| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HI-2200 |
| Pricing | Upon Request |
| Operating Temperature | −10 °C to 50 °C |
| Host Dimensions | 85 mm × 160 mm × 30 mm |
| Probe Height | 260 mm |
| Weight | 0.6 kg |
| Data Logging Capacity | 65,000 readings |
| Display Units (E-field) | V/m, μW/cm², mW/cm², W/m² |
| Display Units (H-field) | A/m, mA/m, μW/cm², mW/cm², W/m² |
| E100 Probe | Isotropic E-field sensor, 100 kHz–5 GHz, 0.3–800 V/m |
| H200 Probe | Isotropic H-field sensor, 5 MHz–300 MHz, 0.3–10 A/m |
| H210 Probe | Isotropic H-field sensor, 300 kHz–30 MHz, 0.3–30 A/m |
| C300 Probe | E-field % of FCC exposure limits, 100 kHz–8 GHz |
| C310 Probe | E-field % of ICNIRP exposure limits, 100 kHz–8 GHz |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PA-1000 |
| Instrument Type | Gamma Spectrometer |
| Measurement Range | 0.001–9.999 µSv/h |
| Sampling Time | 60 s |
| Accuracy | ±10% |
| Dimensions | 68 × 28 × 121 mm (W×D×H) |
| Weight | 175 g (without batteries) |
| IP Rating | IP40 |
| Origin | UK |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | HSL |
| Instrument Type | Activity Meter (Radiation Intensity Meter) |
| Detector Material | CsI(Tl), 8×8 Array |
| Collimator | Dynamic Coded Aperture |
| Energy Range | 50 keV – 1.5 MeV |
| Field of View | 60° |
| Optical Lens Resolution | 1024 × 768, Auto-Focus |
| Software Interface | Three-Button Operation (Start / Stop / Replay) |
| Weight | <10 kg (with shielding), <6.5 kg (without shielding) |
| Ingress Protection Rating | IP67 |
| Wireless Data Transmission | Yes |
| Brand | Huiyan |
|---|---|
| Origin | Jiangsu, China |
| Model | ML-91 |
| Instrument Type | RF Power Density Meter (Radiation Dosimetry) |
| Frequency Range | 0.9–12.4 GHz |
| Measurement Range | 0.2 µW/cm² to 20 mW/cm² |
| Resolution | 0.2 µW/cm² |
| Display | Digital LCD with Auto-ranging (3 ranges: 200 µW/cm², 2 mW/cm², 20 mW/cm²) |
| Alarm Threshold | Factory-set at 5 mW/cm² (adjustable only by manufacturer) |
| Operating Modes | CW and Pulsed RF |
| Sensor Burnout Limit | 100 mW/cm² (CW), 3 W/cm² peak (pulsed) |
| Calibration Uncertainty | ±0.75 dB |
| Indicating Device Accuracy | ≤ ±1.5% of full scale |
| Dimensions (Indicator Unit) | 82 × 40 × 172 mm |
| Weight (Indicator Unit) | ~0.8 kg |
| Environmental Operating Range | –10 °C to +40 °C, RH 51–81%, Atmospheric Pressure 720–780 mmHg |
| Brand | Hyeyan |
|---|---|
| Model | MHJ-99 |
| Instrument Type | RF Power Density Meter (Metering/Dose Rate) |
| Frequency Range | 0.9–12.4 GHz |
| Measurement Range | 0.2 µW/cm² to 20 mW/cm² |
| Display | LED Digital, 3.5-digit |
| Accuracy (Full Scale) | ±1.5% |
| Calibration Field Uncertainty | ±0.75 dB |
| Operating Modes | Continuous Wave (CW) and Pulsed RF |
| Alarm Threshold | User-Adjustable (Factory Default: 5 mW/cm²) |
| Dimensions | 100 × 210 × 35 mm |
| Weight | ~0.5 kg |
| Environmental Operating Range | −10°C to +40°C, RH 51–81%, Atmospheric Pressure 720–780 mmHg |
| Sensor Sensitivity | Optimized for Wavelengths 3–33 cm |
| Internal Control | Microcontroller-Based Architecture with Auto-Zero and Self-Test Functions |
| Brand | Hyundai |
|---|---|
| Model | MHJ-98A |
| Instrument Type | Microwave Power Density Meter (Continuous & Pulsed Wave) |
| Measurement Principle | Broadband Diode-Detector-Based RF Field Sensing |
| Frequency Range | 0.9–3 GHz |
| Power Density Range | 0.01–9.99 mW/cm² |
| Operating Temperature | −10 °C to +40 °C |
| Calibration Uncertainty | ±0.75 dB |
| Display | LED Digital, 3-digit |
| Analog Output | 0–5 V DC (proportional to measured power density) |
| Digital Switch Output | SPST, rated ≤24 V DC / 1 A |
| Overload Threshold | 100 mW/cm² (CW, non-destructive) |
| Housing | CNC-Machined Aluminum Alloy (EMC-Optimized) |
| Power Supply | Linear Regulated DC Input |
| Dimensions | 152 × 104 × 42 mm |
| Compliance | IEC 61000-4 Series (EMC Immunity), ISO/IEC 17025 Traceable Calibration Protocol Support |
| Brand | Hywell |
|---|---|
| Model | MHJ-98 |
| Instrument Type | Microwave Power Density Meter (Radiation Dosimetry Grade) |
| Measurement Principle | Broadband RF Field Detection via Calibrated Diode-Based Sensor |
| Frequency Range | 0.9–3 GHz |
| Power Density Range | 0.01–9.99 mW/cm² |
| Accuracy (Full Scale) | ±1.5% |
| Calibration Uncertainty | ±0.75 dB |
| Operating Environment | −10 °C to +40 °C, RH 51–81%, Light-Shielded Sensor |
| Display | LED Digital, 3½-digit Resolution |
| Alarm Output | Configurable Threshold, Audible + Visual + Dry Contact Switch (DC 24 V / 1 A max) |
| Dimensions | 100 × 210 × 35 mm |
| Weight | 0.5 kg |
| Compliance | Designed for IEC 61326-1 (EMC), IEC 61000-4 Series Immunity Testing |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VDH-01 |
| Pricing | Available Upon Request |
| Standard Compliance | IEC 62493:2015+A1:2021 |
| Frequency Range | 20 kHz – 10 MHz |
| Output Impedance | 50 Ω |
| Interface | BNC |
| Sensor Diameter | 210 mm |
| Cable Length | 300 mm |
| Weight | 1.7 kg |
| Brand | IMI Medcom |
|---|---|
| Origin | USA |
| Model | Inspector |
| Detection Principle | Geiger-Müller (GM) Tube with Mica End-Window |
| Radiation Types | Alpha (α), Beta (β), Gamma (γ), and X-ray |
| Display | Digital LCD |
| Detector | Internal GM tube (45 mm effective mica window diameter) |
| Power Supply | One 9V alkaline battery (typical life: 200 hours) |
| Timer | Adjustable built-in timer |
| Calibration | External calibration port |
| Compliance | Designed for field-deployable radiation safety surveys per ANSI N42.33, IEC 60846, and ISO 4037-3 guidelines |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DIgialert-100 |
| Pricing | Upon Request |
| Display | LCD digital display with red LED alarm indicator |
| Operating Temperature Range | –10 °C to +50 °C |
| Detector Type | M-type GM tube with integrated beryllium-window (ICA) for alpha/beta/gamma detection |
| Sensitivity | 1000 CPM per mR/hr (calibrated with Cs-137) |
| Accuracy | ±10% typical |
| Dose Rate Range | 0.001–50 mR/hr |
| Count Rate Range | 0–50,000 CPM |
| Accumulated Count Range | 0–9,999,000 counts |
| Radiation Types Detected | Alpha (α), Beta (β), Gamma (γ), and X-rays |
| Audio Output | Audible alarm via 3.5 mm headphone jack |
| Power Supply | One 9 V alkaline battery (IEC 6LR61) |
| Battery Life | Up to 2000 hours (typical continuous operation) |
| Weight | 0.5 kg |
| Probe Integration | Integrated collimated GM detector assembly |
| Key | Origin: USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Inspector USB |
| Instrument Type | Dose Rate / Contamination Meter |
| Detector | Halogen-quenched Geiger-Müller tube, 1.77" (45 mm) active diameter, mica window density 1.4–2.0 mg/cm² |
| Sensitivity | 3340 CPM per mR/hr (Cs-137 reference) |
| Energy Response | α ≥ 2.0 MeV, β ≥ 40 keV, γ/X ≥ 10 keV |
| Dose Rate Range | 0.001–100.0 mR/hr (0.001–1000 µSv/hr) |
| Count Rate Range | 0–350,000 CPM |
| Total Count Capacity | 1–9,999,999 counts |
| Display | 4-digit LCD with mode indicators |
| Update Interval | 3 s (adaptive averaging over prior 30 s at low levels) |
| Accuracy | ±10% to ±15% (traceable to NIST standards) |
| Alarm Thresholds | Adjustable 0.001–50 mR/hr or 1–160,000 CPM |
| Audio Alert | 70 dB @ 1 m (user-disableable) |
| Data Interface | USB 2.0 compliant port + CMOS audio output |
| Power | 9 V alkaline battery (typical life: 2160 h background, ~600 h at 1 mR/hr) |
| Operating Temperature | –10 °C to +50 °C |
| Dimensions | 150 × 80 × 30 mm |
| Weight | 275 g (battery excluded) |
| Compliance | CE marked |
| certified per ISO 6980-1 | 2020 (reference radiation fields), calibrated and verified per ANSI N42.33-2021 for portable radiation detection instruments |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | ISI921VF |
| Pricing | Available Upon Request |
| Instrument Type | Spectroradiometer |
| Spectral Channels | 512 / 256 / 128 |
| Spectral Range | 380–1050 nm |
| Spectral Resolution | 2 nm / 4 nm / 8 nm @ 700 nm |
| Wavelength Accuracy | ±0.7 nm / ±1.4 nm / ±2.8 nm |
| Measurement Dynamic Range | >1000:1 (60 dB) |
| Standard Configuration | Host Unit ×1, Optical Head ×1, Smart Battery Charger ×1, Rugged Carry Case ×1, USB Communication Cable ×1, Software CD ×1, 2-m Extendable Handheld Mast ×1 |
| Optional Accessories | Calibrated Reflectance Panels (various sizes & reflectance levels), GPS Module, Synchronized Imaging Module, Extended Mast (~10 m), Indoor Calibration Light Source, Fixed-Position Mounting Frame, BRDF Measurement Rig |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 907-0036, 911-0036 |
| Price | Upon Request |
| Brand | LND Inc. |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | ISOTOPE |
| Instrument Category | Radioactivity Calibrator (Dose Rate / Activity Meter) |
| Instrument Type | Online Monitoring System |
| Sample Form | Solid Sources |
| Measurement Mode | Exposure Rate / Air Kerma Rate |
| Measurement Range | 0–12,000 MCi |
| Sensitivity | ≥1,000 MCi (for Co-60 reference geometry) |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LUPIN 5401 |
| Instrument Category | Ambient Dose Equivalent Rate Meter |
| Instrument Type | Laboratory-Grade |
| Detection Medium | Gas-Filled Proportional Counter |
| Detector Technology | He-3 or BF₃ Thermal-to-Fast Neutron Converter |
| Energy Range | 0.025 eV – 5 GeV |
| Sensitivity | 1 cps per µSv/h (He-3), 0.6 cps per µSv/h (BF₃) |
| Dose Equivalent Rate Range | 10 nSv/h – 100 mSv/h |
| Pulse Field Tolerance | ≤10% deviation at 2 µSv incident dose per pulse |
| Compliance | IEC 61000-4-3 (EMC), IEC 60846-2:2014 (Radiation Protection Instrumentation – Part 2: Ambient and Directional Dose Equivalent Meters for Neutrons) |
| Brand | Medcom |
|---|---|
| Origin | USA |
| Model | CRM-100 |
| Detector Type | Halogen-quenched Geiger-Müller tube with mica end-window (45 mm diameter, 1.5–2.0 mg/cm² density) |
| Radiation Types Detected | Alpha, Beta, Gamma, and X-ray |
| Energy Range | 20 keV – 3 MeV |
| Dose Rate Range | 0.001–110.0 mR/h or 0.01–1100 µSv/h |
| Count Rate Range | 0–3,500 CPS / 0–350,000 CPM |
| Total Count Capacity | Up to 9,999,000 counts |
| Timer Range | Up to 40 hours |
| Sensitivity | ≥1,000 CPM per mR/h (referenced to Cs-137) |
| Accuracy | ±10% typical, ±15% maximum (mR/h and µSv/h modes) |
| Audio Feedback | Click-per-count (user-muteable) |
| Display | 4-digit LCD with mode indicators |
| Output Interface | 3.5 mm mono jack (CMOS-compatible TTL pulse output) |
| Input Interface | 2.5 mm calibration input port |
| Power | One 9 V alkaline battery (typical life: 2,160 hours) |
| Dimensions | 150 × 80 × 30 mm |
| Weight | 225 g (including battery) |
| Certifications | CE, RoHS, WEEE, ISO 9001:2001 & ISO 14001 |
| Brand | Medcom |
|---|---|
| Origin | USA |
| Model | Radalert100 |
| Detection Principle | Halogen-quenched Geiger-Müller tube |
| Energy Range | 20 keV – 3 MeV |
| Dose Rate Range (mR/hr) | 0.001 – 110.0 |
| Dose Rate Range (µSv/hr) | 0.01 – 1100 |
| Count Rate (CPM) | 0 – 350,000 |
| Count Rate (CPS) | 0 – 3,500 |
| Total Count Capacity | 1 – 9,999,000 |
| Calibration Source | ¹³⁷Cs (γ) |
| Sensitivity | 1,000 CPM per mR/hr (referenced to ¹³⁷Cs) |
| Accuracy | ±10% typical, ±15% maximum |
| Display | 4-digit LCD with mode indicators |
| Audio/Visual Alert | User-adjustable threshold, LED flash per count |
| Interface | 3.5 mm output jack (0–9 V, 1 kΩ impedance), 2.5 mm calibration input |
| Power | 9 V alkaline battery (≥700 h typical life) |
| Dimensions | 150 × 80 × 30 mm |
| Weight | 323 g (including battery) |
| Compliance | CE-marked |
| Brand | Huiyan |
|---|---|
| Model | MHJ-3 |
| Instrument Type | Microwave Power Density Meter |
| Frequency Range | 0.9–3 GHz |
| Antenna Gain | >2 dBi |
| Measurement Range | 0.2 µW/cm² to 20 mW/cm² |
| Dimensions | 118 mm × 60 mm × 39 mm |
| Weight | <80 g |
| Power Supply | Passive (RF-powered, no battery required) |
| Compliance | Designed for IEC 60705:2017 (Household Microwave Ovens – Methods for Measuring Performance) and FDA 21 CFR §1030.10 (Performance Standard for Microwave and Radio Frequency Emitting Products) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | ML-91 |
| Price | USD 950 (FOB Jiangsu) |
| Operating Temperature | −10 °C to +40 °C |
| Relative Humidity | 66 % ±15 % RH |
| Atmospheric Pressure | 750 mmHg ±30 mmHg |
| Frequency Band | 3–33 cm (i.e., 0.9–10 GHz) |
| Power Density Range | 0.2 µW/cm² to 20 mW/cm² |
| Display | 3-digit LED, auto-ranging across 200 µW/cm² / 2 mW/cm² / 20 mW/cm² scales with LED range indicators |
| Alarm Threshold | Adjustable, default ≥5 mW/cm² |
| Calibration Field Accuracy | ±0.75 dB |
| Full-Scale Indication Error (at rated voltage) | ≤±1.5 % |
| Indicator Dimensions | 82 mm × 40 mm × 172 mm |
| Net Weight | 0.8 kg |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M1000 |
| Instrument Class | Neutron Dose Rate Meter |
| Form Factor | Portable |
| Detector Technology | Gas-filled Proportional Counter with Silicon Photomultiplier (SiPM) Readout |
| Measurement Principle | Thermal/Epithermal Neutron Detection via ³He(n,p)³H Reaction (Indirect Scintillation Conversion) |
| Effective Detection Range | Up to 2 m from source |
| Sensitivity | 1 cps per nanogram ²⁵²Cf equivalent neutron emission rate |
| Operating Temperature Range | −10 °C to +50 °C (with onboard temperature compensation) |
| Compliance | IEC 60846-2:2018, ANSI N42.33-2022, ISO 8529-1:2022 |
| Brand | NewSenda |
|---|---|
| Origin | Sichuan, China |
| Model | CIT-3800 HPGe |
| Instrument Type | Laboratory Gamma-Ray Spectrometer |
| Detector Type | High-Purity Germanium (HPGe) |
| Measurement Range | 5 keV – 10 MeV |
| Energy Resolution | ≤1.8 keV FWHM at 1.332 MeV (⁶⁰Co) |
| Peak Area Precision | <3% RSD (0–50,000 cps) |
| Sample Form | Solid |
| Cooling Method | Liquid Nitrogen or Electromechanical Cryocooler |
| Shielding | Low-Background Lead Castle (≥10 cm Pb + Cu/Cd liners) |
| Digitization | Digital Pulse Processing (DPP) with 14-bit ADC, 100 MS/s sampling |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NSN31045-111YY-S |
| Instrument Type | Portable |
| Instrument Kind | Spectrometer |
| Measured Medium | Solid |
| Detector Type | Gas-filled Proportional Counter |
| Radiation Type | Neutrons |
| Dose Rate Range | 0.01 μSv/h to 99.99 mSv/h |
| Dose Range | 0.01 μSv to 99.99 mSv |
| Energy Range | 0.025 eV to 15 MeV |
| Dose Rate Accuracy | ≤ ±15% at 10 μSv/h |
| Dose Accuracy | ≤ ±25% at 0.05 μSv |
| Angular Dependence | ≤ ±25% (±90° from reference axis) |
| Gamma Rejection | <1 mSv/h (effectively insensitive) |
| Battery Life | >12 h (continuous display) |
| Operating Temperature | –10 °C to +45 °C |
| Operating Humidity | 35–90% RH (non-condensing) |
| Dimensions | Φ164 mm × 289.5 mm |
| Weight | ~3 kg |
| Interface | USB |
| Compliance | IEC 61005 |
| Brand | ORTEC |
|---|---|
| Origin | USA |
| Model | Alpha-Duo |
| Configuration | Desktop dual-channel alpha spectrometry system with independent vacuum, HV, preamplifier, and digital MCA per channel |
| Compliance | Fully compatible with NIM-standard signal protocols and vacuum interlock safety requirements |
| Software Control | Full PC-based control via USB interface |
| Detector Support | Compatible with PIPS (Passivated Implanted Planar Silicon) detectors up to 3000 mm² (system-dependent) |
| Vacuum System | Integrated programmable two-stage vacuum control (roughing + high-vacuum) per channel |
| High Voltage Range | 0–100 V DC programmable, 0.1 V resolution |
| Pulse Processing | Variable-amplitude pulser for energy calibration and resolution optimization |
| Leakage Current Monitoring | Real-time analog monitoring with alarm threshold setting |
| Data Acquisition | Dual independent 4096-channel digital multichannel analyzers (MCAs) |
| Operating Environment | Lab-grade temperature stability (15–30 °C), <60% RH non-condensing |
| Certification | CE-marked |
| Brand | ORTEC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CSS |
| Instrument Type | Laboratory Gamma-Ray Spectrometer |
| Detector Type | High-Purity Germanium (HPGe), N-type Coaxial |
| Measured Radiation | Gamma Rays |
| Energy Range | 3 keV – 10 MeV |
| Peak-to-Compton Ratio | >1000:1 (¹³⁷Cs) |
| Background Count Rate | <0.5 cps (50 keV – 2 MeV, Anti-Compton mode) |
| Relative Efficiency | >60% |
| Resolution | Comparable to ORTEC GMX60 Reference Detector |
| Cooling | Liquid Nitrogen or Electromechanical Cryocooler (No LN₂ Required) |
| Sample Form | Solid (e.g., filter papers, Petri dishes) |
| Software | GammaVision® v7+ with Full 21 CFR Part 11 Compliance Support |
| Brand | ORTEC |
|---|---|
| Origin | USA |
| Model | DETECTIVE 200 |
| Detector Type | Portable HPGe Gamma-Ray Spectrometer |
| Effective Crystal Area | ~5657 mm² |
| Angular Acceptance (with Collimator) | 120° |
| Ingress Protection Rating | IP67 |
| Buoyancy | Floats on Water |
| Relative HEU Identification Speed vs. NaI | Up to 10× Faster |
| Primary Application Domain | Radiological Emergency Response, Nuclear Security, SNM Detection |
| Brand | ORTEC |
|---|---|
| Origin | USA |
| Model | DSPEC-50 |
| Interface | USB 2.0 & Ethernet (TCP/IP) |
| Display | Integrated large LCD panel |
| Detector Compatibility | HPGe, Si(Li), NaI(Tl), and other pulse-mode radiation detectors |
| Dead Time Correction | Advanced real-time algorithm |
| LFR (Low-Frequency Noise Rejection) | Enabled |
| Count Rate Capability | Up to 30% higher throughput at ultra-high count rates |
| Resolution Enhancement | Mitigates EC-induced resolution degradation |
| Form Factor | Benchtop digital multichannel analyzer (MCA) |
| Brand | ORTEC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GEM |
| Instrument Type | Laboratory Gamma Spectrometer |
| Detector Type | P-Type Coaxial High-Purity Germanium (HPGe) Detector |
| Radiation Type | Gamma Rays |
| Energy Range | 40 keV – 10 MeV |
| Energy Resolution | 1.75–2.3 keV FWHM at 1332 keV (dependent on relative efficiency) |
| Brand | ORTEC |
|---|---|
| Origin | USA |
| Model | GEM-C65 |
| Cryocooler Type | SunPower Stirling Engine (200,000-hour MTBF) |
| Liquid Nitrogen Dewar Capacity | 28 L |
| Continuous Operation Without Refill | >2 years (with uninterrupted power) |
| Dewar Height (excl. detector) | 66.5 cm |
| Dewar Diameter (excl. detector) | 44.1 cm |
| Power Consumption | 125 W (typical), 300 W (max at startup) |
| Operating Temperature | 0–40 °C |
| Relative Humidity | 20–90% RH (non-condensing) |
| Acoustic Noise | <60 dB at 1 m |
| Maintenance Interval | Air filter cleaning/replacement every 2 months |
| Alarm Function | Visual & audible alert issued 48 h prior to LN₂ depletion |
| Display Interface | Integrated alphanumeric LCD showing cryostat status and real-time LN₂ level |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories |
| Brand | ORTEC |
|---|---|
| Origin | USA |
| Model | GEM-S |
| Detector Type | Planar High-Purity Germanium (HPGe) |
| Radiation Type | Gamma Rays |
| Energy Range | 3 keV – 5 MeV |
| Energy Resolution (FWHM) | ≤ 0.35 keV @ 5.9 keV (GEM-S5020) to ≤ 0.56 keV @ 5.9 keV (GEM-S9430) |
| Peak Shape (FW.1M/FWHM) | ≤ 1.8 – 2.1 |
| Peak-to-Compton Ratio (≥) | 70 – 108 |
| Relative Efficiency (@1.33 MeV) | 10% – 65% |
| Crystal Diameter | 50 – 94 mm |
| Crystal Thickness | 20 – 30 mm |
| Endcap Window Diameter | 28 – 65 mm |
| Operating Temperature | Liquid Nitrogen Cooled (77 K), Stable at Room Temperature for Storage Only |
| Compliance | ASTM E1452, IEC 61452, ISO 8529-1, NIST-traceable calibration protocols |
| Brand | ORTEC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | GMX |
| Instrument Type | Laboratory Gamma-Ray Spectrometer |
| Detector Type | N-Type Coaxial High-Purity Germanium (HPGe) |
| Radiation Type | Gamma Rays |
| Energy Range | 3 keV – 10 MeV |
| Energy Resolution | 1.8–2.5 keV FWHM at 1332 keV (dependent on relative efficiency) |