| Brand | AS ONE |
|---|---|
| Origin | Japan |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Imported |
| Model | 2-9652-01 |
| Blade Material | Semi-Transparent Plastic |
| Hub & Spoke Material | Aluminum |
| Adjustable Diameter Range | 500–700 mm |
| Weight | Approx. 530 g |
| Power Source | None (Airflow-Driven) |
| Installation Tool Required | Single Phillips Screwdriver |
| Brand | AS ONE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | C4-2732-01 (SOC-700) / C4-2732-02 (SOC-1100) |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Air-Cooled |
| Temperature Control Range | −15 °C to +30 °C (SOC-700) |
| Refrigeration Capacity | 460 W at ΔT = 10 °C (SOC-700) |
| Temperature Stability | ±1.0 °C |
| Circulation Flow Rate | 12 L/min (SOC-700) |
| Max Head | 8 m (SOC-700) |
| Reservoir Volume | 5.0 L (liquid volume ~4.2 L) |
| Working Mode | Air-Cooled, Closed-Loop Circulation |
| Refrigerant | R-134a |
| Heat Exchanger Material | Brazed Plate Type, SUS316L/SUS304 |
| Reservoir Material | SUS304 |
| External Nozzle | Metal, OD 10 mm (compatible with tubing ID φ8–9 mm) |
| Dimensions (W×D×H) | 212 × 482 × 637 mm |
| Net Weight | 30 kg (SOC-700) |
| Ambient Operating Temperature | 5–30 °C |
| Power Supply | AC 220 V, 50/60 Hz |
| Safety Protections | Leakage Current Protection, Overcurrent Circuit Breaker, Compressor Delay Timer, Low-Water-Level Sensor, Compressor Overload Relay, Upper/Lower Temperature Limit Alarms |
| Brand | Attocube Systems AG |
|---|---|
| Origin | Germany |
| Model | atto CMC |
| Instrument Type | Vertical |
| Base Temperature | 2.3 K |
| Vibration Stability | High |
| Dimensions | 446 × 266 × 641 mm³ |
| Cooling Method | Air-Cooled |
| Refrigeration Power | 50 mW @ 2.8 K |
| Cold Head Diameter | 45 mm |
| Electrical Feedthroughs | Standard 6, Optional 12 |
| Max. Electrical Power Consumption | 1.4 kW |
| IGLU Compressor Integration | Yes |
| Rack-Mountable | 19-inch compatible |
| Control | Remote via Ethernet/RS232 |
| Automation Level | Fully Automated Cool-Down & Operation |
| Brand | Attocube Systems AG |
|---|---|
| Origin | Germany |
| Model | attoCMC |
| Instrument Type | Vertical |
| Base Temperature | 2.3 K |
| Vibration Stability | High |
| Dimensions | 446 × 266 × 641 mm³ |
| Cooling Method | Air-Cooled |
| Refrigeration Power | 50 mW @ 2.8 K |
| Cold Head Diameter | 45 mm |
| Electrical Feedthroughs | Standard 6, Optional 12 |
| Max. Electrical Power Consumption | 1.4 kW |
| Brand | attocube Systems AG |
|---|---|
| Origin | Germany |
| Model | attoDRY800 / attoDRY1000 / attoDRY1100 / attoDRY2100 |
| Cooling Principle | Pulse-tube cryocooler |
| Base Temperature | 3.8 K (attoDRY800), 4 K (attoDRY1000/1100), 1.5–1.8 K (attoDRY2100) |
| Temperature Range | 1.5–320 K (model-dependent) |
| Temperature Stability | < ±5 mK (attoDRY2100), < ±10 mK (attoDRY1000/1100), < ±15 mK (attoDRY800) |
| Vertical Vibration Amplitude (Z-axis) | < 0.15 nm (attoDRY1000/1100/2100), < 5 nm peak-to-peak (attoDRY800) |
| Sample Chamber Diameter | 49.7 mm (attoDRY1000/1100/2100), 75 mm (attoDRY800) |
| Magnetic Field Options | Up to 9 T (superconducting), vector magnet configurations available |
| Optical Access | Integrated optical vacuum chamber with high-NA low-temperature objectives (NA ≥ 0.8) |
| Control Interface | Touchscreen-based automated temperature & field control (attoDRY1100/2100), manual control (attoDRY800/1000) |
| Refrigeration Power | >5 mW @ 5 K, >1000 mW @ 4.2 K (attoDRY1000/1100/2100) |
| Brand | Attocube Systems AG |
|---|---|
| Origin | Germany |
| Model | attoDRY800 |
| Instrument Type | Upright |
| Temperature Range | 3.8 K to 320 K |
| Temperature Stability | <15 mK |
| Vibration Level | <5 nm peak-to-peak (vertical, 1500 Hz bandwidth) |
| Sample Chamber Diameter | 75 mm |
| Base Pressure | <5×10⁻⁶ mbar |
| Leak Rate | <5×10⁻⁹ mbar·L/s |
| Cool-down Time (to 5 K) | <4.5 h |
| Cooling Power | >170 mW @ 5 K |
| Compressor Power | 3 kW |
| Cooling Method | Closed-cycle, helium-free |
| Dimensions (Optical Table Mounting) | 900 mm × 1800 mm × 305 mm (height of vibration isolation legs: 597 mm) |
| Brand | Attocube Systems AG |
|---|---|
| Origin | Germany |
| Model | attoDRY800xs |
| Instrument Type | Vertical |
| Temperature Range | 3.8 K to 300 K |
| External Dimensions | 17 in × 28 in (432 mm × 711 mm) |
| Cooling Method | Closed-cycle helium refrigeration, helium-free operation |
| Vibration Performance | Sub-microradian angular stability, <5 nm RMS vertical displacement below 10 Hz |
| Vacuum Enclosure | User-customizable, optically accessible, multi-port design |
| Integration Height | Compatible with standard optical table height (762 mm ± 10 mm) |
| Electrical Feedthroughs | 36 DC leads included |
| Optical Compatibility | Designed for low-temperature achromatic objectives (e.g., attoLFT series), ≥12 mm working distance, AR-coated viewports (250–1100 nm) |
| Brand | AUCMA |
|---|---|
| Model | CX-1020 |
| Capacity | 1020 L |
| Temperature Range | 2–8 °C |
| Power Supply | 220 V / 50 Hz |
| Dimensions (W×D×H) | 1288 × 888 × 1936 mm |
| Power Consumption | 450 W |
| Net Weight | 186 kg |
| Gross Weight | 225 kg |
| Refrigerant | R134a |
| Control Accuracy | ±0.1 °C |
| Interior Material | Stainless Steel |
| Door Type | Double-layer Low-E Tempered Glass with Anti-condensation Heating Strip |
| Safety Features | Password-protected Controller, High/Low Temperature Alarms, Sensor Fault Detection, Delayed Start & Compressor Protection Interval |
| Standard Compliance | GB/T 20154–2014 (Chromatography Refrigerators), IEC 61000-6-3 EMC, GB 4706.1 Safety of Household and Similar Electrical Appliances |
| Brand | AUWII® |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | AR Series Industrial Circulating Chiller |
| Instrument Type | Integrated Unit |
| Cooling Method | Air-Cooled |
| Temperature Control Range | 5–35 °C |
| Refrigeration Capacity | 18–190 kW |
| Temperature Stability | ±1 °C |
| Circulating Pump Pressure | 19–55 m H₂O |
| Circulating Pump Flow Rate | 1–32 m³/h |
| Reservoir Volume | 150–900 L |
| Operating Principle | Compressor-Based Vapor-Compression Refrigeration |
| Brand | Axetris |
|---|---|
| Origin | Switzerland |
| Model | EMIRS50_AT06T_BT170 |
| Housing | TO-46 metal can with protective cap |
| Emission Spectrum | 2–14 µm (blackbody-like) |
| Modulation Capability | Electrical (chopper-free) |
| Window Options | Sapphire or Barium Fluoride (BaF₂) |
| Typical Radiant Power | ~15 mW @ 5 V |
| Thermal Time Constant | < 10 ms |
| Operating Voltage Range | 3.3–6 V DC |
| Lifetime | > 50,000 hours (at rated conditions) |
| MEMS Structure | Silicon-based microheater with dielectric emissive coating |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr UT12 |
| Instrument Type | Integrated Unit |
| Cooling Method | Water-Cooled |
| Temperature Control Range | 5–40 °C |
| Cooling Capacity | 1000 W |
| Temperature Stability | ±0.1 °C |
| Circulation Pump Pressure | 2.0 bar |
| Circulation Flow Rate | 38 L/min |
| Reservoir Volume | 19 L |
| Operation Mode | Continuous |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BIOCOOL-ES |
| Instrument Type | Stoppering Freeze Dryer |
| Application Scope | Pilot-Scale |
| Lyophilization Area | 1 m² |
| Ultimate Vacuum | ≤1 Pa |
| Condensate Capacity (24 h) | 15 L |
| Cold Trap Temperature | < −110 °C (enhanced mode down to −165 °C) |
| Dimensions (W×D×H) | 760 × 1440 × 1900 mm |
| Brand | BIOCOOL |
|---|---|
| Origin | Shanghai, China |
| Model | FD-1 |
| Instrument Type | Standard Shelf-Type Freeze Dryer |
| Application | Laboratory Use |
| Lyophilization Area | 0.06 m² |
| Ultimate Vacuum | < 20 Pa |
| Condenser Temperature | ≤ −50 °C |
| Water Capture Capacity | 2 kg/24 h |
| Dimensions (W×D×H) | 492 × 540 × 800 mm |
| Power Supply | 220 V, 50 Hz |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | FD-1A-110+ |
| Instrument Type | Standard Shelf-Type Freeze Dryer |
| Application | Laboratory-Scale Lyophilization |
| Freeze-Drying Area | 0.12 m² |
| Ultimate Vacuum | <3 Pa |
| Condenser Temperature (No-Load) | −110 °C |
| Water Capture Capacity (24 h) | 3 L |
| Refrigeration Compressor | Imported Industrial-Grade Unit |
| Control System | PLC + Touchscreen Interface |
| Sample Temperature Monitoring | Dual PT100 Sensors |
| Optional Features | Pulse Backfill Valve (N₂/Inert Gas), Auto-Defrost, Lyophilization Curve Logging & USB Data Export, Cold Trap Pre-Freezing Function |
| Structural Design | Monolithic Drying Chamber (Welded, Leak-Proof) |
| Condenser Technology | Deep-Cold Trap with Organic Solvent Compatibility (≤95% v/v Volatile Organics) |
| Brand | BIOCOOL |
|---|---|
| Model | FD-1A-80 |
| Cold Trap Temperature | < −80 °C |
| Ultimate Vacuum | < 20 Pa |
| Shelf Area | 0.12 m² |
| Sample Capacity (Liquid) | 1.2 L |
| Shelf Configuration | 4 × Φ200 mm Stainless Steel Trays |
| Cold Trap Dimensions | Φ200 × 200 mm |
| Ice Capacity | 4 kg/24 h |
| Power Supply | 220 V, 50 Hz, 1300 W |
| Overall Dimensions (W×D×H) | 492 × 540 × 800 mm |
| Refrigeration System | Dual-stage Cascade Compressor |
| Chamber Type | Transparent Acrylic Bell Jar |
| Vacuum Interface | Standard ISO-KF 25 |
| Optional | Sample Temperature Monitoring |
| Brand | BioCool |
|---|---|
| Origin | Beijing, China |
| Model | FD-1B-110+ |
| Instrument Type | Stoppering Freeze Dryer |
| Application | Laboratory-Scale Lyophilization |
| Shelf Area | 0.08 m² |
| Ultimate Vacuum | <3 Pa |
| Condenser Temperature (No Load) | -110°C |
| Water Capture Capacity (24 h) | 3 L |
| Refrigeration Compressor | Imported Industrial-Grade Unit |
| Control System | PLC + Touchscreen Interface |
| Sample Temperature Monitoring | Dual Pt100 Sensors |
| Reconstitution Gas Inlet | Pulse-Controlled Inert Gas Backfilling (N₂ or Argon) |
| Compliance | Designed for GLP-compliant workflows |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FD-1B-50 |
| Instrument Type | Manifold-Style with Stoppering Capability |
| Application Scope | Laboratory-Scale Lyophilization |
| Shelf Area | 0.08 m² |
| Ultimate Vacuum | <13 Pa |
| Condenser Temperature | ≤ −50 °C |
| Water Capture Capacity | 3 L/24 h |
| Condenser Dimensions | Φ220 × 130 mm |
| Tray Size | Φ180 mm (3-layer stackable) |
| Power Supply | 220 V, 50 Hz, 850 W |
| Unit Dimensions (W×D×H) | 380 × 600 × 345 mm |
| Bottle Capacity | ~155 × 22 mm vials |
| Optional Features | Sample Temperature Monitoring, Inert Gas Backfill Valve (N₂/Ar) |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | FD-1B-80 |
| Condenser Temperature | < −80 °C |
| Ultimate Vacuum | < 20 Pa |
| Freeze-Drying Area | 0.07 m² |
| Load Capacity (Bulk) | 0.7 L |
| Ice Trapping Capacity | 4 kg/24 h |
| Tray Dimensions | Φ180 mm × 3 layers |
| Power Supply | 220 V, 50 Hz, 800 W |
| Dimensions (W×D×H) | 492 × 540 × 800 mm |
| Refrigeration System | Dual-stage cascade refrigeration with imported hermetic compressors |
| Chamber | Transparent polymethyl methacrylate (PMMA) bell jar |
| Vacuum Interface | Standard KF-25 flange |
| Display | Digital temperature & vacuum readout |
| Optional | Sample temperature probe interface |
| Brand | BIOCOOL |
|---|---|
| Origin | Shanghai, China |
| Model | FD-1C-50 / FD-1C-80 |
| Instrument Type | Manifold-type freeze dryer |
| Application Scale | Pilot-scale |
| Freeze-drying Area | 0.12 m² |
| Ultimate Vacuum | < 20 Pa |
| Condenser Temperature | −50 °C (FD-1C-50) / −80 °C (FD-1C-80) |
| Water Capture Capacity | 3 kg/24 h |
| Condenser Dimensions | Ø200 mm × 4 trays |
| Power Supply | 220 V, 50 Hz, 800–850 W |
| Main Unit Dimensions (W×D×H) | 380×300×645 mm (FD-1C-50) / 500×500×750 mm (FD-1C-80) |
| Standard Configuration | Benchtop主机, 2 L domestic vacuum pump, manifold drying assembly, 8 rubber stopcock valves, 8 glass freeze-drying flasks, stainless steel sample shelf |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | FD-1C-50 |
| Instrument Type | Manifold (Multi-Port) Freeze Dryer |
| Application | Laboratory-Scale Lyophilization |
| Shelf Area | 0.12 m² |
| Ultimate Vacuum | < 20 Pa |
| Condenser Temperature | ≤ −50 °C |
| Water Capture Capacity | 3 L/24 h |
| Condenser Dimensions | Φ220 × 130 mm |
| Sample Tray | Φ200 mm, 4-layer |
| Manifold Ports | 8 independent vacuum-controlled ports |
| Power Supply | 220 V, 50 Hz, 850 W |
| Dimensions (W×D×H) | 350 × 600 × 345 mm |
| Weight | Approx. 42 kg |
| Compliance | Designed for GLP-compliant laboratory environments |
| Software Interface | Digital vacuum & temperature display |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | FD-1C-50+ |
| Instrument Type | Standard Shelf-Type Freeze Dryer |
| Application | Laboratory-Scale Lyophilization |
| Freeze-Drying Area | 0.12 m² |
| Ultimate Vacuum | <9 Pa |
| Condenser Temperature (No Load) | −55 °C |
| Condensate Capacity (24 h) | 3 L |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | FD-1C-80 |
| Condenser Temperature | < −80 °C |
| Ultimate Vacuum | < 20 Pa |
| Freeze-Drying Area | 0.12 m² |
| Shelf Capacity | 4 × Φ200 mm Trays |
| Tray Loading Volume | 1.2 L |
| Condenser Dimensions | Φ200 × 200 mm |
| Ice Capacity | 4 kg/24 h |
| Drying Time (10 mm layer) | ~24 h |
| Flask Compatibility | 8 × (100/250/500/1000 mL) |
| Power Supply | 220 V, 50 Hz, 1300 W |
| Unit Dimensions | 492 × 540 × 800 mm (W × D × H) |
| Refrigeration System | Dual-stage cascade compressor (imported hermetic compressors) |
| Chamber Material | Transparent acrylic bell jar |
| Condenser Material | Electropolished stainless steel (coil-free design) |
| Vacuum Interface | Standard KF-25 (ISO-K) |
| Optional | Sample temperature probe |
| Brand | BioCool |
|---|---|
| Origin | Beijing, China |
| Model | FD-1D-110+ |
| Instrument Type | Stoppering Freeze Dryer |
| Application | Laboratory-Scale Lyophilization |
| Shelf Area | 0.08 m² |
| Ultimate Vacuum | <3 Pa |
| Condenser Temperature (No Load) | -110°C |
| Water Capture Capacity (24 h) | 3 L |
| Refrigeration System | Dual-Stage Cascade Compressor |
| Control System | PLC + Touchscreen Interface |
| Sample Temperature Monitoring | Dual Pt100 Sensors |
| Optional Features | Pulse Backfill Valve (N₂/Inert Gas), Auto-Defrost, Lyophilization Curve Logging & USB Data Export |
| Brand | BIOCOOL |
|---|---|
| Origin | Shanghai, China |
| Model | FD-1D-50 |
| Instrument Type | Stoppering Manifold Freeze Dryer |
| Application Scope | Pilot-Scale |
| Freeze-Drying Area | 0.12 m² |
| Ultimate Vacuum | ≤20 Pa |
| Condensate Capacity (24h) | 3 kg/24h |
| Cold Trap Temperature | −50 °C (FD-1D-50) / −80 °C (FD-1D-80) |
| Dimensions (W×D×H) | 380×600×345 mm (FD-1D-50) / 500×500×750 mm (FD-1D-80) |
| Power Supply | 220 V, 50 Hz, 800–850 W |
| Sample Shelf | Φ180 mm × 3 layers |
| Manifold Ports | 8 standard KF-16 ports |
| Optional | Sample Temperature Monitoring |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | FD-1D-50 |
| Instrument Type | Manifold (Multi-Port) Freeze Dryer |
| Application | Laboratory-Scale Lyophilization |
| Shelf Area | 0.08 m² |
| Ultimate Vacuum | <13 Pa |
| Condenser Temperature | ≤−50 °C |
| Water Capture Capacity | 3 L/24 h |
| Power Supply | 220 V, 50 Hz, 850 W |
| Dimensions (W×D×H) | 380 × 600 × 345 mm |
| Condenser Chamber | Ø220 × 130 mm |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FD-1D-50+ |
| Instrument Type | Stoppering Freeze Dryer |
| Application Scope | Laboratory Use |
| Lyophilization Area | 0.08 m² |
| Ultimate Vacuum | <9 Pa |
| Condensate Capacity (24 h) | 3 L |
| Cold Trap Temperature | −55 °C |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | FD-1D-80 |
| Condenser Temperature | < −80 °C |
| Ultimate Vacuum | < 20 Pa |
| Freeze-Drying Area | 0.07 m² |
| Shelf Capacity | 0.7 L (3 × Φ180 mm trays) |
| Condenser Dimensions | Φ200 × 200 mm |
| Ice Capacity | 4 kg/24 h |
| Drying Time | ~24 h (10 mm sample thickness) |
| Vacuum Chamber | Transparent acrylic bell jar |
| Vacuum Interface | Standard KF-25 |
| Power Supply | 220 V, 50 Hz, 1300 W |
| Dimensions (W×D×H) | 492 × 540 × 800 mm |
| Optional | Sample Temperature Monitoring |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | FD-1E-110+ |
| Instrument Type | Manifold Freeze Dryer |
| Application Scope | Laboratory Use |
| Ultimate Vacuum | <3 Pa |
| Condenser Capacity (24 h) | 3 L |
| Condenser Temperature | −110 °C |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | FD-1E-80+ |
| Instrument Type | Manifold Freeze Dryer |
| Application | Laboratory-Scale Lyophilization |
| Shelf Area | 0.12 m² |
| Ultimate Vacuum | <9 Pa |
| Condenser Temperature (No Load) | −85 °C |
| Condensate Capacity (24 h) | 4 L |
| Brand | BIOCOOL |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | BIOCOOL Freeze Drying Technology Research Center – Custom Process Development Service |
| Pricing | Upon Request |