Refrigeration Equipment
Filter
Showing 91–120 of 199 results
| Brand | JULABO |
|---|---|
| Origin | Germany |
| Model | SC Series |
| Cooling Method | Water-Cooled |
| Temperature Range | -20 to +130 °C |
| Temperature Stability | ±0.1 °C |
| Circulating Pump Pressure | 4.3 bar |
| Circulating Pump Flow Rate | 33 L/min |
| Reservoir Volume | 21–60 L |
| Operating Mode | Continuous |
| Heating Power | Up to 12 kW |
| Refrigeration Power | Up to 10 kW |
| Construction | Stainless Steel & Chemically Resistant Polymers |
| Compliance | CE, RoHS, ISO 9001 Certified |
| Brand | KIRSCH |
|---|---|
| Origin | Germany |
| Model | LABEX-125 |
| Type | Upright |
| Capacity | 120 L |
| Operating Temperature Range | 2–20 °C |
| Explosion Protection Class | Ex II 3G T6 |
| Insulation Thickness | 50 mm |
| Door Configuration | Reversible Left/Right Swing |
| Interface | RS485 |
| Alarm | Audible & Visual, Remote Alarm Output |
| Defrost System | Automatic with Safety Sensor |
| Cooling System | Forced-Air Circulation with Removable Condenser |
| Control | Membrane Keypad with Digital Display, Min/Max Temperature Memory, Panel Lock Function |
| Interior | White Impact-Resistant Plastic with Embedded Shelf Rails |
| Shelving | Two Coated Plastic Shelves + One Drawer with Adjustable Longitudinal and Six Transverse Dividers |
| Exterior | White Powder-Coated Galvanized Steel |
| Sealing | Replaceable Magnetic Gasket |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Model | H35 |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | −5 to 35 °C |
| Cooling Capacity | 350 W (at 20 °C ambient) / 500 W (at 25 °C ambient) |
| Temperature Stability | ±0.3 °C |
| Circulation Pump Pressure | 1.0 bar |
| Circulation Flow Rate | 3.5 L/min |
| Reservoir Volume | 1.8 L |
| Operation Mode | Continuous |
| Control Technology | PID Digital Temperature Control + Hot Gas Bypass Compressor Modulation |
| Heat Exchanger | Plate-Type |
| Refrigerant | R134a (CFC-free, ozone-friendly) |
| Display | Backlit LCD |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Model | H500 |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Stability | ±0.2 °C |
| Design Architecture | Separated Refrigeration and Heat Dissipation Units |
| Low-Temperature Operation Capability | Functional at outdoor ambient temperatures down to −25 °C |
| Control Interface | Full-Color Touchscreen with Real-Time Multi-Parameter Display |
| Safety System | 13 Diagnostic Alarm Codes |
| Operational Flexibility | 12 Configurable System Parameter Sets |
| Hot Gas Bypass Technology | Integrated |
| PID Digital Temperature Control | Standard |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Control Range | –40 °C to +100 °C |
| Temperature Stability | ±0.05 °C (at setpoint, under stabilized conditions) |
| Bath Material | Seamless 304 Stainless Steel |
| Interface | RS485 for Remote Monitoring and Control |
| Safety Features | Dual High/Low Temperature Alarm, Low-Level Liquid Alarm |
| Circulation Mode | Switchable Internal/External Loop via Manual Knob |
| Power Supply | 220–240 VAC, 50/60 Hz |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Model | SMART Series |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Air-Cooled |
| Temperature Range | 8–35 °C (Low-Temperature Models: −20 to 35 °C) |
| Refrigeration Capacity | 1000 W (@25 °C ambient) |
| Temperature Stability | ±0.1 °C |
| Circulation Pump Pressure | 3 bar (43.5 psi) |
| Flow Rate | 6.4 L/min |
| Reservoir Volume | ~5 L |
| Operating Mode | Continuous Duty (Hot Gas Bypass Control) |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | RP 290 EC |
| Cooling Method | Hybrid (Air- and Water-Cooled) |
| Temperature Range | –90 °C to +200 °C |
| Cooling Capacity | 800 W at 20 °C |
| Temperature Stability | ±0.05 °C |
| Circulating Pump Pressure | 0.68 bar |
| Flow Rate | 22 L/min |
| Reservoir Volume | 2.4–4.4 L |
| Heating Power | 2.5 kW |
| Max. Power Consumption | 3.7 kW |
| Refrigerants | R-452A (0.300 kg, GWP 2140) & R-170 (0.070 kg, GWP 3) |
| Compliance | DIN 12876, EU F-Gas Regulation (EU) No. 517/2014 |
| Interface Options | USB, Ethernet, RS-232/485, Profibus, EtherCAT, Analog I/O |
| Pump Type | LAUDA Varioflex (8-stage adjustable, pressure/suction capable) |
| Display | 5.7″ multi-touch color LCD |
| Programmability | 100 programs × 50 segments |
| User Management | Up to 20 users |
| Safety | Adjustable overtemperature protection with acoustic alarm |
| Dimensions (W×D×H) | 390 × 600 × 685 mm |
| Weight | 80 kg |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | UC 80 |
| Cooling Type | Water-Cooled |
| Temperature Control Range | –10 to 35 °C |
| Temperature Stability | ±0.5 °C |
| Refrigeration Capacity | 80.0 kW (at 10 °C outlet water temperature) |
| Circulating Pump Pressure | 3.0 bar |
| Circulating Pump Flow Rate | 250 L/min |
| Reservoir Volume | 125 L |
| Operation Mode | Continuous |
| Configuration | Split-System |
| Compliance | EU Ecodesign Directive (EU) 2016/2281, EN 60335-1, EN 60335-2-40 |
| Brand | Liebherr |
|---|---|
| Origin | Germany |
| Model | LGex 3410 |
| Type | Upright |
| Volume | 310 L |
| Operating Temperature Range | −9 °C to −30 °C |
| Cooling System | Static (Natural Convection) |
| Defrosting | Manual |
| Insulation Thickness | 70–70 mm |
| Refrigerant | R600a |
| Climate Class | SN-ST |
| Power Consumption | 1.309 kWh/24h |
| Dimensions (W×D×H) | 600 × 615 × 1840 mm |
| Door | Reversible, Double-Glazed, Self-Closing, Lockable |
| Interior | Plastic Liner with Adjustable Glass Shelves (440 × 420 mm), 8 Drawers |
| Safety Features | Visual & Audible Alarm, Voltage Loss Contact, Grounded Metal Components, Spark-Free Interior Construction |
| Brand | Liebherr |
|---|---|
| Origin | Germany |
| Model | LKexv 5400 |
| Type | Upright |
| Total Volume | 554 L |
| Operating Temperature Range | +1 °C to +15 °C |
| External Dimensions (W×D×H) | 750 × 730 × 1640 mm |
| Energy Consumption | 0.983 kWh/24h |
| Climate Class | SN-T |
| Refrigerant | R600a |
| Control System | Mechanical |
| Temperature Display | External Digital |
| Shelving | 5 Adjustable Glass Shelves (440 × 425 mm) |
| Cabinet Material | Powder-Coated Steel (White) |
| Interior Liner | Plastic |
| Door Handle | Ergonomic Thin-Profile Locking Handle |
| Door Hinge | Reversible |
| Condensate Collection Pan | Integrated ATEX-Compliant Pan |
| Certification | ATEX II 2G Ex nA IIC T6 Gc (Electrosuisse Certified) |
| Brand | Liebherr |
|---|---|
| Country of Origin | Austria |
| Model | SRFfg 4001 |
| Type | Upright |
| Total/Net Capacity | 394 / 298 L |
| Operating Temperature Range | +3 °C to +16 °C |
| Energy Consumption | 421 kWh/365 days |
| Cooling System | Fan-cooled |
| Refrigerant | R 600a |
| Control Interface | Monochrome Display with Touch Buttons |
| Temperature Stability | ±3 °C |
| Ambient Temperature Range | +10 °C to +35 °C |
| Noise Level | 49 dB(A) |
| Voltage/Frequency | 220–240 V~, 50 Hz |
| Door Material | Steel |
| Cabinet Finish | White Steel |
| Adjustable Shelves | 5 (Glass) |
| Shelf Load Capacity | 40 kg per shelf |
| Unit Weight Capacity | 225 kg |
| Compliance | ATEX 2014/34/EU, EN 1127-1, IEC 60079-0, IEC 60079-15, IEC 61010-2-011 |
| Brand | Liebherr |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | SRFfg 5501 |
| Instrument Type | Upright |
| Total/Net Volume | 558 / 441 L |
| Operating Temperature Range | +3 °C to +16 °C |
| Refrigerant | R600a |
| External Dimensions (W/D/H) | 747 × 769 × 1684 mm |
| Internal Dimensions (W/D/H) | 600 × 537 × 1460 mm |
| Annual Energy Consumption (365 days) | 1399 kWh |
| Ambient Temperature Range | +10 °C to +35 °C |
| Heat Output | 408 kJ/h |
| Noise Level | 49 dB(A) |
| Voltage/Frequency | 220–240 V~, 50 Hz |
| Input Current | 2.0 A |
| Rated Power | 145 W |
| Cooling System/Defrosting | Forced Air / Automatic |
| Temperature Gradient | 3.7 °C |
| Temperature Fluctuation | ±3.0 °C |
| Cabinet Surface Material | Steel, White Finish |
| Door Material | Steel |
| Interior Liner | Commercial-grade molded polystyrene |
| Control Interface | Monochrome display with touch buttons |
| Power Failure Alarm | Visual & audible alarm on power restoration |
| SmartMonitoring Compatibility | Yes, via optional SmartModule |
| Connectivity Options | Optional WiFi/LAN interface |
| Adjustable Shelves | 5 |
| Shelf Material | Tempered glass |
| Shelf Dimensions (W/D) | 600 × 537 mm |
| Shelf Load Capacity / Unit Weight Capacity | 40 kg / 300 kg |
| Handle Type | Ergonomic handle with assisted-opening mechanism |
| Access Port | 1 × Ø10 mm |
| ATEX Compliance | Yes (Directive 2014/34/EU, ATEX 95) |
| Lock Type | Mechanical lock |
| Hinge Configuration | Right-hinged (field-reversible) |
| Gross/Net Weight | 91 / 80 kg |
| Brand | Liebherr |
|---|---|
| Origin | Germany |
| Model | SRFfg 5501 |
| Type | Upright |
| Capacity | 558 L |
| Operating Temperature Range | +3 °C to +16 °C |
| Cooling System | Forced-Air (Fan-Cooled) |
| Refrigerant | R600a |
| Temperature Control Accuracy | ±0.1 °C |
| Certification | ATEX 95 (2014/34/EU) |
| Climate Class | SN-ST (10–35 °C ambient) |
| Noise Level | Low sound power level |
| Power Interface | Volt-free alarm contacts |
| Communication | RS485 interface for multi-unit monitoring (up to 20 units) |
| Optional External Sensor | PT100 probe support |
| Defrosting | Automatic, spark-free design |
| Door | Reversible hinge |
| Shelf Load Capacity | 40 kg per glass shelf |
| Construction | Stainless steel cabinet, GlassLine tempered glass doors |
| Energy Efficiency | High-efficiency electronic control + optimized refrigeration cycle |
| Brand | Millrock |
|---|---|
| Origin | USA |
| Model | EPIC 85 |
| Shelf Area | 1.394–2.787 m² |
| Condenser Capacity | 50 L |
| Condenser Temperature | –85 °C |
| Shelf Temperature Range | –70 to +65 °C |
| Chamber Material | 316L Stainless Steel |
| Vacuum Sensor | Standard Pirani Gauge |
| Condenser Type | Coil-Type with Hot-Gas Defrost |
| Control System | PC/PLC-Based with Ethernet Connectivity |
| Optional | ISO Class 5 Cleanroom Configuration, H₂O₂ Sterilization Port, Isolation Interface |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MK 600 W Screw-Type |
| Pricing | Upon Request |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Manifold Benchtop Freeze Dryer |
| Application Scale | Pilot-Scale |
| Freeze-Drying Area | 0.12 m² |
| Ultimate Vacuum | ≤5 Pa |
| Condensate Capacity (24 h) | 4 kg/batch |
| Cold Trap Temperature | ≤−56 °C |
| Dimensions (L×W×H) | 600 × 450 × 720 mm + 440 mm (condenser height) |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Model | Scientz-25T |
| Instrument Type | Standard Shelf-Type Freeze Dryer |
| Application | Laboratory-Scale Lyophilization |
| Freeze-Drying Area | 2.5 m² |
| Ultimate Vacuum | ≤10 Pa |
| Condensate Capacity (24 h) | 15 kg/24 h |
| Cold Trap Temperature | ≤ −85 °C |
| Dimensions (W×D×H) | 2300 × 1200 × 2200 mm |
| Control System | PLC + Touchscreen HMI |
| Data Compliance | FDA 21 CFR Part 11–Ready Audit Trail & Exportable Log Files |
| Refrigeration Technology | Single-Unit Self-Contained Cascade Refrigeration System |
| Valve Actuation | Individual Silicone Rubber Stopper Valves per Flask |
| Optional Accessories | Customizable Flask Racks, Glass Vials, Vacuum Inlet Nozzles, Nitrogen Backfill Valve |
| Brand | PEAK |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Equipment |
| Model | Titan LN480–LN960 |
| Pricing | Available Upon Request |
| Brand | NOKI |
|---|---|
| Origin | Jiangsu, China |
| Model | DC-2010 |
| Capacity | 10 L |
| Temperature Range | −20 °C to +100 °C |
| Bath Chamber Dimensions | 290 × 200 × 180 mm (W×D×H) |
| Depth | 180 mm |
| Opening Size | 160 × 120 mm |
| Flow Rate | 8 L/min |
| Heating Power | 1 kW |
| Refrigeration Capacity | 280–1100 W |
| Temperature Display Resolution | 0.1 °C |
| Control Method | PID-based microprocessor control |
| Internal/External Circulation | Yes |
| Over-Temperature & Over-Current Protection | Yes |
| Compressor Type | High-efficiency low-noise anti-interference compressor |
| Display | Dual LED digital display (red PV / green SP) |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Microstat |
| Temperature Range | 1.5 K to 300 K (depending on configuration) |
| Cooling Method | Closed-cycle helium cryocooler or liquid helium flow cryostat |
| Optical Access | Dual windows (UV to FIR transmission, optional AR coatings) |
| Electrical Feedthroughs | Up to 24 low-noise coaxial or twisted-pair leads |
| Footprint | Compact benchtop design (< 300 mm × 300 mm base) |
| Vibration Isolation | Active/passive hybrid stage stabilization |
| Compliance | CE, UKCA, RoHS |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | MicrostatHiRes |
| Temperature Range | 2.7 K – 500 K (with optional rotary pump) / 3.4 K – 500 K (standard) |
| Base Temperature Stability | ±0.1 K |
| Helium Consumption at 4.2 K | < 0.70 L/hr (with low-loss transfer line) |
| Cool-down Time from RT to 4.2 K | ~15 min (with pre-cooled transfer line) |
| Working Distance | 2.2 mm |
| Sample Vibration | < 20 nm (measured in SEM environment) |
| Mass | 1.5 kg |
| Controller | Mercury iTC |
| Communication Interfaces | RS232, USB (serial emulation), TCP/IP, GPIB |
| Software Integration | LabVIEW driver library and virtual instrument support |
| Compliance | Designed for GLP/GMP-adjacent research environments |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Optistat |
| Price Range | USD 13,500 – 40,500 (FOB UK) |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Optistat Dry |
| Temperature Range | < 3 K to 300 K |
| Cool-down Time | ≤120 min to 10 K |
| Optical Aperture | Up to 28 mm diameter |
| Numerical Aperture | f/1 |
| Electrical Feedthroughs | Up to 12 leads |
| Cooling Options | Air-cooled or water-cooled cryocooler |
| Vibration Level | < 10 µm (when mounted on optical table) |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories, compatible with GLP/GMP data integrity requirements |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Optistat Dry |
| Price Range | USD 42,000 – 70,000 |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Proteox 5 mK |
| Cooling Principle | Helium-3/Helium-4 Dilution Refrigeration |
| Base Temperature | < 5 mK |
| Magnet Compatibility | Integrated or Standalone Oxford Superconducting Magnets (up to 18 T) |
| Cryogenic Architecture | Dry, Helium-Free Operation |
| System Configuration | Turnkey Cryostat with Vibration-Isolated Mixing Chamber and Thermal Anchoring Stages |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Proteox |
| Cooling Principle | Continuous He-3/He-4 Dilution Refrigeration |
| Base Temperature | ≤ 10 mK (typical) |
| Experimental Bore Diameter | 360 mm |
| Secondary Insert Capacity | Up to 2 × ISO100 feedthroughs |
| Additional Feedthroughs | Up to 2 × KF40 + 2 × KF25 |
| Thermal Management | Patented Gas-Gap Heat Switch System |
| Magnet Integration | Fully compatible with Oxford Instruments superconducting magnets |
| Software Platform | Web-based, cross-platform control with audit-trail logging |
| Maintenance Cycle | Extended via automated gas-handling bypass system |
| Sample Exchange | Optional bottom-loading rapid sample transfer mechanism integrated at secondary insert level |
| Compliance | Designed for GLP/GMP-aligned laboratory environments |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | SpectromagPT |
| Temperature Range | 1.6 K – 300 K |
| Magnetic Field Strength | Up to 7 T |
| Optical Access | Dual-axis (parallel & perpendicular to field) |
| Sample Chamber Diameter | 30 mm |
| Temperature Stability (standard probe) | ±0.1 K |
| Cool-down Time (room temp → 4 K) | ~40 h |
| Probe Cool-down Time (to <2 K, cold insert) | <90 min |
| Field Ramp Time (to max field) | ≤60 min |
| Continuous Operation Duration | >4 weeks |
| Cryocooler Type | Closed-cycle, helium-free |
| Sample Exchange | Top-loading, no lock-in mechanism required |
| Thermal Environment | Static exchange gas cooling (no convective flow) |
| Optional Sample Stage | ±15 mm axial translation + 360° rotation about vertical axis |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | TeslatronPT |
| Maximum Magnetic Field | 18 T |
| Temperature Range | 1.5 K to 300 K (standard VTI) |
| Sample Bore Diameter | 50 mm |
| Cooling Method | Single-pulse-tube cryocooler |
| Sample Access | Top-loading probe mechanism |
| Vibration Level | Ultra-low (suitable for SQUID, STM, and optical spectroscopy) |
| Internal Cold Trap | Yes |
| Gas Exchange Mode | Static exchange gas (no forced flow across sample) |
| Compliance | Designed for GLP/GMP-adjacent research environments |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Triton |
| Cooling Power | >12 µW @ 20 mK (Triton 500), >6 µW @ 20 mK (Triton 300) |
| Base Temperature | < 10 mK |
| Sample Space | Ø290 mm × H240 mm (extendable to 440 mm) |
| Magnetic Field Compatibility | Up to 14 T |
| Helium-3 Inventory | 18 L (Triton 500), 11 L (Triton 300) |
| Cool-down Time | < 24 h |
| Operating Temperature Range | 10 mK – 30 K (full field) |
| Cryocooler | 1–2 W Pulse Tube Refrigerator |
| Compliance | Fully compatible with ISO/IEC 17025-aligned lab infrastructure, supports GLP/GMP audit trails via optional integrated logging |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | TritonXL |
| Minimum Base Temperature | < 5 mK |
| Refrigeration Power | 1000 µW at 100 mK |
| Maximum Magnetic Field Compatibility | Up to 16 T |
| Integrated Cryocoolers | Dual 1.5 W Pulse Tube Refrigerators |
| Standard Warranty | 3 years (covers all system components, including third-party cryocoolers, pumps, and electronics) |
| Service Support | Factory-authorized service network across UK, Germany, USA, China, Japan, and India |
| Vibration Mitigation | Remote pump rack, rigid floor-standing cryostat support, electrical isolation between cryostat, gas lines, and pump station |
| Gas Handling System | Dry, oil-free pumping stack (roots + diaphragm + turbomolecular pumps), fully welded pneumatic circuit with high-integrity solenoid valves |
| Sample Access | Top- and bottom-loading options |
| RF Wiring Capacity | Up to 72 semi-rigid coaxial lines with optimized attenuators |
| Optical Integration | Optional fiber feedthroughs or optical windows |
| Control Interface | Advanced software suite with remote command protocol (TCP/IP), hardware interlocks, and audit-trail-capable operation logging |
