |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | FHT 762 |
| Price Range | USD 13,500–27,000 (FOB) |
| Instrument Class | Dose Rate Meter |
| Form Factor | Portable |
| Measured Radiation | Neutrons |
| Detector Type | Wide-Energy Neutron Detector |
| Dose Equivalent Range | 1 mSv/h – 10 Sv/h |
| Sensitivity | 0.84 cps per µSv/h (calibrated to ²⁵²Cf) |
| Gamma Rejection Ratio | < 5 µSv/h equivalent dose error at 100 mSv/h ¹³⁷Cs |
| Angular Dependence | ±20% over 4π geometry |
| Energy Response Range | 0.025 eV – 5 GeV (ICRP Publication 74, 1996) |
| Brand | GEORADIS |
|---|---|
| Origin | Czech Republic |
| Model | RT-50 A |
| Instrument Type | Laboratory Gamma Spectrometer |
| Detector Type | NaI(Tl) Scintillation Crystal (76 mm × 76 mm, 0.35 L) |
| Measurement Range | 20 keV – 3.0 MeV |
| Energy Resolution | ≤7.5% FWHM at 662 keV (¹³⁷Cs) |
| Sensitivity | 0.02 Bq/g (for ⁶⁰Co) |
| Channel Count | 1024-channel MCA |
| Shielding | ≥9 cm lead equivalent (min. wall thickness 3.5 in), integrated sliding heavy-duty shielded lid |
| Dimensions (H×W×D) | 770 × 360 × 620 mm |
| Weight | 410 kg (lead-shielded configuration: 580 kg) |
| Interface | USB 2.0 |
| Operating Temperature | 0–40 °C |
| Software Platform | LabCentre (Windows/Linux, FirebirdSQL 2.6+) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HD-2000 |
| Price | USD 1,240 (FOB) |
| Measurement Range | 0.01–100 µGy/h |
| Energy Threshold | 60 keV |
| Linearity (r vs. CPS) | ≥0.999 |
| Stability | ≤6% |
| Accuracy | ±20% |
| Sensitivity | ≥350 cps at 1 µGy/h |
| Power Consumption | ≤100 mW |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤90% @ 40 °C |
| Weight | 6 kg |
| Dimensions | 35 × 20 × 25 cm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DIgialert-100 |
| Pricing | Upon Request |
| Display | LCD digital display with red LED alarm indicator |
| Operating Temperature Range | –10 °C to +50 °C |
| Detector Type | M-type GM tube with integrated beryllium-window (ICA) for alpha/beta/gamma detection |
| Sensitivity | 1000 CPM per mR/hr (calibrated with Cs-137) |
| Accuracy | ±10% typical |
| Dose Rate Range | 0.001–50 mR/hr |
| Count Rate Range | 0–50,000 CPM |
| Accumulated Count Range | 0–9,999,000 counts |
| Radiation Types Detected | Alpha (α), Beta (β), Gamma (γ), and X-rays |
| Audio Output | Audible alarm via 3.5 mm headphone jack |
| Power Supply | One 9 V alkaline battery (IEC 6LR61) |
| Battery Life | Up to 2000 hours (typical continuous operation) |
| Weight | 0.5 kg |
| Probe Integration | Integrated collimated GM detector assembly |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | ML-91 |
| Price | USD 950 (FOB Jiangsu) |
| Operating Temperature | −10 °C to +40 °C |
| Relative Humidity | 66 % ±15 % RH |
| Atmospheric Pressure | 750 mmHg ±30 mmHg |
| Frequency Band | 3–33 cm (i.e., 0.9–10 GHz) |
| Power Density Range | 0.2 µW/cm² to 20 mW/cm² |
| Display | 3-digit LED, auto-ranging across 200 µW/cm² / 2 mW/cm² / 20 mW/cm² scales with LED range indicators |
| Alarm Threshold | Adjustable, default ≥5 mW/cm² |
| Calibration Field Accuracy | ±0.75 dB |
| Full-Scale Indication Error (at rated voltage) | ≤±1.5 % |
| Indicator Dimensions | 82 mm × 40 mm × 172 mm |
| Net Weight | 0.8 kg |
| Brand | ORTEC |
|---|---|
| Origin | USA |
| Model | DSPEC-50 |
| Interface | USB 2.0 & Ethernet (TCP/IP) |
| Display | Integrated large LCD panel |
| Detector Compatibility | HPGe, Si(Li), NaI(Tl), and other pulse-mode radiation detectors |
| Dead Time Correction | Advanced real-time algorithm |
| LFR (Low-Frequency Noise Rejection) | Enabled |
| Count Rate Capability | Up to 30% higher throughput at ultra-high count rates |
| Resolution Enhancement | Mitigates EC-induced resolution degradation |
| Form Factor | Benchtop digital multichannel analyzer (MCA) |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Power Plant Seawater Radiation Environmental Monitoring System |
| Pricing | Upon Request |
| Instrument Class | Dose Rate Meter / Activity Monitor |
| Instrument Type | Online Continuous Monitoring System |
| Measured Medium | Liquid (Seawater) |
| Brand | Radcal (USA) |
|---|---|
| Origin | USA |
| Model | Rapid-Gold+ Touch Pro |
| Dimensions | 114 × 92 × 158 mm |
| Weight | 700 g |
| Display | 5″ capacitive TFT LCD (800×480) |
| Battery | 5.5 Ah Li-polymer, >8 h operation |
| Connectivity | USB 2.0 (Micro-B), Wi-Fi 802.11b/g/n (2.4 GHz, WPA2) |
| Storage | 16 GB internal flash (>100,000 exposures) |
| Compliance | IEC 61674, EN 61326-1:2013 (Group 1, Class B), EN 61000-4-x series |
| Operating Temp | 15–35 °C |
| Humidity | ≤80% RH or ≤20 g/m³ |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Radiation and Contraband Detection System |
| Model | RadEye CD |
| Detector Type | RadEye SX with NaI(Tl) Scintillation Detector |
| Measurement Capability | Simultaneous detection of concealed contraband (e.g., tobacco, explosives, alcohol) and radioactive materials |
| Measurement Range | 5–10 cps (background), 50–100 cps (contraband presence) |
| Sensitivity | ≥5 cps minimum detectable signal above background |
| Analysis Channels | Dual-channel spectral analysis |
| Typical Background Count Rate | 5 cps |
| Effective Measurement Time | 1 second per acquisition |
| Regulatory Compliance | Designed for customs, border security, and port-of-entry applications in accordance with IAEA TS-G-1.2 and ANSI N42.34 standards |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Model | RadEye GR |
| Instrument Type | Portable Dose Rate Meter |
| Detector Type | Sodium Iodide (NaI) Scintillator |
| Wireless Range | 100 m |
| Detector Battery Life | 1300 h |
| Display Unit (RadEye R) Battery Life | 600 h |
| Operating Temperature | –25 °C to +50 °C |
| Compliance | Meets ANSI N42.33, IEC 60846-1:2014, and EU Directive 2013/59/Euratom for portable radiation monitoring devices |
| Brand | -- |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CRM-100 |
| Instrument Type | Portable Dose Rate Meter |
| Measured Radiation Types | Alpha (α), Beta (β), Gamma (γ), and X-ray |
| Detector | Halogen-quenched Geiger-Müller Tube with Mica End-window (1.75″ / 45 mm diameter, density 1.5–2.0 mg/cm²) |
| Wall Material | 0.012″ stainless steel (Grade 446) |
| Energy Range | 20 keV – 3 MeV |
| Dose Rate Range | 0.001–110.0 mR/h or 0.01–1100 µSv/h |
| Count Rate Range | 0–3,500 CPS / 0–350,000 CPM |
| Total Count Capacity | Up to 9,999,000 counts |
| Timer Range | Up to 40 hours |
| Sensitivity | ≥1000 CPM per mR/h (referenced to Cs-137) |
| Accuracy | ±10% typical, ±15% maximum (mR/h and µSv/h modes) |
| Display | 4-digit LCD with mode indicators |
| Audio Feedback | Adjustable click-per-count (muteable) |
| Visual Feedback | LED flash per count |
| Interface | 3.5 mm output jack (CMOS-compatible TTL pulses) |
| Power | One 9 V alkaline battery (typical lifespan: 2160 hours) |
| Dimensions | 150 × 80 × 30 mm |
| Weight | 225 g (including battery) |
| Certifications | CE, RoHS, WEEE, ISO 9001:2001 & ISO 14001 |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | RJ-3 |
| Price | USD 700 (approx.) |
| Instrument Type | Field Strength Meter / Dosimetry Rate Meter |
| Frequency Range | 20–200 MHz |
| Measurement Range | 0–450 V/m (3-range switchable: 0–30 V/m, 30–150 V/m, 50–450 V/m) |
| Overall Measurement Uncertainty | ≤ ±30% |
| Operating Temperature | −10 °C to +40 °C |
| Relative Humidity | ≤ 80% RH |
| Power Supply | Two 6 V F22 alkaline stacked batteries |
| Form Factor | Portable |
| Instrument Dimensions | 170 mm × 100 mm × 45 mm |
| Packaging Dimensions | 450 mm × 370 mm × 150 mm |
| Weight | ~3 kg |