| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | 6811 |
| Instrument Type | Benchtop Viscometer |
| Viscosity Range | 1–2,000 mPa·s (with ULA adapter) |
| Torque Range | 0.0–100.0% (recommended: 10.0–100.0%) |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Rotational Speed | 0.5–250 rpm (20 discrete steps) |
| Viscosity Resolution | 0.01 mPa·s (≤100 mPa·s), 0.1 mPa·s (100–10,000 mPa·s), 1 mPa·s (>10,000 mPa·s) |
| Viscosity Accuracy | ±1% of full scale |
| Power Supply | 4 × AA alkaline batteries (DC 6 V) or AC adapter (100–240 V AC) |
| Battery Life | ~7 hours (continuous operation at 60 rpm) |
| Data Interface | USB to PC |
| Operating Environment | 10–40 °C ambient, 10–40 °C sample temperature |
| Compliance | Designed for ISO 2555 and ASTM D2196-compliant viscosity measurement workflows |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | VISCO B(L) |
| Instrument Type | Portable Rotational Viscometer |
| Viscosity Range | 12–60,000,000 mPa·s |
| Temperature Range | 5.0–90.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Torque Range | 10.0–100.0% (recommended) |
| Speed Range | 0.01–250 rpm (28 selectable speeds) |
| Viscosity Accuracy | ±1% |
| Standard Spindles | L1, L2, L3, L4 |
| Power Supply | 4× AA alkaline batteries or AC adapter |
| Interface | USB to PC |
| Dimensions (main unit) | 178 × 86 × 194 mm |
| Weight (main unit) | 1.2 kg |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Bostwick Consistometer |
| Pricing | Available Upon Request |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Paddle-Type |
| Pricing | Upon Request |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | V-Series Paddle Spindle (V-71 to V-75, including 5×HB variants) |
| Pricing | Available Upon Request |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | CAP-2000+ |
| Temperature Range (L-Series) | 5–75°C |
| Temperature Range (H-Series) | 50–235°C |
| Shear Rate Range | 10–13,300 s⁻¹ |
| Sample Volume | 24–1700 µL (depending on cone geometry) |
| Cone Angles | 1°, 2°, 4° (standard), custom options available |
| Torque Range | High-torque mode up to 2000+ dyne·cm |
| Compliance | ASTM D4287, ISO 2884, BS 3900, GB/T 9751 |
| Control Interface | Built-in touchscreen + PC via CAPCALC™ software |
| Cone/Plate Gap Adjustment | Motorized auto-gap calibration |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | CAP1000+, CAP2000+ |
| Instrument Type | Rotational Viscometer (Cone-Plate Geometry) |
| Torque Range | High Torque (181,000 dyne·cm) / Low Torque (7,970 dyne·cm) |
| Shear Rate Range | 0.2–15,000 s⁻¹ (dependent on cone spindle and speed selection) |
| Sample Volume | 24–1700 µL |
| Temperature Control | L-Series (5–75°C), H-Series (50–235°C) |
| Display | 4-line LCD |
| Compliance | ASTM D4287, ISO 2884, BS 3900, GB/T 9751 |
| Software | CapCalc32 (PC-based control, data acquisition, rheological modeling) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | CAP2000+ |
| Shear Rate Range | up to 12,000 s⁻¹ |
| Viscosity Range | 0.025–10 cP (with 6 spindles) |
| Sample Volume | < 1 mL |
| Temperature Control | Dual integrated systems |
| Display | Digital LCD |
| Data Acquisition | PC-controlled via proprietary software |
| Compliance | ASTM D4287, ISO 2884, BS 3900 |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model Series | CAP |
| Instrument Type | Rotational Viscometer |
| Mounting Style | Benchtop (Fixed) |
| Operating Environment | High-Temperature Capable |
| Viscosity Range | 20 – 1,500,000 mPa·s |
| Temperature Range | 5–235 °C |
| Torque Options | High Torque (ICI Standard): 181,000 dyne·cm |
| Low Torque | 7,970 dyne·cm |
| Speed Range | 5–1000 rpm (995 programmable increments) |
| Sample Volume | < 1 mL |
| Temperature Control | Peltier-based (L-Series: 5–75 °C |
| H-Series | 50–235 °C) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | Dial Viscometer |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 1–8,000,000 mPa·s |
| Torque Accuracy | ±1% of Full Scale |
| Repeatability | ±0.2% of Full Scale |
| Speed Control | Manual Stepwise (0.3–100 rpm, model-dependent) |
| Calibration Traceability | NIST-Traceable Standard Fluids |
| Power Supply | Universal AC Input (100–240 VAC, 50/60 Hz) |
| Warranty | 2-Year Limited |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DIN Adapter (DAA) |
| Compliance | DIN 53019, ASTM D2196 Equivalent |
| Sample Volume | 16–20 mL |
| Geometry | Cylindrical Couette |
| Shear Rate Calculability | Yes |
| Included Components | 3 rotors + 2 sample cups |
| Viscosity Range (LV/T series) | 1.9–50,000 mPa·s |
| Viscosity Range (RV/HA/HB series) | 10.0–50,000 mPa·s |
| Mounting Compatibility | All Brookfield standard laboratory viscometers and rheometers (DV1, DV2, DV3, RV, HA, HB series) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DIN |
| Compliance | DIN 53019 / ASTM D2196 Equivalent |
| Sample Volume | 16–20 mL |
| Geometry | Cylindrical Couette-type |
| Shear Rate Definition | Well-defined, geometry-determined |
| Viscosity Range (by spindle/viscometer combination) | 1.0–50,000 mPa·s (cP) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DV-II+ Pro |
| Pricing | Available Upon Request |
| Torque | 673.7 dyn·cm |
| Speed Range | 0.01–200 rpm (54 programmable speeds) |
| Spindles | 4 standard spindles included |
| Viscosity Range | 15–2,000,000 cP |
| Display | Digital LCD showing viscosity (cP), % torque, temperature (°C), rotational speed (rpm), and spindle identification |
| Control Interface | Microprocessor-based touchpad control with RS-232 interface for PC connectivity |
| Temperature Sensing | Compatible with RTD temperature probes (e.g., PT100) for real-time thermal monitoring |
| Data Acquisition | Supports DV-Gather™ software for multi-curve overlay (up to 5 simultaneous datasets), synchronized temperature logging, and time-stamped data export |
| Output | RS-232 port for connection to chart recorders or thermal printers for scheduled hard-copy reporting |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Instrument Type | Rotational Viscometer |
| Model | DV-II+Pro EXTRA |
| Bearing System | Precision Ball-Bearing Suspension (excludes LV models) |
| Speed Range | 0.1–200 rpm (54 programmable speeds) |
| Viscosity Accuracy | ±1.0% of reading |
| Repeatability | ±0.2% |
| Displayed Parameters | Viscosity (cP or mPa·s), Temperature (°C or °F), Shear Rate/Shear Stress, % Torque, Rotational Speed, Rotor ID, Timed Stop Countdown |
| Included Accessories | EZ-Lock Quick-Connect Rotor System, Q-Drive Vertical Positioning Stand, Integrated Temperature Probe, RheoCalc Software, DV Loader Software, Standard Rotor Set (4 for LV |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DV1 |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 1–2,000,000 mPa·s |
| Accuracy | ±1.0% of full-scale reading |
| Repeatability | ±0.2% |
| Speed Control | 18 programmable RPM settings (0.3–100 rpm) |
| Display | Large-font, multi-parameter digital LCD |
| Languages | English, Chinese, French, German, Spanish, Portuguese, Russian |
| Interface | USB (compatible with optional Wingather SQ software) |
| Temperature Measurement | Optional RTD probe (DVP-94Y, requires specification at time of order) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | DV2Plus |
| Instrument Type | Rotational Viscometer |
| Mounting Style | Benchtop (Fixed) |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 1–320 × 10⁶ mPa·s |
| Temperature Range | 0–300 °C |
| Compliance | ISO/IEC 17025 Calibration Available, NIST-Traceable Standards, FDA 21 CFR Part 11 Readiness (via optional software module) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DV2Plus |
| Viscosity Range (cP) | LV: 1–6M |
| RV | 100–40M |
| HA | 200–80M |
| HB | 800–320M |
| Speed Range | 0.1–200 rpm (740 programmable steps) |
| Accuracy | ±1.0% |
| Repeatability | ±0.2% |
| Display | 7″ color PCAP touchscreen (800 × 480 resolution) |
| Compliance | Optional 21 CFR Part 11 via DV360™ software |
| Connectivity | Bluetooth, USB-A, USB-B |
| Included Spindles | 4× LV, 6× RV/HA/HB (model-dependent) |
| Built-in Features | Gel time measurement, oscillatory test mode, digital leveling, viscosity test wizard, step-programmable method execution |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | DV2T |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 1 – 320 × 10⁶ mPa·s |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DV2T |
| Instrument Type | Portable Rotational Viscometer |
| Viscosity Range | 1–6,000,000 cP (mPa·s) |
| Temperature Accuracy | ±1.0% of full-scale reading |
| Speed Control | 200 programmable RPM settings (0.1–200 rpm) |
| Display | 5-inch full-color touchscreen |
| Compliance | ASTM D2196, ISO 2555, USP <911>, GLP/GMP-ready data logging |
| Interface | USB PC connectivity with optional PG Flash and Rheocalc T software support |
| Standard Spindles | LV (4), RV/HA/HB (6) depending on configuration |
| Operating Environment | Ambient temperature |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DV2T |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 1 to 320 × 10⁶ mPa·s (cP) |
| Speed Control | 0.01–200 rpm (200 programmable increments) |
| Accuracy | ±1.0% of full-scale reading |
| Repeatability | ±0.2% |
| Temperature Measurement | Integrated RTD probe (±0.1 °C typical) |
| Display | 5-inch full-color touchscreen |
| Compliance | FDA 21 CFR Part 11 (electronic signatures, user access levels, audit trail) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DV2T Gel Time Tester |
| Type | Rotational Viscometer with Gel Time Measurement Capability |
| Compliance | ASTM D2471, ISO 3219, USP <911> (Gelation Time) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 1–320 mPa·s (cP) |
| Display | 5-inch Full-Color TFT Touchscreen |
| Compliance | FDA 21 CFR Part 11 Ready |
| Accuracy | ±1.0% of full-scale reading |
| Repeatability | ±0.2% |
| Temperature Probe | Integrated RTD sensor (±0.1 °C) |
| Data Interface | USB-B to PC |
| Standard Accessories | LV-1 spindle, leveling bubble vial, PG Flash software |
| Optional Software | RheoCalcT (included with DV2T EXTRA configuration) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DV2TLV |
| Viscosity Range | 1–200 mPa·s |
| Instrument Type | Benchtop (Not Online) |
| Operating Environment | Ambient Temperature |
| Software | RheoCalc T v3.x |
| Compliance | FDA 21 CFR Part 11 (Electronic Signatures, User Access Control, Audit Trail) |
| Data Storage | Password-Protected Local Database |
| Test Modes | Single-Point, Ramp, Hold, Cycle |
| Mathematical Models | Bingham, Casson, Power Law, Herschel-Bulkley |
| Multi-Sample Comparison | Up to 5 Data Sets |
| Temperature Control | Not Integrated (Requires External Bath or Peltier Accessory) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DV3T |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 1–1.6 × 10⁶ mPa·s (cP) |
| Display | 7-inch full-color touchscreen (multi-language support) |
| Temperature Probe | Built-in RTD sensor |
| Accuracy | ±1.0% of reading |
| Repeatability | ±0.2% |
| Connectivity | USB PC interface (included), optional PC control & automated data acquisition via PG Flash software |
| Compliance | Supports GLP/GMP documentation workflows, audit trail-ready for FDA 21 CFR Part 11–aligned environments (when used with validated software configuration) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DVNext |
| Instrument Type | Rotational Rheometer |
| Sample State | Liquid |
| Bearing Type | Mechanical Bearing |
| Minimum Speed | 0.01 rpm |
| Maximum Speed | 250 rpm |
| Sample Volume | 0.5–2.0 mL |
| Shear Rate Range | Up to 1875 s⁻¹ (with CP-52Z) |
| Torque Accuracy | ±1.0% of Full Scale |
| Repeatability | ±0.2% |
| Temperature Range | 0–100 °C |
| Geometry | Cone-and-plate |
| Control Interface | Integrated Touchscreen Display |
| Auto-Zero Function | Yes |
| Auto-Range Torque Measurement | Yes |
| Wetted Materials | 316 Stainless Steel |
| Optional Accessories | Luer fittings, embedded Pt100 temperature probe, cleaning adapters |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | DVNext |
| Instrument Type | Rotational Viscometer/Rheometer |
| Viscosity Range | 1–320M mPa·s |
| Display | 7-inch Full-Color Touchscreen |
| Compliance | 21 CFR Part 11, GAMP 5 |
| Temperature Accuracy | ±1% of full scale (with PT-100 probe) |
| Internal Storage | 150 MB |
| Connectivity | USB, LIMS-ready, optional Ethernet/Wi-Fi |
| Control Mode | Standalone or PC-controlled (RheocalcT software) |
| Spindle Coupling | Magnetic coupling system |
| Leveling | Digital auto-leveling |
| Test Modes | Single-step & multi-step programmable protocols |
| Yield Stress & Flow Curve Analysis | Built-in Casson, Bingham, Power Law, Thix Index models |
| Temperature Integration | Compatible with AP/SD series circulators and high-temperature systems |
| Accessories Support | Cone/plate geometry, UL adapter, small-volume adapter, gel time coupler, DIN/ISO adapters, spiral, T-bar, paddle rotors, roller bearing spindles (HA/HB), RV/HA/HB-1 spindles |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DVNext |
| Instrument Type | Rotational Viscometer/Rheometer |
| Mounting | Benchtop (Fixed) |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 1–320 million cP (mPa·s) |
| Temperature Control | External (via AP/SD Series Circulators or High-Temp Systems) |
| Temperature Accuracy | ±1 °C |
| Temperature Resolution | 1 °C |
| Speed Range | 0.01–250 RPM (2,600 programmable increments) |
| Compliance | FDA 21 CFR Part 11 (Regulatory-Ready Firmware & Audit Trail) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DVNext |
| Viscosity Range (LV) | 0.01–250 cP (mPa·s) |
| Viscosity Range (RV/HA/HB with Optional Spindles) | up to 320M cP |
| Speed Control | 2600 programmable RPM increments (0.01–250 RPM) |
| Display | 7-inch full-color touchscreen |
| Temperature Accuracy | ±1% of full scale (with PT-100 probe) |
| Data Storage | 150 MB internal |
| Compliance | 21 CFR Part 11, GAMP 5 |
| Connectivity | USB, optional LIMS integration |
| Accessories Supported | UL Adapter (1 cP min), Cone & Plate systems, AP/SD temperature baths, RheocalcT software, barcode scanner, gel timer module, DIN adapters, T-spindles, spiral adaptors, small sample adapters |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DVNext |
| Viscosity Range | 0.01–250 mPa·s |
| Instrument Type | Benchtop (with portable operational flexibility) |
| Compliance | Fully compliant with FDA 21 CFR Part 11 in standalone mode |
| Connectivity | Ethernet and LIMS integration supported |
| Rotor Mounting | One-hand quick-coupling mechanism |
| Leveling | Integrated electronic auto-leveling system |
| Operating Environment | Ambient temperature (15–30 °C) |
| Application Class | General-purpose rotational viscometry for QC, R&D, and production environments |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | DVNext CP |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 0.1 – 7.8 M mPa·s |
| Display | 7-inch Full-Color Touchscreen |
| Compliance | FDA 21 CFR Part 11 & GAMP 5 (Regulatory Edition Only) |
| Onboard Storage | 150 MB with Timestamped Data Files |
| Temperature Control | Integrated Peltier-Based System with Embedded Sample Probe |
| Software | RheocalcT™ (PC-based), Optional LIMS/Barcode Integration |